Home

TFA 30.3015 digital body thermometer

image

Contents

1. displayed if outside this range Humidity measuring range Indoor z 1 to 99 with 1 resolution displayed if outside this range Outdoor 1 to 99 with 1 resolution displayed if outside this range Indoor temperature checking intervals Every 15 seconds Indoor humidity checking intervals Every 20 seconds Outdoor temperature checking interval Every 5 minutes Outdoor humidity checking interval Every 5 minutes Transmission range up to 100 meters open space Maximum number of transmitters that can be used 5 Power consumption alkaline batteries recommended Temperature Station 3xAA IEC LR6 1 5V Transmitter 2xAA IEC LR6 1 5V Dimensions L x W x H Temperature Station 94x35x127 mm Transmitter purchased separately 75x55x164mm 92 LIABILITY DISCLAIMER The electrical and electronic wastes contain hazardous substances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local or and regional authorities to retrieve the addresses of legal dumping grounds with selective collection All electronic instruments must from now on be recycled User shall take an active part in the reuse recycling and recovery of the electrical and electronic waste The unrestricted disposal of electronic waste may do harm on public health and the quality of environment As stated on the gift box and labeled on the product
2. Also check if the battery has been used up User is recommended to use new alkaline batteries to the units There is a four minute time for user to set up all transmitters one by one after inserting batteries to the temperature station The below steps 2 to 4 shall be completed within this 4 minute time rA Insert batteries to the first transmitter The temperature station will start learning the transmitter The outdoor Channel 1 out 1 temperature and humidity readings will then be displayed User may observe the outdoor channel icon appear If this does not happen after 3 minutes the batteries will need to be removed from both units and reset from step 1 3 After the readings from the first transmitter Channel 1 are successfully shown by the temperature station insert batteries to the second transmitter The outdoor Channel 2 temperature and humidity readings will then be displayed User may observe the outdoor channel icon appear 4 Set up the third fourth and fifth transmitter if applicable one by one as described in the above steps 5 Please note that the unit s built in memory stores not only saved readings but also any integrated transmitters on their respective channels If after you start to use the unit not all transmitters are being received you can manually incorporate these one by one as described at LEARNING REMOVING A TRANSMITTER To free up a used channel for a new transmitter please proceed as described at
3. In normal cases there should be no reception problems within a 1500km radius of Frankfurt Once the outdoor reception test period is completed the DCF tower icon in the clock display will start flashing in the upper center This indicates that the clock has detected that there is a radio signal present and is trying to receive it When the time code is received the DCF tower becomes permanently lit and the time will be displayed If the tower icon flashes but does not set the time or the DCF tower does not appear at all then please take note of the following Recommended distance to any interfering sources like computer monitors or TV sets is a minimum of 1 5 2 meters A Within ferro concrete rooms basements superstructures the received signal is naturally weakened In extreme cases please place the unit close to a window and or point its front or back towards the Frankfurt transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possible in most cases A single daily reception is adequate to keep the accuracy deviation below 1 second 55 FUNCTION KEYS Temperature Station There are 5 function keys in the Temperature Station Plus key Gas OK key Mode key Y mode y al Alarm key L gt OK key 7 Minus key In normal display mode press and hold for 3 seconds to enter the manual setting mode for the following a LCD contrast level b Time zone c Daylight
4. point 4 You can also do this for all channels at the same time by returning to the factory settings as described at CLEARING ALL DATA AND SETTINGS OF THE TEMPERATURE STATION FROM THE PERMANENT MEMORY Please note that this will delete all stored data 6 The temperature station will also try to receive the DCF time signal radio controlled after the transmitter signal reception 54 Te If after 10 minutes the DCF time has not been received press and hold the OK v key for 3 seconds to enter the Set up mode for manual time setting The clock of the temperature station will automatically attempt to receive the DCF time at midnight When this is successful the received time will override the manually set time The date is also updated with the received time Please refer also to notes on Radio controlled Time Reception and Manual Setting DCF 77 RADIO CONTROLLED TIME The time base for the radio controlled time is a Cesium Atomic Clock operated by the Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than one second in one million years The time is coded and transmitted from Mainflingen near Frankfurt via frequency signal DCF 77 77 5 kHz and has a transmitting range of approximately 1 500 km Your radio controlled Temperature Station receives this signal and converts it to show the precise time in summer or wintertime The quality of the reception depends greatly on the geographic location
