1. SINLINE series UPS Instruction Manual TECHNICAL PARAMETERS Rack Model PARAMETERS SINLINE 1200 SINLINE 1600 SINLINE 2000 SINLINE 3000 UPS TYPE Rack Rack Rack Rack 1 1200VA 1600VA 2000VA 3000VA Output power 780W 1040W 1350W 1950W Working environment Office or industrial rooms with low level of pollution Operating temperature 10 35 Storage temperature 0 45 Relative humidity for operation 20 80 without condensation Relative humidity for storage 20 95 without condensation Altitude above sea level 3 up to 1000 m Maximum length of outgoing cables lt 10m MAINS OPERATION MODE Input voltage 160 264 V 145 280 V 2 45 55 Hz 4 1 Hz Freguency of input voltage Range of output voltage 184 264 V 167 280 V 2 Switching thresholds Mains ups 160 V 264 V 145V 280 V 2 Shape of output voltage Sinus Filtering of output voltage Noise filter RFI EMI varistor damper Time to switch to UPS lt 3 ms BATTERY MODULE BATTERY OPERATION MODE Output voltage effective value 230 V 15 Shape of output voltage Sinus Switching thresholds ups mains 165 V 259 V 150 V 275 V 2 Frequency of output voltage 50 Hz 1 Hz Filtering of output voltage LC Shorting safeguard Electronic
2. Charging Discharging 14 5v 12 0V 13 5V 11 5V O 12 5V 11 0V O 12 0V 10 5V 2 Power switch 3 LED indicating whether the AVR Automatic Voltage Regulation system is active 4 Two colour LED indicating the operation mode a Mains operation mode constant green light b Battery module operation mode constant yellow light 5 A column of LEDs three green top one red indicating the percentage load of the UPS The top red LED indicates that the BACK UP Sload exceeds the recommended nominal power level 2010 01 26 www ever eu 5 SINLINE series UPS Instruction Manual If only the red LED is lit and blinking quickly with acoustic signal it indicates the occurrence of a short circuit at the BACK UP Soutput If only the red LED is lit with acoustic signal it indicates that the battery module has overloaded O gt 85 O 260 230 O gt 5 REAR PANEL Fig 2 Rear panel 6 Outlet sockets 7 RS232 serial port for communication with a PC 8 Telecommunications filter sockets 9 Power cord 0 Circuit breaker fuse in battery modules with power of BOOVA 1200VA and 1600VA circuit breaker in battery modules with power of 2000VA and 3000VA 2010 01 26 www ever eu 6 SINLINE series UPS Instruction Manual ELEMENTS OF THE SINLINE UPS Rack Model FRONT PANEL O sag Fig 3 SINLINE RACK 19 2U and 3U Front Pa
3. EVER POWER SYSTEMS INSTRUCTION MANUAL SINLINE SINLINE RACK 2U i 3U EVER Sp z 0 0 ul Grudzi skiego 30 62 020 Swarz dz Poland www ever eu upsQever com pl tel 0048 61 6500 400 fax 0048 61 6510 927 SINLINE series UPS Instruction Manual TABLE OF CONTENTS TABLE OFCON TENN SE GE Ee AO tee E ea O YA CE Se AUS RN ORAL C 2 INTRODUCTION GE ae ete Ses caterer ak Ae Se eh Oe ala A ct E eS 3 GENERAL INFORMATION ec ee cee ty i OO Slt eee a ee ete oy Pe Gn hs ip ea as hes 3 PURPOSE OF THE POWERSUPPLY SES ge ei Bele een eS ee ye es 3 GENERAL FEATURES OF THE UPS A668 oi ieee ite ba dle ea i ees 4 ELEMENTS OF THE SINLINE UPS TOWER MODEL see se ee se ee se ee se ee ee ese ee ee ge ee ke ee ee ee ee ee ee ee ee se ee 5 ERONT PANEL tea Ee Re edd eat os eter RE GE RE ete ie ca ee Og 5 REAR PANEL HE OES os sees eget eg leit O A a See Bhs a Se OR ae a ans Co LPA 6 ELEMENTS OF THE SINLINE UPS RACK MODEL ese see se ee se ee se ee se ee se ee se ee se ese ee ee ge ee ke ee ee ee ee ee ee ee ee se ee 7 FRONT PANEL RE EER HE EE OR OR EE EE KERE EE N 7 REAR PANEL e EER ER N ER OER ER EE EE AE ER AE 8 HEALTH AND SAFETY INSTRUCTIONS ee esse esse se se ese ee ee ese ee ee ee ee ee ee ee ee ee se ee se ee ee aaa aaa ke Se ke ee ke eed Gee ee ee 8 HANDEING ER RE EE ER EE RE Aida W O OE ER OE ERG 8 ELECTRIC SAFETY AE TEE EE OE b OR ORE EE KERE EE EE NG 9 INSTALLATION ER EE ER OR RO OOR EE OE OR EE O
4. 10 Telecommunications filter sockets HEALTH AND SAFETY INSTRUCTIONS HANDLING e exercise utmost caution when handling the device e do not handle heavy equipment by yourself lt 18 kg 33 55 kg 18 32 kg a gt 55 kg e storage and operation of the device should take place in conditions conforming to its specification 2010 01 26 www ever eu 8 SINLINE series UPS Instruction Manual ELECTRIC SAFETY Never work alone in conditions that may be hazardous to health and or life Even a momentary shorting of a strong current may lead to severe burns Prior to connecting the device to the mains inspect the condition of power cords plugs and sockets as well as the condition of the device itself To minimise the risk of electric shock in cases when there is no way of verifying the earthing the device should be disconnected from the mains before installation or connection of other equipment to the battery module reconnect the power cord only after all connections are made To avoid the risk of electric shock when connecting and disconnecting signal cables and touching two surfaces with differing electric potential if possible use only one hand The device must be plugged in to a 3 lead socket two poles and earthing connecting the device to any other socket may result in electric shock The device receiving the current must be connected with an appropriate circuit protection manual circuit breaker or
