Home
Technoline WS 2350 weather station
Contents
1. fan O fan p uu DC 6 0V oto THERMO HYGRO PC COM PORT 7 ee Socket for Adaptor Socket for Sensor pccom Port 00 Battery compartment 58 Thermo Hygro Setting up using batteries Sensor sockets Battery Compartment RAIN DISPLAY a SS i Thermo Hygro Sensor Battery Cover WIND Sensor sockets Important To avoid operating problems please take note of battery polarity if inserting any batteries 1 Pull away the rain cover of the thermo hygro sensor to reveal the three sockets for the wind sensor rain sensor and the base station 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the thermo hygro sensor by clicking them into place 3 Open the battery cover of the thermo hygro sensor located below the three sockets and insert 2 x AA IEC LR6 1 5V bat teries and close the cover 59 4 Open the base station s battery cover located at the back of the unit and insert 3 x AA IEC LR6 1 5V batteries into the bat tery compartment and c
2. PRESSURE key Toggle between Absolute and Relative air pressure displays 73 DISPLAY key Toggle between the following current max imum minimum display modes Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Outdoor dew point Rainfall 24h 1h total WIND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm pro gramming mode In alarm programming mode to select the following setting modes Time alarm setting Indoor temperature alarm high amp low Outdoor temperature alarm high amp low Indoor humidity alarm high amp low Outdoor humidity alarm high amp low Outdoor wind chill alarm high amp low Outdoor dew point alarm high amp low Rainfall alarm 24h 1h Pressure alarm high amp low Wind speed alarm high amp low Wind direction alarm In setting modes confirmation of the se lected values To exit MIN MAX modes To reset general alarm symbol MIN MAX key In normal display mode to toggle between display of MIN MAX values To toggle between MIN MAX values in MIN MAX mode To exit any programming mode PLUS key In normal display mode to toggle between format of date display seconds time alarm and time zone To increase the values in the setting modes To exit MIN MAX
3. indicator on the LCD receiver Quite frequently interferences are only of a temporary nature and may be easily overcome If there are wireless headsets remote babysitters or other devices working on 433MHz in your house or in the vicinity their switch on time is mostly limited Furthermore most of these devices allow the change to an interference free frequen cy Such measures will effectively overcome interferences 20 Transmission Range The transmission distance from the thermo hygro sensor to the base station in open space under optimum conditions is 100 me ters Although the signal transmission may travel though solid surfaces or objects the following points should be avoided if possi ble High frequency interferences of any kind Constructions of any kind or trees The distance of transmitter and receiver to conducting planes or object including the human body or the ground does influ ence the transmission characteristics and thus the transmis sion distance Broadband interferences in municipal areas can reach levels reducing the signal noise ratio over the entire frequency band thus also reducing the transmission distance 90 22 Devices working close by example a neighbor s house may also influence reception Poorly shielded PCs can cause interferences that will reduce or in some cases stop reception Cleaning and Maintenance Clean the housing and screen of the base station only with a
4. as rainfall and will be received and displayed at the base station after about 2 minutes delay i e when the reading in terval is reached to clear this testing data on the base station refer to the section MIN MAX Mode below Mounting the thermo hygro Sensor f Wall Bracket Rain Cov er J Main Unit 67 An ideal mounting place for the thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws to affix the wall bracket to the desired wall plug in the thermo hygro sensor to the bracket and secure both parts by the use of the supplied screw and ensure that the cables from the wind and rain sensors are correctly plugged in otherwise data transmission errors could occur 10 Resetting amp factory settings As previously mentioned in the event of a power reset to the sen sor for example a change of batteries the base station has to synchronize to the sensor again otherwise no weather data will be received To do this simply press and hold the PLUS key for 2 seconds and a short beep will sound to synchronize the base sta tion to the sensor When the units are synchronized the data will be received again and the base station will return to normal opera tion mode Do not reset the power of the base station otherwise all 175 sets of recorded weath
5. damage to this item 18 Changing batteries Battery change only in the thermo hygro sensor 1 Open the battery cover 2 Remove the old batteries and insert with new ones of the rec ommended type and replace the cover Once the sensor is powered up press and hold the PLUS key for approx 2 seconds in the normal display mode the base station will sound a short beep and synchronize to the sensor otherwise no weather data will be received Battery change only in the base station 1 Connect power adaptor to base station and power outlet 2 Open the battery cover located at the back of the base station 3 Remove the old batteries insert with new ones of the recom mended type and replace the cover This method of battery replacement will result in no loss of MIN MAX and history data However in case of possible power failure the base station will lose the MIX MAX and all weather data recordings and will need to be synchronized to the sensors again by pressing the PLUS key for 2 seconds 88 Note When batteries require replacement for the base station the low battery indicator will light up on the LCD gs ext Please participate in the preservation of the envi ronment by properly disposing of all used up batte ries and accumulators at designated disposal points Never dispose of batteries in a fire as this may cause explosion risk of fire or leakage of dangerous chem icals and fumes 19 Interferences and p
