Home

Hunter 27209 remote control

image

Contents

1. and quickly release either light button or 9 once When the light is turned on again it will remember the brightness level it was at before it was turned off and resume at that level again Press both of the light buttons 6 amp F together to begin Safe Exit Mode The LED light on the transmitter will blink 4 times to let you know it s start ing to turn the light off The light will slowly dim down until its completely off Down Dimmer 44092 01 12 15 10 Hunter Fan Company 7 Troubleshooting Symptom Possible Causes Solution 1 No functions operate Main Power not restored Replace fuse Turn ON circuit breaker Turn ON wall switch Fan pull chain not set to High Set fan pull chain to High speed Light pull chain not set to ON Set light kit to ON Receiver wiring incorrect Verify wiring connections Transmitter not programmed to Re program the remote Refer to Programming the Remote Page 8 receiver in fan Battery too weak Replace with new 12 Volt alkaline battery Refer to Transmitter Installation Section 5 2 Fan clicks when remote buttons Fan pull chain not set to High Set fan pull chain to High speed pushed but blades do not move 3 Fan clicks when remote buttons Light pull chain not set to ON Pull light chain to turn ON pushed but light does not work 4 Operates only at close range Signal blocked from reaching Extend antenna into ceiling box or
2. A23 or equivalent inside the handheld transmitter 2 Mount the remote holder over the ceiling fan s wall switch using the existing wall plate screws Refer to Figure 8 3 The transmitter can be placed on the remote holder for convenience or safekeeping Figure 8 44092 01 12 15 10 Hunter Fan Company Figure 7 5 e Programming the Remote Programming the Remote Hold down fan speed The remote transmitter and remote receiver should already be programmed to work together buttons 1 amp 3 together for Fan Low ____ 5 seconds to program the e If you want the remote to control a second fan or you want to re progam remote remote control Turn the power to the second fan or the fan you want to re program OFF at the wall switch Then turn it back ON Within 30 seconds press the 1 Fan Low and 3 Fan High buttons on the transmitter together and hold them down for 5 seconds The LED light on the transmitter will blink 3 times to confirm The fan s light will turn OFF and the fan will turn ON at low speed to further confirm the programming has taken effect Repeat this process to correct interference with other devices or to program additional fans to this remote Fan e If there is any fan in your home you do NOT want programmed to this remote make sure the power to that fan is turned OFF at its wall switch while programming the remote Fan Operation For best fan operation Start the fan on Hi
3. EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY CONTROL IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us mishandling improper installation modifications or damage to the Control while in your possession or unreasonable use This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries To obtain a replacement return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy 400 Memphis Tennessee 38016 INNO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE If you need parts or service assistance please LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY on ae at our Web site at GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER ae Fan Company a RIGHTS WHICH VARY FROM STATE TO STATE 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 44092 01 12 15 10 Hunter Fan Company Printed in China
4. Univers sal Fan nandi Light Remote Control Hand Held Remote and Wall Cradle Owner s Guide and Installation Manual 4 SNI Form 44092 01 Sve 20101215 2010 Hunter Fan Co Read and Save these Instructions Caution Risk of Electrical Shock All wiring must be performed in accordance with national and local electrical codes If you are unfamiliar with the 2 Installation Preparation wiring codes you should use a qualified electrician Table of Contents 1 Welcome 3 e Receiver Installation To avoid overheating and possible damage to other equipment do not install to control a receptacle motor 4 e Transmitter Installation operated appliance or transformer supplied appliance Use only to control one ceiling fan with or without a light 5 e Programming the Remote fixture 6 Operation 7 Troubleshooting 8 e Warranty Ratings 120 VAC 60 Hz 1 0 Amp Fan Receiver Weight 6 oz 300 Watts incandescent light 2010 Hunter Fan Company 44092 01 12 15 10 Hunter Fan Company Notes 1 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rul
