Home
TFA 42.6000.06 anemometer
Contents
1. Average time for current speed measurement setting The current wind speed can be measured in average wind speed in a time interval 2 10 seconds 1 Following from the C and F Setting press key to set the desired average time The range runs from 2 to 10 seconds 2 Once the desired average time has been chosen press the MODE key to confirm and back to the normal mode LCD back light The LCD back light is automatically switched ON when any one of the 2 function keys are pressed and held down about 2 seconds The back light will be switched on for approximately 8 seconds before automatically switching OFF Fastening the necklace The carry necklace is supplied with the anemometer To fasten simply insert the clip of the necklace into the buckle end of the anemometer until it clicks into place To unfasten simply press both sides of the clip until it can be removed from the buckle Battery change It is recommended to replace the battery in the unit on an annual basis to ensure optimum accuracy of this unit Please help in the preservation of the environment Return used batteries to an authorised depot Maintenance e Avoid placing anemometer in areas prone to vibration and shock as these may damage and inaccurate readings e Avoid exposure to sudden changes in temperature such as direct sunlight extreme cold and wet or moist conditions e When cleaning the display and casing use a soft damp cloth
2. only Do not use solvents or souring agents as they may mark the LCD and casing e Do not make or attempts to make any repairs to the anemometer Return it to its original point of purchase for repair by a qualified engineer Opening and tampering with the unit may invalidate its guarantee Specifications Recommended operating temperatures 29 9 C to 59 C with 0 1 C resolution displayed if outside this range every 10 seconds Minimum 0 2 m s Maximum 30 m s 5 or least significant digit 1 x 3V lithium cell CR2032 Approximately 12 months The battery life might be shorter than 12 months depending on the use of the backlight 50 x 18 x 137 mm Temperature checking interval Wind speed measuring range Wind speed accuracy Power source Battery life Dimensions L x W x H Liability Disclaimer e The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written consent of the manufacturer
3. Hand held Anemometer Operating Manual Introduction Congratulations on purchasing this pocket sized anemometer this innovative product provides wind speed wind chill and temperature information for any outdoor activities The operation of this product is simple and straightforward and by reading this operating manual users will receive the optimum benefits of all its features The Anemometer SWS J SH Impeller MODE key Battery cover f key Features Wind speed measure in mph Km h m s or Knots Wind speed in Beauford wind scale bar graph Wind chill display Temperature display in degrees Celsius or Fahrenheit LCD back light Auto power OFF Neck band included Water resistance Setting up 1 Firstly use a large coin to open the battery cover at the back of the anemometer as indicated above 2 Checking the correct polarization insert 1 x 3V CR2032 lithium cell positive pole up into the battery compartment and replace the cover 3 When the battery is inserted all the segments of the LCD and back light will light up briefly Battery compartment Your anemometer is now operational Note After inserting the battery test the anemometer by blowing directly at the Impeller for about 30 seconds The reading on the LCD should change If it is not the case remove the battery Wait for 30 seconds and re insert the battery again Lithium cell Battery C
4. R2032 cover Function keys The anemometer uses the following keys MODES key To toggle between wind speed and temperature wind chill display Power ON OFF To enter the setting node Back light On Key To change operation mode PLUS To change parameter in setting mode Back light On Selection of operation mode There are two modes one is wind speed and another is temperature By pressing the MODES key the display will toggle between wind speed and temperature wind chill Wind speed Mode The wind speed mode can be selected into 3 different displays at any time Dis bre A WIND s ace Maximum wind speed Average wind speed Since power on Since power on EY OMINIW AO Current wind speed To toggle between current wind speed maximum wind speed and average wind speed simply press the key Beaufort wind scale bft Force pesatiotion The Beaufort scale is con At ee displayed in bar graph 3 Gertie Breese 0 12 This is a system 4 Moderate Breeze for estimating wind 5 Fresh Breeze force without the use of 6 Strong Breeze instruments based on 7 Near Gale the visible effects of the 8 Gale wind on the physical 9 Strong Gale environment Storm Violent Storm Hurricane Temperature and Wind chill Mode The Temperature and wind chill modes can be selected into 2 different displays at any time Wind chill Temperature By pressing the key the d
5. isplay will toggle between temperature and wind chill When the temperature is outside the range from 29 9 C to 59 C there will be no wind chill measurement Wind chill The anemometer calculates automatically wind chill which can provide useful information for preparing outdoor activities in cold weather Wind chill provides an indication of how cold it feels given the combined effects of the actual air temperature and the wind speed Power ON OFF Press and hold down the MODE key for 2 seconds to switch ON OFF Note The anemometer is automatically switched OFF when no key is pressed in 34 minutes Manual setting Before entering the manual setting mode switch off the anemometer Press and hold down the MODE key for about 4 seconds the speed unit will start flashing on the LCD when the manual setting mode is entered Measurement scale setting A After entering the manual setting mode press key to set the measurement scale in Km h Kilometers per hour mph miles per hour m s meters per seconds or Kts Knots 2 Now press the MODE key to confirm and enter the C and F setting C and F setting i Following from the measurement scale Setting C will be flashing use the key to toggle C and F 2 Once the desired temperature unit has been chosen press the MODE key to confirm and enter the Average time for current speed measurement setting
Download Pdf Manuals
Related Search
Related Contents
取扱説明書/72KB ASUS B53S User's Manual Toshiba IK-7100A Security Camera User Manual Port Designs Mobile Laptop Lap desk STAR LASER User Manual – Preliminary Edition JVC RC-EX36S User's Manual Manuale d`istruzione Attuatori elettrici SIPOS 5 ECOTRON 5120i com SAR Internet.book Copyright © All rights reserved.