Omnitron iConverter GX/F

image

Contents

1. Page 14 on Port 1 This facilitates the connection to devices that do not auto negotiate properly on their Gigabit fiber port Note In order for Gigabit fiber ports to link up the linking two devices ports must be set to the same mode either Manual or Auto Negotiate When the P1 1000FX Fiber is set to Auto Negotiation Mode the device receiving the fault acts as if it is in RFD mode NOTE In older versions of firmware RFD was not defined on ports set to Auto Negotiation Port 2 100Fx Full Half Duplex P2 FD HD DIP Switch The P2 Full Half Duplex DIP Switch selects the duplex mode for the 100Mbps FX P2 port When set to Full Duplex FD left factory setting the P2 port operates in Full Duplex mode When set to Half Duplex HD position right P2 operates in Half Duplex mode NOTE Port 2 100FX is not defined for Auto Negotiate mode per the IEEE802 3 and is always in Manual mode UNUSED DIP SWITCHES The following DIP Switches are present on the GX F but are unused and do not affect any functionality 4 P2 AN MAN 6 P2 100 10 7 P2 1000 10 100 8 P2 AX MANX Page 11 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This pro
2. 50 125um multimode fiber up to 550m Refer to the fiber cable manufacturer for multimode distance specifications Port 2 100Fx Single Fiber Fiber Type Distance Wavelength SM 20km Tx 1310nm Rx 1550nm SM 40km Tx 1310nm Rx 1550nm SM 20km Tx 1550nm Rx 1310nm SM 40km Tx 1550nm Rx 1310nm SM 20km Tx 1310nm Rx 1550nm SM 40km Tx 1310nm Rx 1550nm SM 20km Tx 1550nm Rx 1310nm SM 40km Tx 1310nm Rx 1550nm Please contact Omnitron for other configurations 100Fx Page 4 LS 1000F LS 100Fx Connector Type P1 P2 8562 05 8562 06 2862 07 Fiber gt o Fiber rio Fiber gt o a P Pt Pi P2 oO Oo oO Switch 1 Converter A Converter B Switch 2 LS LS gt PRL gt O b P2 P1 PI P2 oO Oje oO Switch 1 Converter A Converter B Switch 2 LP LP gt PRL PSL c P2 Pt Pi P2 Oja Oj ft Of Switch 1 Converter A Converter B Switch 2 LP RFD LS gt 24 gt d P2 P1 P1 IP2 sx KA o Switch 1 Converter A Converter B Switch 2 LP RFD LP gt aS Pl e P2 Pt P1 P2 Wi eit oO Switch 1 Converter A Converter B Switch 2 SFD SFD gt Oy igs Ppa f P2 Bi Pt P2 sai oO a Switch 1 Converter A Converter B Switch 2 LED Lit LED Blinking YWR LED Off O LED Status depends on connected device LED Status Blinking off depends
3. Link signal NOTE Connecting two converters both set to RFD is not supported and will cause a deadly embrace lockup refer to the Port 1 1000FX Auto Negotiation DIP Switch section Symmetrical Fault Detection SFD mode operates similarly to the Remote Fault Detection RFD mode In SFD mode the loss of a received Link at P1 is Looped Back to P1 and propagated to P2 causing both to stop transmitting the Link signal Fig 2 f and also causing blinking in a connected GX F P1 Link LED indicator Connecting two converters which are both set to SFD is permitted and facilitates a dual loop back feature where P1 fiber faults can be reported to both ends of the network NOTE Converters in SFD mode must be deployed in pairs and the LS DIP Switch position must also be selected Page 7 iConverter GX F Dual Single Fiber Converters Port 1 1000x Dual Fiber Fiber Type Distance Wavelength MM 220m 550m 850nm MM 220m 550m 850nm MM 220m 550m 850nm MM 220m 550m 850nm SM 12km 1310nm SM 12km 1310nm SM 12km 1310nm SM 12km 1310nm For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models When using single fiber SF media converter models the Tx wavelength on one end has to match the Rx wavelength on the other 162 5 125um 100 140um multimode fiber up to 220m
4. Switch When the BPAEN DIP Switch is in the ON right position the A Ethernet backplane port is enabled This port allows connectivity to an adjacent module When the BPAEN DIP Switch is in the Off position left factory setting the A port is isolated from the backplane Backplane B Enable BPBEN DIP Switch When the Backplane B Enable BPBEN DIP Switch is in the ON right position the B Ethernet backplane portis enabled This port allows connectivity to an adjacent module When the BPBEN DIP Switch is in the Off position left factory setting the B port is isolated from the backplane Port 1 1000FX Auto Negotiation P1 AN MAN DIP Switch When set to the Auto Negotiate AN factory setting this DIP Switch enables the Gigabit Fiber Port to sense its duplex mode automatically If the connected device cannot provide the proper signal to indicate its own mode of operation the P1 Manual MAN DIP Switch position should be selected to force Full Duplex mode Page 10 GX F SPECIFICATIONS Model Type GX F 1000BASE SX LX 100BASE FX Fiber SC LC Connectors Single Fiber SC BP Enable LS LP RFD F O Auto Man F O FDX HDX Dimensions _W 0 85 x D 4 5 x H 2 8 mm e Power F 1 5A 3 3VDC pica C Standard 0 to 50 Temperature Wide 40 to 60 C Storage 40 to 80 C 5 to 95 non condensing MTBF hrs 730 000 Protocols Controls