6. mode Unit settings temperature pressure rainfall wind Air pressure offset for calculation of relative air pressure Weather picture threshold Storm warning threshold LCD contrast Alarm time Weather Alarm thresholds State of alarms enabled disabled Rainfall total value and reset time date 17 Accessories adding cable extensions For your convenience additional telephone cables to increase the connection distance between each of the units may be purchased from any reputable hardware store Simply add these to the current cables to extend your cable connection distance n HIT g Telephone Extension Cables When securing the cables during mounting ensure that base sta tion can receive the weather data since increasing the cables lengths may also increase levels of interference and result with 87 reception difficulties Interference levels will greatly depend on the surrounding area for example setting up on or near metal piping may considerably reduce reception For best results do not to add more than 10 meters of extension cable from item to item onto the existing cable lengths as this may reduce reception levels Again reception and interference levels will greatly depend on the surrounding environment at your point of mounting Note It is important to keep all the connected extension heads away from rain moisture and other extreme weather conditions as exposure can cause short circuits and
7. modes 74 In normal display mode to re enter data learning mode long pressing for 2 seconds MINUS key In normal display mode to enable disable the buzzer alarm long pressing To decrease the values in the setting modes In basic programming mode acoustic storm alarm ON OFF To turn the alarms off 24 hours when the alarm is sounding In MIN MAX modes to resets recorded values and recorded dates and times e Press any key to activate the LCD Backlight 13 Basic Programming Modes Manual Setting modes The manual setting mode allows the user to change several basic settings which is done by accessing one mode after the other simply by pressing the SET key After the final mode or if no key is pressed for 30 seconds the manual setting returns to the normal display mode The manual setting takes the user through the following modes 8 level LCD contrast setting default level 5 Manual time setting hours minutes 12 24h time display select default 24 hours Calendar setting year month date Time zone setting 12 hours default 0 Temperature display unit degree Celsius or Fahrenheit default degree Celsius Wind speed display units in m s km h mph Beaufort knots default setting km h Rainfall display in mm or inch default setting mm Air pressure display in hPa or inHg default setting hPa 0 Relative air pressure setting from 920 0 hPa 1080 0 hPa default
8. mounting bracket from the remote wind speed sen sor leaving the wire going through the bracket 2 Place two nylon straps through the slots on the mounting bracket 3 Place the remote wind speed sensor in your desired location 4 Fasten the two nylon straps securely around the mounting location 5 Slide the remote wind speed sensor onto the bracket making sure to lock it in place Once the wind sensor is fixed onto the mast connect the cable to the corresponding thermo hygro sensor socket so that operating power supply can be received and data can be transmitted to the base station 66 Mounting the Rain Sensor Funnel portion Base portion _ _ 7 For best results the rain sensor should be securely mounted onto a horizontal surface about 1 meter above the ground and in an open area away from trees or other coverings where rainfall may be reduced causing inaccurate readings When securing into place check that rain excess will not collect and store at the base of the unit but can flow out between the base and the mounting surface test by pouring clean water After mounting the rain sensor connect the cable to the thermo hygro sensor at the corresponding socket so power supply can be received and data be transmitted to the base station The rain sensor is now operable For testing purposes very slowly pour a small amount of clean water into the rain sensor funnel The water will act
9. nanana Liability disclaimer esceeceeseesseceseeceeeeeseeteaeeeeeseaeesseeeeaeessaes This Operation Manual is part of this product and should be kept in a safe place for future reference It contains important notes on setup and opera tion 51 Please visit our web site www heavyweather info for downloads of complete instruction manuals and the most current version of the Heavy Weather software 1 Introduction Thank you for purchasing this Professional Remote Weather Sta tion Designed for everyday use the weather station will prove to be an asset of great value for your personal use in the home or office Please read this instruction manual thoroughly to fully understand the features and functions so that you can enjoy the safe and cor rect operation of this unique product 2 Intended Use Weather Station The base station measures the indoor environment of its surround ing area and receives weather data from the following three outdoor sensors 1 Thermo Hygro Sensor 2 Wind Sensor 3 Rain Sensor The received data is continuously updated to bring you the latest weather information on the base station s LCD The thermo hygro sensor is the main data communication unit since both the wind and rain sensors are connected to the thermo hygro sensor for operating power and rely on it to communicate to the base station Weather data sent from the thermo hygro sensor can be done by wireless 433
10. the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Indoor humidity high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the indoor humidity high alarm set mode 3 Press and hold the SET key to enter the indoor humidity high setting values digits will start flashing and set the desired indoor humidity high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM once more to toggle to the indoor humidity low alarm set mode 5 Press and hold the SET key to enter the indoor humidity low setting values digits will start flashing and set the desired in door humidity low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Outdoor humidity high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the outdoor humidity high alarm set mode 80 3 Press and hold the SET key to enter the outdoor humidity high setting values digits will start flashing and set the desired out door humidity high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and pres
11. the MIN MAX modes If the maximum and minimum modes with times and dates are displayed press the PLUS key twice to return the normal display mode Resetting the MIN MAX records Whilst in the minimum or maximum mode the time and dates are also displayed along with the recorded values If the MINUS key is pressed whilst any of these values are displayed that particular 77 minimum or maximum record will be reset to current reading to gether with the current time and date with the exception of the fol lowing The first case is Rainfall Total which has neither maximum nor minimum records since it will show only the total rainfall Press ing the MINUS key will reset the rainfall total value to zero and the time recording to current time The second case is Rainfall 24h or 1h which records maxi mum rain count only for these respective times Pressing the MINUS key in either of these two modes will reset the rain count to the current rain count and time and date 15 Alarm Programming Modes Alarm Modes As well as the normal time alarm this feature will allow users to set a range of specific alarms to meet specific weather and tempera ture conditions set by the user The weather station allows for the following 13 alarms modes to be set Time alarm Indoor temperature high alarm and low alarm Outdoor temperature high alarm and low alarm Indoor humidity high alarm and low alarm Outdoor humidity high alarm and
