Home
AMX FG2105-04 peripheral controller
Contents
1. NI 2100 NetLinx Integrated Controller NI 2100 Specifications Cont Rear Panel Components RS 232 422 485 Ports 1 3 3 RS 232 422 485 control ports using DB9 male connectors with XON XOFF transmit on transmit off CTS RTS clear to send ready to send and 300 115 200 baud ICSNet 2 RJ 45 connectors for CSNet interface provided by optional ICSNet daughter card ICSHub Out RJ 45 connector provides data to a Hub connected to the Controller provided by optional CSNet daughter card Relay Port 4 e 4 channel single pole single throw relay ports e Each relay is independently controlled e Supports up to 4 independent external relay devices e Channel range 1 4 e Each relay can switch up to 24 VDC or 28 VAC 1A e 8 pin 3 5 mm mini Phoenix female connector provides relay termination Digital I O Port 9 4 channel binary I O port for contact closure with each input being capable of voltage sensing Input format is software selectable with interactive power sensing for IR ports Note The I Os on this card are not dry closure they are electronic switches that float at 5V when Off Therefore they should not be expected to work in situations that require true dry contact or dry closure The I Os do work with AMX PC1 PC2 UPC20 and UPC20 IR Serial Ports 5 8 4 IR Serial control ports support high frequency carriers of up to 1 142 MHz with each output being capable of two electri
2. C 122 F Operating Humidity 20 to 85 RH Heat Dissipation Typical 28 7 BTU hr 2 pin 3 5 mm mini Phoenix female PWR connector 41 5025 4 pin 3 5 mm mini Phoenix female AXlink connector 41 5047 6 pin 3 5 mm mini Phoenix female I O connector 41 5063 8 pin 3 5 mm mini Phoenix female Relay connector 41 5083 Installation Kit KA2105 01 8 pin Relay Common Strip 4 rack mount screws 4 washers 2 CC NIRC NetLinx IR Emitter Cables FG10 000 11 2 removable rack ears 62 2105 07 Included Accessories Other AMX Equipment 2 pin 3 5 mm mini Phoenix male connector 41 5026 CC COM Programming Port Cable FG10 727 CC NSER IR Serial cable FG10 007 10 ICSNet daughter card FG2105 10 NCK NetLinx Connector Kit FG2902 STS Serial To Screw Terminal FG959 Upgrade Compact Flash factory programmed with firmware NXA CF2NI4G 4 GB Flash Upgrade FG2116 07 Connections and Wiring Wiring a Power Connection Use a 12 VDC compliant power supply to provide power to the Controller via the rear 2 pin 3 5 mm mini Phoenix connector The incoming PWR and GND cable from the PSN power supply must be connected to their corresponding locations within the PWR connector e This unit should only have one source of incoming power e Using more than one source of power to the Controller can result in damage to the internal components and a possible burn out e Apply power to the unit only after installation is complete RS 23
3. Fak The NI 2100 ICS is ideal for control and automation of medium sized rooms and multi room applications The NI 2100 has 64MB of onboard RAM and is Device Discovery enabled to simplify programming by standardizing device and function definitions default touch panel button assignments and control and feedback methods OUTPUT LED RS 232 422 485 Status LEDs INPUT LED RELAY Status LEDs STATUS LED IR SERIAL Status LEDs O Status LEDs LINK ACT o RELA NETLINX NI 2100 front ICSNet ICSHub Ports provided by optional ICSNet daughter card NETLINX NI 2100 rear RS 232 422 485 Ports 1 3 a al PORT 3 PORT si i PORTI z ICSNet ICSNet 1 RS 232 422 485 e BABABABA 449216 Relays Port 4 ID Pushbutton I O Port 9 ETHERNET IR Serial Ports 5 8 10 100 Port PROGRAM Port AxLink Port CONFIGURATION DIP Switch 12 VDC PWR Connector FIG 1 Ni 2100 ATTENTION Verify you are using the latest NI firmware for the on board Master Verify you are using the latest version of NetLinx Studio available for download from www amx com Specifications NI 2100 Specifications e NI 2100 Controller FG2105 04 The NI 2100 can be upgraded to provide one ICSHub and two ICSNet ports by installing the optional ICSNet daughter card FG2105 10 see Other AMX Equipment e NI 2100 ICS Controller with ICSNet FG2105 14 e 3 1 2 x 17 x 3 1 2 8 8 cm x 43 2 cm x 8 8 cm e RU 2 700 mA 12 VDC e 64