5. reading the User manual is highly recommended for the benefit of the user This product must however not be thrown in general rubbish collection points The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be reproduced without written authorization of the manufacturer 93 R amp TTE Directive 1999 5 EC Summary of the Declaration of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R amp TTE Directive 1999 5 EC 94
6. the temperature is higher than 30 0 or lower than 20 0 C 80 To set ds 2 3 the high humidity alarm In normal display press the Plus or Minus key to select a channel the sensor at the temperature station or one of the outdoor transmitters Press and hold the Alarm key for about 3 second to enter high humidity alarm setting The humidity digits high limit icon and the alarm icon will start flashing Press the Mode key to select to activate or deactivate the high humidity alarm Alarm On or Alarm Off icon will High limit icon Press the Plus or Minus key to set the desired Press OK key to return to the normal display or press the Alarm key to enter the low humidi alarm setting be displayed 2m T La bal al FE 50S e0 monn iiss Li Ut To set the low humidity alarm In normal display press the Plus or Minus key to select a channel the sensor at the temperature station or one of the outdoor transmitters t 81 wy Yo in L l Humidity digit m Aah mh tasting E Alarm On icon o se AI pai a ia i D al al i34ss mgm value of the high humidity alarm threshold point 7 Alarm Off icon y Press and hold the Alarm key for about 3 second to enter high humidity alarm setting Then press the Alarm key shortly one more time to enter the low humidity alarm setting The humidity digits low limit icon and the alarm icon wil
7. to reset Min Max record of all channels 57 Alar m key al Press and hold for 3 seconds to enter the alarm setting mode In alarm setting mode press to toggle between the following settings Ny high humidity alarm 2 low humidity alarm 3 high temperature alarm 4 low temperature alarm In manual setting mode press to go back to normal display mode 58 LCD Screen The LCD screen is split into 4 sections displaying the relatively humidity temperature EPROM status and Time Date Outdoor data signal reception indicator Outdoor transmitter identification number Data recording interval Time Time reception icon 4 for DCF time 2 out T AN at ot Ct ot B m AAU CE n m TE Low battery indicator a 04 ob 59 rec UGGS hremin mem uE Relative humidity reading in RH Temperature reading in C F Memory data display showing no of sets of unread data stored in memory Calendar display Buzzer on icon MANUAL SETTINGS In normal display mode press and hold the OK key for 3 seconds to enter the manual setting mode for the following LCD contrast setting Time zone setting Daylight saving time On Off setting Radio controlled time reception On Off setting 12 24 hour format setting Time setting Hour and Minute Calendar setting Year Month and Day Temperature unit C F s
8. transmission range is around 100 meters from the Temperature transmitter to the Temperature Station in open space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see SETTING UP above 89 POSITIONING THE TEMPERATURE STATION The Temperature Station provides the option of table standing or wall mounting the unit Before wall mounting please check that the outdoor temperature s can be received from the desired location s To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out by about 5mm 2 away from the base and hang the station onto the screw Remember to ensure that it locks into place before releasing POSITIONING THE OUTDOOR TEMPERATURE TRANSMITTER The Outdoor Transmitter is supplied with a holder that may be attached to a wall with the screws supplied To attach to the wall using screws please follow the steps below ds Mark the wall using a pen through the holes in the holder to obtain the exact drilling position 2 Drill holes in the wall at the points marked 3 Screw holder onto wall fH Oi ona is 90 The mounting surface can affect the transmission range If e g the unit is attached to a piece of metal it may either reduce or increase the transmitting range For this reason we recommend not placing the unit on any m
