Home
Chief K1D100 flat panel desk mount
Contents
1. 12 Figure 11 Adjustments Head Tilt Adjustment 1 Adjust head tilt to desired tilt position See Figure 12 2 Adjust head tilt tension screw to change the adjustment tension See Figure 12 Height Adjustment CAUTION OVERTENSIONING THE HEIGHT ADJUSTMENT TENSION SCREW MAY CAUSE DAMAGE Do NOT overtighten height adjustment tension screw when adjusting tension for lighter or heavier displays 1 Adjust arm height to desired level See Figure 12 2 Open cable management cover on upper arm to expose height adjustment tension screw See Cable Management section for details 3 Use 1 8 hex key J to adjust height adjustment tension screw to change adjustment tension See Figure 12 NOTE Turn clockwise to reduce tension for lighter displays and counter clockwise to increase tension for heavier displays 4 Close cable management cover on upper arm See Cable Management section for details Pivot Adjustment 1 Adjust pivot position as desired See Figure 12 2 Use 3 16 hex key H to adjust pivot point tension screws to change pivot adjustment tension See Figure 12 Reduce tension lighter display Qi Increase tension SJ heavier display Do NOT overtension adjustment tension screw head tilt tension pivot point tension Figure 12 Installation Instructions K1 Series Pivot Adjustment Range Single Arm Models K1D100 K1C100 K1W100 and K1P100 1 Adjus
2. DOWN 75 CH MANUAL HEIGHT ADJUSTMENT RANGE 273 1 1075 CABLE MANAGEMENT COVER 13 LIFT ARM HEIGHT ADJUSIMENT TOTALHEIGHT ADJUSIMENT 9 11 231 4 ANI o MAX HEIGHT 32 86 834 6 U CABLE MANAGEMEN KEIER HEIGHT ADJUSTMENT KNOB DESKTO P THICKNESS RANG E 12 7 50 MAX 3 25 82 6 K1 Series Installation Instructions DIMENSIONS CONTINUED K1P100 POLE CLAMP RANGE 1 50 1 90 38 1 50 8 2 297 MAX 19 12 QUICK RELEASE ne VESA INTERFACE a gol 75 90 INTERFACE 02 95 ROTATION GH MANGEMENT E COVER PITCH TENSON ADJ USIMENT e o 13 606 50 HEIGHTADJ USTMENT CABLE MANGEMENT COVER a 2 50 E E DE ei MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 2 172 MAX 19 00 03 937 02 953 90 INTERFACE ROTATION QUICK RELEASE SE Ae VESA INTERFACE 75 R N CABLE MANAGEMENT COVER 13 LIFT ARM HEIG HT ADJ USMENT 519 4 MAX 20 45 nye TH 176 517 6 95 CABLE MANAGEMENT COVER a N d Installation Instructions K1 Series LEGEND Tighten Fastener
3. Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com l pis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand A mano Von Hand Com a m o A mano Met de hand la main Optional Opcional Optional Opcional Opzionale Optie En option e d y V 2 Hex Head Wrench Llave de cabeza hexagona
4. MANAGEMENT COVER l 1 SCH K1 200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 H 03 937 02 953 EXTENSION ETNE MIN 2 09 53 2 MAX 19 9 505 ROTATION QUICK RELEASE le VESA INTERFACE 75 5 q CABLE MANAG EMENT COVER Installation Instructions K1 Series K1C100 DIMENSIONS CONTINUED 188 1 741 8 85 224 7 FOR LOWER PROFILE INSTALL LOWER PRO FILE INSTALL EXTENSION 100 MIN 2 13 54 0 LOWER PROFILE INSTALL MAX 21 7 551 2 90 INTERFACE Ri QUICK RELEASE ROTATION VESA INTERFACE CABLE MANAG EMENT PITCH RANGE COVER 10 DOWN 13 LIFTARM HEIGHT 75 UP PITCH TENSION ADJ USTMENT s ga ADJ USIMENT Lis TOTAL HEIGHT ADJ USTMENT MN HEIGHT MANUAL HEIGHT 9 11 231 4 ADJUSTMENT RANGE LOWER MAX HEIGHT 273 1 PROFILE 32 86 834 6 10 75 INSTALL CABLE MANAGEMENT COVER A D eeh 1 bei HEIGHT ADJUSIMENT KNOB DESKTOP THICKNESS RANGE q 127 j 50 z MAX 3 25 82 6 bel Leg 88 1 3 00 1 50 K1C200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 36 5 927 1 90 INTERFACE ROTATION EXTENSION QUICK RELEASE MIN 2 13 54 0 VESA INTERFACE MAX 19 5 495 3 PITCH RANGE 10
