1. an EFA Overview The optional MVP WCS 52 Wall Charging Station FG5966 1X offers the same recharging and connection features for the MVP 5200i Touch Panel as the MVP TCS 52 Table Charging Station with the advantage of being placed within accessible locations where the table station is either inconvenient or impractical FIG 1 The MVP WCS 52 is available in white FG5966 13 or black FG5966 12 MVP WCS 52 MVP 5200i GB ecurity Release button FIG 1 MVP WCS 52 GB Wall Charging Station Front The features of the MVP WCS 52 include e Full charging of a docked MVP 5200i in approximately 4 5 hours e Touch panel password feature for security e Integrated docking alignment guides for easy docking Specifications MVP WCS 52 Specifications Dimensions HWD 8 88 x 6 38 x 2 19 22 54 cm x 16 19 cm x 5 56 cm Note Always use the cutout installation dimensions for the MVP WCS 52 when installing this unit into various surfaces This SP engineering drawing is available online at WwW amx com Power Requirements 1 7A 12 VDC Class II listed power supplemented Startup Power e Total 1 7A Requirements e Charging 1 1A e Ejection 0 6A Weight e Without back box 0 85 Ibs 0 39 kg e With back box 1 30 Ibs 0 59 kg Front Panel e Securing Magnets Secures MVP touch panel during Components ejection e Security Latch Adds the primary layer of security when mounting an MVP touch panel When the device
2. 23 41 MVP 5200i Gloss Black FG5966 01 MVP 5200i Gloss White FG5966 02 The MVP 5200i touch panel remains locked in the MVP WCS 52 until unlocked by the user This may be done by entering an appropriate password please refer to the MVP 5200i User Manual available from www amx com for more information or by pressing the Security Release button on the front of the device in emergencies The station ejects the MVP 5200i device top first FIG 2 The device uses two neodymium rare earth magnets to secure the MVP 5200i to the cradle when the touch panel is angled forward Other AMX Equipment d __ Wall Charging Station 2 lt MVP 5200i P o A s lt 4 Security Release button FIG 2 MVP WCS 52 GW Wall Charging Station Side View Unlocking the Touch Panel Once placed within the Wall Charging Station the MVP 5200i remains secured until the user unlocks it To release the touch panel from the Wall Charging Station 1 Press the Security Release button 2 A password keypad will pop up on the MVP 5200i screen Enter a password in the password keypad and press Enter 3 Wait for the Wall Charging Station to pivot the touch panel away from the wall 4 The device will remain in the ejected position until the MVP 5200i is removed Wait until the device s ejection door has completely withdrawn before re installing the MVP 5200i Recharging To recharge the MVP 5200i 1 Slide the de
3. Box 1 Cuta hole into the wall or surface intended to hold the back box The back box is sized 8 375 inches 21 27cm long and 5 75 inches 14 60cm high Use the included MVP WCS 52 Wall Charging Station Template 68 5966 01 as an aid for hole placement and measurement WARNING Make sure to measure the size of the intended hole before starting to cut it Cutting the hole slightly smaller than the dimensions to allow for adjustments is highly recommended 2 Select the knockout to be removed from the top of the back box The box has two knockouts at the top left and the top right Note To assist with wiring and to avoid mechanical stresses on the wire and the mechanism of the Wall Charging Station the top right knockout is preferred for use 3 Run the power cable through the knockout into the back box Pull out about six inches 15 25cm of cable into the back box to facilitate installation of the MVP WCS 52 4 Slide the plastic back box into the hole being careful not to twist or pinch the cable and set it flush with the wall Make sure that all of the lockdown wings are folded into their slots before attempting to insert the box For ease of installation the inside of the box has the direction UP labeled for reference 5 Extend the wings on the sides of the back box by tightening the screws inside the box taking care not to overtighten Not all of the wings must be extended to lock the back box in place but extending a m
4. In Box The optional Metal Rough In Box FG037 11 is 10 inches 25 40cm wide at its widest dimension wider than the bezel of the Wall Charging Station and is only intended for pre construction installations FIG 4 The Metal Rough In Box is used in conjunction with the Wall Charging Station s plastic back box The Metal Rough In Box must be located behind 3 8 0 95cm to 3 4 1 91cm of wall mounting surface material Install front surface of rough in box flush with surface of wall stud FIG 4 Typical Optional Metal Rough In Box Installation The Metal Rough In Box bears a wing on each corner which is intended to bridge gaps between studs and or spacers These wings may be bent carefully in order to fit a particular gap but may not be so bent as to allow the rough in box to hang in a vertical position Once placed in the desired position put at least one screw through each wing into the adjoining stud or spacer to secure it The interior of the rough in box contains a set of holes on either side as well as top and bottom for standard 1 4 inch screws Use these holes to anchor the rough in box to its adjoining studs or spacers WARNING Ensure that the metal rough in box is flush with the 2x4 studs Any overhang will affect the installation of the covering sheetrock as well as affect the placement of the plastic back box The rough in box has two sets of knockouts in the top and bottom one in the set for US wiring and one fo
