Home

Chief WMA1S

image

Contents

1. Verwijderen Retirez By Hand A mano Von Hand Com a mao A mano Met de hand la main Optional Opcional Optional Opcional Opzionale Optie En option y d 8 Hex Head Wrench Llave de cabeza hexagonal 9 Ei OO Sechskantschlussel Chave de cabega sextavada Chiave esagonale Zeskantsleutel Cl a t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit WMA1S Installation Instructions TOOLS REQUIRED FOR INSTALLATION e Ai Q 1 2 12 7mm 5 32 12222 included 1 2 12 7mm steel stud 3 8 10 concrete and concrete block 7 32 5 6mm wood 2 x 4 stud B 1 Wall bracket 5 16 x 2 1 2 4 DA ON na di H 2 J 2 N a 4 2 1 5 16 18 x 1 4 8 32 x 1 2 1 4 20 x 1 2 e 1 i i 1 4 20 x 3 4 5 16 18 x 1 2 5 16 18 x 1 4 security security security security e 50 32 x 3 4 Ka 8 32 3 10 24 x 1 5 32 security security U 2 8 x 1 2 V 2 10 x 1 W 1 Top cover Installation Instructions WMA1S Site Requirements WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAU
2. mount in desired position See Figure 21 Stop bracket bottom view Figure 21 11 WMA1S Installation Instructions Security Screw Installation Optional 1 Remove two 8 x 1 2 Phillips screws U and two 10 x 1 Phillips screws V from top and lower covers See Figure 22 2 Install two 8 32 x 1 2 buttonhead security screws and two 10 24 x 1 buttonhead security screws L into top and lower covers See Figure 22 Figure 22 3 Remove two bolts holding stop bracket in place on underside of WMA1S See Figure 23 Sliding nuts location Stop bracket Figure 23 4 Install two 1 4 20 x 1 2 button head security screws J through holes in stop bracket and into holes in sliding nuts See Figure 24 12 Figure 24 5 Optional Remove column from WMA1S according to column installation instructions NOTE For ease of installation it is recommended to remove column prior to performing the following steps For most mounts it will be necessary to remove column prior to install of four security screws to WMA1S 6 Remove of four bolts from adapter plate See Figure 25 Adapter plate x 4 one at a time Figure 25 Installation Instructions WMA1S 7 Install one 1 4 20 x 3 4 button head security screw K into hole vacated by removing bolt in Step 6 and into pl
3. INSTALLATION INSTRUCTIONS Single Stud Wall Mount Accessory Our Mounts Your Vision E CHIEF WMA1S WMA1S Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions DIMENSIONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the inst
4. SING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT The figure below identifies the minimum requirements for installation of display mounts onto a steel stud structure If the structure or its components do not meet these requirements contact the mount manufacturer for specific instructions before attempting installation It should also be noted that no other equipment should be mounted to the same stud 16 on center Studs Display Mount Installation Location Must be centered on stud If back side of wall is unfinished drywall must be installed to a minimum of one stud left and right of the stud s being used to install the mount Drywall must be secured to studs with screws 12 on center gt There must be a minimum of 1 7 8 48mm clearance inside wall Drywall 1 2 minimum Drywall Thickness Both Sides of Stud See hazard statement on page 2 Steel Stud 2 x 4 25ga minimum Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members 362 125 18 C Shape S Stud Section WMA1S Installation Instructions ASSEMBLY AND INSTALLATION WMAI1S single stud wall mount accessory be mounted to concrete concrete block 2 x 4 wood studs or steel studs Installing Mounting Bracket WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING IN
5. THRU ARM MAXIMUM WEIGHT CAPACITY STEELSTUD_ WOODSTUD SOLID CONCRETE CONCRETE BLOCK 50L 22 7 kg 68 8 DIMENSIONS MILLIMETERS INCHES Installation Instructions WMA1S LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Marcar con lapiz Stiftmarkierung Marcar com lapis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere
