Contents
1. 9 MECHANICAL REQUIREMENTS 9 1 Physical Dimension 150 mm W x 86 mm H x 140mm D M B 24PIN connector 3 3V_ 13 Orange 12VDC Black COM Black COM T 15 3 COM 17 5 COM Black COM 19 7 COM a d Red 5VDC 21 5Vsb Red 5VDC 22 10 12V Yellow 5vDC 23 11 12V Yellow EPS 12V 8PIN connector Signal Pin Pin Signal Yelow 1aV 6 Yeron av 8 4PIN peripheral connector HDD SATA connector Tiere Fin Red Signal Pin Pin 4PIN floppy connector FDD 12V 1 Yellow Yellow Yellow Warranty Information This product has a limited 3 year warranty in North America Europe and Australia For information on warranty periods in other regions please contact your reseller or SilverStone authorized distributor Warranty terms amp conditions 1 Product component defects or damages resulted from defective production is covered under warranty Defects or damages with the following conditions will be fixed or replaced under SilverStone Technology s jurisdiction a Usage in accordance with instructions provided in this manual with no misuse overuse or other inappropriate actions b Damage not caused by natural disaster thunder fire earthquake flood salt wind insect animals etc c Product is not disassembled modified or fixed Components not disassembled or replaced d Warranty mark stickers are not re
2. SilverStone Technology Co Ltd www silverstonetek com support silverstonetek com Issue date June 2012 NO G11216330 SILVER STONE Designing Inspiration STRIDER GOLD SERIES ST65F G ST55F G Compact design with a depth of 140mm for easy integration 80Plus Gold certification with higher efficiency 87 90 at 20 100 loading 100 modular cables 24 7 continuous power output with 40 C operating temperature Class leading single 12V rail Strict 3 voltage regulation and low ripple amp noise Silent running 120mm fan with 18dBA minimum ny STCSF G ST55 G A SPECIFICATION SilverStone Strider Gold ST65F G ST55F G ATX12V EPS 12V Switching Power Supply With Active PFC 80Plus Gold PS 2 This specification describes the requirements of 550W 650Watts switching power supply with an stretch ATX form factor and EPS 12V 5V standby voltage remote on off control full range line input capability and forced air cooling characteristics 1 AC INPUT 1 1 AC input requirements The input voltage current and frequency requirements for continuous operation are stated below Table 1 AC Input Line Requirements lin ST65F G Baa 4 Arms Power factor correction PF gt 0 90 at full load 1 2 Inrush current regulation The power supply must meet inrush requirements for any rated AC voltage during turn on at any phase of AC voltage during a single cycle AC dropout condition during repetitive
3. Table lf the current limits are exceeded the power supply shall shutdown and latch off ny STCSF G ST55 G A ST55F G Voltage Over Current Limit lout limit 50A minimum 65A maximum 25A minimum 40A maximum 27A minimum 45A maximum ST65F G Voltage Over Current Limit lout limit 58A minimum 70A maximum 5V 25A minimum 40A maximum 3 3V 27A minimum 45A maximum 3 2 Over Temperature Protection The power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature In an OTP condition the PSU will shutdown When the power supply temperature drops to within specifide limits the power supply shall restore power automatically The OTP circuit must have built in hysteresis such that the power supply will not oscillate on and off due to temperature recovering condition 3 3 Over power protection The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machine 3 4 Under voltage protection In an under voltage fault occurs the supply will latch all DC outputs into a shutdown state when 12V 5V amp 3 3V outputs under 85 of it s maximum value 3 5 Over voltage protection The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuity and reference No single point
4. at full load and over 100 240VAC input ny STCSF G ST55 G A 4 2 Hold up time When the power loss its input power it shall maintain 16ms in regulation limit at normal input voltage and 80 full load AC 115V 60Hz or 230V 50Hz 5 ENVIRONMENT 5 1 Operation 010 40 Relative Humidity 10 to 90 non condensing 5 2 Shipping and Storage Relative Humidity 5 to 95 non condensing 5 3 Altitude 6 SAFETY 6 1 Underwriters Laboratory UL recognition The power supply designed to meet UL 1950 6 2 The power supply must bear the German Bauart Mark from TUV 7 ELECTROMAGNETIC COMPATIBILITY EMC 7 1 IEC 61000 4 2 ESD LEVEL X20KV4 7 2 IEC 61000 4 3 radiated electrical field requirement 7 3 IEC 61000 4 4 BURST 7 4 IEC 61000 4 5 surge Voltages 7 5 EN61000 3 2 harmonic current emissions If applicable to sales in Japan or Europe the power supply shall meet the requirements of EN 61000 3 2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full rated power 7 6 EN55024 class B radio interference CISPR 22 7 7 FCC part 15 subpart J class B 115VAC operation 8 MTBF 8 1 MTBF mean time between failures calculation The demonstrated MTBF shall be 100 000 hours of continuous operation at 250C full load and nominal line The MTBF of the power supply be calculated in accordance with MIL HDBK 217F The DC FAN is not included
5. goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Please refer to above Warranty terms amp conditions for further warranty details SilverStone Technology Co Ltd 12F No 168 Jiankang Rd Zhonghe Dist New Taipei City 235 Taiwan R O C 886 2 8228 1238 standard international call charges apply For Europe support eu silverstonetek de For all other regions support silverstonetek com
