Home
CyberPower BP48V75ART2UTAA uninterruptible power supply (UPS)
Contents
1. CyberPower JETA Quality Value User s Manual BATTERY PACK BP48V75ART2U CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403 0009 www CPSww com K01 0000077 01 CyberPower Reliability Quality Value Content INTRODUCTION nee seen ETT 2 OVERVIEW conri nee 2 UNPACKING ers 2 BASIGOPERATION A nes an 2 INSTALLATION GUIDE an 2 BATTERY CONNECTION TO UPS a ae 4 TECHNICAL SPECIFICATIONS 020205502000 venere nooo ooo nennen 5 TROUBLE SHOOTING A SB sense nora so aodas ido sap a o NenOa essen see Sas 4 CUSTOMER SERVICE vccicvcsvccsansaectucnsicsesesssesserisacunsunsueaguenssesssussscancnsencas 5 PRODUCT REGISTRATION fo s ccccessccessssnonercvercescasuasesancsrecessosscousevasaer ses 6 PRODUCT WARRANTY siccrscsasencscoseessanstsunssersconssesasansiecnaertnonsosscssaveasmacnes 6 CONFORMANCE APPROVALG cccsscccsssseeccesceccesceccccssceccssescceseeseeees 8 1 Copyright 2008 CyberPower Systems Inc CyberPower Reliability Quality Value Introduction Overview The CyberPower external battery pack BP48V75ART2U supports 75A polarized plugs and is designed for variety of CyberPower UPS systems When combining with the UPS the battery pack provides extended runtime with a 48V DC external connection Additional parallel connected battery packs provides the UPS for a longer extended runtime operation Unpacking 2 Rack mount bracket
2. ACINPUT 0 0 0 L J A Change Only gt 88 E 87 A N IN Push To gt 0 0 gt ES AZ H Reser zu o o o o TTERY a Pack 00000 w N D 66 86 66 y o o e ACOUTPUT ACINPUT O 0 0 d er Change Only e Copyright O 2008 CyberPower Systems Inc CyberPower Reliability Quality Value Refer to the battery connection diagram 1 Connect the battery pack s output cord into the UPS s input port 2 All battery pack module must connect in right type red to red black to black green to green 3 When connecting with numerous battery packs to extend the battery runtime link the output plugs of all except the one that connects to the UPS CAUTION If AC input charger of battery pack from UPS outlet output it will occupy UPS output rating Battery Charger Consumption 100VA approximate per battery pack CAUTION Before connecting to the UPS make sure to turn off the circuit breaker CAUTION Do not disconnect the battery pack when UPS is operating CAUTION Do not connect the battery pack into itself CAUTION Additional battery packs are to be connected in parallel connected the voltage maintains the same yet the battery amp hour capacity depends on the numbers of battery packs in the set up CAUTION Do not connect more than the upper limit of the battery packs to the UPS The battery packs limits are stated in the user s manual Battery Connection to UPS How to set
3. d to protect any Connected Equipment CyberPower will also send you forms for making your claim for the Connected Equipment CyberPower will repair or replace the equipment that was damaged because of the failure of the Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage CyberPower will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount CyberPower s maximum liability is limited to the dollar amount as specified in the Technical Specifications Warranty section of the User s Manual Shipping Packaging CyberPower will pay when shipping items to you you will pay when shipping items to CyberPower Filing a Claim All claims must be made within ten days of the occurrence Please have the following information available when contacting CyberPower Product model number Product serial number Date of Purchase and a list of item s that you have connected to the CyberPower Product Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number A dated Proof of Purchase receipt or other proof of the original purchase must be provided Copyright O 2008 CyberPower Systems Inc CyberPower Reliability Quality Value Please be prepared to provide a description of the defect and when i
4. different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction The Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class B respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada Need Additional Help Feel free to contact our Tech Support department with installation troubleshooting or general product questions CyberPower Technical Support Phone 1 877 297 6937 Email tech cpsww com Web www CPSww com Mail 4241 12th Avenue E Suite 400 Shakopee MN 55379 Hours of Operation Monday Friday 8 00am 5 00pm CST Entire contents copyright 2008 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited Copyright 2008 CyberPower Systems Inc
5. e transfer the Product Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product 2 Product or Connected Equipment must be properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 3 Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap 4 Product and Connected Equipment must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and Connected Equipment 5 Damage from any circumstance described as excluded above with respect to the Product 6 Damage from causes other than AC Power Line Transients spikes or surges on properly installed gro
