Netis System ST-3115 network switch

image

Contents

1. PKUM00932 NETIS SYSTEMS CO LTD Http www netis systems com MADE IN CHINA netis NETIS 16 24 Port Desk top amp Rack mountable Fast Ethernet Switch User Manual 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual Certification FCC CE FCC Statement This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual Warning A shielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception it is essential that only the supplied power cord be used Use only shielded cables to connect I O devices to this equipment You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment
2. Rack Installation The Switch can be mounted in an standard 1U rack space To install attach the mounting brackets one on each side and secure them with the screws provided Then use the screws provided with the rack to mount the Switch in the rack 2 3 Connecting the 16 24 Port Desktop amp Rack Mountable Fast Ethernet Switch to Your Network Description Function Connect to power adapter provided with unit Don t use other power adapters as your switch could be damaged These ports support network speeds of 10Mbps or 100Mbps and can operate in half and full duplex transfer modes These ports also support automatic MDI MDIX detection which gives the Switch true plug and play capabilities Just connect any network cable from a device to the switch and the switch will automatically detect the settings of the device and adjust itself accordingly 1X 16X 24X 2 4 LED Indicators The LED Indicators will allow you to monitor diagnose and troubleshoot any potential problem with the switch connection or attached devices Function Power on swe o Off Power off On Corresponding port connection normal LINK ACT Flashing Corresponding port data transmitting Off Corresponding port connection abnormal not connected ON Corresponding port works at 100Mbps I Corresponding port works at 10Mbps 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual 3 Troubleshooting 1 The Po
3. ase T gt IEEE 802 3u 100Base TX gt IEEE 802 3x Flow Control gt IEEE 802 3az 1 4 Working Environment Temperature gt 0 to 40 C operating gt 40 to 70 C storage Humidity gt 10 to 90 non condensing operating gt 5 to 90 non condensing storage Power gt 100 240VAC 50 60Hz 2 Installation 2 1 Before Installation Take note of the following conditions before using your switch gt Install the 16 24 port desktop amp rack mountable fast Ethernet switch in a fairly cool and dry place See Working Environment for the acceptable operating temperature and 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual humidity ranges gt Install the switch in a site free from strong electromagnetic sources vibration dust and direct sunlight gt Leave at least 10cm of space to both the left and right of the switch for ventilation gt Visually inspect the AC power jack and make sure the power adapter cord is securely connected gt Do not place items on top of switch 2 2 Installation gt Desktop or Shelf Installation When installing the switch on a desk or shelf the rubber feet included with the device should first be attached Attach these cushioning feet on the bottom at each corner of the device Allow enough ventilation space between the device and the objects around it gt
4. depend on EUT condition This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Package Contents The following items should be found in your package gt 16 24 Port Desktop or Rack mountable Fast Ethernet Switch gt Power Adapter gt User Manual gt Rack Brackets gt Screws Make sure that the packets contains above items If any of the above items is missing or damaged please contact your distributor Content 1 INTRODUCTION 1 1 1 PRODUCT OVERVIEW ooccccoccncccncnnnccncnnncnnnnncon 1 1 2 MAIN FEATURES ooccoccccncnnncnnnncnnncnnnnonnnnnnnnnnns 1 1 3 STANDARDS nennen 2 1 4 WORKING ENVIRONMENT ccccceeeeeneeeeeeeeneees 2 2 HARDWARE INSTALLATION 2 2 1 BEFORE INSTALLATION ccccceeccceeeececeeeeeees 2 2 2 INSTALLATION aka ai ER ERA 3 2 3 CONNECTING THE 16 24 PORT DESKTOP amp RACK MOUNTABLE FAST ETHERNET SWITCH TO YOUR NETWORK 4 2 4 VED INDICATORS castas 4 3 TROUBLESHOOTING 5 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch User Manual 1 Introduction 1 1 Product Overview The 16 24 Port Desktop amp Rack mountable Fast E
5. thernet Switch is designed to allow simultaneous transmission of multiple packets via an internal high speed data channel This means that it can partition a network more efficiently than bridges or routers in most environments This 16 24 Port Desktop amp Rack mountable Fast Ethernet Switch is a highly reliable network switch and is the ideal device for bridging Ethernet to Fast Ethernet work groups or networks Simple and cost effective it supports IEEE802 3 10Base T Ethernet and IEEE802 3u 100Base TX Fast Ethernet Designed specifically for connecting work group devices and desktops companies no longer have to invest in expensive and inflexible switches engineered primarily for backbone implementations Companies can deploy this scalable affordable switch that increases the aggregate bandwidth of the network by boosting throughput to the work groups that need it most 1 2 Main Features gt Compliant with IEEE802 3 10Base T Ethernet IEEE802 3u 100Base TX gt 16 24 port 10 100Mbps TX Auto Negotiation Ethernet Switch gt 3 2 4 8Gbps switching fabric capacity gt Full Half Duplex capability on each TX port gt Supports TP interface Auto MDIX function for auto TX RX swap gt IEEE802 3x flow control for full duplex back pressure function for half duplex operation gt Supports up to 8K MAC addresses gt LED indicators for simple diagnostics gt Built in power supply gt Plug and Play 1 3 Standards gt IEEE 802 3 10B
6. wer LED is not lit gt Check if the AC power cord is well connected Try to unplug and plug back in the power cord to the switch or try another power outlet 2 The Link LED is not lit gt Make sure the network configuration of connecting device is correct and network card and drivers are installed correctly gt Check the cable connections gt Make sure the cable distance between the switch and other IEEE802 3 compatible network device does not exceed 100 meters 3 Performance is bad gt Check the status of Ethernet switching If Ethernet switching is set to full duplex on one device but a partner is set to half duplex then performance will be poor gt Make sure the cable between the switch and other IEEE802 3 compatible network device is Category 5 UTP or better 4 Some devices can t talk to other devices on the network gt Check status of the Link LEDs to make sure devices are linked gt Make sure that the devices network configurations are correct gt Reset the switch if needed USA Canada Technical Support Phone toll free in USA amp Canada 1 866 71 network or 1 866 716 3869 Email usa_support netis systems com for North America only

Download Pdf Manuals

image

Related Search

Related Contents

FL110 / Nr. 3115 WBH t o p l e v e l lI Flächenlaser  3月号    User's manual FLIR bXX series FLIR iXX series  Technical Manual Lawn Mower Robot Troubleshooting  Descargar - Oracle Documentation  Basic Operation Guide  取扱説明書 - ネットワークジャパン  Econoflo Syringe Pump User`s Manual  FOCUS Enhancements MANL-1161-04 User's Manual  