Home

TFA 30.3032.10.IT digital body thermometer

image

Contents

1. Display current indoor temperature Display daily minimum and maximum indoor temperature 54 Section 3 OUTDOOR TEMPERATURE Display current outdoor temp Display daily maximum and minimum outdoor temperature DCF 77 RADIO CONTROLLED TIME The time base for the radio controlled time is a Cesium Atomic Clock operated by the Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than one second in one million years The time is coded and transmitted from Mainflingen near Frankfurt via frequency signal DCF 77 77 5 kHz and has a transmitting range of approximately 1 500 km Your radio controlled Weather Temperature station receives this signal and converts it to show the precise time in summer or wintertime The quality of the reception depends greatly on the geographic location In normal cases there should be no reception problems within a 1 500 km radius around Frankfurt Once the outdoor temperature is displayed on the station after initial set up the DCF tower icon in the clock display will start flashing in the upper left corner This indicates that the clock has detected that there is a radio signal present and is trying to receive it When the time code is received the DCF tower becomes permanently lit and the time will be displayed 55 If the tower icon flashes but does not set the time or the DCF tower does not appear at all then please take note of the following Recommended distance
2. 4 Neighbors using electrical devices operating on the 868MHz signal frequency can also cause interference Note When the 868MHz signal is received correctly do not re open the battery cover of either the transmitter or Temperature Station as the batteries may spring free from the contacts and force a false reset Should this happen accidentally then reset all units see Setting up above otherwise transmission problems may occur 68 The transmission range is about 100 m from the transmitter to the Temperature Station in open space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up MOUNTING POSITIONING THE TEMPERATURE STATION The Temperature Station is designed to be hung onto wall or free standing To wall mount Choose a sheltered place Avoid direct rain and sunshine Before wall mounting please check that the outdoor temperature values can be received from the desired locations de Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm 2 Remove the stand from the Temperature Station by pulling it away from the base and hang the station onto the screw Remember to ensure that it locks into place before releasing 69 Free standing With the stand the Temperature Station can be placed onto any flat surface
3. POSITIONING THE TEMPERATURE TRANSMITTER The transmitter is supplied with a holder that may be attached to a wall with the two screws supplied The transmitter can also be position on a flat surface by securing the stand to the bottom to the transmitter 70 To wall mount 1 Secure the bracket onto a desired wall using the screws and e plastic anchors 2 Clip the transmitter onto the bracket c c Note Before permanently fixing the transmitter wall base place all units in the desired locations to check that the outdoor temperature reading is receivable In event that the signal is not received relocate the transmitters or move them slightly as this may help the signal reception CARE AND MAINTENANCE Extreme temperatures vibration and shock should be avoided as these may cause damage to the unit and give inaccurate forecasts and readings When cleaning the display and casings use a soft damp cloth only Do not use solvents or scouring agents as they may mark the LCD and casings Do not submerge the unit in water 7 Immediately remove all low powered batteries to avoid leakage and damage Replace only with new batteries of the recommended type Do not make repair attempts to the unit Return them to their original point of purchase for repair by a qualified engineer Opening and tampering with the unit may invalidate their guarantee Do not expose the units to extr
4. disturbances transmitting distance etc the time can be manually set The clock will then work as a normal Quartz clock TIME p E Minutes flashing To set the clock 1 The hour digits start flashing in the time display section 2 Use the key or CH key to adjust the hours and then press SET key to go to the minute setting 3 Theminute will be flashing Press the key or CH key to just the minutes 4 Confirm with the SET key and enter the Calendar Setting or exit the setting mode by pressing the MIN MAX key Hours flashing 60 CALENDAR SETTING HIE E CLLB Dt L Date Month for 24h time display Month Date for 12h time display The date default of the temperature station is 1 1 of the year 2006 after initial set up Once the radio controlled time signals are received the date is automatically updated However if the signals are not received the date can also be set manually To do this 1 The year is flashing Using the key or CH key set the year required The range runs from 2006 to 2029 default is 2006 2 Press the SET key to enter the month setting mode 3 The month digit will be flashing Press the key or CH key to set the month and then press the SET key to go to the day setting 4 The day digit will be flashing Press the key or CH key to set the day 61 5 Confirm with SET key and enter the F C TEMPERATURE UNIT SETTING or exit the