9. value displayed for particular channel will be calculated from only the new data being recorded after battery change 76 d The dew point temperature a CFE td Dew point temperature icon wy wy rv C AL 3 G0 05 he min aco i345 sige In normal display mode press the mode key four times The dew point temperature will be displayed next to the flashing td icon 77 e The history data sets of temperature and humidity n D r PE rh ER _ History data icon flashing ERE y o ILI o l t E3 00 05 nr min Ged HIO mwy In normal display mode press the mode key five times The hist icon will be flashing and the last recorded temperature and humidity reading with the time of record will be displayed By pressing the key the previous sets of readings which were measured at the user selected recording intervals may be viewed If the channel is not set to be saved in the system memory no history values will be displayed and will be shown on LCD 78 CALIBRATION OF TEMPERATURE AND HUMIDITY READING The temperature station allows user to calibrate the displayed temperature and humidity readings by a better reference User may enter the correction of temperature reading and humidity reading in the range of 2 C and 10 respectively To calibrate the humidity reading 1 Press the Plus or Minus key to select a channel the sensor at the temperature station or
10. ATTERY CHANGE User shall replace batteries of the temperature station when the battery low indicator is displayed at the LCD If user does not replace batteries working error may be resulted Note After changing batteries in temperature station there is no need for user to reset the temperature station In fact the temperature station can remember all transmitter information and sequence as per the pervious set up However user may require to reset the desired LCD contrast Alarm On Off condition Calibration value and the Clock by re entering the date and time manually or simply wait for the DCF time signal The Average value display for particular channel will only be calculated from the data after battery change It is recommended to replace the batteries in all units on an annual basis to ensure optimum accuracy of these units Please participate in the preservation of the environment Return used batteries to an authorized depot E SETTING UP i Insert batteries into the Temperature station see How to install and replace batteries in the Temperature above Once the batteries are in place all segments of the LCD will light up briefly Then the indoor temperature and humidity will be displayed The time will be shown 0 00 and the date as 1 1 04 53 Note If the indoor temperature and humidity are not displayed after 15 seconds remove the batteries and wait for at least 2 minutes before reinserting them
11. DCF icon will not be displayed on the LCD 64 12 24 HOUR FORMAT SETTING IC cur j Digits flashing 00 05 nmin GEM A 16 1J The time display can be selected to show hours in 12 hour or 24 hour settings Default 24 Hour 1 2 3 4 Press and hold the OK key until the digits Lcd starts flashing Press and release the OK key four times to enter the time format setting The digit 24h will be flashing Use the Plus and Minus key to set the time shown in 12 hour or 24 hour format Press the Mode or Alarm key to confirm and go back to the normal display mode 65 MANUAL TIME SETTING In case the Temperature Station cannot detect the DCF signal for example due to disturbances transmitting distance etc the time can be manually set The clock will then work as a normal Quartz clock cr in m al Lal rh ay pu ayo Tt La Lal m C 28 G0 0Shrmin EERO G 6 Hour flashing UA so 4m 1 04 Minutes flashing 1 Press and hold the OK key until the digits Lcd starts flashing 2 Press and release the OK key five times to enter the hour setting The hour digit in the time LCD will be flashing 3 Use the Plus and Minus key to set the hour 4 Press the OK key one more time to confirm the hour and advance to the minute setting The minute digit will be flashing 5 Use the Plus and Minus key to set the minute 6 Press the Mode or Alarm key to confirm and go back to the normal displa
12. OK key eleven times to enter minute setting of the recoding interval The min in the record LCD will be flashing Use the Plus and Minus key to set the desired recording interval Press the Mode or Alarm key to confirm and go back to the normal display mode LEARNING REMOVING A TRANSMITTER CHANNEL After replacement of batteries of a particular transmitter it is necessary to learn the transmitter again in the learning mode On the other hand when user want to decrease the number of transmitters to be applied he may remove the transmitter so that the data from this channel will not be displayed in the temperature station The below procedures describe how to re learn or remove a channel 1 2 Press and hold the OK key until the digits Lcd starts flashing Press shortly the OK key twelve times to enter Learn Remove setting of channels The digits Lrn CH and the channel icons will be flashing L rT m Digit flashing Flashing ___ ro LH GE OShrsmin HEJ He iso 2mm 70 Press Plus to get in Learn Remove setting of channels The channel icon 1 will be flashing Press OK key v to select another channel if necessary 1 5 Press Plus to set the selected channel to Re learn state The channel icon will flash in two places on the display or press Minus to remove the channel The channel icon will disappear 6 As soon as the in two places flashing channel number d
