        CyberPower ENVIROSENSOR
         Contents
1. CyberPower    Reliability  Quality  Value        Environment Sensor    ENVIROSENSOR  User s Manual    K01 0000207 00    Overview    The CyberPower environmental sensor  ENVIROSENSOR   along with select SNMP HTTP cards  RMCARDXXxX  or most  Switched and Monitored PDUs enables users to monitor the  temperature and humidity of a server closet and or datacenter  remotely  With CyberPower s PowerPanel Business Edition  software  users can establish thresholds that will automatically  notify users when an event has occurred via email  SMS and  SNMP traps  Additionally  the ENVIROSENSOR provides 4 input  dry contacts that enable users to monitor the status of connected  devices  such as door switch sensors     Features include   e Real time environment monitoring  e Remote management and configuration of the sensor via Web  Browsers or NMS  e Automatic events notification via email  SMS and SNMP traps  e 4 input dry contacts application interface provided  e Displays the name and location of the sensor and  connected devices          Product Features    A  LED  B  Input Dry Contact 1 4  C  Common Connection  D  RJ45 Port   connect to RMCARD PDU           NOTE  Please refer to Appendix  for Input Dry Contact Application                                         Copyright    2011 CyberPower Systems  Inc     Package Contents    Hook and Loop Tape       ENVIROSENSOR User   s Manual       OP CL    CAT5 RJ45 Ethernet Cable   10 feet 3 05 m     Flat Head Screw  M3x20   with Plastic Nylon Anc
2. UIPMENT  SUCH  MODIFICATIONS COULD VOID THE USER   S AUTHORITY TO  OPERATE THE EQUIPMENT     CyberPower    yer Quality  Value     CyberPower North America   CyberPower Systems  USA   Inc    Phone   952  403 9500 Toll free   877 297 6937   4241 12th Avenue E  Suite 400  Shakopee  MN 55379  E mail  tech cpsww com   Website  www CPSww com    CyebrPower Europe  CyberPower Systems  Inc   E mail  sales cpsww eu  Website  www cpsww eu       CyberPower Systems France   Z    Saint S  verin 28220 CLOYES sur le Loir     France  T  l   33 0 2 37 98 61 50   E mail  sales cpsww com fr    Copyright    2011 CyberPower Systems  Inc     
3. hor    Technical Specification  ENVIROSENSOR       Input Voltage 7V   28V       Halt mode 72 mW   Normal mode 110 mW   Default 12V input     Power Dissipation       Measurement Range and Accuracy       32 158  F with accuracy   1 8  F     Temperature 0 70  C with accuracy   1  C       Humidity 10 90 RH with accuracy   2        Communication       Connection Port RJ45 Port       Input Dry Contact 4       Physical       2 32 x 1 77 x 1 14 inches     Dimensions  L x W x H  59 x 45 X 29 mm       Weight 1 46 oz  41 5g       Safety Approvals FCC Class B  CE  C Tick       Warranty 3 Year Limited       Installation Guide    Method 1  Hook and Loop Tape  Mounting    Step 1  Clean the surface of the  area where the sensor will  be installed  Apply one side  of the hook and loop tape  to the bottom of the sensor  and the other side to the  sensor location        Step 2  Attach the sensor on the  surface and hold for about 5  seconds to ensure cohesion     NOTE  Once the sensor is installed   you will want to leave it in place to  ensure the the hook and loop tape  maintains its adhesiveness           Step 3  To connect the sensor with  RMCARD PDU  use the  attached RJ45 Ethernet  Cable  Plug one end into the  RJ45 Port and the other end  into the RMCARD PDU     NOTE  If the distance of  RMCARD PDU and the sensor is  longer than 10 feet 3 05 m  use a  standard RJ45 Ethernet Cable as  needed  max 50 feet 15 m                              Method 2  Fixed Mounting    Step 1     Step 2     S
4. ning    This equipment has been tested and found to comply with the  limits for a Class B digital device  pursuant to part 15 of the FCC  Rules  These limits are designed to provide reasonable  protection against harmful interference in a residential  installation  This equipment generates  uses and can radiate  radio frequency energy and  if not installed and used in  accordance with the instructions  may cause harmful interference  to radio communications  However  there is no guarantee that  interference will not occur in a particular installation  If this  equipment does not cause harmful interference to radio or  television reception  which can be determined by turning the  equipment off and on  the user is encouraged to try to correct the  interference by one or more of the following measures       Reorient or relocate the receiving antenna     Increase the separation between the equipment and receiver     Connect the equipment into an outlet on a circuit different from  that to which the receiver is connected     Consult the dealer or an experienced radio TV technician  for help     This device compiles with Part 15 of the FCC Rules  Operation is  subject to the following two conditions   1  this device may not  cause harmful interference  and  2  this device must accept any  interference received  including interference that may cause  undesired operation     NOTE  THE MANUFACTURER IS NOT RESPONSIBLE FOR  ANY RADIO OR TV INTERFERENCE CAUSED BY  UNAUTHORIZED TO THIS EQ
5. tep 3        Step 4     Drill a hole that is  compatible with the  anchor and insert the  included anchor     Insert and tighten the  screw into the anchor   Leave enough of the  screw exposed for the    sensor to be mounted to     Hang the sensor  horizontally or vertically     a    To connect the sensor                   Hole 6mm 0 24in  aj       with RMCARD PDU  use the    attached RJ45 Ethernet Cable   Plug one end into the RJ45  Port and the other end into  the RMCARD PDU     For further configuration    information  please refer to the  RMCARD PDU user   s manual     Troubleshooting    Problem                   Solution                The RMCARD PDU  is not able to acquire  environment sensor s  information     Check the LED     When the connection is ok  the LED  should always be on  otherwise   ensure the RJ45 Ethernet cable is    correctly connected to the    RMCARD PDU and sensor     Note  Do not use a crossover cable    which is for Tx Rx        The Input Dry  Contact does not  function correctly        Appendix    Input Dry Contact Application  Do not input signals that carry    voltage into the input dry    Ensure the Input Dry Contact wires  are correctly connected and make  sure the open short circuit setting of  the connected devices is the same  as the setting on the Web Interface     Dry Contact                   contacts  The input dry contacts    only allow for open short circuit     alana    External Sensor 1 2 3 4    COM    Conformance Approvals  FCC War
    