Home
Eaton ENV1000H uninterruptible power supply (UPS)
Contents
1. Software is not Check the setting of lost between installed well the software UPS and 2 Cable is not properly 2 Check the computer connected RS 232 USB cable is firmly connected with the computer and confirm the setting again Mains normal 1 Circuit breaker is Reset the circuit but the UPS is broken breaker not working 2 Power cord isloose B Reconnect the power cord properly If any abnormal situations occur that are notlisted above please call service people immediately Safety Caution Do not dispose of batteries in a fire as they may explode A battery can presenta risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from atteries When replacing batteries replace with the same number and type of sealed lead acid battery This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operate
2. E I N Powering Business Worldwide User Manual Eaton ENV1000L H Eaton ENV1400H Eaton ENV2000H www eaton com nvups g System Description Front Panel AC Mode Green Lighti Backup Mod Green Flashing Load Level LEDs Backup Mode Battery Capacity LEDs Back Panel gt USB Port optional es Cooling Fan a 9 gt Modem Phone Line ossz am g NEMA 6 J System Description Back Panel E gt E eze hae Modem Phone Line Bl aen Surge Protection oS Is Circuit Breaker lt en ng AC Output am a Se IEC 6 Am a M Modem Phone Line an E gt USB Port optional cam Ic o BEP mamm I uu MODEL ENV1000L ENV1000H CAPACITY vaw 1000VA 600W 1000VA 600W Voltage 110 120VAC 220 230 240VAC INPUT Voltage Range 89 145VAC 160 290VAC Voltage 110 120VAC __ 220 230 240VAC Voltage Regulation 10 Batt Mode GWE Frequency 50Hz or 60Hz Frequency Regulation 1 14Hz Batt Mode m Modified Sinewave eee Typ amp 12V 7 0 Ah x 2pcs Back up time with two PC 15minutes parese typical 200w Recharge Ti Tohours 10 90 eens me after complete discharge TRANSFER TM
3. E Typical 4 6 ms AG Mode The Tstgreen LED lighting and the 2nd to Sth green LEDs gradually lighting indicating load level INDICATOR Ihe st green LED fashing and the 2nd to Sth green Backup Mode ps gradually lighting indicating battery capacity Fault Red LED lighting Backup Mode Sounding every 10 seconds kinge Low Battery Sounding every second ALARM Overload Sounding every 0 5 seconds Fault Continuously Sounding PROTECTION Surge Suppression EN50091 2 Level 3 Full Protection Discharge overcharge and overload protection Dimension 399x145x205mm 399x145x205mm PHYSICAL DXWXH Net Weight 9 6kgs Operating 0 406 0 50 relative humidity ENVIRONMENTENVitonment non condensing Noise Level Less than 50dB Support Windows 98 NT 2000 INTERFACE use ME xp 2003 Vist Spec ICAPACITY INPUT OUTPUT BATTERY ENV1400H ENV2000H VAIW 1400VA 840W 2000VA 1200W Voltage 220 230 240VAC Voltage Range 166 290VAC Voltage 220 230 240VAC Voltage Regulation 10 Batt Mode Frequency 50 60Hz Frequency Regulation l 14Hz Batt Mode Output Waratarin Modified Sinewave Battery Type eatery Type 12V 9Ah 2pcs 24V model Back up time with two PC 25 minutes typical 200W Recharge Time hours to 90 after complete discharge INDICATOR AUDIBLE ALARM PHYSICAL ENVIRONMENT INTERFACE Typical 4 6 ms The Green Led Lightin AC Mode The 2to 8 green L
4. d by laymen The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Unplug the UPS prior to cleaning and do not use liquid or spray detergent Safety Caution Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch Vor jedem reinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie Keine Fl ssig oder Aerosolreiniger Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung Das Ger t ist vor Feuchtigkeit zu schutzen ffnen Sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicherheit nur von authorisiertem Servicepersonal geoffnct Werden m Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht ubershreiten m VORSICHT Explosionsgetahr bei unsachgem en Austausch der Batterie Ersatz nur durch denselben order einem wom Hersteller empfoblenem hnlichen typ Entsorgung gebrauchter Batterien nach Angaben des Hertellers J IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTION This manual contains important instructions for models ENV1000L H ENV1400H ENV2000H that should be followed during installation and maintenance of the UPS a
