1. VATES Poron VIP 130L IP Paging Horn INTRODUCTION The VIP 130L IP Paging Horn is a self contained paging system which enables voice paging up to 1200 feet from an Ethernet connection The VIP 130L consists of a high efficiency 5 Watt Class D Horn and a VIP LLE Network Extender allowing stand alone capability when used with a SIP enabled telephone system or can be accessed from a variety of Valcom managed VolP products SPECIFICATIONS Access Methods e PBX FXO Port w VIP 811 POTS telephone set w VIP 81 1 PBX FXS Port w VIP 821 Valcom M Cast Page Group SIP telephone system Features e RJ 45 network connection LED Status Indicator Network activity LEDs Power over Ethernet PoE 802 3af compatible High Efficiency Class D 5 Watt Amplifier Dimensions Weight Horn e 7 00 H x 10 00 W x 10 00 D 18 75 cm H x 25 4 cm W x 26 4 cm D e Weight 5 8 Ibs 2 63 kg Network Extender VIP LLE e 1 30 H x 6 10 W x 6 00 D 3 51 cm H x 15 72 cm W x 13 51 cm D e Weight 0 85 lbs 0 39 kg Environment Temperature Humidity 0 to 40 C 0 to 85 non precipitating ISSUE 5 Nominal Specifications HORN Input Impedance 600 Ohms Input Level 10dBm Output Impedance 600 Ohms Output Level 10dBm nominal Nominal Specifications VIP LLE Via 802 3af PoE Ethernet Switch Class 3 Packing List Qty item C Clamp INSTALLATION FCC Information This equipment has been tested and found
2. The IP connections are made on the rear panel of the VIP Solutions Setup Tool may be downloaded from the LLE Network Extender Versions of the VIP LLE Valcom website at www valcom com Network Extender with the color coded 8 pin screw connector will connect standard CAT 5 twisted pair TECHNICAL ASSISTANCE cable from the rear panel color coded connector of Assistance is available from the factory when the VIP LLE Network Extender to the supplied VM problems are encountered Call 540 563 2000 and 186 RJ 45 connector 900 feet maximum distance press 1 for Technical Support or visit our website at Connect RJ 45 connector of horn to VM 186 RJ 45 http www valcom com socket For versions of the VIP LLE Network Extender with the RJ 45 Audio Output connector the horn may be connected directly to the RJ 45 port If additional length is required any standard T568A or T568B extension may be used 900 feet maximum Valcom equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs be necessary attach a tag to the unit clearly stating your company name address phone number contact person and the nature of the problem Send the unit to Status Indicator Lights Valcom Inc The VIP LLE Network Extender has 3 status Repair amp Return Dept indication lights 5614 Hollins Road Roanoke VA 24019 VALCOM LIMITED WARRANTY Valcom Inc warrants its products only to the original purchas
3. NGE 802 3af Compliant PoE Network Port pa De WHITE ORANGE BLUE ea BLUE WBL WO WGN WBR WHITE BLUE v i SEE a WHITE BLUE i BLUE a g VM 186 Rear View with Terminal t a ee Henna anen tt Note The Brown and White brown pair should TOR ANGE be twisted together and inserted into the NOT USED E connector noted on the drawing and the Green and White Green pair should also be twisted 5 together and inserted into the connector that is 900 MAX DISTANCE CAT 3 5 6 noted on the drawing Figure 3 AUDIO OUTPUT o Rear View with RJ 45 Connector Figure 4 IP Paging Horn 4 947628
4. ded secure the VIP LLE Network Extender to the wall Mounting HORN The horn should be mounted 15 to 20 feet above the floor to allow for best sound distribution The unit can be mounted to a wall a beam or an electrical box NOTE For ease of installation the base can be attached to the speaker before or after the base is mounted e Loosen position adjustment knob e Insert the ball of the base into the socket of the speaker e Tighten the position adjustment knob e Mount the base to a wall using the two pre drilled holes provided e A C clamp is provided with the horn to allow mounting to a beam Place the bolt through the hole in the bottom of the base to secure the C clamp to the beam It is suggested that the horn be mounted to the underside of the I beam to provide maximum positioning adjustments e The base has pre drilled holes for a double gang square electrical box but by drilling out additional knockout holes the base can be mounted to a single gang or octagon box The horn may be rotated or moved up and down to obtain the desired position by loosening the position adjustment knob at the bottom of the unit approximately one turn Make required adjustments and re tighten knob Position Adjustment Knob Figure 1 Mounting to a Beam with a C Clamp Electrical z m b A a Mi a S9 p i Position 3 Adjustment peaker Knob Base Figure 2 Moun
5. er for its own use to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment This Limited Warranty obligation shall be limited to the replacement repair or refund of any such defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been altered in any way or repaired by others and that factory sealed units are unopened a service charge plus parts and labor will be applied to units defaced or physically damaged 4 freight charges for the return of products to Valcom are prepaid 5 all units out of warranty are subject to a service charge The service charge will cover minor repairs major repairs will be subject to additional charges for parts and labor This Limited Warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be liable for any anticipated profits consequential damages loss of time or other losses incurred by the buyer in connection with the purchase operation maintenance installation removal_or use of the product The maximum liability of Valcom under this warranty is limited to the purchase price of the specific Product covered by the warranty Disclaimer Except for the Limited Warranty pr
6. ovided herein the product is provided as is without any warranty of any kind whatsoever including without limitation any WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT This warranty specifically excludes damage incurred in shipment In the event a product is received in damaged condition the carrier should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the F O B point Headquarters Valcom Inc 5614 Hollins Road Roanoke VA 24019 5056 Phone 540 563 2000 FAX 540 362 9800 3 947628 Note The screw terminals are removable Gently lift away from the circuit board to remove Make the necessary wire connections HY Paging Horn then replace the screw terminals over the pins RJ45 on circuit board S Front View A a BROWN VALCOM BROWN WHITE BROWN Status WHITE BROWN a GREEN Link S E Act GREEN La WHITE GREEN WHITE GREEN dal ORA
7. ting to an Electrical Backbox 947628 Interconnections STATUS Flashes during normal operation and solid The only method of powering the VIP 130L IP Paging when unit in reset Horn is via a Power over Ethernet PoE switch or power injector meeting the 802 3af specification LINK Indicates 100 Mbit Ethernet connection when illuminated No activity indicates 10 Mbit connection Make all required signal connections before connecting to Ethernet switch or power injector meeting the 802 3af specification Power is supplied Act Indicator flashes to indicate network activity to the horn assembly via the VIP LLE Network Operation Extender Provide paging from SIP connection or via a variety of Valcom managed VoIP products Integration to Network Connection customer telephone system can be via SIP As shown in Figure 3 the VIP LLE Network Extender registration FXO port with VIP 811 or FXS port has one RJ 45 network connector on the front panel with VIP 821 Use a standard Ethernet patch cable to connect the Set NETWORK connector of the VIP LLE Network up Extender to a 802 3af compliant PoE port 300 feet Information specific to your application will need to be maximum distance programmed into the VIP 130L using a computer The PC used for programming would be connected to Sianal Connections the same subnet as the VIP 130L Setup will be reece in Figure 3 and 4 audio output done using the IP Solutions Setup Tool
8. to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the 947628 instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense Precautionary Designations CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION To reduce the risk of electric shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit Mounting VIP LLE The VIP LLE Network Extender is designed for wall or shelf mounting and must be within 300 feet of the network switch Shelf Provided with the VIP LLE Network Extender are four rubber pads Peel the pads from the carrier backing and place at the four corners of the bottom of the unit Wall Using the brackets and wood screws provi