13. TTER PURCHASED SEPARATELY The range of the Temperature transmitter may be affected by the temperature At cold temperatures the transmitting distance may be decreased Please bear this in mind when positioning the transmitters Also the batteries may be reduced in power for the Temperature transmitter 88 CHECKING FOR 433MHz RECEPTION If the outdoor temperature data is not being received within three minutes after setting up or outdoor display show in the outdoor section of the Temperature Station after 3 failed attempts during normal operation please check the following points T The distance of the Temperature Station or transmitters should be at least 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid placing the transmitters onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the 433MHz signal frequency may prevent correct signal transmission or reception Neighbors using electrical devices operating on the 433MHz signal frequency can also cause interference Note When the 433MHz signal is received correctly do not re open the battery cover of either the transmitter or Temperature Station as the batteries may spring free from the contacts and force a false reset Should this happen accidentally then reset all units see SETTING UP above otherwise transmission problems may occur The
14. WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION Congratulations on purchasing this revolutionary 433MHz temperature Station which provides advanced data logging and data analysis functions for up to five outdoor temperature readings The temperature station is connectable to PC by the COM port and data importing to PC is allowed By applying the smart software provided user may perform data analysis and statistics conveniently in PC With easy to use keys this innovative product is ideal for home and professional usages FEATURES The Temperature Station 7 GS Hanging Hole LCD screen Battery Compartment Function keys A J Foldout stand eee C2 LN Cable socket to PC 49 DCF radio controlled time with manual setting option Time zone option 12 hours Indoor and outdoor temperature display with MIN MAX records and time of reception Indoor and outdoor humidity display as RH with MIN MAX records Data logging function with adjustable recording intervals can store up to 3000 sets of Temperature Humidity data Connectable to PC Com port data can be transferred to PC with the software in CD ROM provided Can receive up to 5 outdoor transmitters Time reception ON OFF selectable Dew point temperature displayed Temperature amp humidity High Low alarm function 12 24 hour time display Year Month Day calendar
15. channel No 1 and 2 will be saved in the system memory Similarly if user set Enr 4 data from channels No 1 to 4 will be saved On the other hand if user has initially applied 5 transmitters but then remove the Channel 3 the temperature station will thereafter display for Channel 3 And if the user has chosen Enr 3 then data from Channel 1 to 3 will be stored in the memory instead of Channel 1 2 and 4 The data stored in the memory for channel 3 will be After the Enr number has been changed the history data will be cleared and mem will be rest to 000 TO EXIT THE MANUAL SETTING MODE Press the Mode key or Alarm key to exit the manual setting mode anytime during the manual setting The mode will return to the normal time display 72 TOGGLING BETWEEN DIFFERENT CHANNELS INDOOR AND OUTDOOR CHANNELS Press the Plus or Minus key to toggle between the Temperature and humidity readings of the 1 indoor channel and the outdoor transmitter channel s The channel identification icon n out 1 out 2 out 3 will be displayed at the upper right screen indicating that the particular channel is now being selected The temperature and humidity readings of Outdoor transmitter No 2 is now shown Lot SL A am rh T e A l ampm dst alm 73 VIEWING VARIOUS TYPE OF TEMP HUMDITY READINGS OF A SELECTED CHANNEL A
