Home

Datalogic PowerScan PBT8300

image

Contents

1. 9 PowerScan BT8300 Bluetooth Enabled PC Configuration 9 Before You BegiN a AA AA 10 Unpairing the Reader cases itineris med HUI Cite 10 Linking the PowerScan BT8300 to the BC 8030 BT Cradle 10 Eco eG AA admi quib 11 aecareeaieead 12 UII nd mE 12 Linking the PowerScan BT8300 to a Bluetooth Enabled PC 13 Linking to a PC in Serial Port Profile Slave Mode 13 Linking to a PC in Serial Port Profile Master Mode 14 15 0 Linking to a Variable PIN Code f 15 16 PowerScan BT8300 HID Configuration HID County E OE BB conteste een 16 Caps Lock SIE con cese ord mend EE E E 19 Caps Lock Auto Recognition IBM AT Compatible Only 19 AND a AA AG EIE 19 PowerScan BT8300 Default Configuration 20 21 Reading Distance es ssessesssessesssesseessesseesscrseessesseeseeoseesseosconeroseossessesseossesseessee 22 8 23 Service ara aiaia 23 08 24 R CC 60 gi 7 gt 24 Radio CA APA 24 Quick Reference Guide 1 Laser Safety Compliance saa NGA ond pad od Fr EE 24 KEDE oc aac aroun een amunaiaidinuedias atcaanis 25 E industry aaa nsus bte Pe AA 25 WEEE E ODE B reoos onse sean p AA 26 E 27 2 PowerScan BT8300 PowerScan BT8300 Reader Using the PowerScan BT8300 The PowerScan BT8300 family of readers can be used with either the Powe
2. Country Code Spain Default value PowerScan BT8300 Connecting the PowerScan BT8300 HID Country Codes cont Country Code Belgium Country Code Japanese 106 key Country Code Poland Country Code Hungary Country Code Croatia Country Code Romania Country Code Czech Republic Country Code Slovakia Quick Reference Guide 17 Connecting the PowerScan BT8300 HID Country Codes cont 18 Country Code Denmark Country Code Norway Country Code Portugal Country Code Switzerland PowerScan BT8300 Connecting the PowerScan BT8300 Caps Lock State This option specifies the format in which the reader sends character data Caps Lock State Caps Lock ON Caps Lock Auto Recognition IBM AT Compatible Only Enable Disable Caps Lock State Caps Lock OFF Alt Mode Disable Enable Default value Quick Reference Guide 19 PowerScan BT8300 Default Configuration PowerScan BT8300 Default Configuration DATA FORMAT Code identifier disabled Field adjustment disabled Code length not transmitted Character replacement disabled CODE SELECTION Enabled Codes e EAN 8 FAN 13 UPC A UPC E without ADD ON Check digit transmitted no conversions nterleaved 2 5 Check digit control and transmission variable length code 4 99 char acters e Standard Code 39 No che
3. DATALOGIC PowerScan BT8300 Family Industrial Handheld Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide Datalogic Scanning Inc 959 Terry Street Eugene Oregon 97402 USA Telephone 541 683 5700 Fax 541 345 7140 An Unpublished Work All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means with out prior written permission of Datalogic Scanning Inc or its subsidiaries or affiliates Datalogic or Datalogic Scanning Owners of Datalogic products are hereby granted a non exclusive revo cable license to reproduce and transmit this documentation for the purchaser s own internal busi ness purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this documentation and shall ensure that all notices appear on any reproduc tions of the documentation Should future revisions of this manual be published you can acquire printed versions by contact ing your Datalogic representative Electronic versions may either be downloadable from the Data logic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable
4. This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation FCC ID U4F0015 Radio Compliance Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required Refer to the web site http europa eu int comm enterprise rtte spectr htm for further information CEO Laser Safety Compliance The laser scanner conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN60825 1 at the date of manufacture The laser light is visible to the human eye and is emitted from the output window 1 Laser warning and classification label 2 24 PowerScan BT8300 Compliance La utilizaci n de procedimientos o regulaciones diferentes de aquellas describidas en la documentaci n puede causar una exposici n peligrosa a la luz l ser visible CAUTION The laser scanner utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc The following in
