Home

Perle S-1110P-M2SC05-XT

image

Contents

1. Perle10 100 1000 Ethernet Extended Temperature Media Converters Installation Guide S 1110 XT P N 5500321 10 Overview This document contains instructions necessary for the installation and operation of the Perle Standalone Extended Temperature 10 100 1000 rate converting Media Converters S 1110 XT These products have the ability to convert 10 100 1000Base T cable connections copper to 100 1000Base X connections fiber The fiber connection can be either single mode SM or multimode MM and can operate over different wavelengths and distances depending on the model selected see table below Extended Temperature Models Model Connector Mode Wavelength Xx Distance TX RX S 1110 M2xx05 XT MM SC ST 550 m 1804 850 nm S 1110 S2xx10 XT SM SC ST 10 km 6 2 mi 1310 nm S 1110 S1SC10U XT SM SC 10 km 6 2 mi 1310 1490 nm S 1110 S1SC10D XT SM SC 10 km 6 2 mi 1490 1310 nm S 1110P SFP XT SFP Note 1 Note 1 Fiber characteristics will depend on the SFP fiber module selected Please visit Perle s website for the most up to date Installation guides models and specifications http www perle com 2 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide Installation The default DIP switch settings all switches in the UP position will work for most installations These are the steps required to configure the Perle S 1110 XT Etherne
2. 1000 Ethernet Extended Temperature Media Converter Installation Guide Fiber Optic Specifications Wavelength TX Power RX Power Model Mode nm dB dB Budget S 1110 M2xx05 XT MM TX 850 Min 9 5 Min 17 75 RX 850t Max 4 Max 3 g S 1110 S2xx10 XT SM TX 1310 Min 9 5 Min 20 10 5 RX 1310 Max 3 Max 3 S 1110 S1SC10U XT SM TX 1310 Min 9 Min 20 11 RX 1490 Max 3 Max 3 S 1110 S1SC10D XT SM TX 1490 Min 9 Min 20 11 RX 1310 Max 3 Max 3 S 1110 SFP XT SFP Note 1 Note 1 Fiber characteristics will depend on the SFP fiber module selected It is recommended the SFP fiber modules used with this product are rated for ambient temperature 40T to 85 4 OF to 185F Fiber Cabling Requirements MM 50 125 microns or 62 5 125 microns SM 9 125 microns Ethernet Copper Cabling Requirements e Category 5 UTP or STP e 24 22 AWG e Straight through or Ethernet crossover Note Please refer the product page on the Perle website for the most up to date models and specifications http www perle com Perle 10 100 1000 Ethernet Extended Temperature Media Converter 15 Installation Guide Compliance Information FCC This product has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a comme
3. 7 Installation Guide Speed copper Switch 5 Switch Position Copper port Up default 100 Down 10 Note When Auto Negotiation SW1 is set to Off the media converter will use this switch setting for the copper port speed 100 When Switch 5 is in the Up position the S 1110 XT will force the speed to 100 Mbps 10 When Switch 5 is in the Down position the media converter will force the speed to 10 Mbps Auto Fiber Negotiation Switch 6 Switch Fiber Position 1000 Mbps Up default Auto Down Off Auto The Media Converter will negotiate Ethernet parameters on the fiber connection This will ensure that the most optimal connection parameters will be in effect If connecting to another Perle Media Converter this parameter should be set to Auto The Media Converter Module will advertise 1000Mbps Full and Half Duplex no Pause Off The Media Converter Module s fiber will be fixed to 1000Mbps Full Duplex When using a 100 Mbps SFP module Full Half Duplex on Fiber Switch 6 Switch Fiber Position 100 Mbps Up default Full Duplex Down Half Duplex Full Duplex The Media Converter Module will be set to Full Duplex mode on its fiber link 8 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide Half Duplex The Media Converter Module will be set to Half Duplex mode on its fiber link Loopback Fiber 1 Switch 7 Switc
4. Blinking slow Fiber link appears functional Fiber link has been brought down by Smart Link Pass Through Blinking fast Fiber link up and receiving data 12 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide SPD Copper Port Green 1000 Mbps Orange 100 Mbps Off 10 Mbps if link is currently established FDC Duplex on Copper On Full Duplex Mode Off Half Duplex Mode LKC Link Status on Copper port On Copper link is present Off No copper link present Blinking slow Copper link appears functional Copper link has been brought down by Smart Link Pass Through Blinking fast Copper link up and receiving data Troubleshooting General Te Ensure power source is connected 2 Ensure the remote device s fiber connection type is compatible with the media converter If using a simplex fiber connection ensure that you have both an Upstream U and Downstream D media converter 3 Ensure all cabling is of the correct type and is in good working order 4 For duplex fiber connections ensure the RX and TX has been reversed between the two media converters No connectivity If unable to get full connectivity with all DIP switches in the UP position this procedure is recommended for troubleshooting Perle 10 100 1000 Ethernet Extended Temperature Media Converter 13 Installation Guide Method 1 1 Set the Link Mode to Standard
