Home
Rosewill RPLC-500KIT
Contents
1. 18 CHAPTER FORMING A POWERLINE HOMEPLUG AV NETWORK 18 3 1 USING THE SECURITY PUSHBUTTON 19 3 2 USING THE UTILITY cu ieee ete 19 CHAPTER 4 JOINING A 21 4 1 USING THE SECURITY PUSHBUTTON ccccececcesececsccncececeneecscecesescenessenenenseas 21 42 Us THE UTI T Geer ee a 22 APPENDIX A IMPROVING THE TRANSMISSION QUALITY 23 APPENDIX B SPECIFICATIONS 23 APPENDIX C ACRONYMS AND ABBREVIATIONS 25 APPENDIX D RPLC 500 QOS 25 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Package Contents The following items should be found in your package gt 2x Rosewill RPLC 500 500Mbps Powerline Gigabit Ethernet Adapter gt 2x RJ45 Ethernet Cable gt 1 Quick Installation Guide gt 1 Resource CD for RPLC 500 including Rosewill Powerline Utility e Quick Installation Guide e User Guide Note Make sure that the package contains the above items If any of the listed items are da
2. HPLC 500 supports connection for a total of 8 nodes B Plug and play to your routers computers and other network devices e Power up your Network with Ultra fast speed B Physical data rate is up to 500Mbps B Ethernet Speed is up to 1000Mbps e Enjoy Stable HD Videos and Gaming 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual B With a pair of plug and play RPLC 500 installed you can easily extend your home network through any electrical outlet for Internet access by HDTVs Blu ray players DVRs PCs and game consoles e QoS Management Enhances Streaming Quality B RPLC 500 supports 4 level type QoS and 8 level VLAN priority fields which automatically improves the streaming quality Green Feature for Power saving mode RPLC 500 will detect signals when there is no signal transmit it will automatically enters Power Saving mode which saves near 80 of the energy consumption 1 3 Application High Definition HD and Standard Definition SD video distribution e e Higher data rate broadband sharing for Powerline LAN e Shared broadband internet access e TV over IP IPTV and Voice over Internet Protocol VoIP Notebook 7 Lea TY Modem Router 7 500 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual 1 4 System Requirement f need to use Powerline Utility Operating system Windows 98SE 2000
3. Welcome to the Power Packet Utility Setup Wizard The installer wall quide through the steps required to install Power Packet Utility on your Computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil ar criminal penalties and will be prosecuted to the masimum extent possible under the law Cancel 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual O 3 Select Agree and then Next to continue ie Power Packet Utility License Agreement Please take a moment to read the license agreement now IF you accept the terms below click 1 Agree then Othenvise click Cancel Qualcomm Atheros Inc License Agreement PLEASE READ THIS SOFTWARE LICENSE LICENSE CAREFULLY BEFORE THE QCA SOFTWARE BY USING THE OCA SUFTVWAEKE ARE AGEEEING TO BE BOUND BY THE TERMS OF THIS LICEHSE IF YOU NOT AGREE TO THE TERMS OF THIS LICENSE DO HOT USE THE SOPTVVARE IF YOU DO NOT AGREE TO THE TERMIS OF THE LICENSE YOU RETUEN THE OCA SOFTWARE TO THE PLACE WHERE YOU P TUE TrM TA LI TmT TmT TUER T PAT TTI sd STITT SS TTT M LI md T md mM 1 Do Mat Agree C3 I Agree 4 You can choose your own destination folder to install or click Browse to select the i
4. XP 32 64 bit and Vista 32 64bit otherwise no OS require CPU Intel Pentium 11 or better clock rate faster than 2 0GHz recommended RAM At least 128MB Screen resolution Any resolution Free disk space At least 20MB Network interface At least one Fast Ethernet 100 Mbps network card and a Ethernet Cord 1 5 Hardware Diagram of RPLC 500 eae to Power Data Reset Ethernet Security RJ45 Port Power Ethernet Port Plug 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual 1 5 1 LED System runs normally Green Blink e System is resetting e System is in the process of password synchronization e System is in Power Saving mode L Green Ethernet No Ethernet connection Green Orange Red On The PLC adapter has connected to the powerline network The Data LED color may vary according to the Data Transmit Quality Green Data Transmit Quality Excellent Orange Data Transmit Quality Average Red Data Transmit Quality Poor Off The PLC adapter does not connect to the powerline network 1 5 2 Powerline Adapter s Button and Connector Reset Pressing and holding the Button for between 10 seconds and 15 seconds makes the adapter restore the factory default settings Security Pressing and holding the button for less than 3 seconds makes the adapter a member of the existing Powerline Network Ethernet Port RJ45 Port The Ethernet port connects to an Ethernet