4. a series of web pages that are collectively called the Master Configuration Manager Refer to the NI Series NetLinx Integrated Controllers WebConsole amp Programming Guide for details on the WebConsole Accessing the WebConsole From any PC that has access to the LAN that the target Master resides on 1 Open a web browser and type the IP Address of the target Master in the Address Bar 2 Press Enter to access WebConsole for that Master The initial view is the WebControl page Additional Documentation Additional Documentation for the N1 2100 is available at www amx com e Refer to the NX x100 Series Hardware Reference Guide for additional details on Installation Upgrading and Wiring the NI 2100 e Refer to the NI Series NetLinx Integrated Controllers WebConsole amp Programming Guide for detailed configuration instructions 93 2105 14 REV H Aa Lr
5. 2 422 485 Wiring Connector Information FIG 2 shows the pinout and wiring specification information for the RS 232 422 485 DB9 Device Ports These ports support most standard serial mouse control devices and RS 232 communication protocols for PC data transmission The NI 2100 uses Ports 1 3 DB9 Serial Port pinouts male connector 9 RS 232 RS 422 RS 485 8 Pin 2 RX signal Pin 1 RX Pin 1 A strap to 9 Pin 3 TX signal Pin 4 TX Pin 4 B strap to 6 7 PIN 5 GND PIN 5 GND PIN 5 GND 6 Pin 7 RTS Pin 6 RX Pin 6 B strap to 4 Pin 8 CTS Pin 9 TX Pin 9 A strap to 1 FIG 2 RS 232 422 485 DB9 male connector pinouts WARNING When wiring the 422 485 connections do NOT use pre made 9 wire cable or connect the wire in the cable to any connection that will not be used by the DB9 serial port Only use wiring that connects the needed pins Ethernet 10 100 Base T Connector The RJ 45 Ethernet connector provides 10 100 network connectivity between the panel and the NetLinx Master FIG 3 ETHERNET 10 100 L A Link Activity LED lights vYA SPD green when the Ethernet o cables are connected and terminated correctly FIG 3 Layout of Ethernet LEDs SPD Speed LED lights yellow when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps Use a standard CAT5 Ethernet cable to provide communication between the Integrated Controller and external NetLinx devices Baud Rate Sett
6. MB SDRAM e 1MB Non volatile NV SRAM Models Available Dimensions HWD Power Requirement Memory Compact Flash 2GB or greater upgradeable to 4GB see Other AMX Equipment Note AMX may increase Flash size at any time in response to market availability Front Panel LEDs LINK ACT Blinks when the Ethernet cables are connected and terminated green correctly Also blinks when receiving Ethernet data packets Status green Blinks to indicate that the system is programmed and communicating properly Output red Blinks when the Controller transmits data sets channels On and Off sends data strings etc Input yellow Blinks when the Controller receives data from button pushes strings commands channel levels etc RS 232 422 485 3 sets of LEDs light to indicate that DB9 Ports 1 3 are transmitting red yellow or receiving RS 232 422 or 485 data red TX yellow RX Relay red 4 LEDs light to indicate the relay channels 1 4 are active closed These LEDs reflect the state of the relay on Port 4 IR Serial red 4 LEDs light to indicate the IR Serial channels 1 4 are transmitting control data on Ports 5 8 LED indicator for each IR port remains lit for the length of time that IR Serial data is being generated Lights when the I O channels 1 4 are active The LED for each I O port reflects the state of that particular port Weight Enclosure I O yellow Installation Guide
7. cal formats IR or Serial e 4 IR Serial data signals can be generated simultaneously e IR ports support data mode at limited baud rates and wiring distances Program Port RS 232 DB9 connector male can be connected to a DBY port ona PC This connector can be used with serial and NetLinx program ming commands as well as other DB9 capable devices to both upload download information from the NetLinx Studio program Configuration DIP Sets the communication parameters for the Program port see Baud Switch Rate Settings ID Pushbutton Sets the NetLinx ID Device only assignment for the device Ethernet Port RJ 45 connector provides TCP IP communication This is an Auto MDI MDI X enabled port which allows you to use either straight through or crossover Ethernet cables The Ethernet Port LEDs show communication activity connection status speeds and mode information e SPD speed Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps e L A link activity Green LED lights On when the Ethernet cables are connected and terminated correctly and blinks when receiving Ethernet data packets AxLink Port 4 pin 3 5 mm mini Phoenix male connector that provides data and power to external control devices Green AXlink LED indicates the state of the AXlink port 2 pin 3 5 mm mini Phoenix male connector Operating Environment Operating Temperature 0 C 32 F to 50