5. es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from the one the receiver is connected to e Consult the dealer or an experienced radio TV technician for help 3 For use only with electrically reversible ceiling fans rated at 1 0 amp or less 2 Installation Preparation and fan incandescent light kits rated at 300 watts or less 4 Not for use with shaded pole motors Hunter 42 Low Profile fans and Hunter Baseball fans Not recommended for use with the Hunter Original For Hunter Original series fans use Hunter control model numbers 27187 22691 or 27189 5 Medium and Low fan speeds are determined by the control and thus may vary from the factory settings due to
6. gh 3 and then select the desired speed e Press the High 3 Medium 2 or Low 1 speed buttons to turn the ceiling fan ON at the desired speed e Press the fan 0 key to turn the ceiling fan OFF Figure 9 44092 01 12 15 10 Hunter Fan Company Light Operation e Turn ON wall switch The light will turn ON at maximum brightness e Press and quickly release either light button on the hand held remote to turn the light OFF or ON e After a power outage the light will turn ON when power is restored Press and quickly release one of the light buttons once to turn the light back OFF after a power outage e Press and hold either light button for more than 1 second to activate the dimming cycle Press to turn the light ON at the maximum level and continue holding down to dim the light Press 9 to turn the light ON at a low level and continue holding down to brighten the light Continue to hold the light button to repeat the cycle Release the light button when the desired light level is reached To turn the light OFF Press both of the light buttons amp F together to begin Safe Exit Mode The LED light on the transmitter will blink 4 times to let you know it s starting to turn the light off The light will slowly dim down until it s completely off within 30 seconds This Safe Exit feature provides you with enough light to leave the room safely To turn the light off instantly press
7. installations will be one of these five types ti Profile If the fan is already installed turn the power OFF at the main electrical panel Reverse the installation procedure according efile to the fan instructions to the point of disconnecting the fan wiring Connect the receiver to the ceiling fan according to the mounting type as shown on Pages 4 5 IMPORTANT If your ceiling fan light kit is using incandescent bulbs then slide the CFL INC switch to the INC position Fig 2 If your ceiling fan light kit is using compact fluorescent light bulbs CFL then slide the CFL INC switch to the CFL position NOTE When the switch is in the CFL position the dimming feature is disabled and you will not be able to dim the light bulbs This feature is to protect both your bulbs and your receiver as CFL bulbs are not able to dim and will malfunction if dimming is attempted Low Profile Style I Figure 1 Secure receiver to the fan plate above the motor with UL listed cable ties not included Connect wiring as shown in Figure 6 Extend antenna through one of the ceiling plate Cable Tie Routing for Low Profile openings approximately 3 6 Fans Figs 1 amp 3 Insert cable tie through openings as shown DO NOT insert the cable tie through the inside of the receiver The cable tie can be placed across the length or idth of the receiver to best match your fan installation type 44092 01 12 15 10 Hunter Fan Company NOTE Some fans
8. may have considerable excess lead wire For easier canopy installation cut the excess wire leaving a minimum of 6 inches remaining Restrip the fan lead wires 1 2 inch Place remaining excess wire into the ceiling electrical box as needed Low Profile Style II Figure 3 Secure receiver to the ceiling mounting bracket with UL listed cable ties not included Connect wiring as shown in Figure 6 Extend antenna above the ceiling mounting bracket approximately 3 6 3 Receiver Installation Canopy Hanger Fig 4 Place receiver in canopy Connect wiring as shown in Figure 6 Extend antenna through one of the ceiling plate openings approximately 3 6 Hunter Hands Free Canopy Connect wiring as shown in Figure 6 Place receiver inside mounting bracket Extend antenna above the ceiling mounting bracket approximately 3 6 NOTE Some fans may have considerable excess lead wire For easier canopy installation cut the excess wire leaving a minimum of 6 inches remaining Restrip the fan lead wires 1 2 inch Place remaining excess wire into the ceiling electrical box as needed 44092 01 12 15 10 Hunter Fan Company Figure Bracket Hanger Starting with the antenna wire slide receiver inside mounting bracket If a ground wire mounting screw prevents the receiver from sliding into the bracket move ground wire and screw to an unused hole at the top of the bracket or secure with a canopy mounting screw The b