5. ed lighting 10 indicate load level The 1 Green Led blinkin Backup Mode rne 2 1o5 gaentedighing to indicate Battery capac Fault Red LED lighting IBackup Mode Sounding every 10 seconds Low Battery Sounding every 1 second PROTECTION Overload Sounding every 0 5 seconds Fault Continuously Sounding Full Protection Overcharge and overload protection Dimension an 405x145x205mm Unit Weight 9 63kgs 9 77kgs Operating 0 40 0 90 relative humidity Environment non condensing Noise Level Less than50dB use Support Windows 98 NT 2000 ME xp 2003 Vista Trouble Shooting Symptom Possible Cause Remedy No LED display 1 Missing battery 1 Charge battery up to on the front 10 hours panel 2 Battery defect 2 Replace with the same type of battery 3 Power switch isnot pressed 3 Press power switch again Alarm buzzer Overload of the UPS Verify that the load failure backup beeps matches the UPS continuously lcapability specified in when AC he specs supply is normal When power 1 Overload of the UPS t Remove some noncritical load time is shorten 2 Battery voltage is too low 2 Charge battery for 10 hours or more Battery defect due to high temperature operation environment orimproper operation to battery B Repl ace with the same type of battery Communication 1
6. nd batteries Safety Caution This UPS utilizes voltage that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only factory service personnel may perform repairs Internal voltage of each battery is 12Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock azard as well as violate local electrical codes In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liguid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces Do
7. not open or mutilate the battery or batteries Release electrolyte is harmful to the skin and eyes It may be oxic Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary g Installation and Operation Installing the UPS is as easy as following the steps shown Be aware of the Power Switch must be kept in the ON position otherwise the UPS will be disabled andyour equipment will not be protected during apower failure Inspection 1 Remove the UPS from its package and inspect it for damage that may have occurred during shipping Ifany damage is discovered re pack the unit and return it to the place of purchase Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do notoperate your UPS inan environment where the ambient temperature or humidity ishigh Onthe other hand place the UPS unit away from the monitor at least 20cm to avoid interference Charging This unit is shipped from the factory with its internal ba
8. replacement Unscrew the panel Remove the front panel Chart 1 lt A Remove the battery cover Chart 2 After removing the battery cover gently extract the batteries by disconnecting the two wires connecting to the UPS Be sure to replace with the same type of batteries and dispose of old batteries properly at an appropriate recycling facility Be sure replaced the same type of the batteries and dispose of old batteries properly at an appropriate recycling facility Chart 3 a WinPower Software WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multicomputer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs sem LQ LPI DIE WOON Eebent LURE Eee a Fern Mikeni ian oom AC LINE eer me Installation procedure Please refer to the installation procedures in the manual of winpower software or the readme file on the software CD for details
9. ttery fully charged however some charge may be lost during shipping and the battery should be recharged prior touse Plug the unit into anappropriate power supply and allow the UPS tocharge fully by leaving it plugged in for atleast 10hours pi 10 hours Computer Connection Connect one computer related device into each of the power receptacles supplied on the back ofthe UPS Modem Phoneline Connection p Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end ofthe Internet line cable to the Out socketat the back ofthe UPS Plug the other end tothe modem input socket as shown below Incoming Internet line Communication cable connection 6 To allow for unattended system shutdown for your operating system connect the USB or Serial cable as per diagram below NN Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again DC Start Function DC Start Function enables UPS tobe started up when AC utility power isnot available and battery is fully charged Just simply press the power switch to turn onthe UPS Battery Replacement O Follow Chart 1 to Chart 3to replace the battery Disconnecting all sources of supply before battery
Download Pdf Manuals
Related Search
Related Contents
Franke GAX 110-45 User Guide - IPSI Scan Operating Instructions - York Survey Supply Centre Tutorial to know the program Manual (non-certified version) CCI Info N_212 Goodman Mfg . Co. LP. Air Conditioner CE COMMERCIAL SPLIT SYSTEM AIR CONDITIONER User's Manual Remote Deposit Complete User Manual. Copyright © All rights reserved.