5. access values are connected to the same powerline Users want to use them to form a logical network Forming a HomePlug AV logical network Please follow below steps to form a logical network using the Security button 1 Press the Security button on Device A for less than 3 seconds 2 Press the Security button on Device B for less than 3 seconds The button on B must be pressed within 2 minutes 3 Wait for connection to complete The Power indicator on both devices will flash evenly at 1 second interval until the operation succeeds or fails The Power indicator will illuminate steadily on successful completion If an error occurs the Power indicator both devices will flash unevenly for 2 minutes 3 2 Using the Utility Scenario Devices A and B are located in different networks Users want to use them to form a logical network In this case using the Security pushbutton cannot pair Devices A and B Users can only use the Utility to form a logical network 9 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Please follow below form logical network using the Utility 1 Connect Device A to the network card of a PC 2 Open the Utility The Main tab page displays information about Device A after connection succeeds Power Packet Utility Main Privacy Diagnostics About Local D eviee s your computer Device Type MAD Address Connected to Hom
6. if the user wants to delete a device whose password has been entered 2 2 4 About Tab The About screen shows the software version and provides a html link to a website such as http www qua qualcomm com Clicking web address you can visit the web site Power Packet Utility Main Privacy Diagnostics About Power Packet Utility Version 6 0 0002 Released April 12 2010 Copyright 72005 2012 Qualcomm Atheros All Rights Reserved qualcamm com License Copyrights Copyright c 1999 2005 NetGroup Politecnico di Torro Italy Copyright c 2005 2009 Technologies Davis California All nights reserved Redistribution and use in source and binary Forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Preferences Chapter 3 Forming a Powerline HomePlug AV Network This chapter describes how to form a HomePlug AV logical network AVLN using the Security pushbutton and using the Utility Operation progress and outcome can be monitored by observing the behavior of the power LED 18 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual 3 1 Using the Security Pushbutton Scenario Devices A and B with different NMK Network Membership Key used to authenticate
7. 4 02 nat entered Unknown Mar 05 04 50PM pom 10 80 52 00 00 55 nnt entered Unknown 05 04 50PM Device 44 90 00 02 nnt entered Unknown 05 04 50PM Device 8 00 07 26 91 2C 44 nat entered HomePlug Mar 13 06 43PM Device 10 DOE OC OA BLUE UC UB nnt entered Unknown Mar 24 02 10PM gt Delete Save Print Report The Lower panel displays the history of all remote devices appeared on the computer over a certain period of time All the devices and the parameters of the devices on the powerline network are listed Devices that are active on the current logical network show a transfer rate in the rate column Devices on other networks or devices that no longer exist are shown with a in the rate column The following remote device information is available from the diagnostics screen Device alias name MAC address Password Device last known rate Device last known network name HomePlug chipset manufacturer name Date device last seen on the network MAC firmware version The diagnostics information displayed can be saved to a text file for later use or be printed for reference for a technical support call Click Delete to delete the devices which are no longer part of the network A dialog window pops up with a 17 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual TE confirmation message
8. C the joiner that is not located in any networks attempts to join Network N Any devices on Network N can become the adder Joiner Joining a network Please follow below to add Device C to Network N using the Security button 1 Press the Security button on Device A or Device B for less than 3 seconds making it the adder 2 Within 2 minutes press the Security button Device C the joiner for less than 3 seconds 3 Wait for connection to complete The Power indicator on Device A or Device B and Device C will flash at 1 second intervals until the process succeeds or fails It will illuminate steadily on success If an error occurs the Power indicator on Device A or Device B 2 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual and Device C will flash unevenly for 2 minutes 4 2 Using the Utility Scenario Devices A and B are located in Network N Device C the joiner that is located in another network attempts to join Network N See Do as follows to add Device C to Network N using the Utility 1 2 T Connect Device C to the network card of a PC Open the Utility The Main tab page displays information about Device C after connection succeeds Click the Privacy tab page Enter a name in the Private Network Name field Click Set Local Device Only When the page shown as below displayed the setting success Now Device C