12. 1013 0 hPa OF OV Ts CO N O 75 11 Weather forecast sensitivity setting 2 hPa 4 hPa default 4 hPa 12 Storm warning sensitivity setting 3 hPa 9 hPa default 5 hPa 13 Acoustic storm alarm On OFF default ON To change any of the above values once your are in the setting mode use the PLUS or MINUS keys to select the values fol lowed by the SET key to enter the next setting Continue to press the SET key to toggle through the setting mode until the LCD re turns to the normal display mode or press the MIN MAX key at any time to exit Note Keeping the PLUS or MINUS key depressed when setting certain units in the manual setting mode will increase decrease digits in greater steps Manual time setting The base station will continue to scan for the radio controlled time signal from 2am 6 am each day winter time or from 3am 6am summer time despite it being manually set During reception at tempts the DCF tower icon will flash e f reception has been unsuccessful then the DCF77 tower icon will not appear but reception will still be attempted the following hour within the time frame e If reception has been successful the received time and date will overwrite the manually set time and date and no further re ception is attempted until the following day 14 MIN MAX Programming Modes MIN MAX display Mode The MIN MAX Mode provides the user with information about the MIN MAX values of all weather d
13. 6 17 24 WIND MIN MAX N 93 LO AL maL NW f I DIR AL J j S a 18 FT F i gt q i m s knots bit km h A Ye sw gaat 26 BuzZER OFF T 27 Low battery indicator 17 Rainfall units inch or mm DCF77 radio controlled time icon 18 Temperature display units C or F Date display 19 Outdoor temperature humidity Time zone display display Date seconds alarm time and time 20 Indoor temperature humidity display zone 21 Dew point temperature display Alarm icon 22 Wind chill temperature display Weather forecast icons 23 Wind alarm icon Weather tendency indicator 24 Wind information for Min Max speed Pressure alarm display hPa inHg air pressure unit Pressure units relative or absolute 433MHz reception icon Rainfall display Indoor outdoor humidity dew point wind chill rainfall alarm icon 24h 1h or total hour display Humidity display as RH 25 26 27 63 and wind speed low high direction alarm Wind direction and speed m s knots Beaufort km h or mph dis play Alarm buzzer ON OFF icon General alarm icon 8 Function test Once the weather station is powered up perform a function test by checking that the weather data is received To do this press the either DISPLAY PRESSURE or WIND keys to toggle through the relevant LCD sections Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Dew point Rainfall 24 hour Rainfall 1hour Ra
14. MHz transmission up to 100 meters in open space or by cable connection Using the enclosed 2 meter computer cable and CD ROM you can install the Heavy Weather software to your PC and upload all the received weather data from the base station Access the latest weather information from your PC and upload up to 175 sets of recorded weather data by the base station and generate useful statistics and charts onto your spreadsheets 175 sets of data is stored in the base even if the PC is switched OFF The software 52 itself does not set any limits as to how many data sets that can be transferred to PC This weather station is designed to work easily with your PC There are no tedious requirements to turn your PC ON or OFF simply connect and disconnect the PC cable at any time System Requirements for PC use The minimum system requirement for use of this Heavy Weather software is Operating system Windows 98 or above Processor Pentium 166 MHz or above RAM 32MB of RAM or above Hard disk 20MB free space CD ROM drive 53 Features of the base station Receives and displays the DCF77 radio controlled time and date Display of extensive weather data in all cases with programmable alarm functions for certain weather conditions as well as records of all minimum and maximum values along with time and date of their recordings Indoor and outdoor temperature and relative humidity displays in degrees Fahrenheit or Celsi
15. Operation Manual Professional Remote Weather Station Table of Contents 4 Page IintrOGUCtio Mis inaia aa aaaea aaea erae eaaa EO Eaa r EAEE ETARA Intended use Weather Station srci aerias aina System requirements for PC USC ccccsseeeeteeeeteeeeeteeeees Features of the base Station ccccccceseeeeeeeeeeeeeneeeeeeeeeeeeaee Features of the thermo hygro sensor Features of the wind sensor Features of the rain sensor x E Safety NOLES sceo raare na aana ETASAN Aa EAER ENTAS Packaged Contents iicccc sesccissatccccssacisctestvavendsataccevasvastesssacseasians Setting Up eee eecceeeeeeceeeeeeeeeeeeeseaeeseeeeeeeseeeseeeseeeeeaeeeaes Operation using cable connection or wireless 433MHz EBEA vets isccressceceseseccazstetsartiens ET Function test Mounting eeceeeeeeereeeneeeeeees Resetting amp factory settings Function description Operation keyS 06 Bs Basic programming modes iv a isis MIN MAX programming modes cceeceeeceeeeeeeteeeeneeeeeeeeeeesaee Alarm programming Modes cccceceeeteeeseeeeeeeeneeeeeeeeneeeneeeetens Auto memory for stored values Accessories extensions cables ees Changing batteries eee eeeeeeeeeereeeeeeeee Interference and problems with operation Transmission range TR Cleaning and maintenance cceceeeeeseeeeneeeeeeeeneeseeeeeneeteeeeae Specifications arora eer pi seraa teen E EA
16. and hold the SET key to enter the rain setting values digits will start flashing and set the desired rain values by us ing the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to another alarm setting mode Pressure high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the pressure high alarm set mode 82 3 Press and hold the SET key to enter the pressure setting values digits will start flashing and set the desired pressure high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the pressure low alarm set mode 5 Press and hold the SET key to enter the pressure low setting values digits will start flashing and set the desired pressure low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM once more to toggle to another alarm setting mode Wind speed high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the wind speed high alarm set mode 3 Press and hold the SET key to enter the wind speed setting values digits will start flashing an