5. 150 V 275 V 2 Frequency of output voltage 50 Hz 4 1 Hz Filtering of output voltage LC Shorting protection Electronic Overload protection Electronic Time to switch back to mains operation 0 ms Support time 100 80 50 P max 5 7 12 min 4 5 6 10 min 4 5 8 min 4 5 9 min 3 4 8 min Battery 2X5 Ah 2X7 Ah 3X5 Ah 4X5 Ah 4X7 Ah Maximum charging time 5h 7h 5h 5h 7h MECHANICAL PARAMETERS Dimensions h x w x d in mm 190 x 165 x 480 Li SA Weight 14 kg 16 kg 20 kg 23 kg 28 kg EQUIPMENT Number of outlet sockets 4 Signalling Acoustic and visual LEDs Circuit breaker Fuse 5x20mm 10 A Circuit breaker 15 A Telecommunications filter Available Communication interface RS 232 Note The manufacturer reserves the right to change the abovementioned parameters without prior notice Notes 1 For normal operation of the UPS the load connected to its output should not exceed 80 of value indicated in the table Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load current decreases The user change the switching provided in parentheses Continued exposure of the UPS to the temperature of the surrounding exceeding 25 will shorten the life of batteries If the altitude above sea level increases beyond the provided limit the permitted load power of the batter battery module thresholds by setting standard or enhanced thresholds respectively 2010 01 26 WWW ever eu 25
6. output thanks to the Clear Digital Sinus CDS system and offer the feature of remote control of operating parameters via RS232 serial port Sinline series UPS were designed to meet all your expectations in terms of protection against power loss The UPSs were manufactured in Poland and their structure conforms with requirements of the CE symbol GENERAL INFORMATION PURPOSE OF THE POWER SUPPLY SINLINE series UPSs are LINE INTERACTIVE class devices designed to work with equipment powered by monophase 230V mains In battery module operation mode they generate true sine wave voltage at their output This enables a much wider range of tolerated loads when compared with power supply devices using approximation of the sinusoid UPSs belonging to this group may power virtually any device whose power does not exceed the nominal power of the UPS SINLINE UPSs do not switch off automatically even when there are no devices connected to the outlet sockets so they may even power devices with extremely low power consumption Load power of these UPSs is limited only at the upper extreme and the overload status is communicated visually acoustically and via the PC software monitoring the device Unlike quasi sine wave UPSs the SINLINE series battery modules may power devices with induction motors l WARNING SINLINE UPSs were not designed to work with medical equipment in particular life and or health support devices 2010 01 26 ww
7. 26 www ever eu 13 SINLINE series UPS Instruction Manual Output installation Even though the input side allows both types of terminals the output installation arranged inconsistently with this instruction may damage the UPS The diagram of correctly arranged output connections is presented on the scheme below A WARNING The output side of the battery module only allows the TN S mains configuration i L ups L sg 5 i n5 5 2N 2 ZIN N e z 5 Y PE PE OPE 3 PE 5 z TN S l LOAD CORRECT POWER SUPPLY INCORRECT Fig 9 Output installation of a Tower model Sinline UPS The arrangement of terminals of output sockets of Tower and Rack model Sinline UPS is presented on figures 10 and 11 below Fig 10 The arrangement of terminals of output sockets of Tower model Sinline battery module 2010 01 26 www ever eu 14 SINLINE series UPS Instruction Manual Fig 11 The arrangement of terminals of output sockets of Rack Model Sinline battery module FIRST START WARNING The UPS may only be connected to a 230V mains N socket equipped with a grounding bolt Electric installation of the building to which the battery module is connected must be protected against overloads and shorting After unpacking place the device in the chosen locati
8. The batteries should be removed from the appliance by an authorised service outlet or by a duly authorised electrician 2010 01 26 www ever eu 24 SINLINE series UPS Instruction Manual TECHNICAL PARAMETERS Tower Model PARAMETERS SINLINE SINLINE SINLINE SINLINE SINLINE UPS TYPE 800 1200 1600 2000 3000 1 800VA 1200VA 1600VA 2000VA 3000VA Output power 520W 780W 1040W 1300W 1950W Working environment Office or industrial rooms with low level of pollution Operating temperature 10 35 Storage temperature 0 45 Relative humidity for operation 20 80 without condensation Relative humidity for storage 20 95 without condensation Altitude above sea level up to 1000 m Maximum length of outgoing cables lt 10m MAINS OPERATION MODE Input voltage 160 264 V 145 280 V 2 Frequency of input voltage 45 55 Hz 1 Hz Range of output voltage 184 264 V 167 280 V 2 Switching thresholds mains UPS 160 V 264 V 145V 280 V 2 Shape of output voltage Sinus Filtering of output voltage Noise filter RFI EMI varistor damper Time to switch to UPS lt 3 ms BATTERY MODULE BATTERY OPERATION MODE Output voltage effective value 230 V 15 Shape of output voltage Sinus Switching thresholds UPS mains 3 165 V 259 V
