1. To attach the rail plates 1 Attach a rail plate to an appliance rail using two appliance rail screws 2 Do step 1 again for the other rail plate and appliance rail This figure shows the assembled rail plate and appliance rail Attaching the Appliance Rails to the Appliance Attach the appliance rails to the sides of the appliance Position the rail plates to connect the appliance rails to the rear of the rack S Note The appliance rail screws have 8 mm heads To attach the appliance rails 1 Set the appliance rail on the side of the appliance The ridges on the appliance rails point to the appliance This diagram shows the appliance rail and rail plate positioned correctly 2 Attach the appliance rails to the appliance using three appliance rail screws 3 Do steps 1 and two again for the other side of the appliance Rack Mounting Page 13 Rack Mounting Check Point 12200 Installing the Appliance in the Rack Install the appliance in the rack It may be necessary to adjust the appliance rails to secure the appliance to the rack Important Two people are required to install the appliance in a rack in order to prevent A personal injury or damage to the appliance To install the appliance in the rack 1 Attach the ear mount brackets to the front of the rack 2 Attach the rail plates to the rear of the rack 3 Confirm that the appliance is stable and secure in the rack Rack Mounti
2. Expansion Line Card Options Expansion line cards can have two four or eight ports These types of expansion line cards are available Model CPAC 2 10F CPAC 4 1C CPAC 4 1F CPAC 4 10F CPAC 8 1C Description 2 Port 10GBase F SFP without transceivers 4 Port 10 100 1000Base T RJ 45 4 Port 1000Base F SFP without transceivers 4 Port 10GBase F Ethernet PCl e SFP 8 Port 10 100 1000Base T RJ 45 Check Point 12400 Front Panel ltem Component 2 Hard disk drives System LEDs LCD screen Keypad Console port Management port Description When monitoring the disks using the raid diagnostic command DiskID 0 is the top disk and DiskID 1 isthe bottom disk System power system status and hard disk activity Perform basic management operations Using the LCD Panel on page 28 For a serial connection to the appliance using a terminal emulation program such as HyperTerminal For an Ethernet connection to a remote management computer Check Point 12000 Appliances Hardware Page 24 Front Panel Components ltem 10 11 12 Component LOM port Expansion line card USB ports Synchronization port Expansion line card Expansion line card Description LOM Light Out Management port for the optional LOM card 8 Port 10 100 1000Base T RJ 45 Model CPAP ACC 8 1C For synchronizing with cluster members or a high availability peer Expansion slot Expansion slot Expansion Lin
3. Equipment The product herewith complies with the requirements of the EU Directive 2006 95 EC and the EMC Directive 2004 108 EC Date and Place of issue July 2011 Tel Aviv Israel FCC Notice US This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment Compliance Information Page 39
4. The server used by the system administrator to manage the security policy The organization s databases and security policies are stored on the Security Management Server and downloaded to the gateway SmartConsole GUI applications that are used to manage various aspects of security policy enforcement For example SmartView Tracker is a SmartConsole application that manages logs SmartDashboard A SmartConsole GUI application that is used by the system administrator to create and manage the security policy Locally Managed Deployment The appliance is a Security Gateway and a Security Management server The Security Management server manages the Security Policy that is enforced by the Security Gateway Centrally Managed Deployment The appliance is a Security Gateway without a Security Management server The Security Gateway is managed by a remote Security Management server Introduction Page 10 Chapter 2 Rack Mounting This chapter describes how to mount the appliance in a rack A Important Two people are required to install the appliance in a rack in order to prevent any possible damage In This Chapter Rack Mounting Hardware and Tools 11 Rack Mounting Check Point 12200 12 Rack Mounting Check Point 12400 and 12600 15 Rack Mounting Hardware and Tools You must install rack mounting hardware on the appliance before you can mount it in a rack This table describes the rack mounting hardware Note Screws to attach the
5. a ite ee Sec Sep cite neem a eaaa aaa aaa a cect bce Aaaa E aeaaaee ae Katai aeai 9 WVGIC OIG E AE AE E EAE EE E EA AE EA AE AE Mote 9 Check Point 12000 Appliances Overview ssssssesssesssssenerrrrrsserrrrrrnnrrsserrrrrrnn 9 Shipping Carton Coments a E tea asl ote ates EE 10 Termino GY a ena AE p TE AEE eee a EE ETE 10 Rack MOUNINO ee arraira heath ace ee eee te ce eke 11 Rack Mounting Hardware and TOOIS cecceeeeeeeeeeeeeeeeeeeeceeeeeeeeeeeseeenneeeeeeeees 11 Rack Mounting Check Point 12200 0 cceeeeeeeeeeee cece eee eeeeeenaeeeeeeeeeeetenennaneeeeeees 12 Attaching the Ear Mount Brackets to the Appliance ccceeeeeeessteeeeeees 12 Attaching the Rail Plates 3st lit Se he ost ca ven deni erasable dewedeeoremss cael de ope cee 12 Attaching the Appliance Rails to the Appliance ccceeeceeeeeeeeeeeeteeeeeeeees 13 Installing the Appliance in the Rack cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeees 14 Rack Mounting Check Point 12400 and 12600 00 eeeeeeeeeeeeeeeeeeeeeeeeentneeeeeeees 15 Attaching the Ear Mount Brackets to the Appliance ccceeeeeestteeeeeeees 15 Attaching the Rail Plates oo edeanettecres cts decersnetes cst tee hewevnosact ed oieacetnartantactaedstiee 15 Attaching the Appliance Rails to the Appliance c ceeeeeeeeeeeeeeeenteeeeeeees 16 Installing the Appliance in the Rack cccccceeeeeeeeeeeeeeeeeeeeeeeeeesessaaeeeeeeees 17 C