17. ata together with the time and date at which these values were recorded 76 Entering each MIN MAX mode In the normal display mode for e g the indoor temperature and humidity press MIN MAX key to toggle the display between the maximum minimum and current records While the maximum or minimum values are shown press the DISPLAY key once to show the time and date that value was received Now press the MIN MAX key to toggle from the minimum and maximum readings and the time and dates the records were received are also shown Still in the MIN MAX mode where the time and date for a value are shown press the DISPLAY key to move through each respective unit as follows Indoor temperature max or min with time and date Indoor humidity max or min with time and date Outdoor temperature max or min with time and date Outdoor humidity max or min with time and date Outdoor wind chill max or min with time and date Outdoor dew point max or min with time and date Rainfall 24 hours max or min with time and date Rainfall 1 hour max or min with time and date Rainfall total max only with time and date When in any of the above modes press the MIN MAX key to toggle between the maximum or minimum values of those records and their respective time and dates will also be shown For the wind and pressure minimum and maximum readings the same would apply except that the WIND or PRESSURE keys would be used instead of the DISPLAY KEY Exiting
18. ault values are deactivated at the start up and any alarm must be activated by the user otherwise it will not sound 69 11 Function Description of the Weather Station After setting up the following data will be displayed in different sections on the LCD If this is not the case please observe the notes on Interferences below ae gM LCD Section 1 2 44 un TH ig HH Time date seconds time zone TENDENCY weather forecasting icons with tendency arrows air pressure and respective alarms sections PRESSURE HI AL em m hPa Ls iLi i moon Teme HUMD foj LCD Section 2 Indoor and outdoor temperature m 255 SG and relative humidity wind chil dew point rainfall and respec WIND N i NW NE O tive alarms sections HIAL cT 1 i yjma1 LCD Section 3 wW LLI SE s z ed Wind direction wind speed and X J respective alarms sections N 7 sw ot tes SE s Time amp Date LCD Section 1 If the DCF77 icon icon 2 is ON and not flashing it means that the DCF77 radio controlled time and date are has been received Press the PLUS key to change the format of date display between date month year weekday date month seconds alarm set time and time zone Weather forecasting LCD Section 1 The three weather icons Sunny Cloudy and Rainy represent the weather forecasting There are also two weather tendency indica tors to show the air pressure tendency either side of the weather ico
19. contents onto a table or flat surface and check that the following are complete Item Consisting of Fittings Illustration Base e Main unit e AD DC 230V power Station Adaptor optional use included Thermo e Main unit 10 meter cable gt Hygro e Rain protection optional connection to Sensor cover the base station in cluded Wall mounting screws l Plastic anchors for screws Wind e Main unit with 1 x U bolts for mast po Sensor wind vane holder e 10 meter cable 2 x Washers T lt already at 2 x Nuts C 4 tached to the 2 x Plastic cable ties oO i main unit UO e Mast holder e L shaped extension Rain e Main unit base Sensor and funnel e 10 meter cable already at tached to the main unit Heavy CD Rom format e 2 meter PC cable for weather English PC connection op PC German and tional use included software French languages only 57 5 Setting up Firstly choose to use the adaptor included in this set or batteries for operation Both these methods allow for operation of using wireless 433MHz transmission or cable connection between the base station and the sensors and setting up for both methods is as follows Base Station 000 3 O
20. d by checking the set alarm values against the MIN MAX values reached To deactivate the general weather alarm icon press the ALARM key Important When entering the alarm set mode for a specific weather or tem perature condition the corresponding alarm is automatically enabled ON when the SET key is pressed regardless of its pre vious setting and the alarm value will flash to indicate that it has been activated Press the ALARM key to confirm the setting and continue pressing the ALARM key to toggle through each alarm mode until it returns to the normal display mode or press the MIN MAX key at any time to exit the alarm setting modes When a set weather alarm condition has been activated that par ticular alarm will sound and flash for approximately 2 minutes but will continue to flash until weather conditions have become more steady Weather Alarms The weather alarms are settable for when certain weather condi tions are met according to the users requirements For example the user can set the thresholds for the outdoor temperature to 40 high and 10 low whilste only enabling the high alarm and disabling the low alarm i e temperatures lt 10 won t trigger alarm but temperatures gt 40 will 85 Alarm setting Minimum Maximum Storm threshold 3 hPa 9 hPa Air Pressure 920 0 hPa 1080 0 hPa Outdoor Tempera 30 00 69 9 ture Indoor Temperature 9 9 No alarm will 59 90 sound if the minimu
21. d set the desired wind speed high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the wind speed low alarm set mode 5 Press and hold the SET key to enter the wind speed low setting values digits will start flashing and set the desired pressure low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Wind direction alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the wind di rection alarm set mode 3 Press and hold the SET key to enter the wind direction setting values 83 4 Using the PLUS or MINUS keys select the desired wind direction and use the SET key to confirm or cancel each direc tion input 5 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Storm warning alarm setting Unlike the other weather alarms the storm warning alarm is set by entering the main manual setting mode as follows 1 Press the SET key to enter the manual setting mode 2 Continue to press the SET key until the Storm warning icon flashes tendency arrow flashing downwards with the pressure value