9. also provides advanced methods of communication between the UPS and the computer via the RS232 port The DPC system provides precise measurements of such basic parameters of the UPS as battery voltage mains frequency and input voltage voltage and output current of the battery module the power of load connected 2010 01 26 www ever eu 16 SINLINE series UPS Instruction Manual This UPS utilises an innovative charging method reserved only for the most advanced UPSs CBC COOL BATTERY CHARGING During the mains operation mode it charges the batteries and in the battery module operation mode it converts the internal energy of the battery into the alternating current to power the protected devices MAINS OPERATION MODE Turning the UPS on with the switch on the front panel is signalled by momentary lighting up of all LEDs located on the front panel and then by alternate blinking of the green yellow or green red in the Rack model operation mode LED The lighting up of LEDs is accompanied by an acoustic signal After the initialisation process the UPS will attempt synchronisation with the mains If the mains voltage of the socket to which the BACK UP Spower cord is connected is appropriate then after approximately 10 seconds the UPS switches to the mains operation mode and lights the green operation mode LED If the mains voltage is incorrect too low or too high voltage or frequency exceeding the operation range the UPS switch
10. levels conform with the device s specification In order to ensure correct operation of the battery module appropriate cooling conditions for the device must be provided For this reason the ventilation openings on the BACK UP Scase must be uncovered The battery module is designed for installation in a cabinet rack To facilitate installation in cabinets racks of various depth the device is equipped with moving handles which enable installation in racks with depth of up to 600 mm If the battery module is to be installed in a rack of 800 mm or 1000 mm depth it is possible to order longer handles to adjust the product for installation in such a rack To install the UPS take the following steps 1 Remove the handles marked as 1 by sliding them out of the rear part of the sides of the UPS Install the battery module by screwing the front brackets 2 to the rack s frame Supporting the BACK UP Sbase with hand slide the handles 1 into the rear part of the BACK UP Ssides 4 Move the handles 1 to the rack s frame and screw them down 2010 01 26 www ever eu 11 SINLINE series UPS Instruction Manual Fig 6 SINLINE RACK 19 Top View N WARNING The device must not be installed in the proximity of flammable materials CONNECTIONS The mains socket the UPS is to be connected to should be located near the battery module maximum distance 1 5 m and should be easily accessible Do not use addi
11. BE niacin Bee ON ERG Ek ge OO Sates EO RIES yy Ad 23 USING THE TELECOMMUNICATIONS FILTER sesse sees se es se ee se esse ese ee see ee ee ee ee ee ee ere ee se Ge ee ee ee ee 23 STORAGE MAINTENANCE AND TRANSPORT cece sees se esse esse ese ese see see ee ee ee ee eke Gee Gee be ee ee ee see 24 FUSE REPLACEMENT SINLINE Tower UPSS iese esse se see see see ee ee ee ee ee ee ee ee ee ee se ee see ese ese ke ese ee ge ee ge ee ke ee ee a 24 DISPOSAT ER ER OE RE ER AE ER OE ER OE EE OT 24 TECHNICAL PARAMETERS TOWER MODEL esse se se se ee eee ee ee ee ee ee eek ee ee ee ee ee ee ee see ee ee ke ee ke ee ke eed ee 25 TECHNICAL PARAMETERS RACK MODEL ees see ese se see ee ee ee ee ee ee ee ee ee ee se ee se ee se ese see ee EEE E ee ke E ee 26 INFORMATION REGARDING REGULATIONS AND WARRANTY uo sees se esse ese ese ee se ese ee se ke ee ee 27 DECLARATION OF CONFORMITY Es ese sings Be gee Ge RE gee ee O Gd sag E Dag Ee Ee Rek ER Re see sb seg ieee 27 WARRANT Vices ee POCOO sania RE ve E ee AE Re ee ED Ee EE Ke Le ee EE ED Gee E 27 2010 01 26 www ever eu 2 SINLINE series UPS Instruction Manual INTRODUCTION Thank you for purchasing the EVER SINLINE UPS UPS It belongs to the latest series of state of the art power supply devices designed to work with servers small computer networks as well as Tower and Rack type workstations When operating in the battery mode the UPSs of this series generate sinusoidal current at their