6. TO ELECTRICAL CORDS OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of gas water waste or any other plumbing before cutting drilling or installing fasteners Concrete or Concrete Block IMPORTANT If installing to a concrete or concrete block wall drywall may NOT be attached to the wall 1 Determine mounting location on wall Figure 2 Wood Studs 1 Determine mounting location on wall Use a stud finder to locate studs 2 Line up inner three holes wall bracket with center of 2 Using wall bracket as a template mark four holes at the stud at desired mounting location See Figure 3 outer bracket holes See Figure 1 3 Using wall bracket as a template mark three holes at 3 Drill four 3 8 x 3 3 8 deep holes at marked locations in wall inner three holes in bracket See Figure 3 See Figure 1 4 Drill three 7 32 x 2 1 2 deep holes at locations marked in Step 3 See Figure 3 front view front view wood stud G 4 of Figure 1 4 Install four concrete anchor
7. aller s responsibility to make sure all components properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm unless noted below Do not install drywall anchors into the seam between drywall pieces WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to the projector wall mount accessory up to and including the attached component s does not exceed e Installed in steel stud 50 Ibs 22 7 kg e Installed 2 x 4 wood stud 150 Ibs 68 0 kg e Installed concrete concrete block with NO drywall attached to wall 150 lbs 68 0 kg 482 6 19 00 MAX 102 292 1 11 50 MIN 401 359 1413 ACCEPTS 1 1 2 NPT OR NPSM THREADS 3 OF LEVEL ADJUSTMENT 135 5 31 49 1 88 1 93 7 40 SECTION A A SCALE 1 2 CABLE CHANNEL DIMENSIONS
8. ards wall until flange of cap is flush with wall See Figure 7 Steel Stud Drywall Plastic Cap gt Anchor Metal Channel side view Figure 7 WMA1S Installation Instructions 8 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 8 9 Repeat Steps 5 through 8 for each mounting hole Steel Stud Drywall Plastic Cap 4 Plastic Straps Anchor Metal Channel side view Figure 8 10 Place wall bracket B over anchors and align mounting holes in wall bracket with holes in anchors See Figure 9 11 Insert 1 4 20 x 1 3 4 Phillips pan head screws F through 1 4 washer E corresponding hole on wall bracket and into anchor G and tighten until flush against bracket DO NOT overtighten See Figure 9 12 Repeat Step 11 for remaining 2 mounting holes WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Overtightening of mounting hardware can damage the steel studs DO NOT overtighten mounting hardware Steel Stud Drywall B Anchor Metal Channel side view Figure 9 Installation to Wall Bracket 1 Lift WMA1S assembly A up to wall bracket B and hook u
9. astic spacer See Figure 26 8 Repeat Steps 6 7 for remaining three bolts one bolt at a time WARNING It is important to replace adapter plate bolts ONE AT A TIME or adapter plate could fall from mount during installation Plastic spacer Adapter plate x 4 one at a time Figure 26 9 Reinstall column according to column installation instructions 13 WMA1S Installation Instructions 14 Installation Instructions WMA1S 15 WMA1S Installation Instructions GS CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8802 002083 Rev01 2011 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 06 11 USA International Europe Asia Pacific gt TU 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 SCH 52 d
10. nding hole on WMA1S mounting plate See Figure 14 IMPORTANT The maximum length column that can be attached to the WMA1S is 48 inches 121 9 2 Install column not included following instructions included with column 3 Install one 5 16 18 x 1 4 set screw or one 5 16 18 x 1 4 security set screw Q through hole in WMA1S mounting plate and column See Figure 14 side view N Column not included Figure 14 WMA1S Installation Instructions Removing Mount Covers 1 Remove two 8 x 1 2 Phillips pan tapping screws U and two 10 x 1 Phillips pan tapping screws V to free top cover W and expose pitch adjustment screw See Figure 15 2 Remove lower cover X from WMA1S See Figure 15 Figure 15 Pitch Adjustment 3 Loosen two 5 16 18 x 1 2 hex head screws on each side of wall bracket See Figure 16 4 Loosen two bolts one on each side of pitch adjustment screw See Figure 16 5 Adjust pitch adjustment screw until mount is at desired pitch level clockwise to raise mounting level e Turn counterclockwise to lower mounting level See Figure 16 6 Tighten two bolts one bolt on either side of pitch adjustment screw See Figure 16 7 Tighten two 5 16 18 x 1 2 screws N one on each side of mounting bracket See Figure 16 8 Return mount covers to the m
