EnGenius ECB350 WLAN access point
Contents
1. 83 9 9 LED Control This page allows you to control LED for Power LAN interface and WLAN interface of the ECB350 LED Control Home Reset LED Control Power LED e ON OFF LAN LED 9 ON OFF WLAN LED ON OFF Save Apply Cancel 84 9 10 Logout Click Logout in the Management menu to logout of the ECB350 interface 85 9 11 Reset In some circumstances it may be required to force the device to reboot Click on Reboot the Device to reboot the ECB350 Reset Home Reset The System Settings section allows you to reboot the device or restore the device to the factory default settings he unit to the factory default settings will erase all settings including any rules you have created Reboot the Device Restore to Factory Defaults 86 Appendix A FCC Interference Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ha
2. 7 Router This section is only applicable for AP Router Mode or Client Router Mode 7 1 WAN Settings There are four types of WAN connections Static IP DHCP PPPoE and PPTP Please contact your ISP to find out which settings you should choose 7 1 1 Static IP If your ISP Provider has assigned you a fixed IP address enter the assigned IP Address Subnet mask Default Gateway IP Address and Primary DNS and Secondary DNS if available of your ISP provider 37 WAN Settings Internet Connection Type Options Account Name if required Domain Name if required MTU Internet IP Address IP Address IP Subnet Mask Gateway IP Address Domain Name Server DH S Address Primary DNS Secondary ONS WAN Ping Discard Ping on WAN Accept Cancel Static IP Auto 192 158 255 BH 755 0 0 0 0 0 0 El B10 N55 576 1500 Home Reset 38 Internet Connection Type Select Static IP to begin configuration of the Static IP connection Account Name Enter the account name provided by your ISP Domain Name Enter the domain name provided by your ISP MTU Specify the Maximum Transmit Unit MTU size It is recommended that you accept the default setting of Auto Otherwise packets will be fragmented downstream if the MTU is set too high or too low which impacts network performance In extreme cases an MTU setting that is too low can prevent the ECB350 from establishing some connections
3. ECB350 11N Long Range Multi Function Gigabit CB AP V1 0 Table of Contents C Cg d U1 d RR RTT 5 1 1 Features and Benefits seseneeeseseseessesersesesesessesesossesesesorersesosenstststsobsts istos tses ot bs tseno sobs ts tseo ests oso S SESS ESOS SESEO SSES ESSES Seseo seses e eos es esee e sesen ens 5 EZ Package COMEN Sa E UU T P O 6 LS cl UNI SE WS ts dene de ibas ee le ite le d 7 L4 API AUO tenet steer ee enone MU XU MM MM ME E 7 2 Before you Begin C M 9 2 1 Considerations TOF Wireless Instala a ati 9 2 2 Computer settings WWINGOWS AP WINAOWS Tus ile 10 23 OA A O IA II AA 13 2 4 Pe CIV INS AI II A A DEUM M NE 14 3 Configuring Your Client Bridge ecco ie ec 1322558506515 EAE a 9961651202200 CAI 0002001207 005092 290150 60208 ADA TURAS AA 20d casi 16 SH MEE Ao A A N 16 CN D CO QE ATOS PR ee en 17 4 Buudind a Wireless NetWork ee 19 dL OS Tee 0 6 ee eee eee 19 A 18152018 TENO ad A M N oe uel o uS oa trol GADIS let EEN E UE ULM LOL Leia 20 e lee MORE Re re Taree T T H 21 44 ACCESS PONE e E E Te GE ER 45 WDS AP WDS Station Mode 23 AO IP AGO ee APA UP no E Mem 24 e ARDENNE NOUE AA S S ooo oom 25 AID E PH M HP H 26 5 1 SAVE REO Eee ene cL Mu DM MAE LM M DEUM M MA EUER ME DONI ADDE AMI A D A DUE E er 26 iZ RE O A eae 27 2 9 Id eee 29 54 e Ee idu escalada a ond ee nner Rey RE Ed 30 SE OS TA AA TA ias 31 O
4. Manually Set Date and Time Manually specify the date and time Automatically Get Date and Select a time zone from the drop down list and check whether you want to Time enter the IP address of an NTP server or use the default NTP server to get have the internal clock set automatically 9 7 Log This page allows you to setup Syslog and local log functions of the ECB350 Log Hom e Reset Syslog Syslog Disable Log Server IP Address Local log Local Log Enable Save Apply Cancel L og Enable or disable the syslog function Enter the IP address of the log server Enable or disable the local log service Click Save Apply to apply the changes or Cancel to return previous settings 82 9 8 Diagnostics This page allows you to analyze the connection quality of the ECB350 and trace the routing table to a target in the network Diagnostics Home Reset Ping Test Parameters Target IP Ping Packet Size 54 Bytes Number of Pings 4 StartPing Traceroute Test Parameters Traceroute target Start Traceroute Diagnosis Target IP Enter the IP address you would like to search Ping Packet Size Enter the packet size of each ping Number of Pings Enter the number of times you want to ping Start Ping Click Start Ping to begin pinging target device via IP Traceroute Target Enter an IP address or domain name you want to trace Start Traceroute Click Start Traceroute to begin the trace route operation
5. Note Profile Settings is only applicable in Access Point WDS AP or Router mode Current Wireless Settings Operation Mode Access Point Wireless Mode IEEE 802 11b g n Mixed Channel Bandwidth 20 40 MHz Frequency Channel 2 437 GHz Channel 6 Profile Isolation No 1 EnGeniusBEF 05 Hone 1 Profile Settings 2 N A SSID Security VID 5 NA 4 N A Spanning Tree Protocol Disabled Distance 1 Km 29 5 3 Connection Status Click on the Connection Status link under the Status menu This page displays the current status of the Network including Network Type SSID BSSID Connection Status Wireless Mode Current Channel Security Data Rate Noise Level and Signal Strength Note Only applicable in Client Bridge Client Router WDS Station and Repeater mode Connection Status RSS Hetwork Type Client Bridge SSID EnGenius BSSID 00 02 6F 10 10 14 Connection Status Associated Wireless Mode IEEE 802 11b g n Mixed Current Channel 2 427 GHz Channel 4 Security WPA2 PSK AES Tx Data Rates Mbps 52 Mbps Current noise level 95 dBm Signal strength 41 dBm Refresh 30 5 4 Wireless Client List Clicking the Wireless Client List link under the Status menu displays the list of clients associated to the ECB350 along with the MAC addresses and signal strength for each client Clicking Refresh updates the client list Note Only applicable in Access Point WDS AP Repeater and Router mode Client List Home Reset SSID MAC
6. lectriquea l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que lapuissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire al tablissement d une communication satisfaisante Le pr sent metteur radio IC 10103A ECB350 Mod le ECB350 a t approuv par Industrie Canada pour fonctionner avec les types d antenne num r s ci dessous et ayant un gain admissible maximal et l imp dance requise pour chaque type d antenne Les types d antenne non inclus dans cette liste ou dont le gain est sup rieur au gain maximal indiqu sont strictement interdits pour l exploitation de l metteur 89 Appendix C CE Interference Statement Europe EU Declaration of Conformity This device complies with the essential requirements of the R amp TTE Directive 1999 5 EC The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R amp TTE Directive 1999 5 EC EN60950 1 2006 A11 2009 A1 2010 Safety of Information Technology Equipment EN50385 2002 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields 0 Hz 300 GHz EN 300 328 V1 7 1 2006 10 Electromagnetic compatibility and Radio spectrum Matters ERM Wideband Transmission systems Data transmission equipment operating
7. ze tento typ zarizeni je ve shod se z kladn mi pozadavky a dalsimi prislusnymi ustanovenimi smernice 1999 5 ES dal Dansk Danish Undertegnede fabrikantens navn erkl rer herved at f lgende udstyr udstyrets typebetegnelse overholder de v sentlige krav og vrige relevante krav i direktiv 1999 5 EF del Deutsch German Hiermit erkl rt Name des Herstellers dass sich das Ger t Ger tetyp in bereinstimmung mit den grundlegenden Anforderungen und den brigen einschlagigen Bestimmungen der Richtlinie 1999 5 EG befindet K esolevaga kinnitab tootja nimi name of manufacturer seadme seadme t p type of equipment vastavust direktiivi 1999 5 EU p hin uetele ja nimetatud direktiivist tulenevatele teistele asjakohastele satetele Hereby name of manufacturer declares that this type of equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC les Espanol Spanish Por medio de la presente nombre del fabricante declara que el clase de equipo cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE ME THN MAPOY2A name of manufacturer AHAQNEI OTI type of equipment 2YMMOPQOONETAI MPO2 TI OYZTOAED ATIAITHZEDZ KAI TIX AOITIEZ 2XETIKE2 AJATA ED TH OAHTTA2 1999 5 EK Lr Francais French Par la presente nom du fabricant d clare que l appareil type d appareil est conforme aux e