12. Overload protection Electronic Time to switch back to mains operation 0 ms Support time 100 80 50 P max 4 5 6 10 min 4 5 8 min 4 5 9 min 3 4 8 min Battery 2x7Ah 3x5 Ah 4x5 Ah 4x7 Ah Maximum charging time 7h 5h 5h 7h MECHANICAL PARAMETERS Dimensions 2U x 19 x 320 3U x 19 x 400 3U x 19 x 400 3U x 19 x 400 Weight 20 kg 25 kg 32 5 kg 35 kg EQUIPMENT Number of outlet sockets 6 x IEC320 C13 Signalling Acoustic and visual LEDs Circuit breaker 10A 10A 15A 15A Communication interface RS 232 Note The manufacturer reserves the right to change the abovementioned parameters without notice Notes 1 For normal operation of the UPS the load connected to its output should not exceed 80 of value indicated in the table Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load current Continued exposure of the UPS to the temperature of the surrounding exceeding 25 will shorten the life of batteries If the altitude above sea level increases beyond the provided limit the permitted load power of the batter battery module decreases The user may change the switching thresholds by setting standard or enhanced thresholds respectively provided in parentheses 2010 01 26 www ever eu 26 SINLINE series UPS Instruction Manual INFORMATION REGARDING REGULATIONS AND WARRANTY DECLARATION OF CONFORMITY The UPS was manuf
13. R 10 UNPACKING RE OR EE EE OO ER N ER HE ERA 10 INSTALLATION OF THE SINLINE UPS Tower Model se se see see se ee se ee se ee se esse ese ee see ee ke ee ke ee 10 INSTALLATION OF THE SINLINE UPS Rack Model sees see ses sees se ee se ee se esse ese ee ese ee Gee ee ke ee ee 11 CONNECTIONS OR EE ches Sua EE ER OON RE OOR EE OR 12 FURS TS TAR RR EE EE EO EE RE EE EE SE EE EE 15 DESCRIPTION OF THE UPS SOPERATION SESSE EG Se ee ei GS ee Ge Ee Ge SE Ee gee ee aioe 16 GENERAL INEORMATION EE See ee ES Se AO O GEO ED bee ee date enon RAAL 16 MAINS OPERATIONMODE SE EE er O Ge ee Dee OE GS ek Ge Gas Ena ata RS 17 BATTERY MODULE BATTERY OPERATION MODE see sees see se ee se ee se ee se ee se ee se ese ee ee ge ee ke ee ee ee ee 17 dee AS AE EE ER EE OE N R HE A ORA N 18 COMMUNICATION BETWEEN THE UPS AND THE COMPUTER sesse esse esse esse ese ese ee se ge ee ee ee ee eke sere 19 INSTALLATION AND CONFIGURATION OF THE POWERSOFT PERSONAL SOFTWARE 20 Installation on computers with WindOWS ees esse ese ee ee ee Ge Se GR RA GRA Rd RA Re ee ee ee Se Se Re Se ee RA Ge be 20 Installation on computers with Linux UNIX see se ee ee ee aaa aaa aaa Re Se ee AR Re bee 20 Software Updates m es EA EE EE ee Ee EE ER SE EE GES GE EG sone Ee WE EG GEE ee ERG eG ee EE bene ig 21 CONFIGURING THE UPS S PARAMETERS ee se ese es se es se ee Be see see see sees see ese ee se es se een Be see Bee Be sae see ss 22 ADDITIONAL REMARKS ers io esse R
14. Thres Lower 160 V 145 V 165 V 150 V hold Upper 264 V 280 V 259 V 275 V Voltage tolerance range presented in the table above is 2 These are the rms values of alternate current 2010 01 26 www ever eu 22 SINLINE series UPS Instruction Manual ADDITIONAL REMARKS CAUTION This is a C2 category UPS In domestic environment the A N product may interfere with reception of radio waves so the user may be required to implement additional preventive measures j WARNING No service elements located inside the UPS are to be modified by the end user e Damaging the warranty seal will void the warranty for the given device e Any repairs should be conducted only by qualified technical support staff e The UPS may not perform as expected if the powered equipment draws high impulse power In practice this means that even though mean power of the protected equipment does not exceed the power range accepted by the UPS the equipment will cause the UPS to shut down This happens because the powered equipment temporarily draws power that significantly exceeds the nominal power of the UPS which causes an overload detection and consequently a shutdown This situation may occur in the case of Television sets and monitors as they are switched on the picture tube is degaussed which temporarily requires a lot of power Laser printers drum warming cycle Other products with similar operating featur
15. actured in Poland and its structure conforms to appropriate subject matter standards WARRANTY A separate document attached to the product constitutes the warranty The document must meet all formal requirements e g the following fields must be populated serial number model type date of sale and dealer stamp The manufacturer made all efforts to ensure that products offered are free of material and workmanship defects The company s liability under the warranty shall be limited to repairs or replacement of products with such defects The manufacturer shall make the decision as to how the defect is removed The warranty shall not cover devices with mechanical damages that occurred as a result of negligence of incorrect use nor devices subjected to any modifications made by the user Apart from the arrangements included in the warranty card EVER Sp z o o shall not grant any guarantee or warranty including warranty of merchantability or fitness for particular purpose Apart from the arrangements included in the warranty card EVER Sp z o o shall not be liable for direct indirect specific incidental or consequeniial losses incurred in the course of using the UPS even in cases when the buyer was warned about such losses being a possibility The company shall not be liable for any costs such as loss of profit or revenue cost of equipment costs of equipment use costs of software data replacement products claims of third parties or