5. allow for full arm articulation WARNING Only remove display from mount when the 4 Close cable management covers on monitor arm See display can be lifted up from the mount DO NOT remove Figure 18 display unless the display is in the upright position See 5 Repeat Steps 1 4 for lower arm Display Removal section for details Cable Management 1 Use screwdriver to unhinge tab on either end of cable management cover on upper arm See Figure 17 2 Slide screwdriver along edge of cover until remaining tabs are unhinged and cover is in the open position See Figure 17 cable management cover Figure 17 14 Installation Instructions K1 Series Display Removal WARNING Only remove display from mount when the display can be lifted up from the mount DO NOT remove display unless the display is in the upright position See Figure 19 1 Make sure display is in the upright position 2 Remove quick release faceplate from mount by pressing quick release tab and sliding faceplate off mount See Figure 19 quick release tab Figure 19 15 K1 Series Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8800 002059 Rev05 2012 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 08 12 USA International Europe Asia Pacific p TI U gt TI U gt TI U 6436 Ci
6. INSTALLATION INSTRUCTIONS K1C100 Height adjustable Monitor Arm Series i CHIEF K1 Series Our Mounts Your Vision K1 Series Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of fac
7. all at desired mounting location See Figure 6 4 Use two 1 4 2 1 2 hex head lag screws F and two 1 4 washers G to install wall bracket onto wall See Figure 6 IMPORTANT Overtightening screws F may cause bracket to compress into soft wall surface resulting in difficult mount installation or improper engaging of set screw in Step 6 5 Hang monitor arm A over wall bracket See Figure 6 6 Secure monitor arm to wall bracket by tightening set screw Ensure set screw engages back side of wall bracket E to properly secure mount See Figure 6 O set screw side view o CE F x2 10 Figure 6 Installation Instructions K1 Series Connecting K1P Series to Pole 1 Determine approximate location for mount keeping in mind display size extension height adjustment requirements 2 Place mount A against pole with clamp H on opposite side of pole See Figure 7 K1P assembly Figure 7 3 Using 5 32 hex key L and appropriate length screws loosely attach K1P assembly to pole clamp H If installing to 1 1 2 NPT pipe use 1 4 20 x 1 1 2 button head cap screws J If installing to 1 1 2 diameter pipe use 1 4 20 x 1 button head cap screws K See Figure 7 4 Position mount at desired height and orientation 5 Equally tighten screws against mount and the pole clamp Display Installation 1 Remove quick release face
8. l Sechskantschl ssel Chave de cabeca sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale s GI YD Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit K1 Series Installation Instructions TOOLS REQUIRED FOR INSTALLATION e 12 345 3 16 included t 1 8 included 5 32 included with K1P Series only PARTS monitor arm K1D100 shown x 8 screws and spacers B 4 or 8 C 4 or 8 D 4 or 8 included with dual arm mounts M4x14mm M4x25mm M10x5 3x10 N included with K1W Series wall mount only S F 2 1 4 x 2 1 2 1 4 J 4 K 4 1 4 20 x 1 1 2 1 4 20 x 1 1 g lamp L 1 1 pole c 5 32 M 1 N 1 3 16 1 8 Installation Instructions K1 Series Assembly And Installation Connecting K1C Series column mount to Desk Standard Installation 1 Loosen clamp screw until enough space is created between clamp and mount to allow for desk mounting See Figure 1 NOTE If space is limited behind desk i e against wall etc remove clamp screw and attachment entirely and reattach clamp screw prior to Step 3 See Figure 2 2 Place mount on top of desk at desired mounting location See Figure 1 3 Tighten clamp using clamp scre
9. ons K1 Series DIMENSIONS K1D100 MIN 2 09 53 14 MAX 19 9 505 5 90 INTERFACE ROTATION PIICHRANGE QUICK RELEASE 10 DOWN VESA INTERFACE 75 UP PICH TENSION ADJUSIMENT d HEIGHT ADJUSTMENT 14 7036 5 373 4 165 10 CABLE MANAGEMENT COVER L2 D H DESKTOP THICKNESS RANGE 5 19 05 ae MAX 2 50 63 5 R 8 118 3 K1D200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 EXTENSON MIN 2 09 53 2 MAX 19 9 505 90 INTERFACE ROTATION QUICK RELEASE 10 DOWN VESA INTERFACE 75 UP CABLE MANAGEMENT COVER CABLE MANAGEMENT COVER DESKTOP THICKNESS RANG E 19 1 75 MIN 2 50 MAX 63 5 4 65 K1 Series Installation Instructions DIMENSIONS CONTINUED K1W100 13 LIFT ARM HEIGHT ADJUSIMENT CABLE MANAGEMENT COVER QUIC K RELEASE 100 VESA INTERFACE D 3 94 EXTENSION MIN 2 09 53 2 90 INTERFACE 75 MAX 19 9 505 ROTATION 92 PITCH RANGE ABLE 10 DOWN MANAGEMENT dee VER PITCH TENSION ADJ USTMENT GHT ADJUSIMENT 39 399 165 1 15 CABLE 15 71365