8. Access Point s MAC address to which you want to extend the wireless area Mode Select Disable or Enable from the drop down list Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 74 Login Setting 9 Management New Name admin New Password 9 1 Administration Confirm Password save Apply Cancel logout This page allows you to change the ECB350 password as well as configure the device by remote access By default the username is i i Remote A admin and the password is admin The password can contain O to E E 12 alohanumeric characters and is case sensitive Hole BEA ee areas er Note Remote Access is only applicable in AP Router and Client Router mode Remote Upgrade Enable o Disable Remote Management Port 8080 Accept Cancel Save Apply Cancel Click Save Apply to apply the changes or Cancel to return previous settings Remote Upgrade Specify whether the firmware of the ECB350 can be upgraded remotely Remote Management Port If remote management is enabled enter the port number to be used for remote management Example If you specify the port number to 8080 enter http lt IP address gt 8080 to access the ECB350 5 9 2 Management VLAN This page allows you to assign a VLAN tag to the packets A VLAN is a group of computers on a network whose software has been configured so to behave as if they were on a separate Local Area Network LAN Compu
9. Address RSSI dBm SS1D1 1 00 02 6f 47 65 ca 40 SSID1 2 00 02 6f 4d f2 1e 36 SID1 49 00 02 6f 11 ac 93 38 Refresh 31 5 5 System Log The ECB350 automatically logs records events of possible interest in its internal memory To view the logged information click the System Log link under the Status menu If there is not enough internal memory to log all events older events are deleted from the log When powered down or rebooted the log will be cleared Syste m Log Home Reset Show log type Al Aug 15 04 55 03 ECB350 user notice root starting ntpclient Aug 15 04 55 01 ECB350 cron err crond 1059 USER root pid 2191 cmd etc hotplug d iface 20 ntpclil Aug 15 04 50 03 ECB350 user notice root starting ntpclient Aug 15 04 50 01 ECB350 cron err crond 1059 USER root pid 1928 cmd etc hotplug d iface 20 ntpcli Aug 15 04 45 40 ECB350 user notice root starting ntpclient Aug 15 04 45 ECB350 daemon crit dnsmasq 1177 bad command line options inconsistent DHCP range Aug 15 04 45 ECB350 daemon crit dnsmasq 1177 FAILED to start up Aug 15 04 45 ECB350 cron err crond 1059 crond busybox 1 15 3 started log level 5 Aug 15 04 45 ECB350 user warn kernel osif vap init wait for connection SM start failed Aug 15 04 45 ECB350 user info kernel device athO entered promiscuous mode Aug 15 04 45 ECB350 user info kernel br lan topology change detected propagating Aug 15 04 45 ECB350 user info kernel br
10. Highlight Ethernet e In Configure IPv4 select Manually e Enter an IP address that is different from the ECB350 and subnet mask then press OK Note Ensure that the IP address and subnet mask are on the same subnet as the device For example ECB350 IP address 192 168 1 1 PC IP address 192 168 1 2 192 168 1 255 enc La PC subnet mask 255 255 255 0 Show Al o Click Apply when done Location Automatic P8 Status Connected System Preferences nm Ethernet is currently active and has the IP e rewire address 192 168 1 100 eo gt Show All Personal Configure IPv4 Manually H4 ig a gt E Lt Ki o IP Address 192 168 1 100 Appearance Desktop amp Dock Expos amp International Securit Subnet Mask 255 255 255 0 Screen Saver Spaces Router Hardware DNS Server A A L WW Ww Search Domains Bluetooth CDs DVDs Displays Energy Keyboard amp Print amp F Saver Mouse Internet Ner e Q a Mac QuickTime Sharing 3 Advanced J O System id Click the lock to prevent further changes Assist me 14 2 4 Hardware Installation 1 Ensure that the computer in use has an Ethernet Controller RJ 45 Ethernet Port For more information verify with your computer user manual 2 Connect one end of the Category 5 Ethernet cable into the RJ 45 port of the ECB350 and the other end to the RJ 45 port of the computer that will use the ECB350 Ensure that the
11. SS Meira 32 Ol OPC LIC MOSS aedium D e O 32 2 ge 33 03 DANIEL Tee e Le E 34 EE ctn 36 LA NAN ST qu qe Sins E eo uit en an Peete tn re ne 36 7 1 1 ee A A ee Te a eee Te UE E aT 36 7 1 2 E cere ee A E EA E ERU eR ie 39 741 3 WEE 41 7 1 4 PRIP PEN POP ER TTD O O UR NORTON NOT E T IERI NORTON SENE NON 43 EE 45 A VENAS TNOU Meer t dM ERE 46 LA slo AA Ee 47 Ji POR LAO WE 49 zs Icd RD E EMEND ME EE LIEU LM 51 JA MACFIE ne ne ee dd 52 Los A o a e 53 LI O A LE US eO MM do GA EN e 55 ERI eer C a 56 S l Wireless NEWO atada dada aes tae eu bd busdam inu deiude E aon eae 56 8 2 WIIeless Selby octets oue ae UI SN e 60 Bo SS DET 63 E WII ess IMIAC ART cl EIE LE 67 A LC EE e E 68 BO NP SWEET us vtae te etie end mime Nee a cu OMM t EM M ND E M TH OT 70 027 EE 72 9 dE Ee DEI VC E 74 SE A PA PP A ADADES 74 GZ Management VAN oa A SAS AAA AAA e ume aa 5 GE ONMP O o OS 76 9 4 BACKUP ROSSO ata 78 95 EN OO AS 79 DOr MMOS e PME ON NP E M pO 80 SO AO Es E 81 GE SS a Le C EO E E C EN ERES 82 OM Glo A o A 83 TAO MOC OUT EE 84 DIL RESO AN nit UMANE A EIL AMA MAMMA MU MI I IM EM 85 Appendix A FCC Interference Statement 5 5 IEEE lid 86 Appendix B IC Interference Statement na EFE INC IQUR animes 87 Appendix CE Interference Statement aiii ee eegen ees 89 4 Revision History Version Date Notes 2012 02 22 1 Introduction The ECB350 is a multi function 802
12. Selected Delete All Reset Accept Cancel 48 Port Forwarding Port Forwarding Enables or disables the Port Forwarding feature 49 7 5 Port Triggering If you use Internet applications which use non standard connections or port numbers you may find that they do not function correctly because they are blocked by the device s firewall Port Triggering will be required for these applications to work AAA A NM AAA ES Port Trigger Table 1 1000 1010 both 1000 1010 bath ruled E Delete Selected Delete All 50 7 0 DMZ If you have a computer that cannot run Internet applications properly from behind the ECB350 you can allow the computer to have unrestricted Internet access Enter the IP address of that computer as a Demilitarized Zone DMZ host with unrestricted Internet access Adding a client to the DMZ may expose that computer to a variety of security risks so use this option as a last resort DMZ Home Reset DMZ Hosting Disable DMZ Address 0 B WU WU Accept Cancel DMZ Hosting Enables or disables the DMZ function DMZ Address Enter an IP Address of the computer that will have unlimited Internet access Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 52 7 7 MAC Filter You can choose whether to Deny or Allow only those devices listed in the MAC Filtering table to access the Internet MAC Filter A ous
13. Table Name Local IP Address Protocol Port Range Select rule 192 168 1 150 192 168 1 151 both 2D 21 1 Delete Selected Delete All Reset 54 Enables or disables the IP Filter function Deny all clients with IP addresses When selected the computers listed in the IP Filter table will be Denied to access listed below to access the network the Internet Allow all clients with IP addresses When selected only the computers listed in the IP Filter table will be Allowed to listed below to access the network access the Internet 55 7 9 URL Filter You can deny access to certain websites by blocking keywords in the URL web address For example gamer has been added to the URL Filter Table Any web address that includes gamer will be blocked URL Filter Home Reset URL Filter Enable Website Keyword test123 Add Cancel URL Filter Table Website Keyword Select 1 Delete Selected Delete All Reset gamer E 56 8 Wireless 8 1 Wireless Network This page displays the current status of the Wireless settings of the ECB350 Access Point WDS AP Router mode Wireless Network leme Reset Wireless Mode 602 11 B G N Mixed Channel HT Mode 20 40MHz Extension Channel Channel Frequency Auto AP Detection Scan Current Profiles SSID Security VID Enable Edit EnGeniusBEEF06 None 1 Edit EnGeniusBEEF06 2 None 2 Edit EnGeniusBEEF06 3 None 3 Edi