22. e relative air pressure is also the one value given by various newspapers TV and radio broadcasting stations in their daily weather forecasts for their respective locations users can set the relative air pressure of the weather station to this value 71 to represent readings your their area see Basic Programming Modes below Weather Data LCD Section 2 Indoor temperature and humidity are displayed simultaneously in this section Use the DISPLAY key to toggle through the displays for other weather information Outdoor temperature humidity Outdoor wind chill Outdoor dew point Rainfall 24h Rainfall 1h Rainfall total Notes to Dewpoint and Windchill Air can at a certain temperature only carry a certain amount of water water vapor which also increases and decreases with tem perature If the air temperature decreases below the so called dew point saturation point the excessive water vapor will condense and fall out in form of dew fog or rain At a temperature of e g 15 and a relative humidity of 50 the dewpoint wi Il be about 5T at 80 humidity about 12 At a relative humidity of 100 satura tion is reached i e the dewpoint is 15 At a dew point below freezing the fallout will become frost or snow Windchill has been introduced for battle planning during World War Il It represents not the real measured but the one temperature a person feels in open area under the influence of wind and cold Windc
23. er history data for transferring to the PC will be lost for full details of PC use please see PC user manual in the en closed Heavy Weather CD ROM However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and hold the PRESSURE and WIND keys for about 5 seconds The base station will beep once and the entire LCD will light up for 5 seconds and go back to the original factory settings This process with clear all previous user defined values and all weather history recordings 68 Factory default settings The following table shows the factory default values of the weather station Matter Default Setting Time 0 00 Date 01 01 2001 Time zone 0 Alarm time 0 00 Relative air pressure 1013 0 hPa Weather picture threshold 3 hPa LCD contrast level 5 1 8 levels Rainfall per impulse 0 518mm Storm alarm 5 hPa Relative air pressure alarm 960 0 hPa low 1040 0 hPa high Indoor temperature alarm 10 0 C low 30 0 C high Outdoor temperature alarm 0 0 C low 40 0 C high Indoor humidity alarm 35 RH low 65 RH high Outdoor humidity alarm 45 RH low 70 RH high Wind chill alarm 10 0 C low 30 0 C high Dew point alarm 0 0 C low 30 0 C high Rainfall 24h alarm 50 0mm Rainfall 1h alarm 1 0mm Wind Speed 1km h low 100km h high Wind direction alarm None set Note All alarm def
24. ey is pressed 60 6 Operation using cable connection or wireless 433MHz Cable Connection Using this method of operation will provide interference free trans fer of the weather data from the sensors to the base station The data sending interval from the sensors to the base station will also be more frequent compared to using 483MHz transmission and will result in higher power consumption Therefore batteries will have a shorter life span for cable connection compared to using 433MHz To operate using cable connection simply use the enclosed 10 meter cable and connect the thermo hygro sensor to the base sta tion Once the connection is detected the base station will automat ically continue reading the data from the sensor The user may at any time switch from cable connection to using 433MHz or vice versa by simply disconnecting or connecting the cable from the base station to the sensor When the base station detects no cable connection to the sensors the existing data read ing interval is changed to the new reading interval i e using cable connection is every 8 seconds data reading interval or from 32 seconds 128 seconds intervals when using 433MHz depending on wind speed Using the AC adaptor to operate the base station will also supply power to the sensor if the cable is connected to it Batteries used for 433MHz transmission may be left in the sensor when using cable connection for power back up in case of AC power fai
25. hill is laid out in tables for various temperatures and wind speeds At an outdoor temperature of e g 8C and calm winds a person moving at a speed of 6 m s will already feel a windchill tem perature of OT Wind Data LCD Section 3 The current wind direction will be displayed on the LCD compass on the wind section Press the WIND key to toggle between wind direction as numerical e g 2259 and abbreviated characters e g 72 SW as well as numerical wind speed display inside the compass circle 12 Operation keys The base station has 8 keys for easy operation Please refer to the following table for use and function of each key Further descrip tions of the key functions with regard to their immediate range of application can be found in the Programming modes SET key In normal mode to enter the manual basic programming mode In basic programming mode to select the following setting modes LCD contrast setting Manual time setting hours minutes 12 24 time format display Calendar setting year month date Time zone setting f temperature setting Wind speed unit setting Rainfall unit setting Pressure unit setting Relative air pressure setting Weather picture threshold setting Storm warning setting Acoustic storm alarm setting In setting modes confirmation of the se lected values In alarm modes alarm ON OFF In alarm mode to enter programming of alarm values long pressing To exit MIN MAX modes
26. infall Total Relative and absolute pressure Wind speed wind direction and wind direction in degrees CONDIRE If any readings cannot be received from the sensors lines will be displayed in the respective weather sections of the LCD In this case check that all cables are correctly inserted into the correct sockets and press and hold the PLUS key for 2 seconds and a short beep will sound to synchronize the base station to the sen sors otherwise no weather data will be received Some weather readings such as wind speed and direction may not appear immediately on the LCD if the wind fan or vane of the wind sensor is moved This is due to the set reading time intervals for the wind readings However the current wind speed or direction will be displayed once the time reading interval is reached For rainfall the interval readings may take up to 2 minutes before the data is displayed on the LCD 9 Mounting Important Note Prior to drilling mounting holes and permanently affixing any of the units please ensure the following points are considered e Cable lengths of the units meet with your distance require ments at the point of fixing 64 e Signals from the sensors can be received by the base station at points of mounting e Radio controlled time signal can be received at the point of mounting Base Station With two foldable legs at the back of the unit the base station can be placed onto any flat surface or wall mou