9. N Virtual Local Area Network Appendix D RPLC 500 QoS Support RPLC 500 allows for 4 levels of Channel Access Priority CAP 0 3 The 8 levels of VLAN Ethernet tags must be mapped to the 4 levels of CAP priority where CAP 3 is the highest priority and CAP 0 is the lowest CAP 3 priority might be used for voice and network management frames and CAP 2 is used for 25 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual streaming video and music while 1 and CAP are used for data Default CAP The Default CAP group allows for default priority mapping of packets that do not have a VLAN TAG The settings are available for Unicast directed to a host Unicast default CAP 1 sets the default channel access priority for unicast frames not matching any other classification or mapping e IGMP managed Multicast Stream Fixed to CAP 2 sets the default channel access priority for stream data belonging to a snooped IGMP multicast group e IGMP default CAP 3 sets the channel access priority for IGMP frames these are the group management frames not the stream data e Multicast Broadcast sets the default CAP for multicast frames not in a snooped group and for broadcast frames The following are the factory default settings for VLAN Tags and TOS Bits VLAN Tag User Default CAP TOS Bit User Default CAP Priority Priority Priority Priority CAP1 CAP1 O
10. d to change it The steps for setting the password of the device required when creating a private network are as follows e Click the device name to select the device in the lower panel Click Enter Password A dialog box appears showing the device name and password Set Device Password Device Device 14 OD A BB ODEULE 22 Password The Password typically appears as a number and letter cade in groups of four separated by dashes KB Y GH2b BRHTK Lz254 It is found on the device or packaging Lancel e Click OK to verify the password The password field accepts the device 313 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Ck 4 password in any case formats with or without dash A confirmation box appears if the password is entered correctly If a device is not found a message appears providing suggestions to solve the common problems This process might take a few seconds to get completed Add This button is used to add a remote device to the existing network by entering the device password of the device A dialog box will appears You can enter a device name and the password Also refers as DEK on the back Label this DEK is generates via MAC address If the device is found and the password is entered correctly a confirmation box appears If a device is not found a message appears providing suggestions to solve the common problems Add Dev
11. e Uny OR ALL devices whose Password has been entered They communicate together but are isolated from devices with Set All Devices a different network name All HomePlugAV devices are loaded using a default logical network network name which is normally HomePlugAV In the Privacy screen you can modify a private network by changing the network names and the passwords of the devices You can always reset to the HomePlugAV network Public by entering HomePlugAV as the network name or by clicking on the Use Default button fc Note If the network name changes to anything other than HomePlugAV the network type in the main screen is displayed as Private Set Local Device Only 15 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual This button is used to change the network name and password of the local device If a new network password is entered all the devices appeared in the main panel prior to this are no longer present in the new network effectively making the local devices not to communicate to the devices which are in the old logical network Click Set Local Device Only the devices previously set up with the same logical network same network name appears in the device list Set All Devices This button is used to change the logical network of all devices that appear in the main panel If these devices whose passwords have been entered for the same log