6. nterface PP75 Environmental Operating Temperature 32 F t0104 F 0 Cto40 C Operating Relative Humidity 0 to 95 Management Built in Charger Optional Safety Approvals Certifications FCC Class B certified cUL UL1778 RoHS RoHS Compliant Warranty 3 year warranty Free Tech Support Customer Service If the battery pack requests further service please refer to the following information 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated Proof of Purchase receipt or other proof of the original purchase and provide a description of the defect 4 Pack and ship the product to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and you must pay the cost of the repair estimate Copyright 2008 CyberP
7. ower Systems Inc CyberPower Reliability Quality Value Product Registration CyberPower requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www cpsww com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty and the Connected Equipment Guarantee Registration is not required for coverage but note if you do not register your purchase you will be required to provide proof of purchase Product Warranty Read the following terms and conditions carefully before using the CyberPower BP48V75ART2U the Product By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Connected Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Warranty Provider CyberPower Systems USA Inc CyberPower provides this Limited Warranty Warranty Coverage This warranty covers defects in materials and workmanship in the Product under normal use and conditions Period of Coverage Please refer to the Technical Specifications Warranty section of the User Manual for period of coverage Warranty Transfer This warranty only covers the original purchaser Coverage ends if you sell or otherwis
8. reement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you 11 The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT Product Repair Replacement CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that the Product faile
9. s 2 Expansion pieces for mounting stabilizers 2 Power cords 2 Mounting ears 1 Register card 1 User s manual Basic Operation Installation Guide The UPS is supplied with rack mounting rails mounting ears and all the hardware Follow the below steps to complete the installation Step1 Place the UPS in the Racks 1 Attach the mounting ears to each side of the UPS 2 Slide the UPS into the rack 3 Use screws to affix the mounting ears to the rack Copyright 2008 CyberPower Systems Inc CyberPower Reliability Quality Value Step2 Connect the External Battery Pack s One Battery Pack ACOUTPUT ACINPUT 0 9 0 0 0 Change Only Plug the Battery Pack into the UPS Ensure the color coded Battery Pack connector lines up correctly with the colors in the UPS socket Multiple Battery Packs l 2 i N Y SO Push To gt Be o o OUTPUT y L ANS Reser 6 60 6 6 A Ep gt al a S S o o e L z K a E Ue E NY AC OUTPUT f o o as
10. t happened if available Fine print The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CyberPower is the warrantor under this Limited Warranty Conformance Approvals FCC Notice ES This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that may cause undesired operation WARNING This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit
11. the number of battery packs connected to the UPS The UPS must be equipped with the appropriate number of external battery packs In order to recognize the battery packs there are two ways to set up the UPS Oo PowerPanel Business Edition Dress the display toggle to set up the correct battery pack numbers For battery run time table information visit www CPSww com or contact Trouble Shooting Problem Possible Cause Solution The UPS LCD does not Do not set the UPS to By pressing the display toggle to select perform expected recognize the battery functions Then set up the correct battery runtime pack s pack numbers The default setting is 0 Allow the battery pack to charge for 24 Batteries are not fully hours Do not expect full runtime during charged this initial charge period i Specified battery pack models can use AC The battery pack does to shorten charge time not work The status of circuit breaker is off Switch on the circuit breaker The fuse blew Contact CyberPower Systems Open the cover on the rear panel and replace the new fuse Copyright 2008 CyberPower Systems Inc CyberPower Reliability Quality Value Technical Specifications Model BP48V75ART2U Voltage 48V Physical Dimensions in 2U Rack 17 x19 x3 5 Weight Ibs 70 Battery ie Free Lead 12V 9 0AHX8 I
12. unded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone 6 Copyright 2008 CyberPower Systems Inc CyberPower Reliability Quality Value equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission 7 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment 8 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 9 The Product was designed to eliminate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses from lightning or other power transients If it can be shown that a voltage spike lasting longer than ims has occurred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void 10 CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited ag
Download Pdf Manuals
Related Search
Related Contents
Mode d'emploi Manual Tombacat User Manager 1.1 GFC-5 MMI 人工蘇生器用テスト肺 取扱説明書 ASUS P526 User's Manual Vonage MD6430 User's Manual Descargar GreenIQ GIQ-USWIF-001/EN Use and Care Manual Caractéristiques techniques Précautions d`emploi Description Copyright © All rights reserved.
Failed to retrieve file