Home

Argoclima Hi Fan Digit Plus

image

Contents

1. 2 2 2 800 8 digit Plus CERAMIC HEATER V01 09 HiFan Digit Plus EG_2009_v2 indd 1 29 06 2009 15 53 13 ee READ AND SAVE THESE INSTRUCTIONS Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain these instructions for future reference GENERAL SAFETY INFORMATION lej CB 30 aoe AON 7 8 OR CE ON OFF MODE switch Timer knob Infrared receiver Front netting Base LCD knob Swing knob knob 10 Power switch 11 Front enclosure 9 12 Rear enclosure ci 13 Power cord FAN Low HGH AUTO AI N O OT EO O gt 65 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to people Make certain that the power source conforms to the electrical requirements of heater AC220 240V 50Hz Extreme
2. regulation of the desired temperature min 1h max 24h Q In order to activate the automatic switching off press the timer key and set the keys regulation and 4 In order to deactivate the timer set it at Oh with the regulation key Press the key swing in order to activate deactivate the function a WHEN THE HEATER SWITCHES OFF THE FAN WILL CONTINUE TO WORK FOR SOME SECONDS IN ORDER TO COOL AND PROTECT THE CERAMIC RESISTANCE DO NOT SWITCH THE HEATER DIRECTLY BY THE SWITCH ON THE REAR OR UNPLUGGING THE APPLIANCE THE SET TEMPERATURE AND THE TIMER WILL BE BROUGHT BACK TO THE DEFAULT SETTINGS EVERY TIME THE ELECTRICAL SUPPLY IS REMOVED HiFan Digit Plus EG_2009_v2 indd 3 29 06 2009 15 53 16 REMOTE CONTROL The opreation of the ceramic heater can be controlled even by the infrared remote control The operation of the keys is same as explained in the paragraph OPERATION The remote control works with bacteries AAA In order to insert the batteries please remove the cap on the rear and respect the pointed our polarities Please remove the bacteries from the remote control when it is not used for a long period of time Do not thown into the environment the exhausted batteries RESET INSTRUCTION When an overheat temperature is reached the heater will be automatically shut off 1 Unplug the heater and wait 5 10 minutes for the unit to cool down 2 After 5 10 minutes plug the unit in aga
3. USER MANUAL 0 4 0 4 0 4 0 4 2 4 2 4 2 2 000000000000001 6 2
4. caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating unattended To reduce the risk of electric shock this plug is intended to fit in a correct outlet If the plug of heater does not fit fully in the outlet contact a qualified electrician Do not attempt to defeat this safety feature Where possible avoid to use of extension cords because the extension cord may overheat and cause a risk of fire Never use a single exten sion cord to operate more than one heater Do not operate heater with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner Return heater to an authorized service facility for examination electrical or mechanical adjustment or repair If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Turn off the power switch and unplug power cord before servicing or moving the heater Always unplug heater when not in use WARNING DO NOT DEPEND ON THE ON OFF BUTTON SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN SERVICING OR MOVING THE HEATER ALWAYS UNPLUG THE POWER CORD 9 10 11 12 13 14 15 16 17 18 19 To disconnect heater turn switch to off position then remove plug from outlet Pull only by the plug Do not pull on the cord when discon nect heater Do not insert or allow fingers or foreign
5. in and operate normally MAINTENANCE SWITCH AIR EXIT AIR INLET PLUG WARNING ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING MAINTENANCE DO NOT IMMERSE HEATER IN WATER CLEANING Clean the filter net at least once a month more often if dirty A dirty filter could restrict the air flow and cause the heater to function improperly or shut down Do not attempt to remove inlet grill from the heater 1 Unplug the heater from power source 2 Vacuum rear grill area of heater with vacuum brush attachment to remove lint and dirt from internal filter Do not remove grill guard or allow heater to be operated without grill guard in place 3 Clean the body with a soft cloth NEVER USE ALCOHOL OR SOLVENTS STORAGE Store the heater with these instructions in the original carton in a cool dry place argo www argoclima com MADE IN CHINA 01 09 HiFan Digit Plus EG_2009_v2 indd 4 29 06 2009 15 53 19
6. objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or da mage the heater Do not block or tamper with the heater in any manner while it is in operation To prevent a possible fire do not block air intakes or exhaust in any manner Do not place heater on soft surfaces like a bed where ope nings may become blocked Always place the heater on a stable flat level surface when operating to avoid the chance of the heater overturning Locate the power cord so the heater or other objects are not resting on it Do not run power cord under carpeting Do not cover power cord with throw rugs runners or the like Arrange power cord away from room traffic and where it will not be tripped over This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Always use handle when moving this heater Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 0 9m from the front of the heater and keep them at least 0 3m from the sides and rear A heater has hot and arcing or sparking parts inside It must not be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmosphere This heater is not intended for use in wet or damp locations Never locate a heater where it may fall into a bathtub or other water container Do not use this heater in the immediate surroundings of a bath a shower or a swimming pool Do not
7. use heater outdoors In order to avoid overheating do not cover the heater The heater must not be located immediately below a socket outlet WARNING REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS HEATER WITH ANY SPEED CONTROL DEVICES HiFan Digit Plus EG_2009_v2 indd 2 29 06 2009 15 53 15 V01 09 OPERATION When the heater is plugged in and open the power switch on the rear of the unit base the LCD will be in sleeping mode 2 seconds and will show ambient temperature KEY REGULATION KEY SWING MODE Swa lc KEY TIMER CD 30 ic4 00 KEY REGULATION TEMPERATURE TIMER gt KEY ON OFF MODE Press key ON OFF MODE in order to activate the appliance and change the working mode as described here below 4 FAN 4 LOW 4 HIGH 4 AUTO cp op Co dE 3r FAN ONLY LOW POWER HIGH POWER AUTO dem 3 sTanD BY Q Press the regulation keys in order to set the desired temperature AUTO mode The temperature can be set from 5 C useful as anti freeze up to 40 C the default temperature is 30 C The AUTO function manages the fan heater power according to the desired temperature once achieved the set Q temperature the fan heater modulates the power to maintain a constant temperature in the room This feature Tian improves your comfort and reduces energy consumption

Download Pdf Manuals

image

Related Search

Related Contents

  USER MANUAL  none BioStar Use and Care Manual  SAGA1-L40 (取扱説明書)    User manual - 07/2012    

Copyright © All rights reserved.
Failed to retrieve file