16. circuit breaker A device powered via a cord with a plug has an earthing lead that carries away the leakage current from the receivers e g computer equipment the total leakage current must not exceed 3 5mA Users are forbidden to carry out any maintenance activities as they may lead to injury or death Any repairs and replacement of batteries should be conducted only by a qualified representative of the technical support WARNING The UPS is disconnected from the mains only when the power cord is removed from its socket WARNING Since the device is equipped with internal power source N batteries the output may provide current even though the device itself is not connected to the mains 1 WARNING SINLINE and SINLINE RACK UPSs were not designed to work with medical equipment in particular life support devices 2010 01 26 www ever eu 9 SINLINE series UPS Instruction Manual INSTALLATION WARNING Prior to the installation of the UPS it is crucial to A N familiarise yourself with the health amp safety measures provided in the previous chapter UNPACKING Please inspect the UPS upon receipt Although the product is packed very carefully it might have sustained damage from shock during transport Should you find any damages please inform the carrier or dealer immediately A N WARNING The device is delivered with its battery connected C
17. d incorrectly 0000 2 ad pA BR Internal errors a combination of lit LEDs indicates O O 1 S various errors m 0000 1 Information for the tech support COMMUNICATION BETWEEN THE UPS AND THE COMPUTER SINLINE series UPSs come with enhanced control features The UPS is delivered with a built in RS232 communication port and the PowerSoft software package In order to ensure correct cooperation the UPS must be connected to the computer with the provided cable After the cable is connected turn on the battery module start the computer and install the software in accordance with the instruction manual or the instructions provided by the installation software WARNING The communication connection between the UPS and the computer should be made only if the user intends to use the control software If the software is not installed while the connection is made the RS232 port may receive random conditions PNP or others which may lead to incorrect operation of the UPS WARNING The computer controlling the UPS should be powered by N the battery module Otherwise the communication interface may become damaged 2010 01 26 www ever eu 19 SINLINE series UPS Instruction Manual INSTALLATION AND CONFIGURATION OF THE POWERSOFT PERSONAL SOFTWARE Installation on computers with Windows Prior to beginning the installation of PowerSoft e Uninstall the current ver
18. ery output This system increases the reliability of the device and guarantees a stable operation of the UPS The UPS also utilises the system of advanced DIGITAL POWER CONTROL DPC which precisely shapes the oscillation of the output voltage to obtain a clear sinus In the mains operation mode the system filters the mains voltage to remove the noise and distortions that may be dangerous for the load With the help of the Automatic Voltage Regulation AVR system the UPS instantly corrects slight drops in mains voltage to provide the receivers with appropriate power supply conditions without tapping into the energy reserves stored in the batteries In the battery module operation mode the system generates a precisely stabilised output voltage in the shape of sinusoid which enables supplying power to a wide range of equipment that does not tolerate quasi true sine waves The dedicated DPC system monitors the operation of the UPS it has a precise and very quick reacting system of detecting overloads and outlet shorting in the battery module operation mode In the mains operation mode the shorting protection is provided by a circuit breaker while the overload protection provided by the DPC system is as precise as it is in the battery module operation mode When the UPS is launched in the battery module operation mode the DPC system utilises a special soft start mode in order to engage with high loads that draw high starting current The DPC system
19. es Therefore if a UPS is to be used with equipment other than computers its compatibility with equipment used must be verified In order to do this all devices should be connected to the UPS and its operation should be observed in all modes i e start up shutdown stand by etc USING THE TELECOMMUNICATIONS FILTER In order to safeguard the telephone line and connected devices such as modems or telephones the SINLINE UPSs are equipped with an anti overvoltage filter which safeguards the devices connected against overvoltages in the telephone line If the filter is to safeguard the device correctly they must be connected by a cable with RJ11 or RJ12 terminators The existing telephone line should be connected to the other outlet socket of the filter The filter is symmetrical so it does not matter to which of the two sockets the telephone line is connected 2010 01 26 www ever eu 23 SINLINE series UPS Instruction Manual STORAGE MAINTENANCE AND TRANSPORT The UPS should be stored in a cool and dry place in operating position with batteries completely charged In temperatures between OC and 30 the battery should be charged every 6 months In temperatures between 30 and 45 the batter y should be charged every 3 months The UPS should be transported in the original packaging and in conditions conforming to the product s specification see storage conditions If the packaging is missing or a