12. ePlug Aw 7420 Device Connect 2 HomePlug 7420 0 00 00 00 00 00 11 Upgrade Firmware Search for Local device on your computer 3 Click the Privacy tab page Enter a name in the Private Network Name field Power Packet Utility Main Privacy Diagnostics About Use this screen to create a Private Network that provides you with extra security Private Network Mame iz3456789 DR Use Default Public Network nat share the network name with others you do not want to be part of this network Setting the network name for your PLC 4 Click Set Local Device Only When the following page is displayed the setting succeeds Now Device A has been removed from its logical network Information Network name setting success 5 Repeat the procedures above to configure Device B Configure Device 20 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual 55 with the same Private Network Name as Device A After the operation success Devices A and B form a new logical network Chapter 4 Joining a Network This chapter describes how to add a device to an existing HomePlug AV logical network AVLN using the Security Reset pushbutton and using the Utility Operation progress and outcome can be monitored by observing the behavior of the power LED 4 1 Using the Security Pushbutton Scenario Devices A and B are located in network N Device
13. evices connected to it If no local HomePlugAV device is discovered the status bar displays NO HOMEPLUG ADAPTERS DETECTED Power Packet Utility Main Privacy Diagnostics About Local Device s your computer Device Type Address Connected ta HomePlug 420 Device HomePlug AV 7420 D 00 00 00 00 00 11 Upgrade Firmware 1 Powerline Device detected Network Type Private Autascan On Fate Mbps MAC Address El Device 14 EEG 24 00 DC AA BB UO UC 22 Rename Enter Password Add The lower panel displays all the HomePlugAV remote devices which are 12 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual SEE AB385 SS EB i _ discovered in the current logical network The total number of remote devices connected in the same network is displayed above the remote device panel Network type Public or Private depends on the network status of the local device Autoscan shows whether the autoscan function is on The following information is displayed for all the devices that appear in the lower panel Device Name This column shows the default device name which may be modified To change the name click Rename or click the name and edit it in the list MAC Address This column shows the MAC addresses of the remote devices Password By default this column is blank You can click Enter Passwor
14. has been removed from its logical network Information Press the pushbutton on Device A or B for less than 3 seconds making it the adder Within 2 minutes press the pushbutton on Device C the joiner for less than 3 seconds Wait for connection to complete The Power indicator on Device A or Device B and Device C will flash at 1 second intervals until the process succeeds or fails It will illuminate steadily on success If an error occurs the Power indicator on Device A or Device B and Device C will flash unevenly for 2 minutes 22 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual T Appendix A Improving the Transmission Quality is important to use the PLC product complying with the following correct rules because it can significantly improve the transmission capacity of the network For the PLC device without female socket it is recommended to plug the device directly into a wall socket not to power stripe Chipset Atheros AR7400 Compliant with IEEE 1901 Standards Compatible with HomePlug AV standard IEEE802 3 IEEE802 3u IEEE802 3ab Encryption 128 bit AES Encryption 23 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Capable of extending up to total of 8 Powerline adapters in one environment Connection Type RJ45 Connection Speeds 10 100 1000M Kit Type Double Maximum PLC sup
15. ical network a dialog box appears indicating the success of this operation For the devices whose passwords are not entered this operation will fail and it will report a failure message 2 2 3 Diagnostics Tab The Diagnostics screen shows the system information and history of all remote devices appeared over a period of time The Upper panel shows technical data concerning software and hardware on the host computer that are used to communicate through HomePlug on the powerline network It includes the following Operating system platform version Host network name User name MAC address of all NICs Network interface card connected to the host Identify versions of all driver DLLs and libraries used NDIS and optionally HomePlug chipset manufacturer name Turbo Only devices MAC firmware version Turbo Only devices MAC addresses of all devices connected locally to the host Version of the configuration utility Vendor name 16 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Power Packet Utility Si Main Privacy Diagnostics About System Information On MIC 1 30 5 0 49 No HomePlug Device Connected On 2 MAC 34 08 04 31 07 BF HomePlug Device 1 MAC 00 44 68 00 00 00 Network password Unknown Metwarkname Vendor Qualcomm Atheros Remote Device History Log MAC Address Mbps Network Last Seen DOE BOE B2 DICE 4