6. ON OFF cycling of AC and over the specified temperature range Top The peak inrush current shall be less than the ratings of its critical components including input fuse bulk rectifiers and surge limiting device 2 DC OUTPUT 2 1 DC voltage regulation 3 3 12V 3 11 64 12 0 12 36 Volts 12V 10 10 8 12 0 13 2 Volts Note 1 Voltage tolerance is requied at main connector and S ATA connector if used 2 Output transient response tested DC voltage regulation range 5V 5 12V 5 3 3V 5 5Vsb 5 12V 10 2 2 Load ranges 2 2 1 ST55F G rev fo Gases 0 5 1 Maximum continuous total DC output power should not exceed 550W 2 Maximum continuous combined load on 3 3V and 5V outputs shall not exceed 140W 3 Maximum combined current for the 12V outputs shall be 45A 540W 4 Maximum peak total DC output power should not exceed 600W 5 Peak power and current loading shall be supported for a minimum of 12 second 6 When 12V is load to 25A 12V minimum load is 0 02A 3 2 2 2 ST65F G Parameter 3 3V l Ames 5V Amps Amps Amps Amps 1 Maximum continuous total DC output power should not exceed 650W 2 Maximum continuous combined load on 3 3V and 5V outputs shall not exceed 150W 3 Maximum combined current for the 12V outputs shall be 54A 648W 4 Maximum peak total DC output power should not exceed 700W 5 Peak power and current loading
7. fault shall be able to cause a sustained over voltage condition on any or all outputs The supply shall provide latch mode over voltage protection as defined in Table Gavo sso 7 00 vons Gssvoo s aso vons 3 6 Short circuit An output short circuit is defined as any output impedance of less than 0 1 ohms The power supply shall shut down and latch off for shorting the 3 3 VDC 5 VDC or 12 VDC rails to return or any other rail Shorts between main output rails and 5VSB shall not cause any damage to the power supply The power supply shall either shut down and latch off or fold back for shorting the negative rails 5VSB must be capable of being shorted indefinitely but when the short is removed the power supply shall recover automatically or by cycling PS_ON The power supply shall be capable of withstanding a continuous short circuit to the output without damage or overstress to the unit 3 7 No load operation No damage or hazardous condition should occur with all the DC output connectors disconnected from the load The power supply may latch into the shutdown state 4 TIMING 4 1 Signal timing drawing 12VA5V 3 3V 0 P PW OK PW OK Sense level 95 of nominal Figure 2 PS OK Timing Sequence 1 T3 Power good signal turn on delay time 100ms 500ms 2 T4 Power good signal turn off delay time 1ms min 3 T2 Rise time 0 1 20ms 4 T6 Hold up time 16ms min Tested
8. moved or broken Loss or damages resulted from conditions other than ones listed above are not covered under warranty 2 Under warranty SilverStone Technology s maximum liability is limited to the current market value for the product depreciated value excluding shipping handling and other fees SilverStone Technology is not responsible for other damages or loss associated with the use of product 3 Under warranty SilverStone Technology is obligated to repair or replace its defective products Under no circumstances will SilverStone Technology be liable for damages in connection with the sale purchase or use including but not limited to loss of data loss of business loss of profits loss of use of the product or incidental or consequential damage whether or not foreseeable and whether or not based on breach of warranty contract or negligence even if SilverStone Technology has been advised of the possibility of such damages 4 Warranty covers only the original purchaser through authorized SilverStone distributors and resellers and is not transferable to a second hand purchaser 6 If a problem develops during the warranty period please contact your retailer reseller SilverStone authorized distributors or SilverStone http www silverstonetek com Please note that i You must provide proof of original purchase of the product by a dated itemized receipt ii You shall bear the cost of shipping or otherwise transporting the product to Sil
9. shall be supported for a minimum of 12 second 6 When 12V is load to 25A 12V minimum load is 0 02A 2 3 Output Ripple 2 3 1 Ripple regulation 12V2 120 mVp p 12V 100 mVp p 5VSB 50 mVp p 2 3 2 Definition The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1 Ripple and noise are measured at the connectors with a 0 1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system loading Ripple shall be measured under any condition of line voltage output load line frequency operation temperature ST65F G ST55F G A 2 3 3 Ripple voltage test circuit Power Supply AC Hot AC Neutral Figure 1 Ripple voltage test circuit 2 4 Overshoot Any overshoot at turn on or turn off shall be less 10 of the norminal voltage value all outputs shall be within the regulation limit of section 2 0 before issuing the power good signal of section 5 0 2 5 Efficiency Power supply efficiency typical 87 for at normal voltage at full load on all outputs 2 6 Remote ON OFF control When the logic level PS ON is low the DC outputs are to be enabled When the logic level is high or open collector the DC outputs are to be disabled 3 0 PROTECTION 3 1 Over current protection The power supply shall have current limit to prevent the 3 3V 5V and 12V1 12V2 outputs from exceeding the values shown in the following
10. verStone authorized distributors SilverStone authorized distributors will bear the cost of shipping or otherwise transporting the product back to you after completing the warranty service iii Before you send the product you must be issued a Return Merchandise Authorization RMA number from SilverStone Updated warranty information will be posted on SilverStone s official website Please visit http www silverstonetek com for the latest updates Additional info amp contacts For North America usasupport silverstonetek com SilverStone Technology in North America may repair or replace defective product with refurbished product that is not new but has been functionally tested Replacement product will be warranted for remainder of the warranty period or thirty days whichever is longer All power supplies should be sent back to the place of purchase if it is within 30 days of purchase after 30 days customers need to initiate RMA procedure with SilverStone Technology in USA by first downloading the USA RMA form for end users form from the below link and follow its instructions http silverstonetek com contactus php For Australia only support silverstonetek com Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the