5. any product that has been subject to misuse accidental damage unauthorized repair or tampering Service and Support Datalogic provides several services as well as technical support through its website Log on to www scanning datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software amp Utilities including Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 and USB COM interface configuration as well as configuration bar code printing SERVICE amp SUPPORT Technical Support Product documentation and programming guides and Technical Support Department in the world Service Programs Warranty Extensions and Maintenance Agreements Repair Services Flat Rate Repairs and Return Material Authorization RMA Repairs Downloads Manuals amp Documentation Data Sheets Product Cata logues etc CONTACT US Information Request Form and Sales amp Service Network Quick Reference Guide 23 Compliance Compliance This device must be opened by qualified personnel only The batteries must be removed before opening the device FCC Compliance Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment
6. essential requirements under article 3 2 of the R amp TTE Directive EN 60950 1 December 2001 INFORMATION TECHNOLOGY EQUIPMENT SAFETY Part 1 General requirements December 14th 2007 Australia Datalogic Scanning Pty Ltd Telephone 61 2 9870 3200 australia scanning datalogic com France and Benelux Datalogic Scanning SAS Telephone 33 01 64 86 71 00 france scanning datalogic com Germany Datalogic Scanning GmbH Telephone 49 0 61 51 93 58 0 germany scanning datalogic com India Datalogic Scanning India Telephone 91 22 64504739 india scanning datalogic com Italy Datalogic Scanning SpA Telephone 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scanning Singapore PTE LTD Telephone 65 6435 1311 singapore scanning datalogic com Iberia Datalogic Scanning SAS Sucursal en Espana Telephone 34 91 746 28 60 spain scanning datalogic com United Kingdom Datalogic Scanning LTD Telephone 44 0 1582 464900 uk scanning datalogic com DATALOGIC www scanning datalogic com Datalogic Scanning Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 683 5700 Fax 541 345 7140 1 Datalogic Scanning Inc May 2011
7. eye Quick Reference Guide 5 Installing the Battery Pack Always charge the battery at 32 113 F 0 45 C tempera ture range Use only the authorized power supplies battery pack char gers and docks supplied by your Datalogic reseller The use of any other power supplies can damage the device and void your warranty CAUTION Do not disassemble or modify the battery The battery contains safety and protection devices which if damaged may cause the battery to generate heat explode or ignite Do not place the battery in or near fire on stoves or other high temperature locations Do not place the battery in direct sunlight or use or store the battery inside cars in hot weather Doing so may cause the bat tery to generate heat explode or ignite Using the battery in this manner may also result in a loss of performance and a shortened life expectancy Do not place the battery in microwave ovens high pressure containers or on induction cookware Immediately discontinue use of the battery if while using charging or storing the battery the battery emits an unusual smell feels hot changes color or shape or appears abnormal in any other way Do not replace the battery pack when the device is turned on Do not remove or damage the battery pack s label Do not use the battery pack if it is damaged in any part Battery pack usage by children should be supervised As with other types of batteries Lithium Io
8. follow the instructions below and read the bar codes in the given sequence l Select the COM Ports tab on the Window s Bluetooth Manager and add the Incoming Port You will receive a notification that the Incoming Port is added successfully Open the Incoming Port using your application program for test purposes you can verify the communication using the Hyperterminal tool in Win dows Enter Configuration Serial Port Profile Master Host Address 4 12 digits for the Host Bluetooth adapter Exit and Save Configuration When prompted for a passkey enter the default of 1234 or whatever you have already assigned to your scanner Four ascending beeps will be emitted signaling that the PowerScan BT8300 has been successfully connected to the Bluetooth enabled PC and the Green LED on the reader will stop blinking END of procedure YOUR READER IS NOW READY TO READ CODES 14 PowerScan BT8300 Connecting the PowerScan BT8300 Linking to a PC in HID To link a PowerScan BT8300 reader in HID to a Bluetooth enabled PC please read the following bar codes in the given sequence Enter Configuration HID Profile 3 Exit and Save Configuration 4 Use the host computer s Bluetooth Manager to Add Bluetooth Device Wizard and select PowerScan BT8300 In the next window enter the PIN code if you are using Security Mode 2 or Security Mode 3 or choose Don t use passkey if you se