16. ice to Network Device Hame EE Password PASS WORD GOES HERE The Password typically appears ag a number and letter cade in groups of four separated by dashes SKSY GHzb BH1E Lz5 It is Found the device or packaging Cancel Note The device must be in the powerline plugged in so that you can confirm the password and add the device to the network If the device is not located a warning message appears Scan This button is used to perform an immediate search for HomePlugAV 14 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual RRR devices connected to the powerline network By default the utility automatically scans every a few seconds and updates the displayed information 2 2 2 Privacy Tab In the Privacy screen you can maintain security for the logical network and select the device included in the network Power Packet Utility Main Privacy Diagnosties About Use this screen ta create a Private Network that provides you with extra security Private Network Name Unknown Networkname Use Default Public Network Do not share the network name with others you not want to be part of this network After setting the name above choose how it will be applied below Place This Network Only the device attached to this computer the Local Device Set Local Device Isolates this computer fram others el Local Devic
17. m o 3 OM _ Ow _ 5 _ _ Thank you for purchasing a quality Rosewill Product Please register your product at www rosewill com for complete warranty information and future support for your product Rosewill Customer Service Hotline 1 800 575 9885 Rosewill Customer Service Support techsupport rosewill com 26 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual COPYRIGHT amp TRADEMARKS Specifications are subject to change without notice is a registered trademark of Rosewill Inc Other brands and product names are trademarks or registered trademarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from Rosewill Inc Copyright 2010 Rosewill Inc All rights reserved http www rosewill com Safety Warning This device is intended for connection to the AC powerline For installation instructions please refer to the installation section of this guide The following precautions should be taken when using this product Read all instructions before installing and operating this product Follow all warnings and instructions marked on the product Unplug the device from the wall outlet before cleaning Use a damp cloth for cleaning Do not use liquid cleaners or aerosol cleane
18. maged or missing please contact with your distributor 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Chapter 1 Introduction to Hardware Thank you for purchasing Rosewill s RPLC 500 Homeplug AV compliant Powerline Adapter The RPLC 500 adapter can transmit data up to 500mbps via household s power outlet RPLC 500 can help you to establish a high speed network that supports video voice and data without wiring and drilling It is suitable for using in a wide range of both residential at home and commercial offices apartments hotels warehouses network applications 1 1 Expanding your Network with RPLC 500 The RPLC 500 plugs into an power outlet to extend cable or DSL modem connection or your current Ethernet Network to almost any power outlet in your home with any new cabling Devices can securely communicate with each other via the 128 bit Advanced Encryption Standard AES through RPLC 500 at a high speed transfer rate of 500Mbps and Gigabit LAN support c Note Powerline Technology has certain limitations 1 The best performance for Powerline Data transmission will be under one power circuit 2 Performance may be decreased under different circuits but within one Electricity Meter due to the drop off via hardware 1 2 Key Features e Plug and Play with Quick and Easy Installation B Installation requires no new wiring B Every power socket becomes a connection node in the household
19. network cable The other end of the cable connects to your computer or other Ethernet enabled network device Connecting to the router modem Insert One end of the RJ45 Cable Recommend using Cat 5E cable or above to this port and the other end to the router or modem Then plug into the electrical outlet E 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual LLLI ad Modem Router Connecting to PC Smart TV NB Blu ray Player Media Player IP Phone Insert One end of the RJ45 Cable Recommend using Cat 5E cable or above to this port and the other end to the other devices Then plug into the electrical outlet Chapter 2 Introduction to Utility Note Before installing the PLC utility software make sure that there is no any other powerline utility installed on your computer If there is another utility installed please uninstall it and restart your computer 2 1 Utility Installation Please follow the steps below to install the utility 1 Please insert the utility CD into the computer s CD ROM drive Select the Utility Installation from the Wizard Page 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Of osewill Smart wizard Powerline Adapter Powerline Adapter RPLC 500 Utility Installation Quick Installation Guide 2 he window for installing the utility software will display Click Next to continue im Power Packet Utility
