Home

Da-Lite Tensioned Contour Electrol 137"

image

Contents

1. Blue Common Power Input Brown Hot UP UPD GND 240VAC 50Hz Green 5V STOP Green Ground to Case 3 POSITION DOWN SWITCH RJ9 NOTE Ground Must be gt Connected to Building Ground 5238 E Splitter Front of Wall Back of Dry Contacts Switch Wall Switch 240V WIRING DIAGRAM WITH OPTIONAL BUILT IN VIDEO PROJECTOR INTERFACE A CAUTION THE PROJECTOR MUST BE TURNED OFF 2 Connect the wires from the VPI that are labeled Low BEFORE CONNECTING THE TRIGGER WIRES TO THE Voltage Connection to the end of the extended screen PROJECTOR FAILURE TO DO SO MAY DAMAGE THE trigger wires above CONTROLLER IMPORTANT NOTE The wall switch is REQUIRED to make 1 Use 2 conductor 20 24 gauge wire to extend the low voltage any limit switch adjustments EVEN if a third party control connection from the projector s 5 or 12 volt screen trigger system is used Therefore it is advised to wire the switch or output to the length required to reach the VPI When provide a 4 conductor connection that is accessible extending the low voltage connection from the projector s screen trigger output be sure to maintain the proper polarity The red wire from the VPI is the signal and the black wire from the VPI is the ground Brown Hot 240VAC 50Hz Power Source Green Yellow Ground Green Yellow Ground Brown Down Blue Common Black Up Blue Common
2. Instruction Book for TENSIONED COUNTOUR ELECTROL DALITE IMPORTANT SAFETY INSTRUCTIONS When using your video equipment basic safety precautions should always be followed including the following this appliance Contact an authorized service 2 Position the cord so that it will not be tripped over i i repair work is required Incorrect reassembly pulled or contact hot surfaces 3 If an extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat by the manufacturer may cause a risk of fire shock or injury to persons 1 Read and understand all instructions before using 4 To reduce the risk of electric shock do not disassemble electric shock when the appliance is used subsequently 5 The use of an accessory attachment not recommended dealer when can cause electric TOOLS REQUIRED FOR INSTALLATION 2 Phillips Screwdriver 1 8 Hex Key included PRE INSTALLATION 1 Carefully unpack screen and remove outer wrapping 2 Set aside the Installation Kit Items inside will be used during from case installation INSTALLATION NOTE Carefully unpack screen Use supplied 1 8 hex key and 2 phillips screwdriver to remove silver shipping brackets attached to slat and screen case 6 5 11 16 gt There are three ways to install the Te
3. Front of Wall Back of Switch Wall Switch 5 12 Volt Screen Trigger on Projector TROUBLESHOOTING Visit www da lite com products tutorials php to find installation and troubleshooting tutorials You will also find a link to Live Chat for interactive support Symptom You can contact us by email at info da lite com or by phone at 800 622 3737 or 574 267 8101 with any additional troubleshooting questions Cause Solution Screen will not operate and motor does not hum Incorrect line voltage Blown fuse Tripped circuit breaker No power to operating switch or junction Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line Replace fuse Reset circuit breaker Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white leads Screen will not operate and motor does not hum Power at junction box Thermal overload tripped Broken wire in the down or up position Defective motor limit switch or capacitor Capacitor burned out Let motor cool down for 15 minutes Try again Check for continuity Cut off old splice and reconnect Replace motor assembly NOTE Motor is a sealed assembly Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap r D
4. E WITH DA LITE S WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership J an A Milestone AV Technologies Brand 3100 North Detroit Street Post Office Box 137 Warsaw Indiana 46581 0137 P 574 2678101 or 800 622 3737 574 267 7804 or 877325 4832 E info da lite com www da lite com DL 0116 12 12 2012 Da Lite Screen Company LLC Printed in U S A 88820
5. NOTE Do not remove the wall mount bracket even if you are not using it for mounting This provides structural stability to the case Using a 2 Phillips screwdriver loosen the four 1 4 x 5 8 screws holding the ceiling flush mount brackets Figure 3 Slide the ceiling flush mount brackets so that the mounting holes extend beyond the ends of the case All four 1 4 5 8 screws must remain within the channels Tighten the four 1 4 x 5 8 screws holding the ceiling flush mount brackets Figure 3 Before mounting your Tensioned Contour Electrol be sure the ceiling has adequate reinforcement Hold the screen case up to the ceiling and mark the hole locations The brackets have a set of front holes and a set of rear holes Attach the Tensioned Contour Electrol using the appropriate hardware for your ceiling type It is best to use at least one hole in each set CEILING HOOK MOUNT 1 The ceiling hook mount brackets are tied together and attached to the ceiling flush mount bracket at one end of the case Remove the ceiling hook mount brackets Remove the ceiling flush mount brackets using a 2 Phillips screwdriver See Figure 3 Retain four 1 4 x 5 8 screws Note Do not remove the wall mount bracket even if you are not using it for mounting This provides structural stability to the case The top of the screen case has two channels with threaded nuts that slide the length of the case Attach the two cei