27. lose the battery cover Setting up using the AC adaptor 1 Power up all the sensors as described in setting up using bat teries above 2 Using the AC adaptor included plug it into the mains outlet and power up the base station by inserting the adaptor jack in to the 6 0V DC socket located on the side of the base station Every time the thermo hygro sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronized with the base station to receive weather data When the base station is powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code After the learning mode or by pressing the MIN MAX key at any time the base station will start the DCF77 radio controlled time reception Note for DCF77 Radio Controlled Time The time and date display is based on the signal provided by a highly accurate Caesium atomic clock operated by the Physikalisch Technische Bundesamt in Braunschweig Germany This radio controlled clock does not only provide for the weather station s time and date display but also functions as the time source for all of this weather station s memory and history values using time and date information LCD backlight When using the power adaptor or under battery operation the LCD backlight will switch on for 15 seconds when any k
28. low alarm Wind chill high alarm and low alarm Dew point alarm high alarm and low alarm Rainfall 24h alarm Rainfall 1h alarm 10 Pressure high alarm and low alarm 11 Wind speed high alarm and low alarm 12 Wind direction alarm 13 Storm warning alarm OONAARWN Setting Alarms For alarm setting press the ALARM key once whilst in normal op eration mode to enter the normal alarm time and by further pressing the ALARM key will toggle through each of the alarm modes 78 Note The alarm icon will automatically appear upon pressing the SET key to tell the user the alarm is activated Further pressing the SET key will deactivate reactivate the alarm Time alarm setting 1 2 3 4 Press the ALARM key to enter the normal time alarm Press and hold the SET key to enter the alarm hour time set mode the hour digits will flash and set the desired hour by us ing the PLUS or MINUS keys Press the SET key to enter the alarm minute time set mode the minutes digits will flash and set the desired minutes using the PLUS or MINUS keys Press ALARM key to confirm followed by the MIN MAX key to return to the normal display mode Indoor temperature high alarm and low alarm setting 1 2 3 Press the ALARM key to enter the normal time alarm Press the ALARM key again to enter indoor temperature high alarm set mode Press and hold the SET key to enter the indoor temperature high setting values digits will sta
29. lure A loss of power would desynchronize the base station and the sensor and no weather data will be received To Synchronize the units so that the weather data can be received press and hold the PLUS for 2 seconds However in general batteries that will not be used for long periods should be removed to avoid leakage Wireless 433MHz transmission Using 433MHz wireless transmission of weather data from the sensor to the base station will provide users greater freedom as to where units can be positioned without the need to be restricted by cable 61 Note If no outdoor weather data is displayed or the signal to the sensors is lost during setting up mounting changing of batteries to the sensor or plugging or unplugging cables simply press and hold the PLUS key for 2 seconds and a short beep will sound to syn chronize the base station to sensors Without being synchronized weather data will not be received 62 7 LCD Overview The following illustration shows the full segments of the LCD for description purposes only and will not appear like ae during normal operation and use 4 Time DST TENDENCY 1 rel abs 19 21 DATE ALARM ZONE G8 88 wn 888888 I l l Mia AA a PRESSURE LOALHIAL MINMAX 88688 20 MNDOOR OUTDOOR TEMP amp noa 3 4 DEW POINT CHILL RAIN 24htht0TAL HE 6 E 8 Ss 4 9 a inHg 19 22 15 1
30. m indoor temperature alarm is set below 9 9 C Humidity all 1 RH 99 RH Rainfall 24h 0 0 mm 1000 mm Rainfall 1h 0 0mm 1000 mm Wind 0 0 m s 50 0 m s Hysteresis To compensate for fluctuation of the measured data which may cause the weather alarm to sound constantly if the measured read ing is close to user set level a hysteresis function has been imple mented for each weather alarm For example if the high tempera ture alarm is set to 25 and the current value mo ves to 25 the alarm will be activated if it has been enabled Now when the temperature drops to 24 9 or below and thereafte r again in creases to beyond 25 C the data will be blinking but no alarm will be activated It has to drop to below 24 with a pre set hystere sis of 1 so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table Weather data Hysteresis Temperature 16 Humidity 3 RH Air pressure 1 hPa Rainfall 24h 5 0mm Rainfall 1h 0 5mm Wind 10 km h 86 16 Auto memory for stored values The base station has a memory back up system which is used to memorize user defined settings for when the batteries are changed or if a power failure occurs User defined units are automatically updated each time these are changed The base station will me morize the following user defined units Time zone 12 24h time display
31. nd regional authorities to retrieve the addresses of legal dumping grounds with selective collec tion All electronic instruments must from now on be recycled User shall take an active part in the reuse recycling and recovery of the electrical and electronic waste The unrestricted disposal of electronic waste may do harm on public health and the quality of environment This product must however not be thrown in general rubbish collection points 93 As stated on the gift box and labeled on the product reading the User manual is highly recommended for the benefit of the user The manufacturer and supplier cannot accept any responsibili ty for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for pub lic information This product is only designed to be used in the home as indica tion of the future weather and is not 100 accurate Weather forecasts given by this product should be taken only as an in dication and not as being totally accurate The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written con sent of the manufacturer R amp TTE Directive 1999 5 EC Summary of the Declaration of Conformity We hereby declare that this wireless transmission device does comply with the essential re
32. ng Range Air Pressure Resolution Alarm duration 92 0 to 180 km h or 0 to 50 m s 0 1m s Graphic Resolution 22 5 Degrees Numerical Resolution Letter format 32 sec if wind fac tor gt 10m s or 128sec if wind factor lt 10m s 10 mi nutes if the base station fails to receive any data af ter 5 attempts in a row all outdoor data readings will display except for the rain value 8 seconds 4 times per minute 9 9T to 59 9T shows OFL if outside range 0 1T 1 to 99 1 3 times per minute 300 hPa to 1099 hPa Standard air pressure at an altitude of 9 100 me ters is around 300 hPa 0 1 hPa 2 minutes approx Power consumption Base Siation Batteries or AC power Thermo hygro sensor Battery life using 433MHz Battery life using cable connection Dimensions L x W x H Base Station Thermo hygro sensor Rain sensor Wind sensor 3 x AA IEC LR6 1 5V Alkaline recommended INPUT 230V C 50HZ use the provided AC DC adap ter only 2 x AA IEC LR6 1 5V approximately 12 months alkaline batteries recommended approximately 6 months alkaline batteries recommended 170 x 32 x 139 mm 71 5 x 73 x 136 mm 140 x 70 x 137 mm 250 x 277 6 x 77 9 mm Liability disclaimer The electrical and electronic wastes contain hazardous sub stances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local or a