20. es to the battery module operation mode and lights the yellow operation mode LED or red in the Rack model In the mains operation mode the UPS s outlet provides mains voltage that was filtered or raised by the AVR system BATTERY MODULE BATTERY OPERATION MODE In the battery module operation mode the output true sine wave voltage is generated by the battery until the mains voltage returns or the battery is discharged When operating in the battery module mode if the battery is discharged or the UPS receives an appropriate command from the control software it may switch to the battery stand by mode In case of an overload the UPS lights up the red LED in the load indication column and emits a continuous sound signal In case of a shorting in battery module operation mode the UPS will communicate this by a quick blinking of the red LED in the load indication column together with an intermittent sound signal If the shorting lasts longer than approximately 0 5 second the UPS switches to and remains in the emergency mode until the user switches the device off or until the batteries are discharged 2010 01 26 www ever eu 17 SINLINE series UPS Instruction Manual SAFEGUARDS Against overloads Overload is signalled by constant shining of the last LED red in the load indication column and a continuous sound signal If the UPS is operating in battery module mode then after a short time the overload causes the UPS to switch
21. ged under the Update Configuration tab in the system s program menu 2010 01 26 www ever eu 21 SINLINE series UPS Instruction Manual Linux Unix systems For Linux Unix systems PowerSoft can be updated by downloading the new package from www ever eu For CentOS RedHat Suse Linux and Fedora Core PowerSoft can be updated by entering the following command rom Uv PowerSoftlite x x x For Debian and FreeBSD systems we recommend uninstalling the old version and then installing the new version of the software Commands which enable these operations are described in the instruction manual available at www ever eu CONFIGURING THE UPS S PARAMETERS PowerSoft Plus allows the user to change certain parameters of the UPS To enable this the UPS must be connected to the computer with the cable provided by the manufacturer A list of these parameters together with available settings is presented in the table below Table 2 PARAMETER FUNCTION DEFAULT SETTING USER CHOICE DESCRIPTION Acoustic signalling On On Off Sier ed operation Time between system shutdown Delay before standby mode 90 sec 5 255 sec and the UPS switching to standby mode Pa Switching thresholds when going UPS switching thresholds Standard Standard Enhanced from mains mode to battery mode Table 3 MANE En mes MY ETE Switching from battery to mains mode Standard Enhanced Standard Enhanced
22. heck the contents of the packaging The packaging should contain e the UPS e a CD ROM with the PowerSoft software and complete instruction manual e quick reference guide RS232 communication cable to connect the battery module to a computer e warranty card backup fuse only for Sinline Tower model backups with the power of 800 VA 1200 VA and 1600 VA e 2 moving handles for cabinet installation Rack Model only INSTALLATION OF THE SINLINE UPS Tower Model When choosing the installation location you must take the device s weight into account The battery module should only be used in rooms where dustiness temperature and moisture levels conform with the device s specification To ensure a correct operation of the battery module appropriate cooling conditions for the device must be provided For this reason the ventilation openings on the BACK UP Scase must be uncovered and the distance between the battery module and other objects should be at least 10 cm 1 WARNING The device must not be installed in the proximity of flammable materials 2010 01 26 www ever eu 10 SINLINE series UPS Instruction Manual INSTALLATION OF THE SINLINE UPS Rack Model When choosing the installation spot you must take the device s weight into account Strength of the supporting cabinet rack is the most important The battery module should only be used in rooms where dustiness temperature and moisture