6. ear mount brackets and rail plates to the rack are not included Hardware Description Qty Use Ear mount bracket 2 Attaches to the appliance front panel Both ear mount brackets are identical Ear mount screws 6 Secures the ear mount brackets to the appliance front panel Appliance rail 2 Attaches to the appliance Both rails are identical Rail plates 2 Attaches to the appliance rails Both plates are identical Appliance rail screws 14 Secures the rail plates to the appliance rails and the rails to the appliance Rack Mounting Tools Philips screwdriver A magnetic head is recommended to hold screws in place and retrieve dropped screws A powered screwdriver is also useful Page 11 Rack Mounting Check Point 12200 Rack Mounting Check Point 12200 Attaching the Ear Mount Brackets to the Appliance Attach the two ear mount brackets to the front of the appliance Q5 Note The ear mount screws have 5 mm heads To attach the ear mount brackets to the appliance 1 Attach the appliance ear bracket to one side of the appliance using three ear mount screws 2 Do step 1 again for the other side of the appliance Attaching the Rail Plates Attach the rail plates to the appliance rails to connect the appliance to the rear vertical rails of the rack gt Item Description 1 Appliance rail 2 Rail plate SS Note The appliance rail screws have 8 mm heads Rack Mounting Page 12 Rack Mounting Check Point 12200
7. metal cover on the front of the appliance Holding the screws remove the metal cover Insert the expansion line card into the expansion slot Push until the card clicks into place Tighten the retaining screws on the expansion line card Customer Replaceable Parts Page 31 Replacing Hard Disk Drives on Check Point 12200 Replacing Hard Disk Drives on Check Point 12200 This section describes how to remove or install a hard disk drive in a Check Point 12200 appliance Removing a Hard Disk Drive To remove a hard disk drive in a Check Point 12200 1 Using the key supplied in the toolkit unlock the drive 2 Slide the release latch toward the left The extraction handle pops out 3 Using the extraction handle remove the drive from the slot Installing a Hard Disk Drive To install a hard disk drive in a Check Point 12200 1 Slide the replacement hard disk drive into the slot 2 Push the extraction handle until it closes and the drive clicks into place 3 Using the key supplied in the toolkit lock the new drive Replacing Hard Disk Drives on Check Point 12400 and 12600 This section describes how to remove or install a hard disk drive in a Check Point 12400 or 12600 appliance Customer Replaceable Parts Page 32 Replacing Hard Disk Drives on Check Point 12400 and 12600 Removing a Hard Disk Drive To remove a hard disk drive from a Check Point 12400 or 12600 1 Using the key supplied in
8. terminal emulation software such as HyperTerminal and PuTTY from Windows or Minicom from Unix Linux systems e Connection parameters for the appliance are 9600bps no parity 1 stop bit 8N1 e Set the Flow Control to None An SSH connection to the management interface if SSHD is configured Configuring Check Point 12000 Appliances Page 22 Chapter 4 Check Point 12000 Appliances Hardware This chapter provides instructions for installing and removing hardware components on Check Point 12000 Appliances In This Chapter Front Panel Components 23 Rear Panel Components 27 Using the LCD Panel 28 Front Panel Components The section describes the hardware on the front panel of the appliance Check Point 12200 Front Panel AeA A a e IHLE h L a L 5 l 9 a eg Item Component Description 1 Expansion line card Expansion slot 2 LOM Port LOM Light Out Management port for the optional LOM card 3 Built in Ethernet ports ETH1 ETH7 4 Management Ethernet connection to a remote management workstation configuration port 5 USB ports 6 Console port A serial connection to the appliance using a terminal emulation program such as HyperTerminal or PuTTY 7 System LEDs System power system status and hard disk activity 8 LCD display screen Page 23 Front Panel Components ltem 9 Component Keypad Description Perform basic management operations Using the LCD Panel on page 28
9. 55 0 This can be changed in the WebUI To access the management interface open a connection from a browser to the default management IP address https 192 168 1 1 4434 Ss Note Pop ups must always be allowed on https lt appliance ip address gt The login page opens Log in to the system using the default login name password admin admin and click Login Configuring Check Point 12000 Appliances Page 19 Using the First Time Configuration Wizard Ss Note The features configured in the wizard are accessible after completing the wizard via the WebUI menu The WebUI menu can be accessed by navigating to https lt appliance ip address gt 4434 5 Change the administrator password as prompted The default password gives you access to the appliance For security purposes you must change it to a more secure password In the Password recovery login token section you can download a Login Token that you can use if you forget the password We highly recommended to save and safely store the password recovery login token file 6 The First Time Configuration Wizard runs The First Time Configuration Wizard presents windows that help you to configure the appliance Welcome The Welcome page summarizes the steps of the First Time Configuration Wizard Appliance Date and Time Setup Configure date and time in the Date and Time Setup page Click Apply Network Connections Configure the network connections in the Network Con
10. 76 0200 Network Cntrlir 10 7 13 i 8086 18076 0200 Network Cntrlr 11 ACPI Controller 9 Press any key to see the boot menu Booting 1n 4 seconds 8 At this point you have approximately four seconds to hit any key to activate the Boot menu 9 The Boot menu opens Scroll to the relevant Reset to factory defaults image and press Enter Restoring Using the LCD Panel To restore the appliance to its default factory configuration using the LCD Panel keys 1 Reboot or power on the appliance 2 When the countdown begins press any of the arrow keys Starting in A 5 seconds a or D y 3 Using the arrow buttons scroll to the relevant default factory image 4 Press a 5 Confirm the reset by pressing a Pressing any other button causes the Action Canceled message to display Action Canceled A Press any key a ere D OY At this point pressing any key returns you to the boot menu Restoring Factory Defaults Page 35 Restoring Using the LCD Panel 6 Once you have confirmed the reset wait for the appliance to restore the factory image While the appliance is restored to the default image this message is continuously displayed Reverting image don t turn off After the appliance is restored to its default factory configuration the appliance reboots and the initializing message appears Restoring Factory Defaults Page 36 Chapter 6 Registration and Support In This Chapter Registration 37 S