5. setting mode by pressing the MIN MAX key Note The weekday of calendar will be automatically set after the month and day value is input C F TEMPERATURE UNIT SETTING Lj flashing L The default temperature reading is C degree Celsius To select F degree Fahrenheit 1 The F or will be flashing use the key or CH key to toggle between F and oor 2 Once the desired temperature unit has been chosen confirm with the SET key to exit the setting mode 62 DISPLAY OF INDOOR TEMPERATURE READING The indoor temperature is measured and displayed on the second section of the LCD IN J r Or L Indoor a J Temperature COE m 285 Indoor Icon DISPLAY OF OUTDOOR TEMPERATURE READING The bottom LCD section shows the outdoor temperature Outdoor icon _ QUT p or 2 L Outdoor y L Temperature m 2 63 DISPLAY OF INDOOR MINIMUM AND MAXIMUM RECORDS 1 In normal display mode press the MIN MAX key once the minimum indoor temperature will be shown in LCD Also the time and date of recording this temperature will be displayed 77 H Time and date of record IN Indoor icon or L Minimum indoor 0 6 MIN temp recorded Then press the MIN MAX button one more time the maximum indoor temperature will be shown in LCD Also the time and date of recording this temperature will be displayed 64 3 Press three more
6. temperature to Temperature Station by 868 MHz signals Dual channel transmitter one internal channel and one probe channel Shower proof casing Wall mounting and table stand This socket is only for the external probe Do not apply power plug to it Optional external probe DUAL CHANNEL TRANSMITTER There are an internal channel and an external probe channel in the transmitter The data measured by the internal sensor and the measuring probe will be shown on the transmitter s display as Channel 1 and 2 respectively The two readings will be 44 automatically toggled to display However if the probe is unplugged the transmitter s display will only show the reading from the inner transmitter Once the transmitter is successfully recognized by the temperature station Channel 1 of the Temperature station will display the temperature data measured by internal sensor and Channel 2 will display the temperature estimated by the probe If the measuring probe is unplugged the probe channel on Temperature station will show yet the data from the internal transmitter will still be shown on Channel 1 The probe can be connected to the remote temperature transmitter anytime after initial setup There is no need to reset the units should the probe be unplugged or re plugged again The Temperature Station will automatically detect the temperature probe data and will display the temperature data on Channel 2 after the prob
7. time the MIN MAX button to go back to the normal display DISPLAY OF OUTDOOR MINIMUM AND MAXIMUM RECORDS 1 In normal display mode Press the MIN MAX button three times the outdoor minimum temperature and the time and date of recording this temperature will be displayed 2 Press the MIN MAX button once more the outdoor maximum temperature and the time and date of recording this temperature will be displayed 2 4 B H Time and date of record Outdoor icon OUT Outdoor Channel No MAX Jii Maximum outdoor temp recorded 65 RESETTING THE INDOOR AND OUTDOOR MINIMUM MAXIMUM RECORDS 1 In normal display mode press the MIN MAX button once to advance to the indoor MIN temp display 2 Press and hold the MIN MAX key for about 3 seconds this will reset the currently shown indoor and outdoor minimum and maximum data to the current time date and temperature 3 Then press the MIN MAX button three more times to return to the normal display Note The indoor minimum and maximum record as well as the minimum and maximum records of all outdoor channels will be reset at the same time DAILY INDOOR MIN AND MAX TEMPERATURE DISPLAY This temperature station shows the daily minimum and maximum indoor temperature in normal display IN J er C Ja us MAX er Min daily o LIE MIN eiali Max daily indoor temp indoor temp 66 Note The daily minimum temperature record