16. d history data will no longer exist The memory display will show mem 000 after the data has been cleared Note The maximum minimum temperature and humidity data will not be cleared CLEARING ALL DATA AND SETTINGS OF THE TEMPERATURE STATION FROM THE PERMANENT MEMORY FACTORY RESET The factory reset needs to be launched if malfunction on the temperature station occurs To reset the temperature station Ak Ensure that the unit is in normal display not displaying max min or history And the unit is not making any DCF or HF reception 2 Press the OK Plus Minus and Mode key and hold for 3 seconds in following orders The OK key must be pressed and hold first then the other three key must be pressed and hold also within 1s Then hold the four keys for 3 seconds until you see running digits at bottom right area of LCD Note If the reset is not successfully initiated user shall try from above step 1 again 85 Press and hold OK key first lt a OK s Immediately press these___ 3 keys at the same time mode Then hold the 4 keys together for about 3 seconds 3 The running digits will be displayed for about 6 minutes followed by the full segment display User is then required to remove and re insert batteries to complete the restart the unit Note All data in temperature station will be cleared after the factory reset The permanent memory of the temperature station will be reset and all the data of all channel
17. display Temperature display in C F LCD contrast selectable Temperature and humidity calibration function Low battery indicator Table standing or wall mounting 50 The Outdoor Temperature Transmitter purchased seperately HOW TO IN The Tempera follow the steps below tinaaaaa Remote transmission of outdoor temperature and humidity to Temperature Station by 433 MHz Shower proof casing Wall mounting case Mounting at a sheltered place Avoid direct rain and sunshine linnaan STALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION ure Sta ion uses 3 x AA IEC LR6 1 5V batteries To install and replace the batteries please lk Insert finger or other solid object in the space at the bottom center of the battery compartment and lift up to remove the cover Zt Insert batteries observing the correct polarity see marking 3 Replace compartment cover 51 HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER The Outdoor Temperature transmitter uses 2 x AA IEC LR6 1 5V batteries To install and replace the batteries please follow the steps below 1 Inopaanaal Battery compartment 2 3 Remove the battery cover at the front side with an appropriate screwdriver Insert the batteries observing the correct polarity see battery compartment marking Replace the battery cover on the unit 52 B
18. etal surfaces or in any position where a large metal or highly polished surface is in the immediate proximity garage doors double glazing etc Before securing in place please ensure that the Temperature Station can receive the signal from the Outdoor Temperature transmitter at the positions that you wish to situate them CARE AND MAINTENANCE Extreme temperatures vibration and shock should be avoided as these may cause damage to the units and give inaccurate forecasts and readings When cleaning the display and casings use a soft damp cloth only Do not use solvents or scouring agents as they may mark the LCD and casings Do not submerge the units in water Immediately remove all low powered batteries to avoid leakage and damage Replace only with new batteries of the recommended type Do not make any repair attempts to the units Return it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy 91 SPECIFICATIONS Temperature measuring range Indoor n 9 9 C to 59 9 C with 0 1 C resolution 14 F to 139 8 F with 0 2 F resolution displayed if outside this range Outdoor 29 9 C to 69 9 C with 0 1 C resolution 21 8 F to 157 8 F with 0 2 F resolution
19. etting Recording intervals to memory hr min Relearning or removing a transmitter Number of sets of outdoor channel to be saved to memory of temperature station ATU sTeaseaogD 60 LCD CONTRAST SETTING cd 5 i234s6 oag j Digits flashing The LCD contrast can be set within 8 levels from LCD 0 to LCD7 Default setting is LCD 5 1 2 3 In normal display press and hold the OK v key until the digits Lcd starts flashing Use the Plus and Minus key to view all levels of contrast Select the desired LCD contrast Confirm with the mode or Alarm al key to go back to the normal display mode 61 TIME ZONE SETTING ha al m1 Lal 28 05 05 nremin EE 2 E i2 34s5 io i984 a Digits flashing The time zone default of the Temperature Station is 0 To set a different time zone 1 2 3 4 Press and hold the OK key until the digits Lcd starts flashing Press shortly the OK key one more time to enter the time zone setting The digits Zo will be flashing Use the Plus and Minus key to set the time zone 12 to 12 hr Press the Mode or Alarm key to confirm and go back to the normal display mode 62 DAYLIGHT SAVING TIME SETTING Cc dh Digits flashing E 08 05 hrmin GE 2 16 Te Press and hold the OK key until the digits Lcd starts flashing 2 Press shortly the OK key two times to enter