5. on both media converters Leave all other switches in the Up position 2 Connect the copper device to the copper port on the media converter The LKC LED light indicates good copper connection If the LKC LED is not lit check the copper cable and the attached device 3 Repeat for the far end media converter 4 Connect the fiber cable to both media converters The LKF LED indicates good fiber connection If no LKF LED check the fiber cabling Ensure the transmitter and receiver pairs are crossed 5 Return the units to the desired configuration Connect the power source to the Media converter Method 2 The fiber connection can also be verified by configuring the remote media converter for loopback mode The LKF LEDs on both media converters should be lit Data should pass through the local converter over the fiber connection to the remote media converter At the remote media converter the data will be looped back and passed through the fiber back to the local converter and passed to the copper link Technical Specifications Power Input Consumption 6 16V DC 2 6 W at 12VDC Operating Temperature 40 to 75C 40F to 167F Storage Temperature 40 to 85 40F to 185F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Dimensions 150 mm by 95 mm by 26 mm MTBF SC ST Models 489 616hours MTBF SFP Models 584 216hours 14 Perle 10 100
6. ded Temperature models are supplied with a Pluggable Terminal Block e Unplug the terminal block from the Media Converter e Ensure the Power Source is off e Strip both wires 5mm 3 16 inch e Loosen the terminal block screws and connect Positive wire to the left terminal Connect the Negative wire to the right terminal Tighten Terminal screws 0 22Nm 0 25Nm torque e Plug the terminal block into the Media Converter e Turn on power source Check that the PWR LED light is lit e For extra power cable strain relief attach the strain clip to the case as shown below and thread the power cable through the clip in either one or two loops Perle 10 100 1000 Ethernet Extended Temperature Media Converter 11 Installation Guide Operation Status LED The Perle 10 100 1000 Rate converting Extended Temperature Media converters have status LEDs located on the front panel of the unit 1000Base X 10 100 1000Base T On Power is applied to the unit Blinking slow Loopback mode one or both fiber interfaces are in loopback mode Blinking fast Power On failure See LED Pattern to determine pattern combination and failure cause LED Pattern FDF LKF FDC Off Off On SFP incompatible Internal hardware failure All other LED patterns FDF Fiber Duplex On Full Duplex Off Half Duplex LKF Status on Fiber Link On Fiber link is present Off No fiber link present
7. ffecting the other connection Smart Link Pass Through In this mode the link state on one connection is directly reflected through the media converter to the other connection If link is lost on one of the connections then the other link will be brought down by the media converter If the installation has a media converter on both ends of the fiber link and both are set up for Smart Link Pass Through then a loss of copper link on the far end device will propagate through both media converters and will result in a loss of link at the near end device Perle 10 100 1000 Ethernet Extended Temperature Media Converter 5 Installation Guide Fiber Fault Alert Switch 3 Switch Position Fiber Port Up default Enabled Down Disabled Enabled If the media converter detects a loss of signal on the fiber receiver it will immediately disable its fiber transmitter signal on the same port This in effect notifies the fiber link partner that an error condition exists on the fiber connection If the remote media converter is set up for Fiber Fault Alert FFA and the local media converter is set up with Link Pass Through a loss of fiber link will be passed through to the local copper connection thus notifying the connected device If the media converter has been set to Smart Link Pass Through mode the effect will be the same as FFA since the link loss on the fiber receiver will result in bringing down the copper link w
8. h Position Mode Up default Disabled Down Enabled Disabled The loopback feature is disabled This is default position for normal operation The switch must be set to this position in order for data to pass through the media converter Enabled This is a test mode All data received on the receive RX fiber connection is looped back to the transmit TX fiber connection The data link will be disabled however power to the powered devices will be maintained This mode will override all other switch settings Installing the SFP Fiber Module SFP models only 1 Locate the appropriate fiber module and insert the SFP into the opening on the front of the media converter 2 Ensure the SFP module is properly seated The release latch of the SPF fiber transceiver must be in the closed up position before insertion 3 The SFP module may be inserted before or after applying power to the media converter 4 Proceed with cable connections Installing the Duplex Fiber Cable 1 Locate a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from one media converter to the other media converter switch fiber device ensuring that the RX and TX are reversed crossed at the opposite end Perle 10 100 1000 Ethernet Extended Temperature Media Converter 9 Installation Guide Perle Media Converter Perle Media RX RX Converter tx TX Installing the Simp
9. hich will in turn cause the transmit fiber link to be brought down Note This feature only takes effect if Fiber Negotiation has been turned off Disabled The media converter will not monitor for or generate Fiber Fault Alert 6 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide Illustration of the FFA The following diagram is an illustration of the operation of this feature A Remote Media Converter setup for Fiber Fault Alert Enabled Fiber Negotiation OFF and Link Mode Standard B Local Media Converter setup for Fiber Fault Alert Enabled Smart Link Pass Through On and Fiber Negotiation OFF 1 A Loses fiber connection on its receiver 2 A Sends FFA 3 B Detects FFA signal and shuts down the fiber link 4 B Drops link on copper connection because Smart Link Pass Through is configured 5 A Link on copper connection is not affected because Smart Link Mode is set to Standard Duplex copper Switch 4 Switch Position Copper port Up default Full Duplex Down Half Duplex Note When Auto Negotiation SW 1 is set to Off the media converter will use this Duplex setting for the copper port Full Duplex In the Up switch position the media converter will be set to Full Duplex mode Half Duplex The media converter will be set to Half Duplex mode Perle 10 100 1000 Ethernet Extended Temperature Media Converter