8. ERY CHANGE It is recommended to replace the batteries in all units regularly to ensure optimum accuracy of these units Battery life see Specifications below Please participate in the preservation of the environment Return used batteries to an authorized depot FUNCTION KEYS Temperature Station The Temperature Station has four easy to use function keys O CO SET key MIN Com CH key key SET key Manual Setting Press and hold to enter the setting mode for the following settings LCD contrast Time zone Atomic Time Reception RCC ON OFF 12 24 hr format Manual time Year Month Day and C F settings MIN MAX key To toggle between minimum maximum indoor and outdoor temperature records Press to exit the setting mode Press to reset the minimum and maximum or temperature records of the indoor and the outdoor channel will reset all records to current level key make a positive adjustment for various settings In normal display press to toggle between the display of the calendar data and second of time in the time display of LCD CH key To make a negative adjustment for various settings To toggle between different outdoor channel display when more than 1 outdoor transmitter is adopted 52 LCD SCREEN AND SETTINGS ii reception Time display 1 Indoo
9. WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time date indoor and outdoor temperature In addition the daily minimum and maximum indoor and outdoor temperature are shown in the normal display With only two keys this product is ideal for use in the home or office IT INSTANT TRANSMISSION 41 FEATURES The Temperature Station r Hanging hole c3 inn E Battery D compartment isplay hs s cover 05 m eas OUT or y C Lien m 185 2 iJ Foldout Stand 42 Atomic Time function DCF 77 Radio controlled time or manual time setting options Atomic Time reception On Off Hour and minute display Calendar display Time zone option 12 hours Wireless transmission at 868 MHz Outdoor signal reception intervals at 4 second Temperature display in degrees Celsius C or Fahrenheit F selectable Indoor and Outdoor temperature display with MIN MAX recording records can be reset Can receive up to 3 outdoor transmitters Daily minimum and maximum indoor temperature display Daily minimum and maximum outdoor temperature display Low battery indicator LCD contrast adjustable Table standing Wall mounting 43 The Outdoor Temperature Transmitter RT cof Remote transmission of outdoor
10. ccessful then at 04 00 and 05 00 and 06 00 there are other tries until one is successful If the reception at 06 00 is still not successful then the next try takes place at 02 00 next day Please refer also to notes on DCF 77 Radio Controlled Time and Manual Time Setting 48 BATTERY INSTALLATION INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION The Temperature Station uses 2 x AAA IEC LR3 1 5V batteries To install and replace the batteries please follow the steps below 1 Remove the cover at the back of the Temperature Station A 2 Insert batteries observing the correct polarity see marking 3 Replace compartment cover 49 INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER The temperature transmitter uses 2 x AAA IEC LR3 1 5V battery To install and replace the batteries please follow the steps below 1 Remove the battery compartment cover 2 Insert the batteries observing the correct polarity see marking 3 Replace the battery compartment cover Note In the event of changing batteries in any of the units all units need to be reset by following he setting up procedures This is because a random security code is assigned by the ransmitter at start up and this code must be received and stored by the Temperature Station in the first 3 minutes of power being supplied to it 50 BATT
11. e is plugged SETTING UP When one transmitter is used 1 First insert the batteries into the transmitter see Install and replace batteries in the Temperature transmitter below 2 Within 30 seconds of powering up the transmitter insert the batteries to the Temperature Station see Install and replace batteries in the Temperature Station below Once the batteries are in place all segments of the LCD will light up briefly Then the indoor temperature and the time as 0 00 will be displayed If they are not shown on LCD after 60 seconds remove the batteries and wait for at 45 least 60 seconds before reinserting them Once the indoor data is displayed user may proceed to the next step 3 After the batteries are inserted the Temperature Station will start receiving data signal from the transmitter 4 If the optional probe has been plugged to the dual channel transmitter the outdoor temperature should then be displayed on the Temperature Station on channel 1 and 2 Also the signal reception icon will be displayed If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 Note Channel 1 will show the reading from the internal sensor of the dual channel transmitter Channel 2 will show the reading sensed by the probe If the probe is not plugged to the transmitter will be shown on Channel 2 5 In order to ensure sufficient 868 MHz transmission the final po