9. 80 chargers as described in this Quick Reference Guide A full charge takes 4 hours if using an external power supply while it takes up to 10 hours if supplying power through the USB port Configure the reader as described in this Quick Reference Linking the PowerScan BT8300 to the BC 8030 BT Cradle on page 10 Configure the BC 8030 BT cradle See BC 8030 BT Configuration in the BC 8030 BT Quick Reference PowerScan BT8300 Bluetooth Enabled PC Configuration 1 pa Install any drivers provided with the Bluetooth adapter Charge the PowerScanTM BT8300 battery using a BC 8030 BT the CHR PM80 or the MC P080 chargers as described in this Quick Refer ence Guide A full charge takes 4 hours if using an external power supply while it takes up to 10 hours if supplying power through the USB port Configure the reader as described in this Quick Reference Linking the PowerScan BT8300 to a Bluetooth Enabled PC on page 13 Quick Reference Guide 9 Connecting the PowerScan BT8300 Before You Begin In order to use the connection procedures below the handheld and base station must be in an UNPAIRED state If the reader is connected to a device you must follow the procedure below to UNPAIR the Base Station and the handheld before attempting to link to a new device If the handheld is not already connected to another device then you can skip this step and go straight to the Linking instructions that begin on the next page Unpairi
10. 8000 battery charger The Reader LED on the cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green Figure 1 Changing the Batteries Do not incinerate disassemble short terminals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect type Dispose of the batteries as required by the relevant laws in force WARNING Quick Reference Guide 7 Setup Setup Restore PowerScan BT 8300 Default Before starting configuration and every time you want to restore factory settings read the label below Please note that the default mode on PowerScan BT 8300 is Handheld Cradle communication Restore PowerScan BT 8300 Default Scan the following bar codes in sequence to set the date and time for the PowerScan BT8300 Date and Time Setup Enter Configuration Set Date 3 Six digits for Day Month and Year DDMMYY Set Time p Four digits for Hours and Minutes HHMM Exit and Save Configuration 8 PowerScan BT8300 Connecting the PowerScan BT8300 Connecting the PowerScan BT8300 Overview PowerScan BT8300 BC 8030 BT Configuration l Connect a BC 8030 BT cradle to the Host For installation and connec tion information see the BC 8030 BT Quick Reference Guide Charge the PowerScan BT8300 battery using a BC 8030 BT the CHR PM80 or BC P0
11. NG To charge the Battery Pack See Charging the Batteries on page 7 Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance Do not discharge the battery using any device except for the scanner When the battery is used in devices other than the designated product it may damage the battery or reduce its life expectancy If the device causes an abnormal current to flow it may cause the battery to become hot explode or ignite and cause serious injury Lithium ion battery packs may get hot explode or ignite and cause serious injury if exposed to abusive conditions Be sure to follow the safety warnings listed below Do not place the battery pack in fire or heat Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object such as wire Do not carry or store the battery pack together with metal objects Do not pierce the battery pack with nails strike it with a ham mer step on it or otherwise subject it to strong impacts or shocks Do not solder directly onto the battery pack Do not expose the battery pack to liquids or allow the battery to get wet Do not apply voltages to the battery pack contacts In the event the battery pack leaks and the fluid gets into your eye do not rub the eye Rinse well with water and immediately seek medical care If left untreated the battery fluid could cause damage to the