14. cable is securely connected to both the ECB350 and the Computer 3 Connect the Power Adaptor DC Inlet to the DC IN port of the ECB350 and the Power Adaptor to the electrical outlet Once both connections are secure verify the following a Ensure that the POWER light is on it will be green b Ensure that the WLAN light is on it will be green C Ensure that the LAN Computer ECB350 Connection light is on it will be green d Once all three lights are on proceed to setting up the computer This diagram depicts the hardware configuration Ethernet Client Bridge AC DC Cable Power Qutlet 15 DC IN for Power LED Lights for Wireless Reset Button Ethernet port and Power Ethernet port for RJ 45 cable Front Panel Rear Panel Ethernet port for RJ 45 cable 16 3 Configuring Your Client Bridge This section will show you how to configure the device using the web based configuration interface 3 1 Default Settings Please use your Ethernet port or wireless network adapter to connect the Client Bridge Default Settings IP Address 192 168 1 1 Username Password Operation Mode Client Bridge 17 3 2 Web Configuration Open a web browser Internet Explorer Firefox Safari and enter the IP Address http 192 168 1 1 Note If you have changed the default LAN IP Address of the Access Point ensure you enter the correct IP Address E Blank Page Windows Internet Exp
15. easily or cannot be hidden from view Older buildings sites with multiple buildings and or areas make the installation of a Wired LAN impossible impractical and or expensive b Temporary Workgroups Create temporary workgroups networks in open areas such as parks athletic arenas exhibition centers temporary offices and construction sites where one wants a temporary Wireless LAN established and easily removed c The Ability to Access Real Time Information Doctors Nurses Point of Sale Employees and or Warehouse Workers can access real time information while dealing with patients serving customers and or processing information d Frequently Changing Environments Set up networks in environments that change frequently i e Show Rooms Exhibits etc e Small Office and Home Office SOHO Networks SOHO users need a cost effective easy and quick installation of a small network f Wireless Extensions to Ethernet Networks Extend network coverage where the network cannot reach i e There is no wired internet connection to reach certain location of the environment g Wired LAN Backup Implement wireless LANs to provide backup for mission critical applications running on wired networks h Training Educational Facilities Training sites at corporations or students at universities use wireless connectivity to ease access to information information exchanges and learning 2 Before you Begin This section will guide you thro
16. in the 2 4 GHz ISM band and using spread spectrum modulation techniques Harmonized EN covering essential requirements under article 3 2 of the R amp TTE Directive EN 301 489 1 V1 8 1 2008 04 Electromagnetic compatibility and Radio Spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 1 Common technical requirements EN 301 489 17 V2 1 1 2009 05 Electromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 17 Specific conditions for 2 4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment This device is a 2 4 GHz wideband transmission system transceiver intended for use in all EU member states and EFTA countries except in France and Italy where restrictive use applies In Italy the end user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and or for supplying public access to telecommunications and or network services 90 This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 2483 5 MHz For detailed information the end user should contact the national spectrum authority in France C 05600 es Cesky Czech Jm no v robce t mto prohla uje
17. lan port 2 ath0 entering learning state Aug 15 04 45 ECB350 user info kernel br lan port 2 ath0 entering forwarding state Aug 15 04 45 ECB350 user warn kernel start running Aug 15 04 45 ECB350 user warn kernel set S5IOC80211NWID 8 characters Aug 15 04 45 ECE350 user warn kernel ieee80211 ioctl setparam parameter 0x35 is not supported Aug 15 04 45 ECB350 user warn kernel ieeeB0211 ioctl setparam parameter 0x21 is not supported Aug 15 04 45 ECB350 user notice root ATH LSDE loaddriver Aug 15 04 45 ECB350 user err kernel VAP device ath created Aug 15 04 45 ECB350 user warn kernel ath get caps 3741 rx chainmask mismatch actual 3 sc chainm Aug 15 04 45 ECB350 user warn kernel ath get caps 3716 tx chainmask mismatch actual 3 sc chainm Aug 15 04 45 ECB350 user info kernel wifi0 Atheros 9280 mem 0x10000000 irq 48 hw base 0xbO0000 4 mt b Ry Bo Po BO Ri Bo Ri Ao Bo Ry Bo Ri Ri Ri BO Ci Gu Cy Ch On Oh Oh a B Ro m OOO fF F hi h3 R3 Qu Refresh Clear System Log 32 6 System 6 1 Operation Mode The ECB350 supports 8 operating modes Access Point Client Bridge WDS AP WDS Bridge WDS Station Universal Repeater Router and Client Router System Properties Home Reset System Properties Device Name ECB350 1 to 32 characters Country Region Please Select a Country Code Ka Access Point Client Bridge o WDS 9 Access Point Operation Mode Bridge _ Station Access Poin
18. to multiple wireless clients In this mode the ECB350 s internal Dynamic Host Configuration Protocol DHCP server automatically allocates ranges of IP addresses to each wireless client that will access the Internet through the ECB350 This mode requires you to connect the ECB350 s Ethernet port to a modem or router And the wireless clients must be configured to use the same SSID and security password to associate with the ECB350 The ECB350 supports up to four SSIDs at the same time for secure guest access K ECB350 AP Router Client 23 4 5 WDS AP WDS Station Mode The ECB350 also supports WDS AP mode This operating mode allows wireless connections to the ECB350 using WDS technology In this mode configure the MAC addresses in both Access Points to enlarge the wireless area by enabling WDS Link settings WDS supports four AP MAC addresses ECB350 Client Computer NS WDS AP ECB350 WDS AP Y Client Computer Client Client Computer ECB350 wosap Y ay ECB350 Client Computer WDS Station Client Note WDS Station Mode does not support Access Point feature 24 4 6 WDS Bridge Mode In WDS Bridge Mode the ECB350 can wirelessly connect different LANs by configuring the MAC address and security settings of each ECB350 device Use this mode when two wired LANs located a small distance apart want to communicate with each other The best solution is to use the ECB350 to
19. your ISP Enter the domain name provided by your ISP MTU Specify the Maximum Transmit Unit MTU size It is recommended that you accept the default setting of Auto Otherwise packets will be fragmented downstream if the MTU is set too high or too low which impacts network performance In extreme cases an MTU setting that is too low can prevent the ECB350 from establishing some connections Get Automatically From Click this radio button to obtain the DNS automatically from the DHCP server ISP Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually Discard Ping on WAN Check to Enable to recognize pings on the ECB350 WAN interface or Disable to block pings on the ECB350 WAN interface Note Pinging IP addresses is a common method used by hackers to test whether the IP address is valid Blocking pings provides extra security from hackers Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 41 7 1 3 PPPoE Select Point to Point Protocol over Ethernet PPPoE if your ISP uses a PPPoE connection Your ISP will provide you with a username and password This selection is typically used for DSL services Remove your PPPoE software from your computer as It is not needed and will not work with your ECB350 WAN Settings __ Home Re Internet Connection Type PPPoE Options MTU Auto 576 1492 PPPoE Options Login Password S
20. 0 Ending IP Address 192 168 B 1i 200 WINS Server IP 0 LU BU BU Accept Cancel Enter the IP address of the WINS server Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 46 7 3 VPN Pass Through The VPN Passthrough allows a secure virtual private network VPN connection between two computers Enabling the options on this page opens a VPN port and enables connections to pass through the ECB350 without interruption VPN Pass Through Dome Reset A PPTP Pass Through 4 L2TP Pass Through 4 IPSec Pass Through Accept Cancel 47 7 4 Port Forwarding Port forwarding can be used to open a port or range of ports to a device on your network Using port forwarding you can set up public services on your network When users from the Internet make certain requests on your network the ECB350 can forward those requests to computers equipped to handle the requests For example if you set the port number 80 HTTP to be forwarded to IP address 192 168 1 150 all HTTP requests from outside users are forwarded to 192 168 1 150 Port Forwarding Home __ Reset Port Forwarding Enable Service Name ruleQ Protocol Both e Starting Port 80 1 65535 Ending Port 80 1 65535 IP Address 192 158 1 150 Add Cancel Port Forwarding Table Name Protocol Start Port End Port Server IP Address Select rule 1 both 20 21 182 168 1 100 F 4 Delete