11. CI V 3 Class A Information Technology Equipment Radio Disturbance Characteristics AS NZS CISPR22 Class A Information Technology Equipment Radio Disturbance Characteristics ICES 003 Class A Information Technology Equipment Radio Disturbance Characteristics CISPR22 Information Technology Equipment Radio Disturbance Characteristics EN55022 Class A Information Technology Equipment Radio Disturbance Characteristics EN 61000 3 2 Information Technology Equipment Harmonics Characteristics EN61000 3 3 Information Technology Equipment Flicker Characteristics EN 55024 Information Technology Equipment Immunity Characteristics Page 38 Declaration of Conformity EN61000 4 2 Information Technology Equipment Electrostatic Discharge Immunity EN61000 4 3 Information Technology Equipment Radiated RF Immunity EN61000 4 4 Information Technology Equipment Fast Transient Immunity EN61000 4 5 Information Technology Equipment Surge Immunity EN61000 4 6 Information Technology Equipment Conducted RF Immunity EN61000 4 11 Information Technology Equipment Voltage Dips and Short Interruptions Immunity Safety CAN CSA C22 2 No 60950 Safety of Information Technology Equipment 1 07 UL 60950 1 2007 second Safety of Information Technology Equipment edition EN 60950 1 2006 A11 2009 Safety of Information Technology
12. Check Point 12000 Appliances Getting Started Guide 31 October 2011 softwareblades Check Point a SOFTWARE TECHNOLOGIES LTO We Secure the Internet Models P 210 P 220 and P 230 2011 Check Point Software Technologies Ltd All rights reserved This product and related documentation are protected by copyright and distributed under licensing restricting their use copying distribution and decompilation No part of this product or related documentation may be reproduced in any form or by any means without prior written authorization of Check Point While every precaution has been taken in the preparation of this book Check Point assumes no responsibility for errors or omissions This publication and features described herein are subject to change without notice RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 and FAR 52 227 19 TRADEMARKS Refer to the Copyright page http www checkpoint com copyright html for a list of our trademarks Refer to the Third Party copyright notices http Awww checkpoint com Srd_party_copyright html for a list of relevant copyrights and third party licenses Important Information Latest Software We recommend that you install the most recent software release to stay up to date with the latest functi
13. aaeceitedaeaass 23 Check Point 12400 Front Panel ccccccceeeeeeeeeeeeeeceeeeeeeeeeesenaaeeeeeeeeeeenees 24 Check Point 12600 Front Panel 2 4 owe exteoea londeceakaddeea hace 25 Rear Panel Components oxtecas cede cidaccutsi cect viodactideniareiandaccedtiganviadadelesaiee 27 Check Point 12200 Rear Panel sc cacendinte cee adit eel Ate 27 Check Point 12400 and 12600 Rear Panel cccceeeeeeeeeeeeeeeeeeeeeeeeeeees 27 Using the LOD Panel isese iere aaee EEEE E EAEE EEEREN 28 Customer Replaceable Parts seecccceeeseeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeeseseeneeeeeeees 29 Replacing Power Supplies cccccceeeeeeeeeeecceeeeeeeeeeeeeneaaaeeeeeeeeeesnessaaaeeeeeees 29 Removing Power Supplies xc ce drat etree eats teehee ds otetet Gasca epetlae urtgadi cee 30 Installing Power Supplies ix cess chi auactia eovntts seu adeer veda ernde eevee cael dee ope ere 30 Replacing Expansion Line Cards z2isnacticrcn ees heen caai eck haut ence Mees 30 Removing Expansion Line Cards cccccccecesscccceeeeeeeeeeeesaeeeeeeeeeeeeenesaaaaes 31 Installing Expansion Line Cards ccccceeeeccecccceeeeeeeeeeseneeeeeeeeeeeeeeesnaaeeeeeees 31 Replacing Hard Disk Drives on Check Point 12200 c ceeeeeeeeeeeeeeeteeeeeeeees 32 Removing a Hard Disk Drive c cccceeeeeeeeeeececeeeeeeeeeeesssaaeeeeeeeeeeeeennsaaaees 32 Installing a Hard Disk Drive wcieit aecce comedies Mice eeinatli domme eim
14. ame key is used by the gateway object in SmartDashboard Summary The Summary page opens Click Finish to complete the First Time Configuration Wizard You can login to the appliance after several minutes Q5 Note You should backup the system configuration The Backup and Restore window can be accessed via the WebUl interface Appliance gt Backup and Restore Creating the Network Object Configure the Check Point 12000 Appliances as a gateway object in the Security Management Server database To create the network object in SmartDashboard T 2 3 4 on Launch SmartDashboard Configure a new gateway object for the appliance Enter the IP address for the appliance For a centrally managed installation establish Secure Internal Communication SIC using the activation key entered in the First Time Configuration Wizard Configure the topology Install the security policy Advanced Configuration Advanced configuration can be done using the sysconfig menu which can be accessed using the command line interface only For example configuring the appliance to be a DHCP server Q5 Note The sysconfig menu is only available after running the First Time Configuration Wizard in the WebUl CLI access can be obtained by console connection or through SSH Connecting to the CLI You can connect to the command line interface of Check Point 12000 Appliances using The provided serial console cable DTE to DTE and