11. ount following instructions in Installing Mount Covers section 10 Pitch adjustment screw Lower Raise Figure 16 Cable Management Optional 1 Remove mountcovers from the mount following instructions in Removing Mount Covers section NOTE In most cases the cable management cover will NOT need to be removed in order to route cables from projector to the wall mount But for some thick cables removing the cover may be necessary 2 Remove cable management cover if necessary from WMA1S arm See Figure 17 Cable cover Figure 17 Installation Instructions WMA1S 3 Route projector cable s under mount cover and through 15 arm See Figure 18 Figure 18 4 Optional Cables may be tied to inside of WMA1S front cover using cable ties not included Route cables near front cover and wrap cable tie through slots on front cover and around cables See Figure 19 o Cable tie bottom view not included e Route cable ties through slots and around cables Figure 19 5 Replace removed cable management cover if necessary by snapping it into place See Figure 20 Figure 20 Extension Adjustment 1 Loosen two bolts holding stop bracket in place on underside of WMA1S See Figure 21 Adjust mount to desired extension length See Figure 21 Tighten two bolts holding stop bracket to secure
12. pper plate over upper notches on bracket See Figure 10 2 Slide lower plate into lower notches on bracket See Figure 10 Upper plate A Lower plate Figure 10 3 Fasten WMA1S assembly A to wall bracket B using two 5 16 18 x 1 2 hex head cap screws N through two 5 16 washers S the wall bracket and WMA1S See Figure 11 Figure 11 Installation Instructions WMA1S Installing Mount Covers 1 Raise lower cover X up to WMA1S See Figure 12 Figure 12 Lower top cover W onto WMA1S See Figure 13 Install two 10 x 1 Phillips pan head tapping screws V through holes on sides of covers See Figure 13 4 Install two 8 x 1 2 Phillips pan head tapping screws U into top of top cover W See Figure 13 Figure 13 PROJECTOR INSTALLATION WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight attached to the wall mount accessory up to and including the attached component s does not exceed e Installed in steel stud 50 Ibs 22 7 kg e Installed 2 x 4 wood stud 150 105 68 0 kg e Installed concrete concrete block with NO drywall attached to wall 150 Ibs 68 0 kg Column not included Installation 1 Line up mounting holes on column not included with correspo
13. s into drilled holes See Figure 2 5 Install four 5 16 x 2 1 2 hex head lag screws through four 5 16 washers D outer holes of wall bracket B and into concrete anchors T See Figure 2 Figure 3 Installation Instructions WMA1S 5 Install three 5 16 x 2 1 2 hex head lag screws through three 5 16 washers D inner holes of wall bracket B and into drilled holes See Figure 4 Figure 4 Steel Studs IMPORTANT See Site Requirements section before proceeding with Steel Studs installation to ensure installation site meets requirements The drywall must have a minimum thickness of 1 2 1 Determine mounting location on wall Use stud finder to locate steel studs Line up inner three holes on wall bracket B with center of stud at desired mounting location See Figure 5 Using wall bracket B as a template mark three holes at inner three holes in bracket See Figure 5 Drill three 1 2 holes at marked locations in wall See Figure 5 x3 AS Figure 5 5 Hold metal channel on anchor G flat alongside plastic straps and slide channel through hole See Figure 6 Drywall Plastic Straps Figure 6 6 Holding plastic straps on anchor G pull anchor away from wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 7 7 Slide plastic cap on anchor G tow