21. 11b g n product with 8 major multi functions The ECB350 is designed to operate in every working environment including enterprises The ECB350 is a Wireless Network device that delivers up to 6x faster speeds and 7x extended coverage than 802 11b g devices The ECB350 supports use in the home network with superior throughput performance and significant wireless range To protect data during wireless transmissions the ECB350 encrypts all wireless transmissions through WEP data encryption and supports WPA WPA2 encryption The ECB350 has MAC address filtering to allow users to select differing stations to access the network The ECB350 is an ideal product to ensure network safety for both home and enterprise environments 1 1 Features and Benefits Features Benefits High Speed Data Rate Up to 300 Mbps Capable of handling heavy data payloads such as HD multimedia streaming 10 100 1000 Fast Ethernet Support up to 1000Mbps networking speed IEEE 802 11n Draft Compliant and Backwards Fully compatible with IEEE 802 11b g n devices Compatible with 802 11b g devices Multi Function Allowing users to select Access Point Client Bridge WDS AP WDS Bridge WDS Station Universal Repeater Router or Client Router mode in various applications Point to Point or Point to Multipoint Allows transfer of data from building to building Wireless Connectivity Support Multiple SSID in AP mode up to 4 Allow clients to access different networks throu
22. Clicking the Main link under the Status menu or clicking Home at the top right of the ECB350 Page shows the status information about the current operating mode The System Information section shows general system information such as Device Name MAC Address Current Time Firmware Version and Management VLAN ID Note VLAN ID is only applicable in Access Point or WDS AP mode System Information Device Name ECB350 Ethernet Main MAC Address 00 03 7F BE F0 05 Current Time Mon Aug 15 04 48 57 UTC 2011 Firmware Version 1 0 4 Management VLAN ID Untagged The LAN Settings section shows the Local Area Network settings such as the LAN IP Address Subnet Mask and DNS Address LAM Settings IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 Primary DNS 0 0 0 0 Secondary DNS DHCP Client Disabled The WAN Settings section shows WAN setting such as the MAC Address Connection Type Connection Status IP Address Subnet Mask and DNS Address 28 Note WAN Settings is only in Client Router and Router mode WAN Settings MAC Address 00 03 7F BE F0 05 Connection Type Static IP Connection Status Down IP Address IP Subnet Mask 255 255 255 0 Primary DNS 0 0 0 0 Secondary DNS The Current Wireless Settings section shows wireless information such as Operating Mode Frequency and Channel Since the ECB350 supports multiple SSIDs information about each SSID the ESSID and security settings are displayed
23. Discard Ping on WAN Check to Enable to recognize pings on the ECB350 WAN interface or Disable to block pings on the ECB350 WAN interface Note Pinging IP addresses is a common method used by hackers to test whether the IP address is valid Blocking pings provides some extra security from hackers Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 43 7 1 4 PPTP Select PPTP as your WAN connection type if your Internet Service Provider ISP uses a Point to Point Tunneling Protocol PPTP connection You will need to provide the IP address Subnet Mask Default Gateway Optional DNS Optional Server IP Username and Password provided by your ISP WAN Settings Hr co Internet Connection Type PPTP e Options MTU Auto 1200 1400 PPTP Options IP Address 192 168 E10 B 1 Subnet Mask 255 NH 255 B 255 LL Default Gateway 0 Bo LU LL PPTP Server 0 LU B Username Password J Connect on Demand Max idle Time 15 Minutes o Keep Alive Redial Period 30 Seconds Domain Name Server DNS Address 9 Get Automatically From ISP Use These DNS Servers Primary DNS 0 BO Bo B Secondary DNS 0 B Bo B WAM Ping Discard Ping on WAN ES Accept Cancel 44 PPTP Internet Connection Type Select PPTP to begin configuration of the PPTP connection MTU Specify the Maximum Transmit Unit MTU size It is recommended that you accept the default setting of Auto O
24. Ethernet port on your PC to the ECB350 LAN port If you use the client bridge operating mode use the ECB350 Site Survey feature to scan for Access Points within range When you find an Access Point configure the ECB350 to use the same SSID and Security Password as the Access Point to associate with it 3 Access Point Wireless Router e Client Computer ECB350 Client Bridge 20 4 2 Client Router Mode In the Client Router Mode the ECB350 grants Internet access to multiple LANs In this mode the ECB3505 internal Dynamic Host Configuration Protocol DHCP server automatically allocates ranges of IP addresses to each LAN that will access the Internet through the ECB350 This mode requires you to connect the ECB350 wirelessly to an Access Point or Wireless Router and then connect the LANs to the ECB350 using a wired connection Client Computer m a s 3 Access Point Wireless Router ECB350 Client Router Client Computer 21 4 3 Access Point Mode In Access Point Mode ECB350 behaves likes a central connection for stations or clients that support IEEE 802 11b g n networks The stations and clients must be configured to use the same SSID and security password to associate with the ECB350 The ECB350 supports up to four SSIDs at the same time for secure guest access ECB350 Access Point Client 22 4 4 Access Point Router Mode In Access Point Router Mode ECB350 grants Internet access
25. IP Address Assign an IP address Manually IP Subnet Mask Specify an IP address s subnet mask Gateway IP Address Specify the gateway of your network Primary DNS Specify the primary DNS server s IP address Secondary DNS Specify the second DNS server s IP address Discard Ping on WAN Check to Enable to recognize pings on the ECB350 WAN interface or Disable to block pings on the ECB350 WAN interface Note Pinging IP addresses is a common method used by hackers to test whether the IP address is valid Blocking pings provides some extra security from hackers Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings Note Clicking Accept does not apply the changes To apply them use Status Save Load see section 4 1 39 7 1 2 DHCP Select DHCP as your WAN connection type to obtain an IP address automatically You will need to enter the account name as your hostname and optionally enter DNS information WAN Settings Home Reset Internet Connection Type DHCP Options Account Name if required Domain Name if required MTU Auto fi 576 1500 Domain Name Server DH S Address o Get Automatically From ISP Use These DNS Servers Primary DNS 0 Bo g 0 B Secondary DNS 0 0 B BU WAN Ping Discard Ping on WAN El Accept Cancel 40 DHCP Internet Connection Type Select DHCP to begin configuration of the DHCP connection Enter the account name provided by
26. MAC Filter Enable e e Deny all clients with MAC address listed below to access the network O Allow all clients with MAC address listed below to access the network Service Name rule LAN MAC Address 00 n2 BF 03 Kr DA Ada Cancel MAC Filter Table Name MAC Address Select rule01 00 02 6F 11 09 EE E Delete Selected Delete All Reset Accept Cancel MAC Filter MAC Filter Enables or disables the MAC Filter function Deny all clients with MAC addresses When selected the computers listed in the MAC Filter Table will be Denied to access listed below to access the network the Internet Allow all clients with MAC addresses When selected only the computers listed in the MAC Filter table will be Allowed to listed below to access the network access the Internet 53 7 8 IP Filter You can choose whether to Deny or Allow only devices with those IP Addresses listed on the IP Filter Table from accessing certain ports This can be used to control which Internet applications the computers can access Note You will need to have knowledge of which Internet port numbers each application uses IP Filter ome MM Ke IP Filter Enable Deny all clients with IP address listed below to access the network 2 Allow all clients with IP address listed below to access the network Service Name ruleQ Potocol Both e Local IP Address 192 168 171 200 Ca Port Range 80 E 1 65535 Add Cancel IP Filter