15. are generally sufficient to protect your equipment from static electricity discharge When handling the board to use a grounded wrist strap designed for static discharge elimination Touch a grounded metal object before removing the board from the antistatic bag Handle the board by its edges only Do not touch its components peripheral chips memory modules or gold contacts When handling processor chips or memory modules avoid touching their pins or gold edge fingers Restore the communications appliance system board and peripherals back into the antistatic bag when they are not in use or not installed in the chassis Some circuitry on the system board can continue operating even though the power is switched off Under no circumstances should the lithium battery cell used to power the real time clock be allowed to short The battery cell may heat up under these conditions and present a burn hazard A Warning DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS Disconnect the system board power supply from its power source before you connect or disconnect cables or install or remove any system board components Failure to do this can result in personnel injury or equipment damage Avoid short circuiting the lithium battery this can cause it to superheat and cause burns if touched Do n
16. at can be used to perform basic management operations You can select DHCP or configure the IP address subnet netmask and default gateway of the management interface The appliance can also be rebooted Menu Options Menu Sub menu Network DHCP Set Mgmt IP Set Netmask Set Default GW System Reboot LCD Panel Keys To Enter the main menu Navigate the menu Change a number Select a menu option Go back to previous menu Purpose Enable or disable DHCP for the management interface Set the management interface IP address Set the management interface network mask Set the management interface default gateway Reboot the appliance Press AV gt When Entering an IP Address To Enter the grub menu Move to the next digit Move back to the previous digit Approve the change Cancel the IP change Press MD D Ql when the cursor is located on the last digit when the cursor is located on the first digit Check Point 12000 Appliances Hardware Page 28 Replacing Power Supplies To Press Change current digit a J or Customer Replaceable Parts To ensure maximum availability and ease of maintenance the Check Point 12000 Appliances contain the following customer replaceable parts 12200 12400 12600 Power supply units 1 Power supply unit 2 2 1 Place holder unit Expansion line card 1 1 2 optional slots 2 1 optional slot Hard disk drives 1 1 optional slot 1 1 o
17. e Card Options Expansion line cards can have two four or eight ports These types of expansion line cards are available Model CPAC 2 10F CPAC 4 1C CPAC 4 1F CPAC 4 10F CPAC 8 1C Description 2 Port 10GBase F SFP without transceivers 4 Port 10 100 1000Base T RJ 45 4 Port 1000Base F SFP without transceivers 4 Port 10GBase F Ethernet PCl e SFP 8 Port 10 100 1000Base T RJ 45 Check Point 12600 Front Panel ltem 1 2 Component 2 Hard disk drives System LEDs Description When monitoring the disks using the raid_diagnostic command DiskID 0 is the top disk and DiskID 1 isthe bottom disk System power system status and hard disk activity Check Point 12000 Appliances Hardware Page 25 Front Panel Components Item Component Description 3 LCD screen 4 Keypad Perform basic management operations Using the LCD Panel on page 28 5 Console port For a serial connection to the appliance using a terminal emulation program such as HyperTerminal 6 Management port For an Ethernet connection to a remote management computer 7 LOM port LOM Light Out Management port for the optional LOM card 8 Expansion line card 8 Port 10 100 1000Base T RJ 45 Model CPAP ACC 8 1C 9 USB ports 10 Synchronization For synchronizing with cluster members or a high availability peer port 11 Expansion line card 4 Port 10 100 1000Base T RJ 45 Model CPAP ACC 4 1C 12 Expansion line card Expansion slot Expansi
18. enoedietss 32 Replacing Hard Disk Drives on Check Point 12400 and 12600 eee 32 Removing a Hard Disk Drive cic dcccne gett deste ny ies sedan cere pinaleudes cade dete deeteticces 33 Installing a Hard Disk Drive yecceic sccecctecviedestedecttecetweteeheteceinchihndeededuasancceedeabes 33 Restoring Factory Defaults cccccccsssseeeeeeeeeeeeeeeeseeeeeeeeeeeeeesseneeeeeeeeeeseeeeenees 34 Restoring Using the WebUl sitesi aisces Lecce vent A cat ceca cee ais eae 34 Restoring Using the Console Boot Menu ccceceessssseeceeeeeeeeeeesesnaeeeeeeeees 34 Restoring Using the LCD Panelixc1s ccnra cei nenatieae a eeh baeeiyrsea oie tae ce ees 35 Registration and SUpport ivcssiccccsid eceeeciece ee ieectehd ec ketene 37 Registration enin cet eva E R E cratneehe ERRE 37 S102 0101 p PESE EAEE EE E E E E E E A E E ee eer E E 37 Where To From Heie2 i anit tet eta a ei eleces eieeton nt cacleten eas 37 Compliance Information siscecccicciccccsseiees cete des eehest este eeedeeneeiesie tlie nseeeele nein 38 Declaration of Conformity sseseeicionadtsaSonnebeceteadeie huss td manatee tagaael Ataesaetagesteebengete eal 38 Chapter 1 Introduction In This Chapter Welcome 9 Check Point 12000 Appliances Overview 9 Shipping Carton Contents 10 Terminology 10 Welcome Thank you for choosing Check Point 12000 Appliances We hope that you will be satisfied with this system and our support services Check Point products
19. er than direct connections to the branch circuit e g use of power strips For California Perchlorate Material special handling may apply See http www dtsc ca gov hazardouswaste perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials This product part or both may include a lithium manganese dioxide battery which contains a perchlorate substance Proposition 65 Chemical Chemicals identified by the State of California pursuant to the requirements of the California Safe Drinking Water and Toxic Enforcement Act of 1986 California Health amp Safety Code s 25249 5 et seq Proposition 65 that is known to the State to cause cancer or reproductive toxicity see http Awww calepa ca gov WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling Federal Communications Commission FCC Statement For a Class A digital device or peripheral Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can