5. implied warranties of merchantability and fitness for any particular purpose Page 15 LED INDICATORS LED COLOR DESCRIPTION Pwr Yellow On Power F O P1 FDX Green On Full Duplex detected F O P1 Lk Act Green On Link Blink activity F O P2 Lk Act Green On Link Blink activity F O P2 FDX Green On Full Duplex detected Page 12 Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory TECHNICAL SUPPORT For help with this product contact our Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr Irvine CA 92618 USA E mail support omnitron systems com URL www omnitron systems com Form 040 08560 001D 12 12 Page 16
6. 30km 1310nm 41310nm 8563 11 8567211 SM 12km SM 60km 1310m 13100m 9563312 8361 12 SM 12km SM 120km For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for Cae temperature 40 to 75 C models When using single fiber SF media converter models the Tx wavelength on one end has to match the Rx wavelength on the other 162 5 125um 100 140um multimode fiber up to 220m 50 125um multimode fiber up to 550m Refer to the fiber cable manufacturer for multimode distance specifications Please contact Omnitron for other configurations Page 3 front plane port and a loss of a received Link at one port causes the other front plane port to drop its link out For example P2 transmits a Link only when receiving a Link at P1 Fig 2 c In Remote Fault Detection Link Segment RFD LS the fiber port transmits a Link signal only when receiving a Link at the fiber port As a result fiber faults no Link received at the fiber are looped back and can be reported to the network core Fig 2 d In Remote Fault Detection Link Propagate RFD LP mode the P1 port transmits a Link signal only when both it and P2 are receiving Link signals A loss of a received Link signal at P1 is Looped back to P1 and propagated to P2 causing both to stop transmitting the Link signal Fig 2 e Also the loss of a received Link at P2 is propagated to both P1 and P2 which stop transmitting the
7. Ethernet switch with one Gigabit fiber uplink port and one Fast Ethernet fiber port This example shows how the GX F can be used as amanaged or unmanaged media converter or as a building block in creating flexible and effective network switch configurations For more information about individual chassis A and B backplane links refer to the specific chassis user manual LINK MODES In order to accommodate different user needs the GX F supports five different linking modes see Fig 2 In Link Segment LS mode Normal mode a port transmits a Link signal independently of any received Link at any port For example P2 transmits a Link regardless of the receiving of a Link at P1 Fig 2 a amp 2 b In Link Propagate LP mode sometimes referred to as Link Loss Carry Forward a port transmits a Link signal only when receiving a Link on the other Page 6 GX F MODEL NUMBER REFERENCE CHARTS iConverter GX F Dual Fiber Converters Connector Types P1 P2 Port 1 1000X Port 2 100FX Fiber Type Fiber Type Distance Distance Wavelength Wavelength Sc SC LC LC MM 220m MM 5km 550m 850nm 4310nm 8562 00 MM 220m SM 30km 550m 850nm 41310nm 8562 01 MM 220m SM 60km 550m 850nm 1310nm 8562 02 MM 220m SM 120km 550m 850nm 1550nm 8562 03 SM 12km MM 5km 1310nm 1310nm 8563 10 SM 12km SM
8. duct is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM You may also register your product on the Internet at www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the
9. on connected device Fig 2 GX F Link Modes Page 8 DIP SWITCH SETTINGS Front Panel DIP Switch Settings Link Segment LS E LP Link Propagate Off I RFD Remote Fault Detect Off _ SFO Symmetrical Fault Detect Fig 3 Front Panel DIP Switches Link Segment Link Propagate LS LP DIP Switch This DIP Switch controls the Link Propagate or Link Segment modes When the DIP Switch is in the LS position factory setting Link Segment mode is enabled In the LP position Link Propagate mode is enabled Remote Fault Detection RFD DIP Switch To enable Remote Fault Detection mode set the RFD DIP Switch to the RFD position To enable RFD LS mode also set the LS LP DIP Switch to the LS position To enable RFD LP mode set the LS LP DIP Switch to the LP position The RFD DIP Switch selection is ignored on ports set to Auto Negotiation mode NOTE Connecting two converters with both set to RFD mode is not supported and will cause a deadly embrace lockup Symmetrical Fault Detection SFD DIP Switch To enable Symmetrical Fault Detection mode set the SFD DIP Switch to the SFD position the LS LP DIP Switch to the LS position and the RFD DIP Switch to the Off position Any other DIP Switch configuration will disable Symmetrical Fault Detection mode Page 9 MOUNTING AND CABLE ATTACHMENT The iConverter GX F module