27. S operation channels only 8 Appendix B IC Interference Statement Industry Canada statement This device complies with RSS 210 of the Industry Canada Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Ce dispositif est conforme la norme CNR 210 d Industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivantes 1 le dispositif ne doit pas produire de brouillage pr judiciable et 2 ce dispositif doit accepter tout brouillage recu y compris un brouillage susceptible de provoquer un fonctionnement ind sirable IMPORTANT NOTE Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body NOTE IMPORTANTE Pour l utilisation de dispositifs mobiles D claration d exposition aux radiations Cet quipement est conforme aux limites d exposition aux rayonnements IC tablies pour un environnement non contr l Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps This device has been designed to operate with a diople antenna have a maximu
28. addresses appear in the MAC Address table on this page Choices are Disabled Deny MAC in the list or Allow MAC in the list MAC Address Enter the MAC address of the wireless client Add Click Add to add the MAC address to the MAC Address table Delete the selected entries Apply Click Apply to apply the changes 68 8 5 Wireless Advanced This page allows you to configure wireless advance settings It is recommended that the default settings are used unless the user has experience with more advanced networking features Wireless Advanced Settings ES Data Rate Auto M Transmit Power 1f dBm RTSICTS Threshold 1 2346 2346 bytes Distance 1 30km 1 km Aggregation Wireless Traffic Shaping Enable Traffic Shaping Incoming Traffic Limit Qutgoing Traffic Limit Accept Cancel 9 Enable Disable 32 Frames 50000 Bytes Max Enable o Disable kbit s kbit s 69 Wireless Advanced Data Rate Select a data rate from the drop down list The data rate affects throughput of data in the ECB350 The lower the data rate the throughput will be lower but so will the transmission distance Set the power output of the wireless signal RTS CTS Threshold Specify the threshold package size for RTC CTS A small number causes RTS CTS packets to be sent more often and consumes more bandwidth Specify the distance between Access Points and clients Longer distances may drop high speed connections Aggregation M
29. anning Tree Setting This page allows you to modify the Spanning Tree settings Enabling Spanning Tree protocol will prevent network loops in your LAN network Note Only in Access Point Client Bridge WDS AP WDS Bridge WDS Station and Repeater mode Spanning Tree Settings Home Reset Spanning Tree Status i On Off Bridge Hello Time seconds 1 10 Bridge Max Age seconds 6 40 Bridge Forward Delay seconds 4 30 Priority 0 65535 Accept Cancel Spanning Tree Spanning Tree Status Enable or disable the Spanning Tree function Bridge Hello Time Specify Bridge Hello Time in seconds This value determines how often the device sends handshake packets to communicate information about the topology throughout the entire Bridged Local Area Network Bridge Max Age Specify Bridge Max Age in seconds If another bridge in the spanning tree does not send a hello packet for a long period of time it is assumed to be dead Bridge Forward Delay Specify Bridge Forward Delay in seconds Forwarding delay time is the time spent in each of the Listening and Learning states before the Forwarding state is entered This delay is provided 35 so that when a new bridge comes onto a busy network it analyzes data traffic before participating Specify the Priority Number A smaller number has greater priority Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 36
30. been used to authorize connection between the device and wireless clients ssp messi wireless network ane used when connecting wang WPS This is the passphrase key that is randomly generated during the WPS process It is required if wireless clients that do not support WPS attempts to connect to the wireless network Enter the PIN code of the wireless device and click this button to initialize WPS feature using the PIN method 72 8 7 WDS Link Settings Using WDS Wireless Distribution System will allow you to connect to Access Points wirelessly Doing so will extend the wired infrastructure to locations where cabling is not possible or inefficient to implement Note Compatibility between different brands and models of access points is not guaranteed It is recommended that the WDS network be created using the same models for maximum compatibility Also note All Access Points in the WDS network needs to use the same Channel and Security settings To create a WDS network please enter the MAC addresses of the Access Points that you want included in the WDS There can be a maximum of four access points Note Only applicable in WDS AP and WDS Bridge mode WDS Link Settings Home Reset Caution NAWDS was enabled you need assign Wifi Channel manually later ID MAC Address Mode 1 00 202 Bor E Ke B 23 Enable 2 Disable 3 Disable e 4 Disable Accept Cancel 73 WDS Link Settings MAC Address Enter the
31. er to use the ECB350 you must first configure the TCP IPv4 connection of your computer system e Click Start button and open Control Panel Administrator e Internet E 7 My Documents Internet Explorer A s i My Recent Documents 2 E mail EG ES CA Microsoft Office Outlook E My Pictures NAR mm Command Prompt pof rose PE My Computer w Microsoft Office Ward 2003 Control Panel ab Notepad Set Program Access and Defaults IxcChariok Console w Connect Te m Tera Term Pra La Printers and Faxes Microsoft Office Excel 2003 Y Help and Support All Programs gt E Log Off 9 Turn OFF Computer Windows XP e Internet Explorer k EZ Tera Term Pro uim Command Prompt AJ Notepad k J Network Lo Wireshark Connect To Chariot Console Control Panel Devices and Printers CCleaner Run WordPad Kal 7 Zip File Manager e EnGenius Wireless Utility BI Mozilla Firefax k All Programs Windows 7 11 e In Windows XP click Network Connections e Network Connectons e In Windows 7 click View Network Status and Tasks in the Network and Internet section then select Change adapter settings Network and Internet Bu View network status and tasks c Choose homegroup and sharing options Control Panel Home Change adapter settings Change advanced sharing settings e Right click on Local Area Connection and select Properties Local Area Connecto
32. erges data packets into one packet This option reduces the number of packets but increases packet sizes Wireless Traffic Check this option to enable wireless traffic shaping Traffic shaping regulates the flow of packets Shaping leaving an interface to deliver improved Quality of Service Incoming Traffic Limit Specify the wireless transmission speed used for downloading Outgoing Traffic Limit Specify the wireless transmission speed used for uploading Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 70 8 6 WPS Wi Fi Protected Setup Wi Fi Protected Setup WPS feature is following the Wi Fi Alliance WPS standard and it eases the set up of security enabled Wi Fi networks in the home and small office environment It reduces the user steps required to configure a network and supports two methods that are familiar to most consumers to configure a network and enable security Note Only applicable in Access Point WDS AP and Router mode WPS WPS _ Enable o Disable WPS current status Configured Self Pin Code 45998621 55ID EnGeniusBEEFO6 Authentication Mode WPA PSK Mixed TKIP AES Passphrase Key 12245678 WPS Via Push Button WP S Via Pin Accept Cancel 71 Wi Fi Protected Setup WPS wes Select to Enable or Disable the WPS feature WPS Current Status Shows whether the WPS function is Configured or unConfigured When it is Configured the WPS has
33. ervice Mame if required Connect on Demand Max idle Time 1 Minutes o Keep Alive Redial Period 30 Seconds Domain Name Server DNS Address amp Get Automatically From ISP Use These DNS Servers Primary DNS 0 ft bh BU Secondary DNS 0 BU bh BU WAN Ping Discard Ping on WAN El Accept Cancel 42 PPPoE Internet Connection Type Select PPPoE to begin configuration of the PPPoE connection MTU Specify the Maximum Transmit Unit MTU size It is recommended you accept the default setting of Auto Otherwise packets will be fragmented downstream if the MTU is set too high or too low which impacts network performance In extreme cases an MTU setting that is too low can prevent the ECB350 from establishing some connections Enter the Username provided by your ISP Password Enter the Password provided by your ISP Enter the Service Name provided by your ISP Connect on Demand Select the radio button to specify the maximum idle time Internet connection will disconnect when it reach the maximum idle time but it will automatically connect when user tries to access the network Keep Alive Select whether to keep the Internet connection always on or enter a redial period once the internet lose connection Get Automatically From ISP Click this radio button to obtain the DNS automatically from the DHCP server Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually
34. gh a single access point and assign different policies and functions for each SSID through the built in software WPA WPA2 IEEE 802 1x Support Powerful data security User Isolation Support AP mode Protect the private network between client users Power over Ethernet IEEE802 3af Flexible Access Point locations Save User Settings Firmware upgrade does not delete user settings QoS WMM support Enhanced user performance and density SNMP Remote Configuration Management Allows remote connection to configure or manage the ECB350 easily 1 2 Package Contents The ECB350 package contains the following items all items must be in package to issue a refund ECB350 Wireless Long Range Multi Function CB AP 12V 1A 100V 240V Power Adapter RJ 45 Ethernet LAN Cable CD ROM with User s Manual Quick User Guide 1 3 System Requirements The following are the minimum system requirements in order configure the device e Computer with an Ethernet interface or Wireless Network function e Windows OS XP Vista 7 Mac OS or Linux based operating systems e Web Browsing Application Le Internet Explorer FireFox Safari or other similar software 1 4 Applications Wireless LAN products are easy to install and highly efficient The following list describes some of the many applications made possible through the power and flexibility of wireless LANs a Difficult to Wire Environments There are many situations where wires cannot be laid
35. igure the ECB350 s security modes WEP WPA PSK WPA2 PSK WPA PSK Mixed WPA WPA2 and WPA Mixed We strongly recommend you use WPA2 PSK WEP Encryption Wireless Security Security Mode WEP gt Auth Type Open System e Input Type Hex Key Length 40 64 bit 10 hex digits or 5 ASCII char Default Key 1 e Key1 1234567890 Key2 Key3 Key4 WEP Encryption Auth Type Select Open System or Shared Key Input type ASCII Regular Text recommended HEX Hexadecimal Numbers For advanced users Key Length Select the desired option and ensure the wireless clients use the same setting Choices are 64 128 152 bit password lengths Default Key Select the key you wish to be default Transmitted data is ALWAYS encrypted using the Default Key the other Keys are for decryption only 61 You must enter a Key Value for the Default Key Encryption Key Enter the key value or values you wish to use Only the Key selected as Default is required The others are optional WPA PSK WPA Pre Shared Key Encryption Wireless Security Security Mode WPA PSK Mixed Encryption Both TKIP AES pias 12345678 8 to 63 characters or 64 Hexadecimal characters Group Key Update Interval 3600 seconds 30 3600 0 disabled WPA PSK WPA Pre Shared Key Encryption Encryption Select the WPA encryption type you would like Please ensure that your wireless clients use the same settings Passphrase Wireless clients must use the same key to as
36. ing Please wait 3 The ECB350 will list the available access points after site survey Site Survey 2GHz Site Survey Infrastructure Z Ad hoc BSSID SSID Channel Signal Level Type Security Mode 00 02 6F B9 3A 30 SQA ADSL 1 66 dBm 11g n WPA2 PSK i 00 0C F6 54 49 79 6 72 dBm 1ig n WPA2 PSK H 00 02 6F 3C 3D 84 EnGenius9C3D84 11 85 dBm 11bg WPA PSK 4 00 03 7F BE F 2 25 ADDA TEST 11 84 dBm 110 n WPA WPA2 PSK H 00 03 7EBEFO CO TAF RT 11 52 dBm 11gin WPA2 PSK i 00 02 6F 10 10 14 EnGenius 38 dBm 119 n WPA2 PSK H 00 02 6F 51 F9 38 EnGenius51F9338 11 T9 dBm 1ig n none A 00 02 6F B3 4F 38 SENAOWL 1 83 dBm 11g n WEP H 00 02 6F 6D 0B EF yenger 4 83 dBm 11b g WEP H 06 03 7F BE F1 1D EnGenius 6 89 dBm 1ig n none H 00 31B31 62 71 C3 dlink 2 90 dBm 11g n none A 00 40 05 C 7 49 4C default 6 90 dBm 11b none A Refresh 65 4 Select an Access Point and click that Access Point s BSSID Site Survey 2GHz Site Survey Infrastructure Z Ad hoc BSSID SSID Channel Signal Level Type Security Mode 00 02 6F B9 3A 30 SQA ADSL 1 66 dBm 119 n WPA2 PSK i 00 0C F6 54 A9 79 6 72 dBm 1igin WPA2 PSK i 00 02 6F 9C 3D 84 EnGenius9C3D84 11 85 dBm 11big WPA PSK i 00 03 7F BE F2 25 ADDA TEST 11 84 dBm 11gin WPAIWPA2 P SK i 00 03 7F BE FO CO Bes E b 11 52 d m 11gin WPA2 PSK i 00 02 6F 10 10 14 EnGenius 4 38 dBm 119 n WPA2 P SK i 00 02 6F 51 F9 38 EnGenius51F938 11 79 dBm 11gin none D 00 02 6F B3 4F 38 SENAOWL 1 83 dB
37. ings Home Reset Save A Copy of Current Settings Restore Saved Settings from A File Revert to Factory Default Settings Backup Restore Save A Copy of Current Click Backup to save the current configured settings Settings Restore Saved Settings To restore settings that have been previously backed up click Browse select the from A File file and click Restore Revert to Factory Default Click Factory Default button to restore the ECB350 to its factory default settings Settings 79 9 5 Firmware Upgrade This page allows you to upgrade the firmware of the ECB350 Firmware Upgrade MODE Reset Current firmware version 1 0 4 Locate and select the upgrade file from your hard disk Upload To perform the Firmware Upgrade 1 Click the Browse button and navigate the OS File System to the location of the upgrade file 2 Select the upgrade file The name of the file will appear in the Upgrade File field 3 Click the Upload button to commence the firmware upgrade Note The device is unavailable during the upgrade process and must restart when the upgrade is completed Any connections to or through the device will be lost 80 9 6 Time Setting This page allows you to set the internal clock of the ECB350 Time Settings Home Reset Time Manually Set Date and Time i 9 Automatically Get Date and Time Time Zone UTC 00 00 Gambia Liberia Morocco User defined NTP Server 2096197 Save Apply Cancel
38. lore e amp SC BI http 192 16811 e The default username and password are admin Once you have entered the correct username and password click the Login button to open the web base configuration page EnGenius Username admin Password seses Login 18 If successful you will be logging in and see the ECB350 User Menu EnGenius Main System Information Device Name Ethernet Main MAC Address Current Time Firmware Version LAN Settings IP Address Subnet Mask Default Gateway Primary DNS Secondary DNS DHCP Client Current Wireless Settings Operation Mode Wireless Mode Channel Bandwidth Frequency Channel Wireless Network Name SSID Security Spanning Tree Protocol Home ECB350 00 03 7F BE F0 05 Mon Aug 15 05 25 36 UTC 2011 1 0 4 192 168 1 1 255 255 255 0 192 168 1 1 0 0 0 0 Disabled Client Bridge IEEE 802 11b g n Mixed 20 40 MHz 2 422 GHz Channel 3 AP SSID None Disabled 1 Km Reset 19 4 Building a Wireless Network The ECB350 has the ability to operate in various operating modes The ECB350 is the ideal device in which you can build your WLAN This chapter describes how to build a WLAN around your ECB350 using the operating modes of the ECB350 4 1 Client Bridge Mode In Client Bridge Mode the ECB350 acts as a wireless dongle that connects to an Access Point to allow a system wireless access to the network This mode requires you to connect the
39. m 119 n WEP i 00 02 6F 6D 0B EF yenger 4 83 dBm 11b g WEP i 06 03 7F BE F1 1D EnGenius2 6 89 dBm 11gin none i 00 18 11 62 71 03 dlink 2 90 dBm 119 n none i 00 40 05 C7 49 4C default 6 90 dBm 11b none El Refresh 66 5 Enter the correct security setting Wireless Network am tome Reset Wireless Mode 002 11 B G N Mixed Specify the static SSID EnGenius 1 to 32 characters SSID Or press the button to search for any available WLAN Service site Survey Prefered BSSID E Wireless Security Changing the wireless security settings may cause this wireless client to associate with a different one This may temporarily disrupt your configuration session Security Mode WPA2 PSK Encryption AES Passphrase 12345678 8 to 63 characters or 64 Hexadecimal characters Accept Cancel 67 8 4 Wireless MAC Filter Wireless MAC Filters are used to allow or deny network access to wireless clients according to their MAC addresses You can manually add a MAC address to restrict the permission to access ECB350 The default setting is Disable Wireless MAC Filter Note Only applicable in Access Point WDS AP and Router mode Wireless MAC Filter Home Reset ACL Mode Disabled 00 02 et 00 35 01 Add MAC Address 1 00 02 6F 00 35 04 Delete Accept Wireless Filter Access Point WDS AP Router mode ACL Mode Determines whether network access is granted or denied to clients whose MAC