6. Tensioned Advantage Electrol was ordered as a complete unit the up and down limits were pre set by Da Lite If your screen and roller assembly was ordered separately from the case or if general adjustment is needed please follow the steps below and refer to the 120V Wiring Diagram 1 Locate the wall switch and remove the cover plate from the wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are black round buttons on silver plates See 120V Wiring Diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on the back of the switch turns solid red This will put the motor in limit set mode Turn the wall switch over and use the down button on the front of the switch Press and hold the down button until the desired down position is reached If you travel too far down press the up button to move the screen upward If you press let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch over press and hold the down tactile button until the LED on back of switch blinks red twice The down limit is now set CAUTION DO ADJUST FOR MORE DROP THAN WHAT WAS ORDERED AT LEAST 1 1 2 WRAPS OF FABRIC MUST REMAIN ON THE ROLLER THIS SCREEN COMES STANDARD WITH 12 BLACK AT THE TOP NOTE If the screen is in
7. ired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the five 5 year warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Sales Partners at PO Box 137 Warsaw 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANC
8. limit set mode and no buttons pushed for 20 seconds the LED on the back of the wall switch will turn off the motor will return to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the motor in limit set mode Turn the wall switch over and use the up button on the front of the switch Press and hold the up button until the desired up position is reached If you travel too far up press the down button to move the screen downward If you press and let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch over press and hold the up tactile button until the LED on back of switch blinks green twice The up limit is now set CAUTION ADJUSTING THE UP LIMIT SWITCH BY MORE THAN 6 CAN CAUSE THE SCREEN SURFACE TO LOSE PROPER TENSIONING 5 To test the limit switch settings press and release the up or down buttons on the switch to operate the screen 6 Replace the switch and cover plate on the wall IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments even if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conduc
9. ling hook mount brackets using the 1 4 x 5 8 screws and threaded nuts two per bracket The brackets can be attached anywhere within 12 of the ends of the case Figure 4 Before hanging your Tensioned Contour Electrol be sure the ceiling has adequate reinforcement Using the holes in the ceiling hook brackets hang the Tensioned Contour Electrol using the appropriate hardware and fasteners for your ceiling type A Wall gt Sl Wall Mount ji Bracket Figure 2 1 4 X 5 8 Flat Head Screw Figure 3 Ceiling Hook Bracket 1 4 X 5 8 Flat Head Screw Figure 4 ELECTRICAL INSTALLATION 1 Open the junction box on the left end of the case using a 2 Phillips screwdriver Install electrical connections that apply to your unit Make sure to review the wiring diagram for proper hook up Replace the junction box cover NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C22 1 and the National Electric Code NEC NFPA 70 2 Test installation by running screen up and down a few times Be prepared to stop screen should any objects obstruct the movement of the screen To prevent damage to the motor the standard duty cycle is 1 minute on and 3 minutes off Junction Box Cover Figure 5 SCREEN ADJUSTMENT FOR 120V SCREENS If your
10. nsioned Contour Electrol Wall Mount Ceiling Mount or Ceiling Hook Procedures for each a method are as follows 2516 29116 WALL MOUNT 1 Using a 2 Phillips screwdriver loosen the two stop screws remove the wall mount bracket from the back side of the case Figure 1 6 3 8 Case Hook NOTE The ceiling flush mount and ceiling hook mount brackets are attached to the top side of the case These brackets are not necessary for wall mounting and can be removed at this time as 2 Secure the wall mount bracket to the wall at the desired height loo Bracket The wall mount bracket should be fastened to the wall studs or some reinforcement within the wall Concrete or brick walls Stop Screws require special fasteners and anchors Allow at least 2 3 8 Y above the wall mount bracket to be able to position the case on Slat Bar the bracket Figure 2 Figure 1 INSTALLATION continued 3 4 5 Make sure the bracket is level Hang the screen case on the wall mount bracket as shown in Figure 2 Be sure the case is fully seated on the bracket Tighten the two stop screws against the wall mount bracket using a 2 Phillips screwdriver Figure 1 CEILING FLUSH MOUNT The ceiling hook brackets are attached to the top side of the housing They must be removed prior to ceiling flush mount
11. own limit switch out of adjustment See instructions below See installation instructions Incorrect stopping position in upward direction Lost roller wrap Up limit switch out of adjustment See instructions below Adjust up limit switch Call for information Noise NOTE Screen will operate with a low pitched hum Squeaking rubber end plug rubbing on motor Grinding Foreign object in screen rubbing on roller or fabric Gear noise Center roller in case Remove Replace motor assembly Coasting Defective brake Replace motor assembly RESTORING LOST ROLLER WRAP 1 2 3 4 Remove tape strap Tape a strap to the bottom of the screen surface Push strap over back of roller Feed fabric as you pull strap to draw fabric over top of roller 10 1 LIMITED FIVE YEAR WARRANTY ON DA LITE TENSIONED CONTOUR ELECTROL PRODUCTS ONLY Da Lite Screen Company LLC warrants these products to the original purchaser only to be free from defects in materials and workmanship for a period of five 5 years from the date of purchase by the original purchaser provided they are properly operated according to Da Lite s instructions and are not damaged due to improper handling or treatment after shipment from the factory This warranty does not apply to equipment showing evidence of misuse abuse or accidental damage or which has been tampered with or repa