12. between 630 680 nm Display Indicators Laser Features Power max in mW Light Source Scan Rate 35 4 5 scans sec Reading Field Width typical see reading diagram Max Resolution 0 076 mm 3 mils 0 19 mm 7 5 mils PCS minimum 1596 2596 Datalogic Test Chart Scan Angle 42 135 0 7 Laser Safety Class 2 EN 60825 1 CDRH Bluetooth Features Protocol Bluetooth 2 0 Class 1 or Class 2 configurable SPP Serial Port Profile or HID Human Interface Device profile Radio Frequency 2 40 to 2 48 GHz Environmental Features Working Temperature 20 to 50 C 4 to 122 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Protection Class IP64 with display IP65 without display Weight with batteries Keyboard BT8300 no keyboard or display BT8300 D 3 key keypad and display BT8300 DK 16 key keypad and display Quick Reference Guide 21 Reading Distance Reading Distance PowerScan BT8300 PowerScan BT8300 AR 100 1 5 12 5m 4 9 41 0 ft refl Paper 22 PowerScan BT8300 Warranty Warranty Datalogic warranties this product against defects in workmanship and materials for a period of 3 years from the date of shipment provided that the product is operated under normal and proper conditions Datalogic has the faculty to repair or replace the product these provisions do not prolong the original warranty term The warranty does not apply to
13. ck digit control variable length code 1 99 characters Code 128 variable length code 1 99 characters Disabled Codes EAN 128 ISBT128 Code 93 Codabar pharmaceutical codes MSI Code 11 Code 16K Code 49 GS1 DataBar GS1 DataBar includes the following symbologies GS1 DataBar Omnidirectional GS1 DataBar Stacked GS1 DataBar Expanded and GS1 DataBar Limited RADIO PARAMETERS Security Mode 1 Handheld Cradle role and HID role 2 Serial Port Profile Master and Serial Port Profile Slave Default PIN code 1234 Default Friendly Name POWERSCAN BT8300 SERIAL NUMBER Default power class 1 Default role Reader communicates with Base Poweroff timeout 4 hours Autoconnect enable Autoreconnect enable Batch Mode disable OPERATIVE MODE DK Models only Simple Data Input Mode FUNCTION KEYS DEFAULT DK Models only e F1 backlight label Lgt F2 insert a dot in the edit field label 1 e F3 backspace label F4 clear the display label CLR 20 PowerScan BT8300 Technical Features Technical Features Electrical Features Battery Type 2150 Li lon battery pack Time of recharge max 4 hours with external power supply max 10 hours with Host power Operating autonomy 50 000 reads typical continuous reading LCD 4 lines x 16 chars Programmable LED backlight Good Read LED green Good Read Spot green Beeper BT8300 BT8300 AR 0 9 mW 1 3 mW VLD in the range
14. ed the first time a connection is made between the PowerScan PBT8300 and a generic Bluetooth peripheral For fur ther information download Initial Bluetooth Connection Guide available on the Datalogic website in the PowerScan BT section Linking to a PC in Serial Port Profile Slave Mode To link a PowerScan BT8300 reader in Serial Port Profile Slave Mode to a Bluetooth enabled host read the following codes in the given sequence Enter Configuration Serial Port Profile Slave Exit and Save Configuration 4 Use the HOST computer s Bluetooth manager to Add Bluetooth Device Wizard and select PowerScan BT8300 When prompted for a passkey enter the default of 1234 or whatever you have already assigned to your scanner A window will notify you of Incoming Port and Outcoming Port when the PowerScan B T8300 is successful added to the PC 5 Open the Outcoming Port using your application program for test pur poses you can verify the communication using the Hyperterminal tool in Windows 6 Four ascending beeps will be emitted signaling that the PowerScan BT8300 has been successfully connected to the Bluetooth enabled PC END of procedure YOUR READER IS NOW READY TO READ CODES Quick Reference Guide 13 Connecting the PowerScan BT8300 Linking to a PC in Serial Port Profile Master Mode To link a PowerScan BT 8300 reader in Serial Port Profile Master Mode to a Bluetooth enabled host