10. lex Fiber Cable 1 Locate a 1000Base X compliant simplex 1 strand fiber cable with appropriate connectors Ensure that the TX wavelength matches the RX wavelength at the other end and the RX wavelength matches the TX wavelength at the other end 2 Connect the fiber cable from one media converter to the other media converter switch fiber device Installing the Copper Cable 1 Locate 10 100 1000Base T compliant copper cables with the appropriate connectors 2 Connect the RJ 45 cable between the Perle media converter and the device Note The Perle media converter supports Auto MDIX which allows connection of a straight through or cross over Ethernet cable See Auto MDIX Jumper Settings in this guide for jumper positions Grounding the Media Converter If your installation requires additional grounding this procedure can be followed Grounding the chassis requires the following items e One grounding lug not provided e Grounding wire 12 to 18 AWG not provided e Cross head screwdriver not provided Note For your safety when installing this equipment always ensure that the chassis ground connection is installed first and disconnected last 10 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide e2 1 Strain Clip 1 Attach the grounding lug to the ground wire 2 Attach the lug to the chassis with the grounding screw s Powering up the Perle Media Converter Exten
11. ly DIP Switch Settings Auto Negotiation copper Switch 1 Switch Position Copper Up default Auto Down Off Note Auto negotiation should only be turned off if the copper link partner does not support Auto Negotiation and fixed settings are required by the copper link partner 4 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide Auto When enabled the media converter will negotiate with its link partner to determine the most optimal parameters for this connection The S 1110 XT will advertise capabilities of 10 100 and 1000 Mbps full and half duplex as well as pause and remote fault capabilities to the link partner If the copper link partner does not support Auto negotiation the S 1110 XT will parallel detect to 10 or 100 Mbps and force Half Duplex mode as per IEEE specifications Off When the Auto Negotiation switch is set to the OFF position the media converter will not negotiate the Ethernet parameters with the copper link partner The parameters used by the media converter will be determined by the Duplex switch 4 and Speed switch 5 DIP switch settings Link Mode Switch 2 Switch Position Mode Up default Standard Mode Down Smart Link Pass Through Standard Mode In this mode link on the fiber and copper sides can be brought up and down independently of each other A loss of link on either the fiber or copper port can occur without a
12. rcial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this Guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Laser Safety IEC 60825 1 2007 This product meets Class Laser safety requirements per IEC 60825 1 2007 standard and complies with FDA CDRH 21 CFR1040 10 and 21CFR1040 11 WARNING Visible and invisible laser radiation may be present when cables are not connected Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure Warranty Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage Details can be found at http www perle com support_services warranty shtml Con
13. t media converter 1 Insert SFP Module SFP Model only Set the Auto MDIX jumper setting optional Set the DIP switch settings if required Set the Powering Option Jumpers if required Install and connect the fiber cable s Install and connect the copper cable s Power up the media converter NOOR WD Auto MDIX Jumper Settings Note The factory settings for Auto MDIX will work for most installations but in the rare case that you need to modify the settings the procedure is below To access the Auto MDIX jumper settings unscrew the six side screws on the case and remove the cover plate Locate the MDIX AUTO jumper set as detailed below By covering or strapping pins 1 and 2 the S 1110 XT will operate as an MDIX device By covering or strapping pins 2 and 3 the S 1110XT will automatically detect the Ethernet cable s polarity Removing the strapping is the same as AUTO Pinl Pin2 Pin3 l Ill MDI AUTO Note The default jumper setting is AUTO Perle 10 100 1000 Ethernet Extended Temperature Media Converter 3 Installation Guide DIP Switches The DIP switches are accessible through the opening in the side of the enclosur 1 Auto Negotiation copper 2 Link Mode 3 Fiber Fault Alert 4 Duplex copper 5 Speed copper 6 Fiber Negotiation 6 Full Half Duplex Fiber 100 SFP module only F 7 Loopback 1 eueeet Mi _ 12345678 Note All switch changes take effect immediate
14. tacting Technical Support Perle Technical Assistance Center PTAC at the link www perle com support_services support request shtml Copyright 2012 Perle Systems Limited All rights reserved No part of this document may be reproduced or used in any form without written permission from Perle Systems 16 Perle 10 100 1000 Ethernet Extended Temperature Media Converter Installation Guide

Download Pdf Manuals

image

Related Search

Related Contents

低所得世帯向け支援に関わる「簡易なチューナー」の公募  Digitaler Satellitenreceiver DSL 250  THIS MANUAL SHALL BE PERMANENTLY  Digital-Lokdecoder Digital Locomotive Decoder Décodeur  Avaya BCM 5.0 - Contact Center - Intelligent Contact Center User's Manual  CDA FW850 fridge-freezer  LG 223MP67VQ-P  Whirlpool CGM2751TQ0 User's Manual  Cisco CAB-C13-ACB= power cable  