Home
CyberPower Smart App Online
Contents
1. CyberPower SMART APP SERIES OL1500RTXL2U v CyberPower For mission critical enterprise applications requiring maximum power protection KEY FEATURES e 1000VA 1350W e Double Conversion Topology e Selectable Output 100 110 115 120 125V 50 60 Hz e LCD Control Panel with Removable Display Option e GreenPower UPS ECO Mode e 2U Rack Tower Form Factor e Extended Battery Module Options with Fast Charge Technology e SNMP HTTP Remote Management e 8 Outlets USB Serial ERO and Dry Contact Ports e PowerPanel Business Edition Runtimes 3 Minutes at Full load 9 Minutes at Half load CyberPower s patented GreenPower UPS technology reduces UPS energy costs up to 75 Save money and help ENERGY SAVING ace TecHNoLosy reduce Carbon emissions CyberPower Systems Inc 4241 12th Ave E Suite 400 Shakopee MN 55379 Toll free 877 297 6937 CPSww com The CyberPower Smart App Online OL1500RTXL2U rack tower uninterruptible power supply UPS with LCD control panel and pure sine wave output safeguards mission critical servers data center and telecom equipment VoIP and internetworking hardware that require seamless power correction Its Double Conversion topology is generator compatible and delivers consistent and clean AC power with zero transfer time protecting connected equipment and preventing costly business interruptions Auto bypass insures connected equipment continues to operat
2. e seamlessly when an overload or internal fault is detected Configurable GreenPower UPS ECO Mode improves UPS efficiency to 93 and reduces electrical and cooling costs Smart Battery Management SBM uses a 3 cycle charging mode to improve battery life while reducing heat being generated A Three Year Warranty ensures that this UPS has passed our highest quality standards in design assembly material or workmanship and further protection is offered by a 400 000 Connected Equipment Guarantee FEATURES amp BENEFITS Double Conversion amp Pure Sine Wave Output The OL1500RTXL2U with Double Conversion topology provides continuous pure sine wave output with zero transfer time by converting utility AC power to DC power and inverting it back to pure sine wave AC output The output power is identical to or cleaner than the power from the utility company grid free of harmonic distortion and electrical noise resulting in optimal line clarity LCD Control Panel With 43 different settings the innovative LCD interface enables users to check UPS status manage setup amp control and run testing options Status and log menus provide UPS vitals including input amp output voltage levels battery information runtime estimates load information event and fault logging and other system information The Configuration menu offers IT managers the ability to customize their OL1500RTXL2U UPS to their specific parameters of operation includi
3. erence ensuring clean power for connected equipment Audible Alarms Distinctive tones identify when the unit is running on battery power if it is overloaded or when the battery is low Resettable Circuit Breakers Convenient unit reset switch in case of an overload 3 Year Warranty Stringent manufacturing processes and innovative product design enables CyberPower to offer one of the strongest warranties in our industry CyberPower will repair or replace damaged units within three 3 years of purchase date Technical Support CyberPower will assist customers with any product installation or warranty concerns ISO amp Safety Certifications All CyberPower manufacturing facilities are state of the art and ISO 9001 Quality Tested Our products are certified by the FCC cUL and UL CyberPower OL1500RTXL2U SPECIFICATIONS GENERAL Double Conversion Yes ECO Mode Efficiency gt 93 100Vac 125Vac 60Vac 69Vac for 0 60 Load 70Vac 79Vac for 0 70 Load 80Vac 89Vac for 0 80 Load 90Vac 95Vac for 0 90 Load 96Vac 150Vac for 0 100 Load 40Hz 70Hz auto sensing UPS Topology Energy Saving INPUT Voltage Input Voltage Range Input Frequency Range Input Power Factor o 1 500 1 350 100 110 115 120 125Vac Configurable 2 50 60Hz Auto Sensing or Configurable 0 25Hz Line Mode 105 125 Load for 1 min 126 150 Load for 10 sec Battery Mode 105 130 Load fo
4. l RMCARD302 LED Indicators SNMP HTTP Remote Monitoring PHYSICAL a w omer iw O ENVIRONMENTAL 32 F to 104 F 0 C to 40 C 0 90 non condensing 0 95 non condensing Audible noise at 1 5M from surface lt 50 dBA of unit CERTIFICATIONS UL1778 CSA C22 2 NO 107 3 05 FCC DOC Class A Certifications RoHS Compliant WARRANTY Product Warranty 3 Years Limited Connected Equipment Guarantee CEG Amount 400 000 CyberPower Systems Inc designs and manufactures state of the art power protection and distribution equipment for corporate business home government and educational markets CyberPower leads the industry by surpassing customer expectations in the development design construction durability and functionality of uninterruptible power supply UPS products for computers peripherals and connected devices CyberPower Systems operates in the Asian Pacific North American and European markets For additional information including sales office locations and authorized reseller partners visit coSww com 2012 CyberPower Systems USA Inc All rights reserved All other trademarks are the property of their respective owners CyberPower reserves the right to modify product information or specifications without previous notice The information presented is accurate at the time of publication 09 2012