5. e to the back box Note For ease of installation put each screw on a neodymium magnet in the device s interior compartment to keep them on hand until they are needed 11 Take a rubber foot and remove its adhesive backing Put the foot adhe sive side down in the slot surrounding the screw hole in the Wall Charg ing Station Press down firmly to remove any air bubbles from underneath the foot For full warranty information refer to the AMX Instruction Manual s associated with your Product s 3 11 2011 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com Tie Wrap Anchors Mini Captive Wire C PI i we T emai me ep a za y gt ih M LE 7 pi FIG 3 MVP WCS 52 Rear View Of Anchors And Connector Plug 12 Install an MVP 5200i device by placing it into the interior compartment bottom first Press the top of the touch panel until it is flush with the Wall Charging Station The neodymium magnets will hold it in place 13 To remove the MVP 5200i unlock the touch panel and wait for the touch panel to pull away from the Wall Charging Station Once it has been released grip it by the top of the device and pull it free from the Charging Station Installing the Optional Metal Rough
6. inimum of two wings on opposite sides of the box is highly recommended Apply enough pressure to the screw head to keep the box flush with the wall this ensures that the wing will tighten up against the inside of the wall WARNING Make absolutely certain that the back box is in its intended position Once the back box lockdown wings are extended removing the back box will be extremely difficult without damaging the wall in the process 6 Prepare the captive wires for the 2 pin 3 55 mm mini captive wire connector used for the MVP WCS 52 s power supply e Strip 0 25 inch 6 35 mm of wire insulation off all wires e Insert each wire into the appropriate opening on the connector e Turn the screws clockwise to secure the wires in the connector Do not over torque the screws doing so can bend the seating pins and damage the connector 7 Secure the power cable to the device using either of the two tie wrap anchors included in the Installation Kit at the top rear of the device FIG 3 Point the head of each tie wrap toward the center of the device 8 Firmly seat the mini captive wire connector to the power connector on the device 9 Firmly seat the device against the back box Make sure that the tab con nector at the top of the device is locked into the back box 10 Insert the two installation screws from the MVP WCS 52 Installation Kit into the screw holes in the interior compartment of the device and tighten them to anchor the devic
7. is inserted this latch grabs onto the rear of the touch panel and secures it to prevent it from inadvertently being removed e Interface Connector Pins A set of retractable pins male that connect to the underside MVP connector strip This connection provides both communication and power between the touch panel and the MVP WCS 52 e Support Cradle This retractable mechanism supports a resting MVP panel and allows a user to either insert or remove a connected MVP panel e Security Release pushbutton Located on the front of the unit this pushbutton toggles an on screen security keypad if security is enabled Entering the correct release code allows the MVP WCS 52 to release the touch panel from the security latch e Operating Temperature 0 C to 40 C 32 F to104 F e Operating Humidity 20 85 RH Storage Temperature 20 C to 60 C 4 F to140 F e Storage Humidity 5 85 RH Operating Storage Environments Installation Guide MVP WCS 52 wall Charging Station MVP WCS 52 Specifications Cont MVP WCS 52 Wall Charging Station Quick Start Guide 93 5966 12 Included Accessories Wallmount Plastic Back Box EMA5966 13 MVP WCS 52 Installation Kit Black KA5966 01bl MVP WCS 52 Installation Kit White KA 5966 01wh MVP WCS 52 Wall Charging Station Template 68 5966 01 MVP TCS 52 Table Charging Station FG5966 1 X Wallmount Metal Rough In Box 62 5966 12 PSN4 4 FG423 45 PSN6 5 FG4
8. r international wiring Note Make sure that the power cable has been pulled through the metal rough in box by the resident electrician before continuing the installation After completing the installation of the metal rough in box install sheet rock or other wall material over the box cut a hole matching the size of the inside diameter in the sheet rock and clean out all dust before proceeding with the installation of the Wall Charging Station Additional Information For additional installation information please refer to the MVP 5200i Modero ViewPoint Touch Panel User Manual available online at www amx com 93 5966 12 REV F NAO ATIR
9. vice into the Wall Charging Station cradle bottom first and make sure the device is fully seated in the Charging Station 2 Press the top of the MVP 5200i back until it clicks The touch panel is now locked into the Charging Station and the station will automatically charge the device s battery 3 To release the touch panel press the Security Release button enter the password if activated and wait for the Wall Charging Station to pivot the touch panel away from the wall Installing the MVP WCS 52 Since the Wall Charging Station is intended to be affixed to a wall or other permanent structure care must be taken to ensure its proper installation to prevent potential damage to the MVP 5200i placed within The device may be installed into existing walls but the optional metal rough in box must be installed before installation of drywall or other paneling Note Other than wall installation tools the only tool required for this installation is a 1 Phillips screwdriver Installing the Wall Charging Station and Plastic Back Box The Plastic Back Box has two knockouts at the top of the box and four 4 lockdown wings attached to the box with Phillips head screws For ease of installation the interior of the box contains an UP arrow pointing to the knockouts Note The optional Metal Rough In Box is not required for installation of the supplied Plastic Back Box but it offers an extra level of support To install the Plastic Back
Download Pdf Manuals
Related Search
Related Contents
Kit d`analyse de la concentration en dioxyde de chlore Noël ! - Epinay-sur Bedienungsanleitung 32”LED-Fernseher 有価証券報告書 Clarke CAV 16 Operator`s manual 取扱説明書 - Brinkmann Pumps English user manual i.fresh NCCO Air Sanitizing System Model: WS907 TDS 050 Benutzerhandbuch Copyright © All rights reserved.