12. eme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 0 to 59 9 C with 0 1 C resolution 32 F to 139 8 F with 0 2 F resolution OF L displayed if outside this range Outdoor 39 9 C to 59 9 C with 0 1 C resolution 39 8 F to 139 8 F with 0 2 F resolution OF L displayed if outside this range Indoor temperature checking interval every 15 seconds Outdoor data reception approximately every 4 seconds Power supply Temperature Station 2 x AAA IEC LR3 1 5 72 Temperature Transmitter 2xAAA IEC LR3 1 5V Battery life Alkaline batteries recommended Temperature Station Approximately 12 months Temperature Transmitter Approximately 12 months Dimensions L x W x H Temperature Station 95 x 18 8 x 136 mm Temperature Transmitter 41 x 19 x 128 mm LIABILITY DISCLAIMER The electrical and electronic wastes contain hazardous substances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local or and regional authorities to retrieve the addresses of legal dumping grounds with selective collection All electronic instruments must from now on be recycled User shall take an active part in the reuse recycling and recovery of the electrical and electronic waste The unrestricted dis
13. is reset automatically at 8 00 pm and the daily maximum temperature is reset automatically at 8 00 am every day DAILY OUTDOOR MIN AND MAX TEMPERATURE DISPLAY This temperature station also displays the daily minimum and maximum outdoor temperature for each outdoor channel in normal display OUT o Channel No 2 Li c Min daily temp Lt f Max daily tem of the channel 185 MIN M of the view the daily MIN and MAX temperature of another channel user shall press the CH key to shift to various channel display Note The daily minimum temperature record is reset automatically at 8 00 pm and the daily 67 maximum temperature is reset automatically at 8 00 am every day 868 MHz RECEPTION The Temperature Station should receive the temperature data within 5 minutes after set up If the temperature data is not received 5 minutes after setting up not successfully continuously the outdoor display shows please check the following points 1 The distance of the Temperature Station or transmitter should be at least 1 5 to 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning the Temperature Station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the same signal frequency 868MHz may prevent correct signal transmission and reception
14. mode by pressing the MIN MAX key TIME RECEPTION ON OFF SETTING Lj 5 flashing rr PLL In area where reception of the atomic time is not possible the time reception function can be turned OFF The clock will then work as a normal Quartz clock Default setting is ON 1 The digit ON and the time reception icon will start flashing on the LCD 2 Use the key or CH key to turn OFF the time reception function 3 Confirm with the SET key and enter the 12 24 Hour Display setting or exit the setting mode by pressing the MIN MAX key 58 Note If the Time Reception function is turned OFF manually the clock will not attempt any reception of the DCF time as long as the Time Reception OFF function is activated The Time Reception icon will not be displayed on the LCD 12 24 HOUR TIME DISPLAY SETTING gus 1 After setting time reception ON OFF press the SET key 12 h or 24 h flashes in the LCD default 24 h 2 Press the key or CH to select the 12 h or 24 h display mode 3 Press the SET again to confirm and to enter the Manual Time setting or exit the setting mode by pressing the MIN MAX key Note When 24 h mode display is selected the calendar format will be date and month display When 12 h mode display is selected the calendar format will be month and date display 59 MANUAL TIME SETTING In case the Temperature Station is not able to detect the Atomic time DCF signal
15. perature Station Note User must insert the batteries into the second transmitter within 30 seconds of reception of the first transmitter 6 The outdoor temperature reading from the second transmitter will be shown on the LCD and the Channel No will shift back to 1 indicating that all three channels are running successfully If this does not happen after 2 minutes the batteries will need to be removed from all the units and reset from step 1 47 Note After the Temperature Station has successfully received the second transmitter Channel 3 will display the data measured by the internal sensor of the second dual channel transmitter Yet the probe data from the second transmitter will not be displayed on the Temperature Station 7 Once the remote temperature has been received and displayed on the Temperature Station the DCF time code reception is automatically started This takes typically between 3 5 minutes in good conditions but may take up to 4 nights IMPORTANT Transmission problems will arise if the setting for additional transmitters is not followed as described above Should transmission problems occur it is necessary to remove the batteries from all units and follow the set up from step 1 If after 10 minutes the Atomic auto set time DCF time has not been received press the SET key to manually enter a time initially Daily DCF reception is done at 02 00 and 03 00 If the reception at 03 00 is not su