23. l and use the software After installation the application may be found in the usr local PowerSoft directory To uninstall the application enter the following command 2010 01 26 www ever eu 20 SINLINE series UPS Instruction Manual rpm ev PowerSoftpersonal x x x Debian For the Debian systems the software is provided in the form of a DEB package The software is installed with the use of the following command dpkg install PowerSoftpersonal x x x deb To uninstall the application enter the following command dpkg remove PowerSoft FreeBSD For FreeBSD systems the software is provided in the form of the default package format designed for FreeBSD systems The software is installed via the following command pkg_add PowerSoftpersonal x x x tbz To uninstall the application enter the following command pkg_delete PowerSoft Starting the software When the installation is complete the system service is started automatically while the control panel application can be found at usr local PowerSott Please note that for the English diacritics to be correctly displayed the system locale should be English Software Updates Windows systems The software installer for Windows systems has a built in automatic updater PowerSoft can regularly check for new software versions and notify the user when updates are available By default the software checks for updates after user logs in This setting can be chan
24. nel 1 Circuit breaker 2 Power switch 3 Two colour LED indicating the operation mode a Mains operation mode constant green light b Battery module operation mode constant red light 4 LED indicating whether the AVR Automatic Voltage Regulation system is active 5 A line of LEDs three green and one red indicating the percentage load of the UPS The red LED indicates that the BACK UP Sload exceeds the recommended nominal power level If only the red LED is lit and blinking quickly with acoustic signal it indicates the occurrence of a short circuit at the BACK UP Soutput If only the red LED is lit with acoustic signal it indicates that the battery module has overloaded 0 H gt 5 gt 30 gt 60 gt 85 6 The line of green LEDs indicates the charge level of the battery The picture below indicates the thresholds for a single battery at which individual LEDs light up O OOO gt 20 gt 45 gt 80 gt 95 2010 01 26 www ever eu 7 SINLINE series UPS Instruction Manual REAR PANEL E A N D W HER EES ARE A 3 ES KPU 7 7747 17 8 9 10 Fig 4 SINLINE RACK 19 2U Rear Panel EM Po a 7 8 9 ie AN GER y f 7 10 RZ LZA 7 zda Fig 5 SINLINE RACK 19 3U Rear Panel 7 IEC 320 C13 outlet sockets 8 RS232 serial port for communication with a PC 9 Power cord socket 0
25. non original or incomplete packaging is used EVER Sp z o o shall not be liable for any mechanical damages that occur in transport FUSE REPLACEMENT SINLINE Tower UPSs If the power consumption of a device connected to the UPS exceeds its nominal power or if a shorting in a mains socket takes place it may cause the fuse to burn pertains to UPSs with power of 800 VA 1200 VA 1600 VA In order to replace the fuse turn the UPS off with the power switch remove the power cord from the socket remove the fuse holder and replace the fuse with a spare one that conforms to the BACK UP Sspecification The holder contains one spare fuse in addition to the one installed DISPOSAL Appropriate disposal of used up electric and electronic equipment helps to avoid consequences of the presence of dangerous materials as well as inappropriate storage and processing of such equipment which may be hazardous to human life and the environment Act dated 29 July 2005 on used up electric and electronic equipment Article 22 1 items 1 and 2 X o According to the applicable EU regulations a crossed rubbish bin symbol means that when a product is no longer used it should be disposed of at a special waste pickup site This concerns the device itself as well as other accessories marked with this symbol Do not dispose of those products together with unsorted household waste Method of safe removal of the batteries from the appliance
26. on connect it to the mains and turn on the UPS with the switch on the front panel in order to charge the internal batteries Charging time of batteries can be found in the technical parameters table Afterwards the user may continue with the installation procedure Take the following steps e Turn the UPS off switch in the 0 position only if it was turned on e connect the devices that require buffer power supply e g computer and monitor to the outlet sockets on the UPS e connect the UPS to the computer via the RS232 cable e turn on the UPS with the switch on the front panel switch in the 1 position e turn on the devices connected to the UPS e install the monitoring software on the control computer see chapter Installation and configuration of the PowerSoft software With all of the above steps complete the UPS is ready for operation 1 WARNING BACK UP S batteries reach their full capacity after approximately a month of mains operation mode 2010 01 26 www ever eu 15 SINLINE series UPS Instruction Manual DESCRIPTION OF THE UPS S OPERATION GENERAL INFORMATION The SINLINE UPS is a state of the art electronic device constituting an autonomous source of true sine wave voltage of 230V This device belongs to the LINE INTERACTIVE class of uninterruptible power supply devices including the CLEAR DIGITAL SINUS CDS system that generates a clear voltage sinus at the batt
27. other costs 2010 01 26 www ever eu 27