40. m gain of 5 dB Antenna having a higher gain is strictly prohibited per regulations of Industry Canada The required antenna impedance is 50 ohms Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter IC 10103A ECB350 Model ECB350 has been approved by Industry Canada to operate with the antenna type maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this user s manual having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device 88 Ce dispositif a t concu pour fonctionner avec une antenne ayant un gain maximal de diople antenne avec dB 5 Une antenne gain plus lev est strictement interdite par les r glements d Industrie Canada L imp dance d antenne requise est de 50 ohms Conform ment la r glementation d Industrie Canada le pr sent metteur radio peutfonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pourl metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio
41. n Create Shortcut Delete Rename 12 M 0 Client for Microsoft Networks M Bo Packet Scheduler M 2 File and Printer Sharing for Microsoft Networks Select Internet Protocol Version 4 TCP IPvA and then 4 Intemet Protocol Version 6 TCP 1Pv6 select Properties M AIR Protocol Version 4 TCP IPv4 wi 4 Link Layer Topology Discovery Mapper 1 O Driver W A Link Layer Topology Discovery Responder Internet Protocol Version 4 TCP IPv4 Properties e Select Use the following IP address and enter an IP address that is different from the ECB350 and subnet mask then click OK General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator Note Ensure that the IP address and subnet mask are on the same subnet as ha ipn El UE is the device Obtain an IP address automatically For example ECB350 IP address 192 168 1 1 IP address 192 168 1 10 PC IP address 192 168 1 2 192 168 1 255 cic rU DT PC subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server E Validate settings upon exit Advanced 13 2 3 Apple Mac X OS Goto System Preferences can be opened in the Applications folder or selecting it in the Apple Menu e Select Network in the Internet amp Network section e
42. niami Dyrektywy 1999 5 EC Nome do fabricante declara que este tipo de equipamento est conforme com os requisitos essenciais e outras disposi es da Directiva 1999 5 CE Ime proizvajalca izjavlja da je ta tip opreme v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo ili direktive 1999 5 ES Meno v robcu t mto vyhlasuje Ze typ zariadenia spi a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 1999 5 ES ti Suomi Finnish Valmistaja manufacturer vakuuttaa taten etta type of equipment laitteen tyyppimerkint tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen sl Svenska Swedish H rmed intygar f retag att denna utrustningstyp star I verensst mmelse med de vasentliga egenskapskrav och vriga relevanta bestammelser som framgar av direktiv 1999 5 EG
43. ol data units to be sent to various parts of the network Upon receiving these messages SNMP compatible devices called agents return the data stored in their Management Information Bases SNMP Settings Home Reset SNMP o Enable Disable Contact Location Community Name Read Only public Community Name Read Write private Trap Destination Address Trap Destination Community Name Save Apply Cancel SNMP Enable Disable Enable or Disable SNMP feature Contact Specify the contact details of the device Location Specify the location of the device Community Name Read Specify the password for the SNMP community for read only access Only 17 Community Name Specify the password for the SNMP community with read write access Read Write Trap Destination Address Specify the IP address of the computer that will receive the SNMP traps Trap Destination Specify the password for the SNMP trap community Community Name 78 9 4 Backup Restore This page allows you to save the current device configurations When you save the configurations you also can reload the saved configurations into the device through the Restore Saved Settings from A File section If extreme problems occur or if the you have set the ECB350 wrongly you can use the Factory Default button in the Revert to Factory Default Settings section to restore all the configurations of the ECB350 to the original default settings Backup Restore Sett
44. opriate radio button to allow or prevent communication between client devices Wireless Security See the Wireless Security section Save Cancel Click Save to accept the changes or Cancel to cancel and return previous settings 59 Client Bridge Client Router WDS Station Repeater mode Wireless Network Lome Reset Wireless Mode 602 11 B G N Mixed Specify the static SSID AP SSID 1 to 32 characters SSID Or press the button to search for any available WLAN Service Prefered BSSID E Wireless Security Changing the wireless security settings may cause this wireless client to associate with a different one This may temporarily disrupt your configuration session Security Mode Disabled Accept Cancel Wireless Mode Wireless mode supports 802 11b g n mixed mode The SSID is a unique named shared amongst all the points of the wireless network The SSID must be identical on all points of the wireless network and cannot exceed 32 characters You may specify an SSID or select one from the Site Survey Site Survey Click on Site Survey to search the existing Access Points Preferred BSSID Specify the BSSID Access Point s MAC Address Wireless Security The encryption is using It must the same as Access Point s encryption Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 60 8 2 Wireless Security The Wireless Security section lets you conf
45. rmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This transmitter must not be co located or operating in conjunction with any other antenna or transmitter IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body Note The country code selection is for non US model only and is not available to all US model Per FCC regulation all WiFi product marketed in US must fixed to U
46. sociate the device If using passphrase format the Key must be from 8 to 63 characters in length Group Key Update Interval Specify how often in seconds the group key changes 62 WPA Encryption Only in Access Point WDS AP Router mode Wireless Security Security Mode WPA Mixed Encryption Both TKIP AES Radius Serer Radius Port 1812 Group Key Update Interval 3600 seconds 30 3600 0 disabled WPA Encryption Encryption Select the WPA encryption type you would like Please ensure that your wireless clients use the same settings Specify how often in seconds the group key changes Note 802 11n does not allow WEP WPA PSK TKIP WPA2 PSK TKIP security mode The connection mode will automatically change from 802 11n to 802 11g 63 8 3 Site Survey Use this feature to scan nearby Access Points Note Only applicable in Client Bridge Client Router or Repeater modes 1 Click Site Survey Wireless Network Home Reset Wireless Mode 802 11 B G N Mixed Specify the static SSID AP SSID 1 to 32 characters Or press the button to search for any available WLAM Service Site Survey SSID Prefered BSSID Wireless Security Changing the wireless security settings may cause this wireless client to associate with a different one This may temporarily disrupt your configuration session Security Mode Disabled Accept Cancel 64 2 Scanning the nearby Access Points Scann
47. t EnGeniusBEEF06 4 None 4 o Wo Isolation Profile 5 SID Isolation Isolate all Profiles SSIDs from each other using VLAN 802 1Q standard CAUTION No Management VLAN ID Packet only allow on Primary Ethernet Port Accept Cancel 5 Wireless Network Access Point WDS AP Router mode Wireless Mode Wireless mode supports 802 11b g n mixed mode Channel HT Mode The default channel bandwidth is 20 40MHz The larger the channel the better the transmission quality and speed Current Profile Configure up to four different SSIDs If many client devices will be accessing the network you can arrange the devices into SSID groups Click Edit to configure the profile and check whether you want to enable extra SSID Profile Isolation Restricted client to communicate with different VID by selecting the radio button Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 58 SSID Profile SSID Profile Wireless Setting SSID EnGeniusBEEFO6 1 to 32 characters VLAN ID 1 1 4094 Suppressed SSID lal Station Separation Enable a Disable Wireless Security Security Mode Disabled M Save Cancel SSID Profile Specify the SSID for the current profile VLAN ID Specify the VLAN tag for the current profile Suppressed SSID Check this option to hide the SSID from clients If checked the SSID will not appear in the site survey Station Separation Click the appr