16. posal of electronic waste may do harm on public health and the quality of environment 73 As stated on the gift box and labeled on the product reading the User manual is highly recommended for the benefit of the user This product must however not be thrown in general rubbish collection points The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature and other weather data This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written authorization of the manufacturer E R amp TTE Directive 1999 5 EC Summary of the Declaration of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R amp TTE Directive 1999 5 EC 74
17. r Temperature Daily indoor 4 min temp Channel No Outdoor Sensor ID Outdoor signal reception icon Daily outdoor lor pt J min temp FEET ES Nase Ln L S mn COs 40 c Hs ri y El er F icon Weekday Day or Day Month or Second display Receiver low battery icon Daily indoor max temp ___ Outdoor Temperature Sensor low battery icon Daily outdoor max f Ht MAX 2 5 C ls 53 temp When the outdoor signal is successfully received by the temperature station this icon will be switched on If not successful the icon will not be shown in LCD So user can easily see whether the last reception was successful icon on or not icon off On the other hand the short blinking of the icon shows that a reception is currently taking place Note The Channel No Outdoor Transmitter No will be shown when more than one outdoor transmitter is adopted For better distinctness the LCD screen is split into 3 sections displaying the information for time and date Indoor data and outdoor data Section 1 TIME AND CALENDAR In normal mode display the time and weekday day Press the key once to display the day month twice to display the second of time A signal reception symbol is shown indicating that Atomic auto set time DCF time signal is received Section 2 INDOOR TEMPERATURE
18. sition between the Temperature Station and the transmitter should not be more than 100 meters see notes on Positioning and 868 MHz Reception 6 Once the remote temperature has been received and displayed on the Temperature Station the DCF time code reception is automatically started This takes typically between 3 5 minutes in good conditions but may take up to 4 nights When two transmitters are used 1 User shall remove all the batteries from the Temperature Station and transmitters and 46 wait 60 seconds if setting has been done with one transmitter before Insert the batteries into the first transmitter Within 30 seconds of powering up the first transmitter insert the batteries into the Temperature Station Once the batteries are in place all segments of the LCD will light up briefly Then the indoor temperature and the time as 0 00 will be displayed If they are not shown on the LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them The outdoor temperature readings from the first transmitter Channel 1 and 2 should then be displayed on the Temperature Station if probe sensor has been installed onto the first transmitter If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 Insert the batteries into the second transmitter as soon as the outdoor temperatures from the first transmitter are displayed on the Tem
19. to any interfering sources like computer monitors or TV sets is a minimum of 1 5 2 metres Within ferro concrete rooms basements superstructures the received signal is naturally weakened In extreme cases please place the unit close to a window and or point its front or back towards the Frankfurt transmitter MANUAL SETTINGS The following manual settings can be done in the setting mode LCD Contrast setting Time zone setting Atomic Time reception ON OFF setting RCC 12 24 hour time format setting Manual time setting Calendar setting Year Month Date C F temperature unit setting Press and hold the SET key for about 3 seconds to advance to the setting mode 56 LCD CONTRAST SETTING IL ri The LCD contrast be set to 8 different levels 0 to 7 to suit the user s needs default LCD contrast setting is LCD 4 To set the desired contrast level 1 The above display will be seen Press the key or CH key to select the level of contrast desired 2 Press the SET key to confirm and enter the Time Zone setting or exit the setting mode by pressing the MIN MAX key Lih flashing TIME ZONE SETTING flashing 57 The time zone default of the Temperature Station is 0 hr To change to another time zone 1 Using the key or CH key set the time zone The range runs between 12 to 12 hour 2 Press the SET key to confirm and enter the Time reception On Off setting or exit the setting