Home
Energy Sistem D850
Contents
1. VAC Frequency 50 Hz 60 Hz Voltage Range 162 290 VAC OUTPUT Voltage 230V AC Frequency 50 Hz 1 Transfer Time Typical 2 6 ms Output waveform Modified sinusoidal BATTERY Type Sealed acid battery 12 V 9 AH x 1 Charging Time 8 hours to recover 90 of the capacity PHYSICAL Dimensions 287 x 100 x 142 mm Weight 4 9 Kg with battery ENVIRONMENTAL CONDITONS Temperature 0 40 C Humidity 0 90 SOFTWARE Compatibility Windows 98 SE ME NT 2000 2003 XP 2008 Vista Energy Sistem Soyntec S A warrants its products to be free from defects in materials and workmanship at the time of purchase The warranty period is 36 months from the date of purchase for UPS with the exception of the batteries which have a 24 months warranty Visit the Support section at http support soyntec com and select your product to view the FAQ Frequently Asked Questions The solution to your problem is very likely to have been already published there You will also be able to download user manuals user guides drivers and updates If you cannot find an appropriate solution in the Support section you may send us your enquiry or warranty service request by email support soyntec com Alternatively you may prefer to contact the distributor from which you purchased the product presenting the purchase receipt or invoice Specifications are subject to change without notice O 2009 by Energy Sistem Soyntec S A Q All rights re
2. on the back panel of the UPS Connect from OUT port to the computer with another phone line cable Turn On Off Turn on the UPS unit by pressing the power switch Turn off the UPS unit by pressing again the power button Cold Start Function The cold start function allows to power up your devices during blackouts To use the cold start function just switch on the UPS turn on you computer and peripherals as usual The battery should have enough charge in order to perform the start up of your connected devices 17 4 IMPORTANT SAFETY INSTRUCTIONS IRTAN f JRIANI OAT gt Risk of Electric Shock Do not open the UPS except for battery replacement following the safety norms Risk of Electric Shock This unit receives power from more than one source Disconnection of AC sources and the DC source is required to deenergize this unit before servicing gt Risk of Electric Shock Hazardous live parts inside this unit are energized from the battery supply even when the input AC power is disconnected gt To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing he unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or urnaces gt To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area ree of conductive contaminants gt Do not attach non computer related items such as medical e
3. SOYNTEC SH SEKURY D850 SAI UPS User manual SEKURY D850 KEEP THESE INSTRUCTIONS Please read the following information carefully and save this manual for further reference Disregard of these safety notes may endanger life or health as well as the function of the equipment and the safety of your data The UPS Sekury D850 provides full protection to your computer and peripherals such as TFT screens modems routers and etc Moreover prevents data loss generated by blackouts surge and other electrical disturbances In these cases the UPS will quickly provide enough power to allow you adequate time to save your files close your applications and turn off the computer avoiding damage to your data and devices MAIN FEATURES S m N N Power protection against surge overvoltage overload short circuit and spikes Line interactive technology with microprocessor control AVR Automatic Voltage Regulation Telephone fax ADSL protection USB connection for computer monitoring PC monitoring software Cold start function power up your devices during blackouts gt Off mode battery charging PACKAGE CONTENTS UPS Sekury D850 User manual USB cable CD ROM with monitoring software 15 16 2 PRODUCT OVERVIEW FRONT VIEW Power Switch UPS status LED Normal mode AC green LED on Battery Mode green LED flashing pem LM Protected Sc
4. huko outlets USB port AC input 6 RJ11 connectors for telephone fax ADSL protection Rearm fuse 3 INSTALLATION AND INITIAL SETUP Before installation please inspect the unit Make sure that the UPS it s in perfect conditions and free of any kind of external damages Placement amp Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits A Connection to mains and charging Plug in the AC input cord to the wall outlet This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected Devices connection Plug in the devices to the outlets on the UPS rear panel Simply switch on the UPS unit and the devices connected to the UPS will be protected CAUTION NEVER connect a laser printer or scanner ag s to the UPS unit This may cause unit damage amp RJ 11 connection for Modem Phone ADSL surge protection Connect a single modem phone line into surge protected IN outlet
5. in the system tray The UPS monitoring software installation guide and user manual can be found in the CD ROM UPS Computer connection through the USB port Once software setup process it s finished please connect the USB cable to the computer s free USB port The USB connection will allow you to monitor and manage the UPS through the PC with the software provided Problem Possible Cause Solutions No LED display on the front panel Low battery Charge the UPS at least 6 hours Battery fault Replace the battery with the same type of battery The UPS it s not turned on Press the power switch again to turn on the UPS Alarm continuously Remove some devices first Before reconnecting equipment please verify that the When power fails back up time is short pounds Wien tie Pomel load matches the UPS capability specified in mains is normal he specs UPS overload Remove some critical load Battery voltage is too low Charge the UPS at least 6 hours Battery defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery The mains is normal but LED is flashing Power cord is loose Reconnect the power cord properly 19 20 Model Sekury D850 CAPACITY 850 VA 480 W INPUT Voltage 220 230 240
6. quipment life support equipment microwave ovens or vacuum cleaners to UPS gt Do not plug the UPS input into its own output gt Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit n the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS gt Do not connect the UPS into a non earthed outlet or with distinct plug formats apart from type C F When replacing the batteries use the same number and type of batteries gt Do not dispose of batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes Unplug the UPS prior to cleaning and do not use liquid or spray detergent A battery can present a risk of electric shock and high short circuit current The following precaution should be observed before replacing batteries Remove watches rings or other metal objects e Use tools with insulated handles Wear rubber gloves and boots 18 Please do not connect the UPS to the computer USB port until the software setup process it s finished a Install the monitoring software included in the CD ROM b Follow the on screen instructions to install the software c When your computer restarts the monitoring software will appear as an orange plug icon located
7. served TRADEMARKS All company brand and product names are trademarks or registered trademarks of their respective companies DECLARATION OF CONFORMITY Manufacturer Name Energy Sistem Soyntec S A Address Pol Ind Finestrat C Calpe esq C Alicante S N 03509 Finestrat Alicante Spain Tel 902 388 388 Fax 902 119 034 NIF A53107488 We declare under our own exclusive responsibility that the product Soyntec UPS Sekury D850 Manufacturing country China Is in compliance with the following essential directives norms and standards of the European Union 2006 95 EC 2004 108 EC 93 68 EEC 21
Download Pdf Manuals
Related Search
Related Contents
EMiT: A process mining tool User Manual - batjak.com Coming Soon! Downloaded from www.vandenborre.be EUROLITE LED Lichtketten m/o Controller User Manual Tecnostyl AT3/6 DFG/TFG 16 - 50 A/B/C-S &「セミナー紙上編(16 )」 Copyright © All rights reserved.
Failed to retrieve file