48. t Router Client Router Repeater Save Apply Cancel System Properties Device Name Enter a name for the device The name you type appears in SNMP management This name is not the SSID and is not broadcast to other devices Country Region Select a Country Region to conform to local regulations Operation Mode Use the radio button to select an operating mode Save amp Apply Cancel Click Save amp Apply to confirm the changes or Cancel to cancel and return previous settings 33 6 2 IP Settings This page allows you to modify the device s IP settings Note Only applicable in Access Point Client Bridge WDS AP WDS Bridge WDS Station and Repeater mode IP Settings ee ee System Information _ Obtain an IP address automatically DHCP nee 9 Specify an IP address IP Address 192 Dies Bi B IP Subnet Mask 255 Mass 255 Po Default Gateway 192 168 Ai Primary DNS 0 BU BO BO Secondary DNS 0 NO E go Accept Cancel IP Network Setting Select whether the device IP address will use the static IP address specified in the IP Address field or be obtained automatically when the device connects to a DHCP server IP Address The IP Address of this device IP Subnet Mask The IP Subnet Mask of this device Default Gateway The Default Gateway of this device Leave it blank if you are unsure of this setting Primary Secondary DNS The primary secondary DNS address for this device 6 3 Sp
49. ters on a VLAN do not have to be physically located next to one another on the LAN Note Only applicable in Access Point and WDS AP mode Management VLAN Settings Home Reset Caution If you reconfigure the Management VLAN ID you may lose connectivity to the access point Verify that the switch and DHCP server can support the reconfigured VLAN ID and then re connect to the new IP address 9 No VLAN tag Management VLAN ID Specified VLAN ID must be in the range 1 4094 Accept Cancel Management VLAN Only applicable in Access Point mode Management VLAN ID If your network includes VLANs you can specify a VLAN ID for packets pass through the Access Point with a tag Otherwise select No VLAN tag Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings Note 1 If you reconfigure the Management VLAN ID you may lose your connection to the ECB350 Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the ECB350 using the new IP address 2 Clicking Accept does not apply the changes To apply them use Status Save Load see section 4 1 76 9 3 SNMP Settings This page allows you to assign the Contact Details Location Community Name and Trap Settings for Simple Network Management Protocol SNMP This is a networking management protocol used to monitor network attached devices SNMP allows messages called protoc
50. therwise packets will be fragmented downstream if the MTU is set too high or too low which impacts network performance In extreme cases an MTU setting that is too low can prevent the ECB350 from establishing some connections Connect on Demand Select the radio button to specify the maximum idle time Internet connection will disconnect when it reach the maximum idle time but it will automatically connect when user tries to access the network Keep Alive Select whether to keep the Internet connection always on or enter a redial period once the internet loses connection Get Automatically From ISP Click this radio button to obtain the DNS automatically from the DHCP server Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually Discard Ping on WAN Check to Enable to recognize pings on the ECB350 WAN interface or Disable to block pings on the ECB350 WAN interface Note Pinging IP addresses is a common method used by hackers to test whether the IP address is valid Blocking pings provides some extra security from hackers Accept Cancel Click Accept to confirm the changes or Cancel to cancel and return previous settings 45 7 2 LAN Settings This page allows you to modify the device s LAN settings LAN Settings ee n ose LAH IP Setup IP Address 192 168 B 1 B 1 IP Subnet Mask 255 NH 55 B 55 BU 4 Use Router As DHCP Server Starting IP Address 192 BH 166 B 1 B 10
51. ugh the installation process Placement of the ENGENIUS ECB350 is essential to maximize the ECB350 s performance Avoid placing the ECB350 in an enclosed space such as a closet cabinet or wardrobe 2 1 Considerations for Wireless Installation The operating distance of all wireless devices cannot be pre determined due to a number of unknown obstacles in the environment that the device is deployed in These could be the number thickness and location of walls ceilings or other objects that the ECB350 s wireless signals must pass through Here are some key guidelines to allow the ECB350 to have optimal wireless range e Keep the number of walls and or ceilings between the ECB350 and other network devices to a minimum Each wall and or ceiling can reduce the signal strength resulting in lower signal strength e Building materials makes a difference A solid metal door and or aluminum stubs may have a significant negative effect on the signal strength of the ECB350 Locate your wireless devices carefully so the signal can pass through a drywall and or open doorways Materials such as glass steel metal concrete water example fish tanks mirrors file cabinets and or brick can also lower your wireless signal strength e Interferences can also come from your other electrical devices and or appliances that generate RF noise The most usual types are microwaves or cordless phones 10 2 2 Computer Settings Windows XP Windows 7 In ord
52. wirelessly connect two wired LANs as shown in the following figure WDS Bridge Mode can establish four WDS links creating a star like network REIS ECB350 Client Computer WDS Bridge e Client Computer ECB350 WDS Bridge Us ECB350 Client Computer WDS Bridge Note WDS Bridge Mode does not act as an Access Point Access Points linked by WDS are using the same frequency channel More Access Points connected together may lower throughput Please be aware to avoid loops in your wireless connection otherwise enable Spanning Tree Function 25 4 7 Repeater mode Repeater is used to regenerate or replicate signals that are weakened or distorted by transmission over long distances and through areas with high levels of electromagnetic interference EMI 7 3 Access Point Wireless Router 3 ECB350 Client Repeater 26 5 Status The Status section contains the following options Main Wireless Client List and System Log The following sections describe these options 5 1 Save Reload This page lets you save and apply the settings shown under Unsaved changes list or cancel the unsaved changes and revert them to the previous settings that were in effect Save Reload Home Reset f ssid EnGenius f encryption psk2 aes tf key 12345678 f basid 00 02 6F 10 10 14 SE WOScompatibleMTEK 0 T8f PreferBS5SIDEnable 3 1 10 channel 1 Save Apply Revert 2 5 2 Main
53. xigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Italiano Italian Con la presente nome del costruttore dichiara che questo tipo di apparecchio e conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE tl Eesti Estonian lel EAAnvikn Greek 91 Latviski Latvian Ar So name of manufacturer izgatavotaja nosaukums deklare ka type of equipment iekartas tips atbilst Direktivas 1999 5 EK b tiskajam prasibam un citiem ar to saistitajiem noteikumiem Lietuviy Lithuanian Siuo manufacturer name deklaruoja kad 3is equipment type atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas nll Nederlands Dutch Hierbij verklaart naam van de fabrikant dat het toestel type van toestel in overeenstemming is met de essenti le eisen en de andere relevante bepalingen van richtlijn 1999 5 EG mt Malti Maltese Hawnhekk isem tal manifattur jiddikjara li dan il mudel tal prodott jikkonforma mal htigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid Dirrettiva 1999 5 EC I Magyar Hungarian Alul rott gy rt neve nyilatkozom hogy a tipus megfelel a vonatkoz alapvet k vetelm nyeknek s az 1999 5 EC ir nyelv egy b eldirasainak Niniejszym nazwa producenta o wiadcza ze nazwa wyrobu jest zgodny z zasadniczymi wymogami oraz pozosta ymi stosownymi postanowie