28. sion of PowerSoft or any other control software if the user is changing the UPS protecting the computer e Connect the communication cable if it has not been connected While doing this remember that both the UPS and the computer should be switched off In order to install PowerSoft on a computer with Windows the list of operating systems compatible with the application is available at www ever eu just run the software installer and follow the instructions onscreen During the installation you will be asked to select the model of the UPS connected to the computer on which the software is being installed This setting may also be changed when the application is running To uninstall PowerSoft select the Uninstall PowerSoft option in Start Menu You can also uninstall PowerSoft from the Add and remove programs menu in the control panel Installation on computers with Linux Unix The binary version of the application for Linux Unix systems is provided in the following formats CentOS RedHat Suse Linux Fedora Core For the CentOS RedHat Suse Linux and Fedora Core systems the software is provided in the form of a RPM package The software can be installed by using any package manager available for the system installed If you are using the command line the software is installed by entering the following command rpm ivh PowerSoftpersonal x x x i386 fom Users working with the PowerSoft must have root privileges to instal
29. tional extension cords to connect the device to the mains WARNING The UPS is disconnected from the mains only when the power cord is removed from its socket 2010 01 26 www ever eu 12 SINLINE series UPS Instruction Manual Due to the type and location of circuit breakers in the UPS the safety circuits of the building function as one of the protection measures This is essential to provide the UPS with shorting protection Protection parameters of the buildings installations should be adjusted according to the type and size of load connected to the installation Differing characteristics of protections of installations in the building and the UPS may in extreme cases lead to quicker responses of the former Input installation To connect the UPS in accordance with the instruction manual the layout of terminals of the mains socket is important PE Fig 7 Layout of terminals of a mains socket The figure below presents the correct ways of connecting the UPS to different types of mains TN S or TN C S that vary with regard to the manner of earthing ss L UPS IL a 5 L EA ME F N PEN 5 3 N N ra E O u DE Co PE PE A PE TN S LOAD ia gL UPS L z RE z i im me 2 a E N N D 14 OPE PE 2 PE O a TN C S LOAD Fig 8 Input installation of the UPS 2010 01
30. to emergency operation mode In addition the UPS is equipped with internal safeguards against overloads and shorting of the battery circuit Against shorting In the mains operation mode the safeguard against shorting is provided by the circuit breaker located in the rear section of the UPS If the shorting occurs in the battery operation mode the output current is limited to a safe level This is signalled by a quick blinking of the last LED red in the load indication column and a quick intermittent sound signal If the shorting lasts longer than 0 5 second the UPS switches to the emergency operation mode Against overvoltage Devices connected to the UPS are protected against mains overvoltage This solution protects the receivers against impulse current rushes caused by atmospheric phenomena or power grid disruptions Against incorrect connection Incorrect connection of the UPS causes it to switch to emergency operation mode the moment it is switched on Such an event is signalled by slow blinking of the last LED red in the load indication column and an intermittent sound signal mirroring the rate of blinking In addition the layout of lit LEDs in the battery charge level column indicates the type of error see the Error Table below 2010 01 26 www ever eu 18 SINLINE series UPS Instruction Manual Table 1 ERROR TABLE Signalling Type of error Tower Model Rack Model OOO UPS connecte
31. w ever eu 3 SINLINE series UPS Instruction Manual It is not recommended to use these UPSs to power large TV sets laser printers and other similar devices that draw greater impulse power than the battery module is capable of providing GENERAL FEATURES OF THE UPS e Output true sine wave voltagegenerated in battery module operation mode DPC digital control of operating parameters of the battery module such as shape of the output voltage frequency of the output voltage charge level of batteries Digital monitoring of external parameters such as value of the mains voltage frequency of the mains voltage value of the output voltage value of the output current value of the power connected to the battery modules output e AVR Automatic Voltage Regulation automatic mains voltage regulation system e Filtering of the mains voltage RS232 serial port for communication with a PC PowerSoft software to monitor the operating parameters of the battery module and shut down the system automatically 2010 01 26 www ever eu 4 SINLINE series UPS Instruction Manual ELEMENTS OF THE SINLINE UPS Tower Model FRONT PANEL Fig 1 Front panel 1 A column of green LEDs indicating the charge level of the battery The figure below indicates the voltage thresholds for a single battery at which individual LEDs light up