15. es mod les und seine Modelle y todos sus modelos sono conformi alla Direttiva del Consiglio Europeo sottoelencata are in conformity with the requirements of the European Council Directive listed below sont conformes aux sp cifications de la Directive de l Union Europ enne ci dessous der nachstehenden angef hrten Direktive des Europ ischen Rats entsprechen cumple con los requisitos de la Directiva del Consejo Europeo seg n la lista siguiente 1999 5 EEC R amp TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas ETSI EN 301 489 3 v1 4 1 August 2002 ElectroMagnetic Compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 3 Specific conditions for Short Range Devices SRD operating on frequencies between 9 kHz and 40 GHz ETSI EN 300 220 3 v1 1 1 September 2000 Electromagnetic compatibility and Radio spectrum Matters ERM Short Range Devices SRD Radio equipment to be used in the 25 MHz to 1000 MHz frequency range with power levels ranging up to 500 mW Part 3 Harmonized EN covering
16. formation is shown on the laser scanner device class label CAUTION CLASS 2 LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER LIGHT EMITTED FROM THIS APERTURE DO HOT STARE INTO BEAM This product complies with 21 CFR Bubehapaer J ITALIANO LUCE LASER DEUTSCH LASERSTRAHLUNG Classe2 NON FISSARE ILRAGGIO Klasse 2 NICHT IN DEN STRAHL APPARECCHIO LASER DI PRODUKT DER LASERKLASSE 2 CLASSE 2 FRANCAIS RAYON LASER ESPANOL RAYO LASER Classe 2 EVITER DE REGARDER LEClase 2 NO MIRAR FIJO EL RAYO RAYON APARATO L SERDE CLASE 2 APPAREIL LASER DE CLASSE 2 LED CLASS Class 1 LED product This product conforms to EN60825 1 2001 IC Industry Canada Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Quick Reference Guide 25 Compliance WEEE Compliance Waste Electrical and Electronic Equipment WEEE Statement English For information about the disposal of Waste Electrical and Electronic Equipment WEEE please refer to the website at www scanning datalogic com Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www scanning datalogic com French Pour toute information relative l limination des d chets lectroniques WEEE veuillez consulter le site Internet www scannin
17. g datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altgeraten WEEE erhalten Sie auf der Webseite www scanning datalogic com Spanish Si desea informaci n acerca de los procedimientos para el desecho de los residuos del equipo el ctrico y electr nico WEEE visite la p gina Web www scanning datalogic com Portuguese Para informag es sobre a disposicao de Sucatagem de Equipamentos El ctricos e Eletr nicos WEEE Waste Electrical and Electronic Equipment consultar o site web www scanning datalogic com Chinese Ay AD EEE ATA WEEE NAG 82 2 Datalogic 255 Pis http www scanning datalogic com Japanese REBAR WEEE DIRT OV COMES Ald Datalogic 044 k www scanning datalogic com TAE TF av 26 PowerScan BT8300 Hex Numeric Table 0 2 4 6 8 Quick Reference Guide Hex Numeric Table 1 3 5 7 9 27 Hex Numeric Table Hex Numeric Table continued A TUA B JUL C 5 E F Cancels an incomplete configuration sequence Exit and Save Configuration 28 PowerScan BT8300 DATALOGIC Datalogic Scanning Inc 959 Terry Street C 6 Eugene OR 97402 07 dichiara che declares that the declare que le bescheinigt da das Ger t declare que el PowerScan BT83xx Cordless Bar Code Reader e tutti i suoi modelli and all its models et tous s
18. it and Save Configuration 4 5 Firmly position the reader onto the cradle The BC 8030 BT cradle will emit a beep and the yellow LED will blink while the cradle is trying to establish the connection Four ascending beeps will be emitted signaling that the BC 8030 BT cra dle has been successfully connected to the PowerScan BT8300 and the yellow LED on the cradle will stop blinking 6 To connect another PowerScan PBT8300 to the BC 8030 BT cradle repeat the sequence from steps 1 through 5 One Cradle can connect with a maximum of four readers 7 Upon completing the connection between the reader and cradle you must set up the correct interface for your system Refer to the BC 8030 BT Base Station Charger QRG for information and programming labels and scan the appropriate bar code to select your systems interface type END of procedure YOUR READER IS NOW READY TO READ CODES Quick Reference Guide 11 Connecting the PowerScan BT8300 Link by Inquiry Enter Configuration Handheld Cradle Exit and Save Configuration 4 To connect another PowerScan PBT8300 to the BC 8030 BT cradle repeat in the sequence from steps 1 through 3 before continuing One Cra dle can connect with a maximum of four readers 5 Quickly press the button 8 seconds and release on the BC 8030 BT cra dle The yellow LED on the cradle will blink and it will search for any PowerScan BT 8300 readers in radio