20. g three appliance rail screws 3 Do steps 1 and 2 again for the other side of the appliance Rack Mounting Page 16 Rack Mounting Check Point 12400 and 12600 Installing the Appliance in the Rack Install the appliance in the rack It may be necessary to adjust the appliance rails to secure the appliance to the rack A Important Two people are required to install the appliance in a rack in order to prevent personal injury or damage to the appliance To install the appliance in the rack 1 Attach the ear mount brackets to the front of the rack 2 Attach the rail plates to the rear of the rack 3 Confirm that the appliance is stable and secure in the rack Rack Mounting Page 17 Chapter 3 Configuring Check Point 12000 Appliances The workflow for configuring Check Point 12000 Appliances is 1 Connect the cables and power on the appliance 2 Use the First Time Configuration Wizard to configure the appliance 3 Add the Check Point 12000 Appliances object in SmartDashboard and install a policy In This Chapter Powering On Using the First Time Configuration Wizard Creating the Network Object Advanced Configuration Powering On To power on Check Point 12000 Appliances 1 Connect the power cable 2 On the back panel turn on the Power button to start the appliance Q5 Note When a power supply fails or is not connected to the outlet an alarm sounds continuously If you hear the alarm replace the faulty
21. ion using the console boot menu 1 Connect the supplied DB9 serial cable to the console port on the front of the appliance 2 Connect to the appliance using a terminal emulation program such as Microsoft HyperTerminal or PuTTY 3 Inthe HyperTerminal Connect To window select a port from the Connect using list Define the port settings 9600 BPS 8 bits no parity 1 stop bit 4 From the Flow control list select None Click Call gt Call to connect to the appliance 6 Switch on the appliance The appliance begins the boot process and status messages appear in HyperTerminal o Page 34 Restoring Using the LCD Panel 7 During the boot process text similar to that shown below appears IDE Channel 2 Master Disk LBA ATA 100 164GB PCI device listing Bus No Device No Func No Yendor Device Class Device Class IRQ 0 2 0 8086 2772 0300 Display Cntrlr 10 0 29 i 8086 2708 98CO3 USB 1 0 1 1 UHCI Cntrir 15 0 29 1 8086 2709 C03 USB 1 0 1 1 UHCI Cntrir 15 0 29 2 8086 27CA C03 USB 1 0 1 1 UHCI Cntrir 5 0 29 3 8086 27CB 0C03 USB 1 0 1 1 UHCI Cntrir 10 0 31 1 8086 27DF 8101 IDE CntrirCI Cntrir 14 i 31 2 8086 2708 6101 IDE Cntrir 15 0 31 3 8086 27DA COS SMBus Cntrlr 15 1 0 i 8086 109A 08200 Network Cntrir 10 2 i 0 8086 109A 0200 Network Cntrlr 11 3 0 i 8086 109A 8200 Network Cntrir 5 4 0 5 8086 109A 0200 Network Cntrlr 15 5 i 8 8086 109A 08200 Network Cntrlr 10 6 0 0 8086 109A 0200 Network Cntrir 11 7 12 i 8086 10
22. it into the appliance To install a replacement power supply 1 Insert the power supply or placeholder unit into the power supply slot 2 Push the power supply or placeholder unit until the release lever clicks 3 Insert the power cord into the power supply socket Make sure that the green LED is illuminated Replacing Expansion Line Cards This section presents the procedures for removing and installing an expansion line card unit There are two types of expansion cards that can be installed Ethernet or Fiber Optic ports A Important Make certain that you are electromagnetically grounded when performing the following procedures Static electricity can damage the appliance Customer Replaceable Parts Page 30 Replacing Expansion Line Cards Check Point 12200 Appliance The built in Ethernet ports ETH1 ETH7 are not customer replaceable Removing Expansion Line Cards To remove an expansion line card 1 ar wh Power off the appliance and remove the power cords from the power supply units Loosen the retaining screws on the expansion line card Holding the screws pull the expansion line card out of the expansion slot Place the metal cover over the expansion slot Tighten the screws on the metal cover Installing Expansion Line Cards To install an expansion line card gt ONS ORIN er Power off the appliance and remove the power cords from the power supply units Loosen the retaining screws on the
23. ity policy requires you to install the SmartConsole applications In the Download SmartConsole Applications window you can download SmartConsole and install it on Windows machines The release notes of your Check Point version in the Check Point Support Center http supportcenter checkpoint com lists compatible Windows operating systems for SmartConsole Centrally Managed Deployment This section describes how to configure the appliance for centrally managed deployment Gateway Type Configure the gateway type for a Centrally Managed appliance Choose one of e Standard Gateway e This Gateway is a member of a cluster e This Gateway uses a dynamically assigned IP Web SSH and GUI Clients Configuration Define the clients that are allowed to connect to the appliance using a web browser or SSH client These clients can manage the appliance using a web or SSH connection You can define a Host according to Hostname or IP address Enter a comma separated list of IP addresses from which you manage the appliance Enter Any to manage the appliance from anywhere Configuring Check Point 12000 Appliances Page 21 Creating the Network Object amp Note Do not use the Any value for security reasons After you complete the First Time Configuration Wizard more options are available using the WebUI menu SIC Setup Configure the SIC Secure Internal Communication settings for a Centrally Managed appliance Enter a SIC Activation Key The s
24. ly Managed Deployment The appliance is a Security Gateway and a Security Management server The Security Management server manages the Security Policy that is enforced by the Security Gateway e Centrally Managed Deployment The appliance is a Security Gateway without a Security Management server The Security Gateway is managed by a remote Security Management server Locally Managed Deployment This section describes how to configure the appliance for locally managed deployment Check Point 12000 Appliances Cluster Configure the cluster type If you select This appliance is part of a Check Point 12000 Appliances Cluster the options are e Primary cluster member e Secondary cluster member For information about clusters see the ClusterXL Administration Guide http supportcenter checkpoint com for your Check Point version Web SSH and GUI Clients Configuration Define the clients that are allowed to connect to the appliance using a web browser or SSH client These clients can manage the appliance using a web or SSH connection You can define a Host according to Hostname or IP address Enter a comma separated list of IP addresses from which you manage the appliance Enter Any to manage the appliance from anywhere Q5 Note Do not use the Any value for security reasons After you complete the First Time Configuration Wizard more options are available using the WebUI menu Download SmartConsole Applications Configuring a secur
