Home
Exposure 2010s2
Contents
1. Input Output e 3 coax inputs 32KHz to 192KHz 16 to 24 bits e 2 optical inputs 32KHz to 96KHz 16 to 24 bits e 1 coax output 32KHz to 192KHz 16 to 24 bits l selectable on off in menu e 1 USB input 96KHz 24 bits fixed e 1 optical output 32KHz to 96KHz 16 to 24 bits selectable on off in menu 00000 BNC 1 OPT 1 1 line output 2V RMS fixed or up to 4 5V RMS p gt 00000 with volume control 2 DVD Player Ensure your unit is switched off Set the volume control on your amplifier to minimum before connecting the DAC Analogue Output For connection to analogue input on amplifier the volume level is fixed BNC 1 OPT 4 Please note that your 2010S2 DAC may take up to ANALOGUE OO O O WY l Fi IE i 48 hours to run in before reaching its optimal performance Each subsequent run in will then 78 Hou take about 30 minutes Satellite Decoder 9 Q If you are using a power amplifier set the volume to the minimum level for example 22 in the a Ensure left and right channels are connected correctly menu of the DAC right channel is marked in red b Orto a power amplifier volume level needs to be set to variable on the DAC 130911 FA EX 2010S2 DAC convert indd 1 9 13 2011 12 42 55 PM 3 Operation lt lt MANUAL gt gt D 9 PREVIOUS G NEXT MENU DISPLAY 4 Remote 130911 FA EX 2010S2 DAC convert indd 2 a Press to
2. decrease or increase the volume no function when LINE output is fixed level b Selects the previous input or setting when in menu mode c Selects the next input or setting when in menu mode d Selects the menu mode OUTPUT selects HP or LINE output DIG OUT selects the digital output ON or OFF FILTER selects one of 5 digital fillters SAMPLE FREQ displays the received sample frequency SETVOL selects the volume setting for the LINE output MAX selects the fixed level of 2V RMS VERSION displays the software version of the 201082 DAC use the previous and next buttom to navigate through selections e Turn the display ON or OFF in menu mode press to select function Control Input select up down Display on off Volume up down Mute Other buttons can be used with Exposure CD Players or Amplifiers Technical Specifications Frequency Response 20Hz 20Khz 0 2dB Total Harmonic Distortion lt 0 005 at 2V RMS 1KHz output Signal to Noise Ratio gt 110dB ref 2V RMS output 1KHz Channel Separation 20Hz 20KHz gt 60dB Mains Supply 110 120V or 220 240V 50 60Hz factory set Power Consumption 20VA Dimensions H x W x D 90 mm x 440 mm x 310 mm Nett Weight Unpacked 5 kg Gross Weight Packed 7 kg DAC filter settings A Low sample rate 32 48KHz lle 5 Linear phase half band filter Minimum phase soft knee filter 2 Si 4 Minimum phase half band
3. place objects filled with water such as vases on the unit Do not operate the unit in a damp environment or allow liquids to enter the unit Do not attempt to bypass the mains fuse or replace the fuse with one of a different specification Do not use abrasive or solvent based cleaning fluids on the case Failure to observe these precautionary measures may void your warranty Exposure Warranty Policy 1 the first three 3 years from the date of purchase This warranty is valid only if the unit is purchased from an The Exposure warranty entitles you to FREE repair of this unit for authorised Exposure dealer registered with the authorised agent in your country of residence The agent accepts no responsibility for defects arising from accident misuse abuse wear and tear neglect or through unauthorised adjustment and or repair or replacement of any components nor will they accept responsibility for damage or loss occurring during transit to or from the person making a claim under warranty The Exposure warranty covers Parts and labour costs for three 3 years from the date of purchase Please retain your original receipt as proof of purchase and purchase date The guarantee is extended only to the original purchaser and is not transferable When making claims under this warranty 1 The equipment should be suitably packed and returned to the dealer from whom it was purchased or directly to