19. measures to provide information in this manual that is complete and accurate however Datalogic reserves the right to change any specification at any time with out prior notice Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U All other brand and product names referred to herein may be trademarks of their respective owners Patents This product is covered by one or more of the following patents Design Pat AU 310201 AU 310202 CN 693980 CN735959 HK 0602013 5M001 HK 0602013 5M002 JP 1305693 KR 30 0460940 US D570 843 S USD588 596 S US Pat 5 992 740 6 305 606 B1 6 412 698 B2 6 517 003 6 808 114 B1 6 997 385 B2 7 387 246 B2 5 367 151 5 449 893 5 545 889 6 098 877 6 220 514 B1 6 412 698 B2 6 607 132 B1 6 817 529 B2 6 834 805 B2 European Pat 789 315 B1 895 175 B1 1 128 314 B1 1 128 315 B1 1 396 811 B1 1 413 971 B1 1 816 585 B1 1 942 442 B1 Additional patents pending Table of Contents Using the PowerScan BT8300 used ier entr od M SUR bI SEP toe ota dING 3 acm Lbs POSEE Lo iint aa 3 PONG TE T m 3 Aming Bo ci zio MN AA 4 Installing the Battery PACK NAN NANAIG EGG 5 Charging AA PAA 7 ees 8 Restore PowerScan BT 8300 Default 8 Dateand Time Setup 2 8 8 Connecting the PowerScan BT8300 centros On II Visit o visio 9 Gl M X S 9 PowerScan BT8300 BC 8030 BT Configuration
20. n LI batteries will lose capacity over time Capacity deterioration is noticeable after one year of service whether the battery is in use or not It is difficult to precisely predict the finite life of a LI battery but cell manufacturers rate them at 500 charge cycles In other words the batteries should be expected to take 500 full discharge charge cycles before needing replacement This number is higher if partial discharging recharging is adhered to rather than full deep discharging The typical manufacturer advertised useful life of LI batteries is one to three years depending on usage and number of charges etc after which they should be removed from service especially in mission critical applications Do not continue to use a battery that is showing excessive loss of capacity it should be properly recycled disposed of and replaced For most applications batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns Collect and recycle waste batteries separately from the device in comply with European Directive 2006 66 EC 2002 95 EC 2002 96 EC and subsequent modifications US and China regulatory and others laws and regulations about the environment 6 PowerScan BT8300 Installing the Battery Pack Charging the Batteries Once the BC 8030 BT C 8000 is powered you can charge the reader s batteries Place the PowerScan BT8300 into the BC 8030 BT cradle or the C
21. ng the Reader To unpair the PowerScan B T8300 reader from a BC 8030 BT base station press and hold the button on the BC 8030 BT 58 seconds then read the Unpair bar code below with each PowerScan B T8300 which you want to unpair from the cradle Unpair You can Unpair the PowerScan BT8300 reader from a Bluetooth Enabled PC to make it available for pairing with another PC Read the bar code above to disconnect the reader from its PC Please note that in order to connect different scanners to a Base that is already connected to the maximum four scanners you must follow the procedure above Linking the PowerScan BT8300 to the BC 8030 BT Cradle The PowerScan BT 8300 reader can be connected with the PowerScan BC 8030 BT cradle in either of three ways After the BC 8030 BT cradle is powered on and connected to the Host configure the Power Scan BT8300 by reading the following bar codes in the given sequence as described in each section Remember The mandatory condition for establishing a new connection between a BT reader and a BT cradle is that they share the same security configuration The connection timeout is 30 seconds Four ascending beeps from the reader indicate a successful link otherwise there are four descending tones 10 PowerScan BT8300 Connecting the PowerScan BT8300 Link by Contact Read the bar codes in sequence as shown in the steps below Enter Configuration Handheld Cradle Link by Contact Ex