25. nections page First Time Configuration Wizard Network Connections V Y Back Next Quit Note that in case the default IP address is changed a secondary IP address is created to preserve the current connection To edit connection properties click on the connection link Network Connections new 7 J J Jl J Name gt Type Member Of IP Address Netmask Status Details ethi Ethernet disabled eth2 Ethernet disabled eth3 Ethernet disabled eth4 Ethernet disabled eths Ethernet disabled eth Ethernet disabled eth Ethernet disabled Mgmt Ethernet 192 168 1 1 255 255 255 0 up You can modify the Management IP address and connectivity is preserved A secondary interface is created automatically to preserve connectivity This interface can be removed after the wizard is completed in the Network gt Network Connections page after the wizard is completed Routing Table Configure the routing settings on the Routing Table page Host Domain Settings and DNS Servers Set the Host Domain and DNS Servers in the Host Domain Settings and DNS Servers page The host name must start with a letter and cannot be named com1 com2 com9 In the DNS section set the DNS servers for the appliance Configuring Check Point 12000 Appliances Page 20 Using the First Time Configuration Wizard Management Type Set how the appliance is managed in the Management Type page e Local
26. ng Page 14 Rack Mounting Check Point 12400 and 12600 Rack Mounting Check Point 12400 and 12600 Attaching the Ear Mount Brackets to the Appliance Attach the two ear mount brackets to the front of the appliance To attach the ear mount brackets to the appliance 1 Attach the appliance ear bracket to one side of the appliance using three ear mount screws 2 Do step 1 again for the other side of the appliance Attaching the Rail Plates Attach the rail plates to the appliance rails to attach the appliance to the rear vertical rails of the rack Item Description 1 Appliance rail 2 Rail plates Rack Mounting Page 15 Rack Mounting Check Point 12400 and 12600 To attach the rail plates 1 Attach a rail plate to an appliance rail using four appliance rail screws 2 Do step 1 again for the other rail plate and appliance rail This figure shows the assembled rail plate and appliance rail Attaching the Appliance Rails to the Appliance Attach the appliance rails to the sides of the appliance The rail plates are positioned to connect the appliance rails to the rear of the rack To attach the appliance rails 1 Set the appliance rail on the side of the appliance The ridges on the appliance rails point to the appliance This diagram shows the appliance rail and rail plate positioned correctly SS A SS SS SS S S SS 2 Attach the appliance rails to the appliance usin
27. o user The user s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In cases where the manual is provided only in a form other than paper such as on a computer disk or over the Internet the information required by this section may be included in the manual in that alternative form provided the user can reasonably be expected to have the capability to access information in that form Safety Environmental and Electronic Emissions Notices Page 5 Welcome Canadian Department Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Japan Compliance Statement Class A CORES FIAAMBRRAARTT CORBERERATERT SECRRBEESFRCTFCEVSEVET COBSCREREY ADS MRMERBFSELIBRENSCEVSHVET VCCI A Class B COMMS FIABHBRARRTT CORE RERE TEA FECCEBDOCULTWETHM CORB IV APT LEV ay RRR TIE TRARENSL SERRE ECO TCEVMSVET MURR AAR IK TES TIED RW RU ELT FSU VCCI B European Union EU Electromagnetic Compatibility Directive This product is herewith confirmed to comply with the requirements se
28. on Line Card Options Expansion line cards can have two four or eight ports These types of expansion line cards are available Model Description CPAC 2 10F 2 Port 10GBase F SFP without transceivers CPAC 4 1C 4 Port 10 100 1000Base T RJ 45 CPAC 4 1F 4 Port 1000Base F SFP without transceivers CPAC 4 10F 4 Port 10GBase F Ethernet PCl e SFP CPAC 8 1C 8 Port 10 100 1000Base T RJ 45 Check Point 12000 Appliances Hardware Page 26 Rear Panel Components Rear Panel Components This section describes the hardware on the rear panel of the appliance Check Point 12200 Rear Panel Item Component Description 1 Power supply unit If a power supply fails or is not connected to the outlet an alarm sounds continuously 2 Power supply For appliances that are provisioned with one power supply unit placeholder unit the placeholder unit is used in the other power supply slot If both power supply slots are not populated a continuous alarm sounds 3 Main power switch 4 Hard disk drives When monitoring the disks using the raid diagnostic command DiskID 0 is the top disk and DiskID 1 isthe bottom disk Check Point 12400 and 12600 Rear Panel Item Component Description 1 Main power switch 2 Power supply units If a power supply fails or is not connected to the outlet an alarm sounds continuously Check Point 12000 Appliances Hardware Page 27 Using the LCD Panel Using the LCD Panel The appliance has an LCD panel th