20. fter a particular channel the indoor sensor or one of the outdoor transmitters has been selected by pressing the Plus or Minus key the following modes of data may be viewed by user a The Max temperature and Max humidity cor in l E rh Max icon flashing ERA ae Cat 1 6649n eau ig 00H In normal display mode press the mode key once The maximum temperature and maximum humidity measured by the channel and the date and time of the maximum temperature recorded will be displayed The max icon will be flashing 74 b The Min temperature and Min humidity es ie i t min mir LILI E 08 05 hr min GE CO fee any 15 7 Min icon flashing In normal display mode press the mode key two times The minimum temperature and humidity measured by the channel and the date and time of the minimum temperature recorded will be displayed The min icon will be flashing c The average value of the last 100 sets reading Wieg 49 rh Average icon flashing mm r bee A i JHs wie In normal display mode press the mode key three times The average temperature and humidity value of the data which have been saved in the system memory will be displayed The avg icon will be flashing If the channel is not set to be saved in the system memory no average value will be estimated and will be shown Note The Average
21. idity is back to the conditions within the preset threshold values 83 ig ig go Alarm signal icon __ l appears as the Li l current temperature e Cc or humidity is out of O05 hr min PE the pre set l Z threshold value J455 io py CLEAR DATA IN THE TEMPERATURE STATION CLEARING THE MAX MIN TEMPERATURE AND HUMIDITY DATA OF A PARTICULAR CHANNEL To clear the max min data of a channel 1 Press the Plus or Minus key to select a channel 2 Press and hold the Mode key for 3 second The maximum and minimum temperature humidity data and the time of record will be reset to the current value CLEARING THE MAX MIN TEMPERATURE AND HUMIDITY DATA OF ALL CHANNELS To clear the max min data of all channels 84 lis Press and hold the Mode key for 5 second The maximum and minimum temperature humidity data and the time of record will be reset to the current value CLEARING ALL STORED TEMPERATURE AND HUMIDITY DATA FROM TEMPORARY MEMORY OF THE TEMPERATURE STATION The on going temperature and humidity data are stored at the ring buffer memory a temporary memory area where the latest data will displace the oldest data once the memory capacity is reached To clear this memory the following step shall be performed 1 Press both the Plus key and OK key and hold for about 2 seconds Only the temperature and humidity records of all channels indoor and the outdoor channels will be cleared So the average an
22. isappears the reception icon will be flashing in the top left corner Insert the batteries in the respective transmitter After a short time 1 minute at the maximum the transmitter should be linked 7 Repeat the above steps for further channels if necessary OP pa Note Once a channel is removed the temperature station will be disconnected form the channel and the data transmitted by this channel cannot be viewed at the temperature station THE NUMBER OF OUTDOOR TRANSMITTERS TO BE SAVED INTO THE SYSTEM MEMORY Digits flashing inn REO E Me tsa B004 71 Up to 5 outdoor transmitters can be received by the temperature station User may decide the number of transmitter data to be save to the permanent memory of the temperature station For instant user may apply 5 transmitters but set to save the data only from particular 3 transmitters To set the number of transmitters whose data are to be saved in the system memory 1 Press and hold the OK key until the digits Lcd starts flashing 2 Press and release the OK key thirteen times to enter transmitter number setting The digit Enr will be flashing 3 Use the Plus and Minus key to select the number of transmitter to be used with the temperature station up to 5 transmitters 4 Press the OK key one more time to confirm and go back to the normal display mode Note A If user has set Enr 2 and five transmitters are on the data only from
23. key three more times to enter the low temperature Alarm setting The temperature digits low limit icon and the alarm icon will start flashing 82 3 Note Press the Mode key to select to activate or deactivate the low temperature alarm Alarm On or Alarm Off icon will be displayed Press the Plus or Minus key to set the desired value of the low temperature alarm point Press OK key to return to the normal display The alarm allow user to set individually the high or low threshold upon his requirements For example the user can set the thresholds for temperature to 35 C high and 25 C low while only activating high temp alarm and deactivating low temp alarm In this case the alarm will not trigger when temp is lower than 25 C yet will trigger when temp is higher than 35 0 C When the temperature or humidity is sensed to be out of the pre set threshold value the alarm will sound and the alarm icon will be present on LCD User may press any key to stop the buzzer If no key is pressed the buzzer will beep for two minutes yet the alarm signal icon will still be flashing until the temperature or humidity is within the pre set range again Once an alarm is triggered the display switches to the latest triggered channel In addition the high low limit icon and IN OUT icon is flashing as long as the alarm condition is met If an alarm is triggered the alarm icon will be flashing until the temperature and hum
