Home

AMX NXD-435

image

Contents

1. af EFA For more detailed installation configuration programming file transfer and operating instructions refer to the NXD 430 435 Operation Reference Guide available online at www amx com Touch screen Capacitive Touch Buttons FIG 1 NXD 435 4 3 Modero Wall Flush Mount Touch Panel Black Overview The NXD 435 Modero Wall Flush Mount Touch Panel includes a mini USB port for programming and five NetLinx programmable buttons All power is supplied via Power Over Ethernet PoE utilizing a PS POE AF PoE Injector FG423 80 or equivalent PoE device The NXD 435 comes in black FG2262 03 and white FG2262 04 Specifications NXD 435 FG2262 03 04 Specifications Dimensions HWD NXD 435 4 13 x 5 5 x 2 13 10 48 cm x 13 97 cm x 5 40 cm e CB TP5 Rough In Wallbox optional 4 27 x 5 14 x 3 40 10 86 cm x 13 06 cm x 8 64 cm Power e PoE Powered No local Power Supply needed Requirements e Max power draw 5 5W Memory Factory e 128 MB SDRAM default e 256 MB integrated Flash Memory not upgradeable factory programmed e FCC Part 15 Class B e CE e IEC 60950 e RoHS Certifications Panel LCD e Aspect ratio 16 x 9 e Minimum brightness luminance 280 cd m2 e Channel transparency 8 bit Alpha blending e Contrast ratio 250 1 e Display colors 256 thousand colors 18 bit color depth e Dot pixel pitch 0 14 mm e Panel type WQVGA e Screen resolution 480 x 272 pixels HV 60
2. a margin for error if the opening needs to be expanded Too little wall material removed is always better than too much 3 Remove the faceplate from the NXD 435 4 Disconnect the capacitive touch connector from the 10 pin plug on the faceplate 5 Insert both connectors into their corresponding locations along the left side of the NXD 435 touch panel For full warranty information refer to the AMX Instruction Manual s associated with your Product s 11 11 6 Test the incoming wiring by attaching the panel connections to their terminal locations and applying power via the PoE Injector Verify that the panel is receiving power and functioning properly to prevent repetition of the installation 7 Thread the incoming Ethernet and mini USB wiring if mini USB access is desired from their terminal locations through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 8 Push the back box into the wall opening Insure that the locking tabs lie flush against the back box 9 Extend the locking tabs on the sides of the back box by tightening the screws inside the box until snug Not all of the tabs must be extended to lock the back box in place but extending a minimum of the top and bottom tabs is highly recommended Apply enough pressure to the screw head to keep the box flush with the wall this ensures that the locking tabs will tighten up against the inside of the wall The back b
3. front of the device in the center of the bezel and two smaller buttons on each side This button has several uses e Press the button once to start a previously programmed function or to turn off the display if not previously programmed e Press and hold the button for 6 seconds to put the device into Setup Mode e Press and hold the button for 9 seconds to enter Calibration Mode e Press and hold the button for 20 seconds to reboot the panel The NXD 435 also has four smaller buttons two on either side of the front button that may be programmed for individual functions All five buttons on the NXD 435 utilize capacitive touch which detects the electrical conductivity of human skin and reacts directly to touch This allows the button to resist wear and dirt as the button does not have any actual physical button to depress NXD 435 Setup and System Connection 1 Carefully remove the panel from the shipping box peel the protective plastic cover from the LCD and apply power to the panel via the PoE Injector 2 From below the LCD press the front button for 9 seconds passing over the Setup page to access the Calibration setup page and follow the on screen instructions to return to the main Setup page 3 Press the on screen Protected Setup button on the Setup page Enter the panel password into the on screen keypad default is 1988 5 Press the Device Number field to open the on screen Device Number keypad and enter a value for the
4. panel default is 32001 6 Press the System Settings button to open the System Settings page 7 On the IP tab toggle the DHCP Static field to DHCP if it is not already set to DHCP 8 On the Master tab toggle the Type field to Ethernet e Toggle the Mode field to URL e Enter both the System Number and Master IP Address Enter a valid Username and Password if the target Master is secured 10 Press the Back button and then press the on screen Reboot button to save any changes and cycle power to the panel Installation of the NXD 435 While the NXD 485 is designed to fit into pre existing NXD CV5 touch panel sites the actual installation differs from that of the NXD CV5 in several significant ways The NXD 435 can be installed either directly into the optional CB TP5I Rough In Box or another solid surface environment using either solid surface screws or the included locking tabs for different mounting options For more information please refer to the NXD 430 435 Operation Reference Guide available at www amx com The NXD 435 is contained within a clear outer housing known as the back box FIG 3 This back box is not removed when installing the device into a wall or into a Rough In Box Locking tab screws Locking tabs Closed Locking tabs Open FIG 3 NXD 435 backbox with closed and open locking tabs Installing the NXD 435 into a wall The NXD 435 comes with a clear plastic backbox FIG 7 designed to attach th