33. ns 70 lama yi 625 ood Sunny Cloudy Rainy Notes to hPa sensitivity setting for weather forecasting The hPa Hekto Pascal pressure sensitivity can be set to suit the user s requirement for weather forecasting from 2 hPa to 4 hPa see Basic Programming below For areas that experience fre quent changes in air pressure which does not necessarily reflect a change in the weather requires a higher hPa setting compared to an area where the air pressure is stagnant For example if 3 hPa is selected then there must be a fall or rise in air pressure of at least 3 hPa before the weather station will register this as a change in weather Air Pressure LCD Section 1 The air pressure reading is displayed here Press the PRESSURE key to toggle between relative and absolute air pressure displays Notes to Absolute and Relative Air Pressure Absolute air pressure provides the display of the true measured air pressure of the current time and location This is not programmable and the absolute air pressure range of the weather station is from 300 hPa to 1099 hPa standard air pressure at an altitude of 9 100 meters is around 300 hPa Relative air pressure is the one value that is calculated back to sea level from the local absolute air pressure and can thus be taken as a reference for weather condition and weather development for the entire country It can be programmed to represent your local sur roundings Since th
34. nted at the desired loca tion by the hanging holes also at the back of the unit It is important to check that the 433MHz if using wireless connection and the DCF77 radio controlled time signal can be received before perma nently mounting any of the units Should the base station not dis play the 433MHz weather data from the sensors or the radio con trolled time from the desired location then relocate the units Once the signals are received the system can be affixed Also if you have selected to use cable connection ensure that distances can reach all desired locations before affixing any unit permanently Mounting the Wind Sensor The remote wind speed sensor can be mounted two ways With the use of screws Using nylon straps Mounting with screws Wind vane Fixed with screw Horizontal panel 65 1 Unlock the mounting bracket from the remote wind speed sen sor leaving the wire going through the bracket 2 Place the mounting bracket over the desired location 3 Through the two screw holes of the bracket mark the mounting surface with a pencil 4 Screw the mounting bracket onto the mounting surface En sure that the screws are tight against the bracket 5 Slide the remote wind speed sensor onto the bracket making sure to lock it in place MOUNTING WITH NYLON STRAPS Vertical mast Wind fan T Fixed with Nylon strap 1 Unlock the
35. ormal time alarm 2 Continue to press the ALARM key until you reach the dew point high alarm set mode 3 Press and hold the SET key to enter the dew point setting val ues digits will start flashing and set the desired dew point high by using the PLUS or MINUS keys 81 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the dew point low alarm set mode 5 Press and hold the SET key to enter the dew point low setting values digits will start flashing and set the desired dew point low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Rainfall 24h alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the rain 24 hour alarm set mode 3 Press and hold the SET key to enter the rain setting values digits will start flashing and set the desired rain values by us ing the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to another alarm setting mode Rainfall 1h alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the rain 1 hour alarm set mode 3 Press
36. quirements of R amp TTE Directive 1999 5 EC 94
37. r cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to ther mo hygro sensor which in turn transmits the data to the base sta tion Operating power is taken from the thermo hygro sensor by a 10 meter cable connection 3 Safety Notes e Damage caused by failure to comply with this instruction manual will invalidate any guarantee The manufacturer and supplier will not be held liable for actions due to failure to comply with this in struction manual or from data inaccuracies that may occur with this product e In case of harm or damage to a person or property caused by improper handling or failure to comply with this instruction manual the manufacturer and supplier cannot be held liable e For reasons of safety and operation alterations to this device are strictly prohibited 55 To operate the weather station use only supplied adaptor and batteries of the recommended type Do not leave used up batteries in the device as these may corrode and release chemicals that may damage the unit Inserting batteries in an incorrect polarity will cause damage to this product This product is not a toy kept out of the reach of children Do not depose new or used batteries to fire as they may explosion or release dangerous chemicals This product is not to be used for medical purposes or for public information 56 4 Packaged Contents Before setting up carefully unpack the
38. roblems with operation Problem amp cause Remedy Distance between transmitters and re ceiver too long Reduce distance between transmitters and receiver to receive signal High shielding mate rials between the units thick walls steel con crete isolating alumi num foil and etc Find a different location for sensors and or receiver See also Item Transmission Range below Interference from other sources e g wireless radio headset speak er etc operating on the same frequency Find a different location for the sen sors and or base station Neighbors using electrical devices operating on the 433MHz signal frequency can also cause interference with reception No Reception after adding extension cables Find a new location for the sensors and or base station Recommend not adding more than 10 meter extension cables between units to the existing cable lengths as this will increase the chance data reception problems 89 Reception then no Press and hold the PLUS key for 2 reception loss of seconds to synchronize the base transmission signal station to the sensors for weather data from the sensor to the reception If still no signal then base station change the sensor batteries and syn chronize the units again Poor contrast LCD or Check the LCD contrast setting or no reception or low change batteries check low battery batteries in sensors or