12. rol system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible LED RJ 22 Output RJ 45 Jack Wire White Common Black Power Input 120VAC 60Hz RJ 22 Pin Outs Tab Is Facing Up 12V Blue Bus RP Data Yellow RO Data Green 5V Red o Ground Black Clock White Standard RJ 22 can be used in place of RJ 14 cable Data R Cable Green Ground Ground Must be Connected to Hot Building Ground Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Receptacle RJ 45 Pin Outs Tab Is Facing Up Manual 2 Brown 12V Blue Bus RP Data Yellow a RO Data Green 5V Red Ground Black Clock Orange Manual 1 Purple TENSIONED CONTOUR ELECTROL INSTALLATION FOR 120V SCREENS 120V WIRING DIAGRAM WITH OPTIONAL BUILT IN VIDEO PROJECTOR INTERFACE CAUTION The projector must be turned off before connecting IMPORTANT NOTE The wall switch is REQUIRED to make the trigger wires to the projector Failure to do so may damage any limit switch adjustments EVEN if a third party control the controller system is used Therefore it is advised to wire the switch or rovide 3 conductor connection that 15 accessible Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projec
13. switch is in the off center position Press and release the up or down button on the wall switch to operate the screen 8 Replace switch and cover plate on the wall NOTE If stop button is pressed the wall switch will reverse direction To correct this press the stop button again This will reset the switch You will have to re set both the up and the down limit settings IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible TENSIONED CONTOUR ELECTROL INSTALLATION FOR 120V SCREENS 120V WIRING DIAGRAM 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board Up Limit Tactile Button Down Limit Tactile Button Front of Back of Wall Switch Wall Switch RJ 22 Jack Connection to Wall Switch atio eo To view a video of this installation visit http youtu be t2Z09PVAhEg or use the OR code below g ORO RJ 14 Pin Outs Tab Is Facing Up Bus RP Data White RO Data Green 5V Red Ground Black Supplied RJ 14 cable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party cont
14. tor connection that is accessible SCREEN ADJUSTMENT FOR 220V 240V SCREENS 1 Remove the cover plate from the 3 button wall switch and remove the switch from the junction box 2 Locate small 3 position switch on back of wall switch See Figure 5 for 120V screens or Figure 8 for 220 240V screens 3 To adjust the down limit switch slide the 3 position switch to the down position Press and hold the down button to run the screen down to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON Ah CAUTION DO NOT ADJUST FOR MORE DROP THAN WHAT WAS ORDERED AT LEAST 1 1 2 WRAPS OF FABRIC MUST REMAIN ON THE ROLLER THIS SCREEN COMES STANDARD WITH 12 BLACK AT THE TOP SEE THE SPECIFICATION DATA SHEET FOR DETAILS 4 When the screen is in the desired down position slide the 3 position switch to the off center position The down limit switch is now set 5 To adjust the up limit switch slide the 3 position switch to the up position Press and hold the up button to run the screen up to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON CAUTION ADJUSTING THE UP LIMIT SWITCH BY MORE THAN 6 CAN CAUSE THE SCREEN SURFACE TO LOSE PROPER TENSIONING 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit switch is now set 7 test limit switch setting make sure the 3 position
15. tor s 5 or 12 volt screen trigger 3 conductor 20 24 gauge wire can be used in place of the output to the length required to reach the VPI When extending supplied RJ 14 cable to connect the wall switch Connect the the low voltage connection from the projector s screen trigger BUS terminals on the wall switch to the corresponding BUS output polarity does not matter The red and black wires from terminals on the splitter board the VPI are interchangeable Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus LED RJ 22 Output RJ 22 Inputs Front of Back of Wall Switch Wall Switch Receptacle RJ 22 Jack Connection to Wall Switch RJ 45 Jack Data Hoz Cable VPI Trigger Module White Green Ground Common Ground Must be Connected to Black Hot Building Ground Power Input 120VAC 60Hz 5 12 Volt Screen Trigger on Projector TENSIONED CONTOUR ELECTROL INSTALLATION FOR 240V SCREENS 240V WIRING DIAGRAM ILT RJ 9 Pin Outs Tab Is Facing Up IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control Black system is used Therefore it is advised to wire the switch or Ground Common Red provide a 4 conductor connection that is accessible 5V Green Data or Down White

Download Pdf Manuals

image

Related Search

Related Contents

MOXA AirWorks AWK-1100 User`s Manual  Beckett EPDM1015HD Installation Guide  Philips HP4930 Hairdryer  手すりの取り付け(手すりがある場合のみ) 取り付け完了後の  F P NL E  BSサーボモータ (PDF/1.5MB)    Été 2008 - "Vers l`aventure et au-delà"  

Copyright © All rights reserved.
Failed to retrieve file