9. move it for better reception receiver Battery too weak Replace with new 12 Volt alkaline battery Refer to Transmitter Installation Section 5 Interference Re program the remote to a different frequency by pressing and holding fan speed buttons 1 amp 3 together for 5 seconds Light on transmitter will blink 3 times Light will come on and fan will turn on at low speed to confirm programming is complete 5 Inconsistent operation Signal partially blocked from Extend antenna into ceiling box or move it for better reception reaching receiver RF interference Turn OFF wall switch for 5 seconds then turn back ON Continuing RF interference Re program the remote Refer to Programming the Remote Page 8 44092 01 12 15 10 Hunter Fan Company 8 Warrant HUNTER FAN COMPANY CONTROL LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control Control Your Control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace it free of charge IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL THIS WARRANTY AND ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED THIS WARRANTY IS IN LIEU OF ALL OTHER
10. normal motor variations 6 For use with Hunter Hanging Systems excludes Hunter Original on flat ceilings or angled ceilings with a pitch up to 34 7 Not for use in applications where the fan does not have a wall switch Any changes or modifications to this equipment not expressly approved by Hunter Fan Company will void the user s authority to operate the equipment BEFORE YOU INSTALL THIS CONTROL USE THE PULL CHAIN SWITCH TO SET THE FAN SPEED TO THE HIGH POSITION BEFORE INSTALLATION DO NOT USE THE PULL CHAIN TO CHANGE THE FAN SPEED AFTER INSTALLATION AS DAMAGE TO YOUR FAN OR REMOTE MAY RESULT THE SPEED OF THE FAN SHOULD ONLY BE CHANGED BY THE HUNTER CONTROL 44092 01 12 15 10 Hunter Fan Company 3 Receiver Installation BEFORE INSTALLING THE CONTROL 1 USE THE PULL CHAIN SWITCH TO SET THE FAN SPEED TO THE HIGH POSITION BEFORE INSTALLATION DO NOT USE THE PULL CHAIN TO CHANGE THE FAN SPEED AFTER INSTALLATION AS DAMAGE TO YOUR CEILING FAN OR UNIVERSAL CONTROL MAY RESULT THE SPEED OF THE FAN SHOULD ONLY BE CHANGED BY THE HUNTER CONTROL 2 Set the ceiling fan light kit to the ON position before installation Installation Instructions 1 Install the ceiling fan according to its instructions up to the point of making the electrical connections Connect receiver to ceiling fan according to the mounting types shown on the next page Determine your ceiling fan mounting type from the L images on Pages 4 5 Most
11. racket must remain properly grounded Connect wiring as shown in Figure 6 Extend antenna above the receiver approximately 3 6 3 Receiver Installation 1 Use the 2 large orange wire connectors supplied to connect the receiver and Figure 6 house wiring then use the 3 small blue wire connectors supplied to connect the receiver and ceiling fan wiring Refer to the Wiring Diagram in Figure 6 If you are installing the remote with a Hunter Fan the wire colors in the fan will be as follows aia E Light Power Black with a White Stripe Black Hot marked LIVE Red Fan Power Black IN on red label LIGHT Common White y OUT These are only the Hunter fan wire colors Other White Neutral marked brands may use different colors NEUTRAL IN on red il label diik FAN OUT Antenna 2 Be sure the antenna is positioned securely so it does not interfere with the ceiling fan motor Do not modify or damage the antenna wire as control White marked performance may be reduced After securing the receiver antenna and ii ji wiring finish hanging the ceiling fan according to its instructions EA OUT on zs A Black White f Black amp White 3 Restore power at main electrical panel Wiring Diagram Hunter fan wire colors Other brands may use different colors 44092 01 12 15 10 Hunter Fan Company 4 Transmitter Installation 1 Install the included 12 Volt alkaline battery

Download Pdf Manuals

image

Related Search

Related Contents

フロントフェンダー 取扱説明書  Labview - Department of Materials Science and Metallurgy    Owner`s Manual / Manual del Propietario  Microsoft Applications for Windows Mobile 6 User Guide (P/N 72E  impostazione  Samsung BD-F6900 Korisničko uputstvo  Table of Contents  MANUAL DO UTILIZADOR  

Copyright © All rights reserved.
Failed to retrieve file