29. onal improvements stability fixes security enhancements and protection against new and evolving attacks Latest Documentation The latest version of this document is at http supportcontent checkpoint com documentation_download ID 12687 For additional technical information visit the Check Point Support Center http supportcenter checkpoint com Revision History Date Description 31 October 2011 Updated Flow Control settings in Connecting to the CLI on page 22 and Restoring Using the Console Boot Menu 15 August 2011 First release of this document Feedback Check Point is engaged in a continuous effort to improve its documentation Please help us by sending your comments mailto cp_techpub_feedback checkpoint com subject Feedback on Check Point 12000 Appliances Getting Started Guide Welcome Safety Environmental and Electronic Emissions Notices Read the following warnings before setting up or using the appliance A Warning Do not block air vents A minimum 1 2 inch clearance is required A Warning This appliance does not contain any user serviceable parts Do not remove any covers or attempt to gain access to the inside of the product Opening the device or modifying it in any way has the risk of personal injury and will void your warranty The following instructions are for trained service personnel only To prevent damage to any system board it is important to handle it with care The following measures
30. onfiguring Check Point 12000 Appliance ccccccesseeeseeeeeeeeeeeseeeeeneeeeeeeeees 18 POWOMING OM ae nc ceet tie E Wnetag aa alee ecto ts as etic te 18 Using the First Time Configuration Wizard ccccccceeeeeeeeeeneeeeeeeeeeeeeeennneeeeeeees 19 Starting the First Time Configuration Wizard ccceeeeeeeeeeeeteeeeeeeeeeeeeee 19 WY GIG OIG oti eres cetedirr adapt a r E E aE E EAE EATE 20 Appliance Date and Time Setup 00 eeeececcccceeeeeeeeeeneeeaeeeeeeeeeeetenesaaaeeeeeees 20 Network ConnectionS ssssesseneeeereererrttrrnttterrrttrrnnnttsorrttttrnnresrrerenenn ertene 20 Routing Table se ee ae Ae aura ee ee can ence ea ee 20 Host Domain Settings and DNS ServerS ccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 20 Manhagement Type tact ssn ett Ste cet cae ndaehe Stes Seay deee see et nese Amare See cee a e 21 SUMMA ach Spec cis n e eho at areata Gast ahi Rta hae nae Ceuta ais aed ale ME 22 Creating the Network ObjeCt ceeeecceecceeeeeeeeeeeeeaeeeeeeeeeeeteaaaaaaeeeeeeeeeeenesaaaaes 22 Advanced Configuration ccccccccceeeee eeeeeeeeeeeeeeesecaaeaeeeeeeeeteeensaaaeeeeeeeeeneneas 22 Connecting to the CLI sci h an cis tei ei ats eer aanere ashe eaceee 22 Check Point 12000 Appliances Hardware eccccccessseseseeeeeeeeeeeeseeeeeeeneeeeeees 23 Front Panel Components creenanchis a aeei eta ait 23 Check Point 12200 Front Panel cic2 scscsteticcdeaei agli seh levine etac
31. ot operate the processor without a thermal solution Damage to the processor can occur in seconds Class 1 Laser Product Warning Rack Mount Instructions The following or similar rack mount instructions are included with the installation instructions T Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Safety Environmental and Electronic Emissions Notices Page 4 Welcome 4 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern 5 Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections oth
32. power supply immediately and connect the new unit to an A C outlet Replacing Power Supplies on page 29 18 19 22 22 Page 18 Using the First Time Configuration Wizard 3 Wait for the appliance to initialize and boot The status of the appliance appears on the LCD screen Appliance initializing a Please wait a D OY Check Point ja G ons K OY The appliance is ready to use when the model number is displayed Using the First Time Configuration Wizard Perform the initial configuration of Check Point 12000 Appliances using the First Time Configuration Wizard You can use the following commands at any time Click Quit to exit Click Next to move to the next page of the wizard Q Note When running the First Time Configuration Wizard you may not see all the windows that are described in this guide The windows that appear in the wizard depend on the Check Point 12000 Appliances software image and the selections that you make Starting the First Time Configuration Wizard To start the First Time Configuration Wizard 1 Connect a standard network cable to the appliance s management interface and to your management network The management interface is marked MGMT This interface is preconfigured with the IP address 192 168 1 1 Connect to the management interface from a computer on the same network subnet as the management interface For example IP address 192 168 1 x and net mask 255 255 2
33. provide your business with the most up to date and secure solutions available today Check Point also delivers worldwide technical services including educational professional and support services through a network of Authorized Training Centers Certified Support Partners and Check Point technical support personnel to ensure that you get the most out of your security investment For additional information on the Internet Security Product Suite and other security solutions refer to the Check Point Web site http www checkpoint com For additional technical information about Check Point products consult the Check Point Support Center http supportcenter checkpoint com Welcome to the Check Point family We look forward to meeting all of your current and future network application and management security needs Check Point 12000 Appliances Overview The family of Check Point 12000 Appliances enables organizations to maximize security in high performance environments such as large campuses or data centers Combining integrated firewall IPSec VPN and intrusion prevention with advanced acceleration technologies Check Point 12000 Appliances deliver a high performance security platform capable of blocking application layer threats Even as new threats appear Check Point 12000 Appliances maintain or increase performance while protecting the network against attacks Key Features e Proven enterprise class firewall VPN and intrusion preven