5. terminal sources through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 6 Connect the Ethernet and USB connectors to their corresponding locations along the left side of the un powered NXD 435 touch panel The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the necessary connectors before being inserted into the solid surface 7 Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD 435 lie flush against the wall 8 Insert and secure three 4 Mounting Screws not included into the corresponding holes located along the sides of the NXD 435 using a grounded Phillips head screwdriver until the unit is secure and flush against the wall 9 Reconnect the capacitive touch connector to the 10 pin plug on the faceplate 10 Place the faceplate back onto the device 11 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master 93 2262 03 REV D 2011 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com Pa R ve
6. Hz frame frequency e Viewing dimensions 2 3 16 x 3 13 16 5 56 cm x 9 68 cm e 2 1 8 x 3 3 4 5 40 cm x 9 53 cm Viewing Angles e Left Right Up Down 80 80 60 80 Front Panel e Center Button Capacitive touch button provides both access to Components the Setup and Calibration pages and toggles the panel between a sleep or wake state This button is also user programmable e Capacitive Touch Buttons four user programmable buttons two on either side of the Center Button Parameters Installation Guide NXD 435 4 3 Modero Wall Flush Mount Touch Panel NXD 435 Specifications Cont Side Panel Connectors e Ethernet 10 100 Port RJ 45 port for 10 100 Mbps communication The Ethernet port automatically negotiates the connection speed 10 Mbps or 100 Mbps and whether to use half duplex or full duplex mode Power is supplied through Power Over Internet PoE NXD 435 panels communicate with the NetLinx Master using the ICSP protocol over Ethernet LEDs show communication activity connections speeds and mode information L A link activity Yellow LED lights On when the Ethernet cables are connected and terminated correctly and then blinks when receiving Ethernet data packets SPD speed Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps e Mini USB Connector 5 pin Mini USB connector used for programming firmware update and touch panel file transfer betwee
7. e panel to most standard wall materials This backbox has a locking tab on three of the four faces missing only on the face containing the space for the connections to help lock the backbox to the wall These locking tabs are only extended AFTER the backbox is inserted into the wall WARNING When installing the backbox make sure that the assembly is in the correct position and in the correct place Once the locking tabs are extended and locked into place removing the backbox may be difficult without having access to the back of the wall or causing damage to the wall Note In order to guarantee a stable installation of the NXD 435 the thickness of the wall material must be a minimum of 50 inches 1 27cm and a maximum of 875 inches 2 22cm WARNING The maximum recommended torque to screw in the locking tabs on the plastic back box is 5 IN LB 56 N CM Applying excessive torque while tightening the tab screws such as with powered screwdrivers can strip out the locking tabs or damage the plastic back box 1 Prepare the area by removing any screws or nails from the drywall before beginning the cutout process 2 Cut out the surface for the back box Refer to the dimensions in the NXD 430 435 Operation Reference Guide available from www amx com for more information CAUTION Making sure that the actual cutout opening be slightly smaller than the provided dimensions is highly recommended This action provides the installer with
8. n the PC and the target panel e Operating Temperature 0 C 82 F to 40 C 104 F e Operating Humidity 5 85 relative humidity non condensing e Storage Temperature 20 C 4 F to 60 C 140 F e Storage Humidity 5 85 RH Included e NXD 435 Installation Guide 93 2262 03 Accessories Other AMX e CB TP5i Rough In Wallbox FG038 11 Equipment e Back Cover for the CB TP5i Rough In Wallbox FG038 12 e PS POE AF PoE Injector FG423 80 e NXA BEZP 435 BL Black Portrait Bezel Kit for the NXD 435 FG2262 12 e NXA BEZP 435 WH White Portrait Bezel Kit for the NXD 435 FG2262 13 e CC USB Type A to Mini B 5 wire programming cable FG10 5965 e NXA RK5 Rack Mount Kit for 5 Wall Mount panels FG2904 55 5 Rackmount Four Screws 10 32 x 625 PH Truss BLK Four Washers 10 Black Nylon Three Screws 4 40 x 250 PPH BLK Operating Storage Environments Panel Connectors and Wiring FIG 2 shows the connectors located on the NXD 435 Modero panel The mini USB port is used for programming the touch panel Ethernet 10 100 port Mini USB port Back box __ FIG 2 Connector layout on the NXD 435 Modero Wall Flush Touch Panel For more information on connection and use of the Panel Connectors as well as information on programming please refer to the NXD 430 435 Operation Reference Guide available at www amx com Capacitive Touch Buttons The NXD 435 has one main button on the
9. ox is clear to allow visual confirmation that the tabs have been extended and are gripping the wall as well as in assisting with removal if necessary NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the attached connectors before being inserted into the drywall 10 Reconnect the capacitive touch connector to the 10 pin plug on the faceplate 11 Place the faceplate back onto the device 12 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master Installing the NXD 435 into a Flat Surface using 4 screws Three 4 mounting screws not included are secured through circular holes located at the left and right sides of the NXD 435 The most important thing to remember when mounting the NXD 435 is that the outer frame Mounting Tabs must be installed flush against the mounting surface e Refer to SP 2261 02 for detailed installation dimensions e Cutting out the surface slightly smaller than what is outlined in the installation drawings in order to make any necessary cutout adjustments is highly recommended 1 Prepare the area by removing any screws or nails from the surface before beginning the cutout process 2 Cut out the surface for the NXD 435 3 Remove the faceplate from the NXD 435 4 Disconnect the capacitive touch connector from the 10 pin plug on the faceplate 5 Thread the incoming Ethernet and USB wiring from their