10. osr Omnitron Systems Technology Inc iConverter GX F User Manual Port 2 P2 Fast Ethernet 1 or Port 1 P1 Gigabit 1000X ABOUT THIS MANUAL This document supports revision xx 10 of the GX F Please refer to the serial number label on the GX F for the revision number of your product This revision incorporates the following improvements to the GX F 1 Product enhancements now prevent unpredictable behavior under undefined or incompatible DIP Switch selections 2 LINK MODES have been increased to include RFD LS and RFD LP modes Improvements to LED behavior have been made to accommodate these new link modes OVERVIEW The iConverter GX F media converter provides Gigabit 1000X fiber to Fast Ethernet 100FX fiber conversion It is a member of the modular iConverter product family and supports multimode single mode and single fiber options The iConverter GX F repeats regenerates and re times the fiber optic signal and multiple GX F repeaters can be cascaded to extend total network distances Page 1 PORT STRUCTURE Using a 4 port switch design the GX F features a front plane 1000Mbps Gigabit fiber port P1 a 100Mbps Fast Ethernet fiber port P2 and two 10 100 Ethernet backplane copper ports A and B that can connect to adjacent modules within the same chassis When the GX F A and B Ethernet backplane ports are enabled using the BPAEN and BPBEN DIP Switches
11. s are hot swappable and can be installed into any iConverter chassis To install in a chassis perform the following steps 1 Slide the iConverter module into the selected slot while aligning it with the installation guides Ensure that the module is firmly seated against the backplane 2 Secure the module to the chassis using the panel fastener screw attached to the module 3 Connect an appropriate multimode or single mode fiber cable to the Gigabit P1 fiber port 4 Connect the cable to a compatible Gigabit device 5 Connect an appropriate multimode or single mode fiber cable to the 100BASE FX P2 fiber port 6 Connect the cable to a compatible 100BASE FX device NOTES Each transmit Tx port must connect to the receive port of the attached device the receive Rx port must connect to the transmit port When using single fiber SF models the Tx wavelength on one end must match the Rx wavelength on the other and the converters must be used in matched pairs example model 8562 05 must be matched with model 8562 07 Page 13 NOTE Converters in SFD mode must be deployed in pairs Board Mounted DIP Switches ON BPAEN Backplane A Enabled CE BPBEN Backplane B Enabled CE MAN P1 Manual C off Off P1 Auto Negotiate AN P2 Full Duplex FD HD P2 Half Duplex ONOMARWN gt Fig 4 Board Mounted DIP Switches Backplane A Enable BPAEN DIP
12. they connect via the chassis backplane to the slots on the left and right sides of the GX F module When another switch based module with backplane ports such as a second GX F or an NMM is installed in an adjacent slot it can be connected via the backplane to the GX F to form a multi module configuration GX F Application Example Slot 1 odd Slot 2 even Slot 3 odd A Li Chassis ink B Link Backplane Internal Internal 10 100 1000 10 100 switch chip switch chip NMMUTP Fiber Fiber 4 port 10 100 UTP 10port 1000port 100 port Switch NMM Module GX F Module 4Tx Module Fig 1 In Band Managed GX F Application Page 5 Using its switch based architecture the GX F can be used as a two port fiber converter or using its two additional 10 100 Ethernet backplane ports it can connect to adjacent modules and accommodate In Band management or multi module configurations the different iConverter Chassis models provide backplane links to connect between adjacent modules The GX F can be used in an unmanaged or managed fashion When unmanaged it can be installed in a chassis without a management module To be managed a Network Management Module NMM or an iConverter module with built in management such as a 10 100M or GX TM must be installed in the same chassis Advanced Features The GX F features Port VLAN and Tag VLAN which allow control of traffic flow between both the fiber por
13. ts and the backplane ports It also features Port Access Control which facilitates enabling and disabling of individual ports The GX F supports reporting of MIB statistics Statistics are available for 32 variables per port reporting a wide range of real time packet statistics to provide performance and operational monitoring NOTE Using the advanced features listed above requires management via an NMM or an iConverter module with built in management such as a 10 100M or a GX TM and NetOutlook Management Software a third party SNMP management software or Telnet For more information on using and configuring these advanced features please refer to the NetOutlook Management Software user manual Page 2 Fig 1 depicts a chassis with three modules plugged into three of its adjacent backplane slots beginning with an odd numbered slot The adjacent slots are connected via the backplane using the A and B 10 100 links In this example the GX F in the center slot connects to the slot on its left using the A link and to the slot on its right using the B link The module on the left is a Network Management Module NMM connecting via its A backplane port to the GX F facilitating In Band management via the fiber uplink The module on the right is a 4 port 10 100 switch module 4Tx connecting to the GX F via its B port This 3 module configuration forms an effective managed 4 port 10 100