34. ptional 2 Located at rear of Located at front of Located at front of appliance appliance appliance Unless directed to do so by Check Point technical support customers are prohibited by warranty and support agreements from replacing any parts Customers are prohibited from opening the appliance case under any circumstances Replacing Power Supplies Check Point 12000 Appliances have a redundant power supply This section explains how to remove and install a power supply or placeholder unit Ss Note If both power supply slots are not populated a continuous alarm sounds Item Description 1 Power switch Customer Replaceable Parts Page 29 Replacing Expansion Line Cards Item Description 2 Power cord socket 3 Release lever 4 Extraction handle 5 Power supply unit Removing Power Supplies This section describes how to remove a power supply or placeholder unit from the appliance To remove a power supply unit 1 Ifthe alarm sounds press the red alarm button to the right of the power supply The alarm stops 2 Remove the power cord from the power supply unit Engage and hold the release lever on the power supply or placeholder unit 4 Pull the extraction handle to remove the power supply or placeholder unit w S Note Remove the power supply unit with the extraction handle to prevent any possible damage Installing Power Supplies This section describes how to install a power supply or placeholder un
35. radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense For a Class B digital device or peripheral NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Information t
36. t out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive 2004 108 EC For the evaluation regarding the Electromagnetic Compatibility 2004 108 EC This product is in conformity with Low Voltage Directive 2006 95 EC and complies with the requirements in the Council Directive 2006 95 EC relating to electrical equipment designed for use within certain voltage limits and the Amendment Directive 93 68 EEC Product Disposal This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office or your household waste disposal service Safety Environmental and Electronic Emissions Notices Page 6 Contents Important Information siai oetkaticascke se ceeciacties eee ecclesia eee eects 3 Safety Environmental and Electronic Emissions Notices cccccccccceeeees 4 DENENOGI CUNO ra rr rre
37. the toolkit unlock the drive 2 Slide the release latch toward the left The extraction handle pops out 3 Using the extraction handle remove the drive from the slot Installing a Hard Disk Drive To install a hard disk drive in a Check Point 12400 or 12600 1 Slide the replacement hard disk drive into the slot 2 Push the extraction handle until it closes and the drive clicks into place 3 Using the key supplied in the toolkit lock the new drive Customer Replaceable Parts Page 33 Chapter 5 Restoring Factory Defaults Part of troubleshooting can be to restore the appliance to its factory default settings To restore your appliance use one of these e WebUl e Console boot menu e LCD panel A Important Restoring factory defaults deletes all information on the appliance In This Chapter Restoring Using the WebUI 34 Restoring Using the Console Boot Menu 34 Restoring Using the LCD Panel 35 Restoring Using the WebUI To restore the appliance to its default factory configuration using the WebUI 1 In a Web browser navigate to https lt appliance ip address gt 4434 2 Log into the WebUI of the appliance using your administrator username and password 3 Inthe WebuUI click Appliance gt Image Management The Image Management window opens 4 Select the relevant image version you wish to revert to 5 Click Revert Restoring Using the Console Boot Menu To restore the appliance to its default factory configurat
38. tion e Accelerated security performance including SecureXL and CoreXL technologies e Integrated load balancing and dynamic routing for data center reliability levels e Centrally managed from Security Management Server Check Point 12000 Appliances or as a stand alone device e Automatic security protection updates from Check Point This document provides e A brief overview of essential Check Point 12000 Appliances concepts and features e A step by step guide to getting Check Point 12000 Appliances up and running Page 9 Shipping Carton Contents Ss Note Screenshots in this guide may apply only to the highest model to which this guide applies Shipping Carton Contents This section describes the contents of the shipping carton Item Description Appliance Check Point 12000 appliance Rack Mounting Accessories Hardware mounting kit Cables e Power cable 12200 appliance e 2 Power cables 12400 and 12600 appliances e 1 Standard RJ 45 network cable e 1 Serial console cable Documentation e Quick Start Guide e Getting Started Guide e Image Management Guide e User license agreement Terminology The following terms are used in this guide Gateway The security engine that enforces the organization s security policy and acts as a security enforcement point Security Policy The policy created by the system administrator that regulates the flow of incoming and outgoing communication Security Management Server
39. upport 37 Where To From Here 37 Registration The appliance requires a product specific Check Point license Get a license and register at the Check Point Appliance Registration site http register checkpoint com cpapp Support For additional technical information about Check Point products consult the Check Point Support Center http supportcenter checkpoint com Where To From Here You have now learned the basics that you need to get started The next step is to obtain more advanced knowledge of your Check Point software Check Point documentation is available on the Check Point Support Center http supportcenter checkpoint com Be sure to also use the Online Help when you are working with the Check Point SmartConsole clients Page 37 Appendix A Compliance Information This appendix contains declaration of conformity compliance and related regulatory information In This Appendix Declaration of Conformity 38 Declaration of Conformity Manufacturer s Name Manufacturer s Address Check Point Software Technologies Ltd 5 Ha Solelim Street Tel Aviv 67897 Israel Declare that under our sole responsibility the products Model Number Product Options All Date First Applied July 2011 P 210 P 220 and P 230 Conforms to the following product specifications EMC FCC 47 CFR Part 15 Class A Information Technology Equipment Radio Disturbance Characteristics VC