4. the local distributor together with proof of purchase or a copy of the dated sales receipt If necessary the unit should be sent carriage pre paid by a reputable carrier NOT by post No responsibility is accepted for the unit whilst in transit to the dealer or agent and customers are advised to insure the unit against loss or damage whilst in transit serial number on the equipment will invalidate the warranty Any tampering or alteration made to the warranty card or to the The dealer or the agent shall notify the customer when the repairs have been completed The customer must claim the goods within fourteen days from the date of notice failing which the Company reserves the right to impose storage charges The Company reserves the right to dispose of the equipment after 90 days from the date of notice in a manner that it sees fit without compensation to the customer 9 13 2011 12 42 58 PM
5. filter Linear phase apodising filter Minimum phase apodising filter B Medium and high sample rate 88K2 192KHz 1 2 3 4 5 Linear phase soft knee filter Minimum phase soft knee filter Linear phase brickwall filter Minimum phase apodising filter Linear phase apodising filter Safety Incorrect installation or inappropriate use of the Exposure 2010S2 DAC may result in injury due to electric shock Ensure that the voltage rating on the rear panel of this unit matches that of your local mains supply Ensure that the mains cable and plug supplied with this unit is also correct Contact your dealer immediately if this is not the case This unit is protected by a mains fuse which is accessible as part of the IEC socket on the rear panel Fuse replacement specifications 220 240V units T630mA fuse 110 120V units T1 25A fuse Protect this unit against all forms of liquid Never expose unit to dripping or splashing or place objects filled with water such as vases on the unit Unplug unit from mains when not in use for prolonged periods Do not open this unit there are NO user serviceable parts inside Contact Exposure Electronics for advice on moving your equipment to another country or territory Caution For along and trouble free life of your 2010S2 DAC please ensure the following Protect unit against all forms of liquid Never expose unit to dripping or splashing or
6. j high fidelity engineering since 1974 Installation Exposure 2010S2 DAC Front View Exposure EE TER Yd lt lt MANUAL gt gt PREVIOUS NEXT MENU DISPLAY b Connect the DAC mains cable to the IEC mains input socket A c Connect to the mains S outlet on the wall DO NOT switch on 9 until all input and output connections are made a Turn volume control on your amplifier to minimum before connecting or disconnecting any n cables VOLUME E P K DONOTREMOVE SAT PARTS INSIDE 2 CD Player DVD AV Processor etc Connections The Exposure 2010S2 DAC is fitted with 6 digital inputs suitable for connection of CD players AV Processors PCs Qu ick Sta rt Man ual DVD players and other source components Thank you for purchasing the Exposure 2010S2 DAC Exposure 2010S2 DAC Rear View EXPOSURE ELECTRONICS LTD 50 60Hz Kus CHARTWELL ROAD lt ANALOGUE LANCING SUSSEX BN15 8TU UK POWER CONSU2 TION 20VA OUTPUT MADE IN ENGLAND 9 LEFT SP DIF OUTPUT BNC1 OPT1 BNC2 OPT2 BNC3 USBIN 2010S2 DAC HEADPHONE a RIGHT WJ as a Befo re you start i WARNING RISK OF ELECTRIC SHOCK DO NOT REMOVE a THE COVER NO USER SERVICEABLE PARTS INSIDE MUSAU REE Contents 200 240V T630mA exposure EC O 0000o mi NI EE Exposure 2010S2 DAC Mains cable HS 102 Exposure System remote control e 1 headphone output up to 4 5V RMS with volume control CD Player batteries not included
Download Pdf Manuals
Related Search
Related Contents
第5回 定時株主総会招集のご通知 Operating instructions G-BH1, G-BH9 2BH1 1 manual de usuario y técnico proyecto insoladora NAVIGON 72 Easy Programmable DC Power Supply User's Manual User's manual (short) - Astal Security Technologies Gemini XPM-3000 Stereo Amplifier User Manual Installation Manual & User's Guide TLP182 - Toshiba Copyright © All rights reserved.
Failed to retrieve file