10. plate from mount by pressing quick release tab and sliding faceplate off mount See Figure 8 1 Gan release tab Figure 8 WARNING Only remove display from mount when the display can be lifted up from the mount DO NOT remove display unless the display is in the upright position See Display Removal section for details Carefully place display face down on protective surface Connect faceplate to display For flush mounting hole installation Using Phillips screwdriver carefully install four M4x14mm screws B through corresponding holes on faceplate and into the mounting holes on the display See Figure 9 for flush mounting holes d quick release faceplate II Figure 9 For recessed mounting hole installation Place four spacers D on top of mounting holes on back of display See Figure 10 Using Phillips screwdriver carefully install four M4x25mm screws C through corresponding holes on faceplate spacers D and into the mounting mounting holes on the display See Figure 10 11 K1 Series Installation Instructions quick release faceplate for recessed mounting holes TRR OO Y co 4 Position display with faceplate attached above mount See Figure 11 5 Slide faceplate onto mounting head until quick release tab Figure 10 clicks into place See Figure 11
11. t arm angle as desired up to 90 degrees in either direction See Figure 13 top view edge of desk or wall face WARNING Swinging the arm beyond 90 degrees may result in the mount slipping off the desk causing serious injury i edge of desk or wall face top view 90 degrees range i perpendicular centerline Figure 14 Column Height Adjustment K1C Series only 1 Loosen column adjustment knob See Figure 15 2 Adjust height to desired level See Figure 15 3 Tighten column adjustment knob See Figure 15 90 degrees range of motion Figure 13 Dual Arm Models K1D200 K1C200 K1W200 AND K1P200 Figure 15 1 Adjust arm angles as desired within a 90 degree range from the edge of desk or wall and a perpendicular centerline of mount See Figure 14 WARNING Swinging the arm beyond this range may result in the mount slipping of the desk causing serious injury 13 K1 Series Installation Instructions Portrait Adjustment 1 The monitor may be adjusted 90 degrees in either direction in order to provide a portrait view of the monitor See Figure 16 Figure 18 3 Route cables through cable management channels See Figure 18 IMPORTANT Be sure to leave enough slack in the Figure 16 cables near display and arm joint to
12. tory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located between the K1 Series Monitor Arm up to and including the display does not exceed 25 Ibs 11 34 kg per arm Use with products heavier than the maximum weight indicated may result in collapse of the mount and its accessories causing possible injury WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors SAVE THESE INSTRUCTIONS Installation Instructi
13. ty West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 SCH K d D O S consumer
14. w until mount is securely fastened to desk See Figure 1 Figure 1 Figure 2 Low Profile Installation K1C Series Only 1 Remove top cap from column See Figure 3 2 Slide mount assembly off of column See Figure 3 Figure 3 3 Rotate mount in 90 degrees in either direction prior to reinstalling onto column See Figure 4 4 Reinstall onto column and adjust to desired height See Figure 4 5 Reinstall top cap to column See Figure 4 Figure 4 6 Proceed with standard installation to desk as shown in Standard Installation section K1 Series Installation Instructions Connecting K1D Series desk mount to Desk 1 Loosen clamp screw until enough space is created between clamp and mount to allow for desk mounting See Figure 5 NOTE If space is limited behind desk i e against wall etc remove clamp entirely in Step 1 and reattach clamp prior to Step 3 Place mount on top of desk at desired mounting location See Figure 5 Tighten clamp using clamp screw until mount is securely fastened to desk See Figure 5 desk 1 Figure 5 Connecting K1W Series wall mount to Wall 1 Determine mounting location on wall 2 Use a stud finder to locate 2 x 4 wood stud 3 Use wall bracket to mark and drill two 3 16 x 2 1 2 holes in w
Download Pdf Manuals