39. rt flashing and set the desired indoor temperature high by using the PLUS or MINUS keys Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM once more to toggle to the indoor temperature low alarm set mode Press and hold the SET key to enter the indoor temperature low setting values temperature digits will start flashing and set the desired indoor temperature low by using the PLUS or MI NUS keys Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Outdoor temperature high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 79 2 Continue to press the ALARM key until you reach the outdoor temperature high alarm set mode 3 Press and hold the SET key to enter the outdoor temperature high setting values temperature digits will start flashing and set the desired outdoor temperature high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM once more to toggle to the outdoor temperature low alarm set mode 5 Press and hold the SET key to enter the outdoor temperature low setting values digits will start flashing and set the desired outdoor temperature low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press
40. s flashing 3 Set the desired hPa pressure value 3 hPa 9 hPa using the PLUS or MINUS keys 4 Press the MIN MAX key to confirm and return to the normal display Storm warning alarm ON OFF After storm warning alarm setting the next mode to appear after pressing the SET key is the storm warning ON OFF Use the PLUS or MINUS key to change the status to AON or AOFF Default setting is ON Should the air pressure drop equal or below the pre set hPa value within the last 6 hour period then the downward tendency arrow will flash as an indication of possible storm The base station will take hourly measurements as a point of reference The storm warning indicator will stop flashing once the air pressure becomes more stable Master Alarm BUZZER OFF The time and all the weather alarms may have buzzer sound set to OFF by holding the MINUS key down for about 3 seconds in normal display mode and the BUZZER OFF icon appears on the bottom left of the LCD When the BUZZER OFF is displayed the time and all other weather alarms when activated will only flash but 84 not sound regardless if that particular alarm has been set to the ON To deactivate the BUZZER OFF press the MINUS key once more General Alarm Icon The general alarm icon on the bottom right corner of the LCD will appear when any weather alarm is activated to show the user that a set weather condition has been reached The activated alarm can be determine
41. s the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the outdoor humidity low alarm set mode 5 Press and hold the SET key to enter the outdoor humidity low setting values digits will start flashing and set the desired out door humidity low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to the to enter another alarm setting mode Wind chill high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the wind chill high alarm set mode 3 Press and hold the SET key to enter the wind chill high setting values digits will start flashing and set the desired wind chill high by using the PLUS or MINUS keys 4 Press ALARM key to confirm and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the wind chill low alarm set mode 5 Press and hold the SET key to enter the wind chill low setting values digits will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode Dew point alarm high alarm and low alarm setting 1 Press the ALARM key to enter the n
42. soft damp cloth Do not use abrasives or solvents Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for blockages every now and then Also clean the seesaw of the sensor with a damp cloth and check by lightly tapping with your finger that it can move freely from side to side Do not clean the funnel with the bottom half of the rain sensor attached nor the bottom part itself under running water This may bear the danger of water entering the unit s inner parts and cause damages Do not immerse the base station in water Should there be damage to this product please do not at tempt to make any repairs Please take this unit to a qualified technician Opening or improper handling of the units will inva lidate any guarantee Specifications Outdoor data Transmission Distance in Open Field 100 meters max Temperature Range 29 9T to 69 9 show OFL if outside range Resolution 0 10 Measuring Range Rel Humidity 1 to 99 Rain Volume Display 0 to 999 9mm 1h and 24h rainfall 0 to 2499 9mm Total rainfall Resolution 0 1mm 91 Wind Speed Resolution Wind Direction 433MHz data transmission Measuring interval thermo hygro sensor With wire data transmission Measuring interval thermo hygro sensor Indoor data Pressure temperature Indoor Temperature Range Resolution Measuring Range Rel Humidity Resolution Relative humidity checking interval Measuri
43. us user selectable Indoor and outdoor relative humidity displays Air pressure reading in inHg or hPa absolute or relative user selectable Detailed display of rainfall data in 1 hour 24 hours total since last reset user selectable in mm or inch Wind speed in mph km h m s knots or Beaufort user selectable Wind direction display with LCD compass as well as numerical e g 2259 and abbreviated characters e g SW Wind chill temperature display Dew point temperature display Weather forecast display by weather icons sunny cloudy rainy Weather tendency indicator Storm warning alarm LED back light 54 e Simultaneous display of all weather data with individual settings by the user e COM port for easy connection to your PC e All the weather data from the base station and up to 175 sets of weather history data with user adjustable measuring intervals can be recorded and uploaded to your PC Features of the Thermo Hygro Sensor The thermo hygro sensor measures the outdoor temperature and relative humidity It also collects the readings from the rain and wind sensors before transmitting the data to the base station by wireless 433MHz or by the 10 meter cable included in this set Features of Wind sensor The wind sensor measures wind speed and wind direction and sends the data to thermo hygro sensor which in turn transmits the data to the base station Operating power is taken from the ther mo hygro sensor using a 10 mete
Download Pdf Manuals
Related Search
Related Contents
Germanium 500 取り扱い説明書 Rencontres Philosophiques de Langre - Cinéma New Vox PDFBedienungsanleitung SF(H)22-A P1 (DE), 882.8 kB The PDF document below provides a user manual for Chesney`s Manual APD-AR-14-039 39 CUTMASTER™ Service Manual Copyright © All rights reserved.
Failed to retrieve file