8. ication Settings dialog box 4 Click the Communications Settings button to open the Communications Settings dialog 5 Click the NetLinx Master radio button from the Platform Selection section to indicate you are working with a NetLinx Master 6 Click the Serial radio button from the Transport Connection Option section to indicate you are connecting to the Master via a COM port 7 Click the Edit Settings button on the Communications Settings dialog to open the Serial Settings dialog and set the COM port parameters used to communicate to the NetLinx Master 8 Click OK to close all dialogs and return to the main application 9 Right click the Online Tree tab entry and select Refresh System the Controller should appear in the Device Tree If not verify that the Serial cable is connected properly and that the Baud Rate settings on the Controller set via the Program Port DIP Switch match the settings in NetLinx Studio Once Serial communication has been established use NetLinx Studio to configure the Controller for Ethernet Communication as described below Configuring the NI 2100 for Ethernet Communication Before continuing complete the COM port steps above 1 Use an Ethernet cable to connect the Controller to the LAN to which the PC running NetLinx Studio is connected Note The NI x100 Controllers feature an Auto MDI MDI X Ethernet port This provides the option of using either a standard straight through or a cros
9. ings Program Port DIP Switch The Program Port DIP switch is located on the rear of the device Use this DIP switch to set the baud rate for the Program Port according to the settings shown in the following table Make sure the baud rate you set matches the baud rate on your PC s NetLinx COM Settings before programming the unit Baud Rate Settings Note DIP switch 1 activates deactivates the Program Run Disable Mode DIP Switches 2 3 and 4 must remain OFF at all times Ethernet Ports Used by the NI 2100 Ethernet Ports Used pare For full warranty information refer to the AMX Instruction Manual s associated with your Product s 9 10 2010 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 e www amx com Preparing the NI 2100 for Serial Communication To establish serial communication with the Controller via the PROGRAM DB3 port 1 Use a Serial DB9 cable i e CC COM Programming Port Cable not included to con nect the Controller s Program port to a DB9 port on a PC 2 Launch NetLinx Studio 2 x default location is Start gt Programs gt AMX Control Disc gt NetLinx Studio 2 gt NetLinx Studio 2 3 Select Settings gt Master Communication Settings from the menu bar to open the Master Commun
10. sover Ethernet cable to communicate with a PC both cable types will work 2 Select Diagnostics gt Network Address from the menu bar and enter the System Device 0 for a Master and Host Name information 3 To configure the Address e Use a DHCP Address by selecting the Use DHCP radio button then click the GET IP button to obtain a DHCP Address from the DHCP Server click the SET IP Information button to retain the new address and then finish the process by clicking the Reboot Master gt OK buttons e Use a Static IP Address by selecting the Specify IP Address radio button enter the IP parameters into the available fields then click the SET IP Information button to retain the pre reserved IP Address to the Master and then click the Reboot Master gt OK buttons to finish the process 4 Repeat steps 1 5 from the previous section but rather than selecting the Serial option choose TCP IP and edit the settings to match the IP Address you are using Static or IP 5 Click on the Authentication Required radio box if the Master is secured and press the User Name and Password button to enter a valid username and password being used by the secured Master 6 Click the OK to close all dialogs and return to the main application Onboard WebConsole NetLinx Masters have a built in WebConsole that allows you to make various configuration settings via a web browser on any PC that has access to the Master The WebConsole consists of