22. rScan BC 8030 BT base station or a Bluetooth enabled PC to build a Cordless Reading System for the collection decoding and transmission of bar coded data TM 6 PowerScan BT8300 laser readers automatically scan bar codes at a distance Simply aim and pull the trigger Scan Line Position Code scanning is performed along the scan line emitted from the reading window This line must cross the entire code The best reading angles are indicated in the figure below NO NO OR OK Reading Angle Successful scanning is obtained by tilting the reader with respect to the bar code to avoid direct reflections that impair the reading performance see the figure below Quick Reference Guide 3 Using the PowerScan BT8300 Aiming System IM PowerScan BT8300 provides an aiming system If enabled a partial trigger press produces a red spot which should be aimed over the code center to get the best reading performance see 1 in the figure above By completely pressing the trigger the scan line appears to start the code scanning see 2 Mfter setting up the reader you can enable or disable the aiming system by reading the codes below Disable Aiming System Default Enable Aiming System 4 PowerScan BT8300 Installing the Battery Pack Installing the Battery Pack To install charge and or do any other action on the battery follow the instructions in this manual WARNI
23. range After finishing the cradle will emit a beep and begin to link with PowerScan BT8300 readers found 6 The green LED on each PowerScan BT8300 reader will blink when the BC 8030 BT cradle tries to link with it To confirm the connection with the cradle press the trigger on the reader within 10 seconds before the timeout expires 7 Four ascending beeps will be emitted signaling that the BC 8030 BT cra dle has been successfully connected to the PowerScan BT8300 and the green LED on the reader will stop blinking 8 Upon completing the connection between the reader and cradle you must set up the correct interface for your system Refer to the BC 8030 BT Base Station Charger QRG for information and programming labels and scan the appropriate bar code to select your systems interface type END of procedure YOUR READER IS NOW READY TO READ CODES Link by Label You can create a label that includes the appropriate command and the cradle MAC address Please refer to the Product Reference Guide PRG or contact Technical Support for more information 12 PowerScan BT8300 Connecting the PowerScan BT8300 Linking the PowerScan BT8300 to a Bluetooth Enabled PC The PowerScan BT8300 reader can optionally be linked to a Bluetooth enabled host with the serial port profile SPP or human interface device HID as a virtual keyboard Depending on the driver used by your device specific actions may be requir
24. t Security Mode 1 The default Security Mode in HID mode is Authentication and Encryption Disable 5 Four ascending beeps will be emitted signaling that the PowerScan BT8300 has been successfully connected to the Bluetooth enabled PC END of procedure YOUR READER IS NOW READY TO READ CODES Variable PIN Code Some Bluetooth drivers on the Host such as WIDCOMM and BlueSoleil 8 require a Variable PIN Code When attempting connection the application presents a window that includes a PIN Code which is to be input using the PowerScan BT8300 Please read the bar code Variable PIN Code and restart the Variable PIN Code sequence from step 4 above When you hear the beep indicating the reader is waiting for an alphanumeric entry enter the variable PIN Code one of two ways Keypad PBT8300 16 key DK only Type the PIN Code on the scanner keypad then tap Enter Scanning Read the bar code corresponding with the require PIN Code and ending with Exit and Save configuration label Use the labels in the HEX NUMERIC KEYPAD section at the back of this manual for alphanumeric entry Quick Reference Guide 15 Connecting the PowerScan BT8300 PowerScan BT8300 HID Configuration HID Country Codes 16 Country Code U S Country Code Italy Country Code France Country Code Germany Country Code Britain Country Code Sweden

Download Pdf Manuals

image

Related Search

Related Contents

INSTRUCCIONES DE USO  EPSON ePOS-Device XML User`s Manual  

Copyright © All rights reserved.
Failed to retrieve file