20. nstallation folder and then click Next to continue 10 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual MEME im Power Packet Utility Select Installation Folder The installer will install Power Packet Utility to the following folder To install in this folder click Next To install to different folder enter it below or click Browse Folder CAProgram FilesiRosewillP ower Packet Utility Disk Cost Install Power Packet Utility for yourself for anyone who uses this computer Everyone Just me 5 You can choose your own destination folder to install or click Browse to select the installation folder and then click Next to continue ig Power Packet Utility Contirm Installation The installer is ready to install Power Packet Utility on your computer Click Mest to start the installation Is 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual O 2 2 Utility Introduction Click the desktop icon below to enter the configuration page Power Facket Utility 2 2 1 Main Tab The Main screen provides a list of all powerline devices logically connected to the computer when the utility is running The top panel shows the local HomePlugAV devices connected to the network interface card NIC of the computer Click Connect The utility automatically scans the powerline periodically for other HomePlugAV d
21. osewill 500Mbps Powerline Gigabit Ethernet Adapter RPLC 500 User Manual o D 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual O Contents PACKAGE CONTENTS ccccccccssssssssssssseseeeeeeccccccccccccccsssssssseseeseeecececcccccccccccsssssseesesseeeeeeees 3 CHAPTER 1 INTRODUCTION TO 4 1 1 EXPANDING YOUR NETWORK WITH 500 4 1 2 KEY FEATURES 4 1 3 5 1 4 SYSTEM REQUIREMENT e nennen nnn nena nena aa Rua 6 1 5 HARDWARE DIAGRAM OF 500 eere eren un 6 1 5 1 7 1 5 2 Powerline Adapter s Button and Connector 7 CHAPTER 2 INTRODUCTION TO UTILITY 8 2 1 UTILITY INSTALLATION d eco vxeoExgs eee Ewan uwE EE cuEs Eoo ruo EE ERES 8 2 2 UTILITY INTRODUCTION nn unen anna u nune a unus 12 2 2 1 Main 12 2 22 PVC 15 2 2 3 IDIAQHOSIICS TaD ccm 16 2 2 4 About
22. port lt 4 0W Operation Mode Power Consumption 2 8W Idle Mode Frequency Band 2 MHz 67 5 MHz 0 97W Standby Mode ToS Support up to 4 level type QoS Support up to 8 level VLAN priority field IGMP snooping for multicast to multiple unicast mapping QoS Support Deployment requirements Devices with 10 100 or 10 100 1000 Mbps Ethernet port System Requirement Operates system not require Utility software OS support Microsoft Windows 2000 XP Vista 7 3 54 x 2 17 x 1 41 in 90 x 55 x 36 mm 1 Powerline adapter Weight 0 24 lbs 108 g 1 Powerline adapter Temperature 0 C 40 C Humidity 10 90 Non condensing 24 500Mbps Powerline Gigabit Ethernet Adapter KIT RPLC 500KIT User s Manual Appendix C Acronyms and Abbreviations AVLN AV In home Logical Network the AVLAN is the set of STAs that possess the same network membership key Every AVLN is managed by a single CCo CCo Central Coordinator CSMA CA Carrier Sense Multiple Access Collision Avoidance DAK Device Access Key DM Device Manager IGMP Internet Group Management Protocol NEK Network Encryption Key NID Network ID Identification NMK Network Membership Key PLC Powerline Communication PIB Parameter Information Block STA station a STA in the network with a connection to the powerline and being able to source or sink traffic TDMA Time Division Multiple Access Terminal Equipment Identifier TOS Type Of Service VLA
23. rs Do not operate this product near water This product should never be placed near or over a radiator or heat register Do not use an extension cord between the device and the AC power source Only a qualified technician should service this product Opening or removing covers may result in exposure to dangerous voltage points or other risks Do not plug the device into a power strip or surge protector because these devices may consist of filter and impair signal Avoid plugging the device right next to noisy sources such as cell phone charger Halogen light noisy desktop computer vacuum cleaner etc These cases result in poor transmission speed Unplug the device from the wall outlet and refer the product to qualified service personnel for the following conditions e liquid has been spilled into the product e product has been exposed to rain or water e the product does not operate normally when the operating instructions are followed e product exhibits a distinct change in performance Your product is marked with this symbol which is known as the WEEE mark WEEE stands for Waste Electronics and Electrical Equipment It means that used electrical and electronic products should not be mixed with general waste Used electrical and electronic equipment should be treated separately 27