5. ng output voltage sync frequency alarm settings and other parameters The Test menu enables self testing to insure your UPS is operating correctly Removable LCD Control Panel The LCD control panel on the OL1500RTXL2U can be removed and relocated for easy viewing by using a DB26 cable sold separately that can be attached to the front of the UPS This feature provides easy access to view up to 10 ft away status or change settings on the UPS when it s installed in a hard to reach area such as the bottom of a rack in a crowded IT closet or on the floor GreenPower UPS Eco Mode The OL1500RTXL2U can be placed into an ECO mode that places the UPS into a bypass state with a user selectable voltage range for switching back to traditional Double Conversion online mode This mode improves the UPS efficiency from 90 to 93 Cost savings are not only achieved by reducing energy consumption but also by lowering the heat generated by the UPS Extended Battery Module EBM The runtime of the OL1500RTXL2U can be extended by integrating additional EBM BP386V60ART2U The OL Series UPS can have up to ten modules added With the easy to use LCD control panel you can select the number of additional EBMs and it will provide the correct estimated run time for your configuration For requirements beyond 10 EMBs contact CyberPower Technical support for directions Fast Charge Technology Each UPS and EBM BP386V60ART2U has i
6. r 10 sec 131 150 Load for 2 sec NEMA 5 15R 8 Crest Factor 3 01 THD lt 3 at Linear Load THD lt 5 at Non linear Load 10 15 Configurable Internal Bypass Automatic and Manual Plug Type Cord Length OUTPUT On Battery Waveform On Battery Voltage On Battery Frequency Overload Protection Outlets Total Outlet Type Rated Power Factor Harmonic Distortion ECO Mode Voltage Regulation Bypass Transfer Time BATTERY Runtime at Half Load min 9 Extended Battery Module BP36V60ART2U a ee Yes Mode SURGE PROTECTION amp FILTERING Runtime at Full Load min Battery Type Battery Size User Replaceable Hot Swappable Typical Recharge Time Replacement Battery Surge Suppression Phone Ethernet RJ11 RJ45 EMI RFI Filtration SMART APP SERIES MANAGEMENT amp COMMUNICATIONS 43 different settings or status options via the UPS Status menu UPS Setup menu and run Testing menus Rotatable LCD Control Panel Option Yes LCD Control Panel Removable LCD Control Panel Option Yes Requires a separate DB26 Cable HID Compliant USB Port Yes Serial Port Yes EPO Port Yes S Management Cable USB Cable Serial Cable Phone line Power On Blue Line Mode Green Battery Mode Yellow Bypass Mode Yellow Fault Red Replace Battery Red Audible Alarms Battery Mode Battery Low Overload UPS Fault Replace Battery Software PowerPanel Business Edition Yes Optiona
7. ts own built in charger that enables the UPS to recover its charge rapidly when utility power is restored As a result your charging time remains the same whether you add one EBM or ten modules Smart Battery Management SBM SBM uses a 38 cycle charging mode that improves battery life and reduces heat generated The first mode charges the battery to full the second mode maintains the charge at max and the final mode turns the charger off and allows the battery to rest After a slight discharge the UPS will restart the cycle ensuring runtimes are maintained PowerPanel Business Edition UPS Management Software This software suite manages the power for all servers and computers supported by the UPS on a network Features include application OS shutdown event logging power surge and voltage variations hibernation mode internal reports and analysis as well as remote management capability for comprehensive power control Windows Compatibility Our PowerPanel power management software has been fully tested and is compatible with Windows 2000 2003 XP 32 64 Vista 32 64 7 and Server 2008 Linux amp Virtual Machine OS Compatibility PowerPanel power management software has been fully tested and is compatible with most mainstream brands of Linux and many of the popular versions of Virtual Machine Operating Systems such as VMware ESX ESXi and Citrix Critical amp Noncritical Loads The UPS has two banks of outle
8. ts that can be configured so that the noncritical loads shut off after a set time frame to provide additional runtime for the critical load outlet Users can prioritize their equipments runtimes to maximize the output of the UPS to meet their power requirements Emergency Power Off EPO The EPO port can be connected to a master power switch allowing the power to be cut to the UPS in the event of an emergency Generator Compatible When connected to a generator the UPS can have the generator mode enabled so the UPS continues to receive input power even when the generator output frequency is less than stable The UPS will take the unstable input power and distribute it to connected equipment in pure sine wave output that is free of harmonics and distortion ENERGY SAVING TECHNOLOGY SMART APP SERIES Converter Mode With OL1500RTXL2U IT managers have the flexibility to set the output frequency regardless of the input frequency to match their connected equipment by selecting a 50Hz or GOHz output on the LCD control panel Multiple Language Options The OL1500RTXL2U LCD control panel can be configured in English Spanish and French for ease of use USB amp Serial Connectivity HID compliant USB port and Serial port enables full integration with built in power management and auto shutdown features of Windows Linux and VMware EMI RFI Filters Filters against electromagnetic interference and radio frequency interf
Download Pdf Manuals
Related Search
Related Contents
Suma Rinse 2636/14 Compra Urgente de Equipo Wifi para Campus Virtual Le saviez-vous ? Transport A la Demande Samsung SGH-E360 Kasutusjuhend User Manuals - Fieldpiece Instruments BV NANO - Portões Rossi Rexel 10405BK Manuel d`installation Veneco Ventilation Systems Copyright © All rights reserved.
Failed to retrieve file