24. l start flashing Press the Mode key to select to activate or deactivate the low humidity alarm Alarm On or Alarm Off icon will be displayed Press the Plus or Minus key to set the desired value of the low humidity alarm point Press OK key to return to the normal display or press the Alarm to enter the high temperature alarm setting To set the high temperature alarm 1 2 In normal display press the Plus or Minus key to select a channel the sensor at the temperature station or one of the outdoor transmitters Press and hold the al key for about 3 second to enter high humidity alarm setting Then press shortly the Alarm key two more times to enter the high temperature alarm setting The temperature digits high limit icon and the alarm icon will start flashing Press the Mode key to select to activate or deactivate the high temperature alarm Alarm On or Alarm Off icon will be displayed Press the Plus or Minus key to set the desired value of the high temperature alarm point Press OK key to return to the normal display or press the Alarm to enter the low temperature alarm setting To set the low temperature alarm 1 2 In normal display press the Plus or Minus key to select a channel the sensor at the temperature station or one of the outdoor transmitters Press and hold the Alarm key for about 3 second to enter high humidity alarm setting Then press shortly the Alarm
25. one of the outdoor transmitters Press shortly the mode key for six times The calibration icon will be flashing Press the ok key once The humidity digits will be flashing rr in J 1 Humidity correction flashing Lt 2 3 rarer LIL OE 85 pr min GE G28 H gig Calibration icon flashing 4 Press the Plus or Minus key to set the desired correction for the humidity reading Then press the Alarm key to exit or the OK key to advance to the calibration of temperature reading 79 To calibrate the temperature reading aks Press the Plus or Minus key to select a channel the sensor at the temperature station or one of the outdoor transmitters rA Press shortly the Mode key for six times The calibration icon will be flashing 3 Press shortly the OK key two times The temperature digits will be flashing we in Lt o u o 9 cy heal ener a correction i Lf flashing EA C005 nr min MEN GE i amp JHss sige B Calibration icon flashing 4 Press the Plus or Minus key to set the desired correction for the humidity reading Then press the Alarm key to exit ALARM PROGRAMMING FOR INDOOR OUTDOOR TEMPERATURE AND HUMIDITY The weather station will allow users to set a range of specific alarms to meet specific temperature and humidity conditions set by the user For example user may set the high and low temperature alarm point at 20 and 30 C respectively Then the alarm will sound once
26. s stored Also all the previous settings of the station including the date and time alarm calibration settings will be cleared 86 HEED SLLALLAD 123 5 max min avghhist hist AB Fr aa hr min n O gA BBB ae iii Ba 87 m The display will show some running digits when the temperature station is reset Full segment will be displayed user need to remove and re insert batteries to restart the temperature station After batteries are re inserted the station will automatically launch the learn mode The signal receipt indicator will be displayed User needs to set again the temperature station for the desired application See SETTING UP in previous clause Note If the battery level is low the digits No EPr may be displayed on LCD after resetting indicating that the power is too low for the temperature station to function normally In this case the batteries shall be replaced User is recommended to upload and save all the useful data to PC if possible before performing the factory reset USING THE TEMPERATURE STATION WITH PC With the aid of the software supplied the temperature station may provide the following additional functions to user 1 Importing data from temperature station to PC 2 Printing the history file Procedures to install the software to PC and application of the software are described in the user manual of the PC software ABOUT THE OUTDOOR TRANSMI
27. saving time On Off d Radio controlled time reception On Off e 12 24 hour Display f Time setting Hour and Minute g Calendar setting Year Month and Day h Temperature unit C F setting 56 i j k Recording intervals to memory hr min Re learning Removing channels Number of channels to be saved to memory In view mode or alarm mode press to go back to normal display mode Plus and Minus key In normal display mode press to select a channel the indoor sensor or one of the outdoor transmitters Press to make adjustment increase or decrease in different manual settings and alarm setting Mode key mode In normal display mode press to toggle between the following view mode a Maximum record of a selected channel the indoor sensor or one of the outdoor transmitters depending on the user s selection b Minimum record of a selected channel Cc Average humidity and temperature readings of a selected channel over the last 100 values stored in memory d The dew point temperature of a selected channel e History readings in the memory of a selected channel f Calibration mode of humidity and temperature of a selected channel In alarm setting mode press to activate deactivate the temperature and humidity alarm In manual setting mode press to go back to normal display mode Press and hold for 3 seconds to reset Min Max record of a particular channel Press and hold for 5 seconds
28. the daylight saving time setting The digit dS will be flashing 3 Use the Plus and Minus key to set the daylight saving time function to On or Off mode 4 Press the Mode or Alarm key to confirm and go back to the normal display mode Note The function of day night time saving is only applicable to WWVB time reception within the areas in the United States dS off means that the feature is off and the WWVB will not change times automatically dS On indicates that the feature is on and the WWVB will change times automatically 63 TIME RECEPTION ON OFF SETTING g ree 7 ue 25 0005 irmn BETO E i JHss iag t Digits flashing In area where reception of the DCF time is not possible the DCF time reception function can be turned OFF The clock will then work as a normal Quartz clock Default setting is ON As Press and hold the OK key until the digits Lcd starts flashing 2 Press and release the OK key three times to enter the time reception time setting The digit rEc will be flashing 3 Use the Plus and Minus key to set the time reception function to on or off mode 4 Press the Mode or Alarm key to confirm and go back to the normal display mode Note If the Time Reception function is turn OFF manually the clock will not attempt any reception of the DCF time as long as the Time Reception OFF function is activated The time reception icon and the
29. y ci Digit flashing et A mmy CUJ mnnn mem TA GEES hr min ai Me fsa emy The temperature display can be selected to show temperature data in C or F Default C 1 2 3 4 Press and hold the OK key until the digits Lcd starts flashing Press and release the OK key ten times to enter the temperature unit setting The C digit will be flashing Use the Plus and Minus key to set the unit of temperature in C or F Press the Mode or Alarm key to confirm and go back to the normal display mode 68 RECORDING INTERVAL hr min SETTING a Ce l l m mur Digits flashing mie c rec AREA Teme A esr Lee ig IoD The time intervals at which the temperature and humidity data saved to memory can be set to one of the following 1 minute 5 minute 10 minute 15 minute 20 minute 30 minute 1 hour 2 hour 4 hour 6 hour 8 hour 12 hour or 24 hour Your appliance has been developed and produced to the very latest technical standards Unfortunately however an error occurred in programming the time intervals The following intervals are out of line as follows 3 hour interval Records every 4 hours 4 hour interval Records every 6 hours 6 hour interval Records every 8 hours 8 hour interval Records every 12 hours 12 hour interval Records every 24 hours 69 2 3 4 Press and hold the OK key until the digits Lcd starts flashing Press and release the
30. y mode 66 Note The unit will still try and receive the signal every day despite it being manually set When it does receive the signal it will change the manually set time into the received time During reception attempts the DCF tower icon will flash If reception has been unsuccessful then the DCF tower icon will not appear but reception will still be attempted the following hour CALENDAR SETTING rs O in Z N 1 h l Li th a et C T EA CE 05hrmin a Hg lso 12 wout year Date Month The date default of the Temperature Station is 1 1 in the year 2004 Once the radio controlled time signals are received the date is automatically updated However if the signals are not received the date can also be set manually 1 Press and hold the OK key until the digits Lcd starts flashing 2 Press and release the OK key seven times to enter the year setting The year digit in the date LCD will be flashing 3 Use the Plus and Minus key to set the year 67 Press the OK key one more time to confirm the year and advance to the month setting The month digit will be flashing Use the Plus and Minus key to set the month Press the OK key one more time to confirm the month and advance to the day setting The day digit will be lashing Use the Plus and Minus key to set the day Press the Mode or Alarm key to confirm and go back to the normal display mode TEMPERATURE UNIT SETTING C F z