1. S2 BIT1 ON and BIT2 OFF to receive security code via Pin2 of P4 DB9F BIT1 OFF and BIT2 ON to receive security code via Pin3 of P4 DB9F BIT3 OFF and BIT4 ON for dedicated RS 232C BIT3 ON and BIT4 OFF for non dedicated RS 232C denotes factory default setting CR4004 4104 4214 1 Open the PC case Put the metal bracket with power connector into one of the I O windows 2 Connect the cable to the HDD type power connector of PC power supply See illustration below Then close the PC case f 3 Connect the DB 9 connector to the POWER CORD computer s serial port of COM1 or d COM2 Connect the 4P phone plug connector to the added I O bracket See below illustration 616P PHONE JAC POSIFLEX 4PIN PHONE JACK CR4005 4105 4215 CR4005 II 4105 II 4215 11 1 Define a drawer number for the cash drawer so that this cash drawer is going to respond accordingly in USB communication Follow the table below for SWITCH SETTING to adjust the switch S1 according to this drawer number if it is not 7 Please note that within each system there should never be any 2 USB interface cash drawers carrying the same drawer number O a 3 2 Rear View r k k k Connect to USB AC es I P Port of Main PC Power Jack of CR4005 4105 4215 USB Connector from CR4005 4105 CR4005 II 4105 II 4215 II 4215 CR4005 II 4105 I 4215 I Rear View of Model CR4005 4105 4215 CR4005 IT 4105 II 4215 II C
2. Wire color Function Drawer open sense Drawer open sense return 24V to solenoid Drawer kick pulse POUSIFLEX b For CR4001 4101 4211 4002 4102 4212 CCBLA 196A with one 9PM and one 9PF connector c For CR4003 4103 4213 CCBLA 089 1 with one 25PM and one 25PF connector d For CR4004 4104 4214 The serial signal cable is already built on e For CR4005 4105 4215 CR4005 II 4105 II 4215 I USB cable is already built on 6 Power Source depend on model a For CR 4000 4100 4210 not applicable b For CR 4001 4101 4211 4002 4102 4212 4003 4103 4213 4005 4105 4215 CR4005 II 4105 II 4215 II Power adapter 12VAC 1 5A c For CR4004 4104 4214 Power connector cable and I O bracket plate INSTALLATION CR4000 4100 4210 Connect the drawer to POS system printer as shown below Rear View 8P Telephone Plug POS System or Printer g Output to drawe Control signal input 8P Telephone Jack CASH DRAWER With Printer Interface CR4001 4101 4211 6P Telephone Plug 1 Connect the drawer serial I P port to the computer COM port Connect the power adapter output to the Power Input jack 2 No other RS232C devices should be connected to the serial O P port 3 Set position 3 of S2 to OFF and position 4 of S2 to ON Please refer to rear panel illustration CR4002 4102 4212 1 Connect the drawer serial I P port to the computer COM port Connect the power adapter o
3. POSIFLEX lt CR 4000 SERTES CASH DRAWER USER S MANUAL Rev C NOTICE The manufacturer of the POS cash drawer makes no representation or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties of fitness for a particular purpose or for any indirect special or consequential damages Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer FCC NOTICE This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference CE P N 19240901021 POSIFLEX MODEL NUMBERS Model CR400X CR410X CR421X Bill Compartment 5 Adjustable 5 Fixed 5 Fixed Bill clip Plastic Metal Metal Coin compartment 9 Fixed 9 Fixed 5 Fixed Coin Roll storage 1Undern
4. ash Drawer with USB Interface SWITCH SETTING Drawer 0 1 2 3 4 5 6 7 SW1 ON OFF ON OFF ON OFF ON OFF SW2 ON ON OFF OFF ON ON OFF OFF SW3 ON ON ON ON OFF OFF OFF OFF SW4 Reserved Default setting Drawer 7 SW1 OFF SW2 OFF SW3 OFF 2 Connect USB connector of cable coming out from the rear side of the USB interface cash drawer to USB port of main PC 3 Check the specification of power adaptor on its nameplate Insert the power adaptor into the correct power outlet Insert the output plug to the jack at rear side of CR4005 4105 4215 CR4005 II 4105 II 4215 II to supply power for drawer kickout 4 Install the USB utility driver from Posiflex Product Information CD with Posiflex POS system or visit our web sites http www posiflex com tw or http www posiflextw com or http www posiflexusa com for latest updates 5 POSIFLEX UPOS driver application Applied for all Posiflex cash drawer Please first find in Posiflex Product Information CDROM or download from Posiflex web sites for UPOS driver setup In this application CR4XX3 and CR4XX4 respond to openDrawer command only CR4XX0 CR4XX1 and CR4XX2 are compliant to UPOS version 1 4 CR4XX5 are compliant to UPOS version 1 7 and CR4XX5 II are compliant to UPOS version 1 8 FUNCTIONAL TEST CR4000 4100 4210 1 Follow the printer s manual of the printer the cash drawer is connected
5. com tw or www posiflextw com or www posiflexusa com for USB Cash Drawer Test Program If you use the Posiflex Product Information CDROM that comes with any Posiflex POS system please go to folder Drivers CR USB and click SETUP EXE to install the USB Cash Drawer Test Program POSIFLEX 2 Start up the test program and click STATUS button The drawer status of Open Close or Not present will be displayed under each drawer number as O C or N 3 Use a key to turn the lock to standby position the one marked with sign at middle click the check only the box es under the drawer number s for the drawer s to be tested then click the KICK button 4 The cash drawer will then open and the Open Close Not present status of the tested drawer number will be renewed accordingly If these status are correct the USB interface cash drawer passes the test SPECIFICATIONS MECHANICAL Dimensions 428 W x 460 D x 100 H mm Weight 6 0 Kgs Removable tray with a lock on cover option ELECTRICAL Power Source Solenoid Drive for CR 4000 4100 4210 Pulse Amplitude 12 to 24 VDC Pulse Width 100 to 250 msec Pulse Duty Cycle 10 max Max Current Consumption 0 75A 12 VDC 1 5A 24 VDC AC Adaptor for CR 4001 4101 4211 4002 4102 4212 4003 4103 4213 4005 4105 4215 4005 I 4105 II 4215 II Input Voltage 120 VAC 10 240 VAC 10 50 60 Hz Output Voltage 12 VAC at 1 5 A DC Power K
6. eath Cash Tray 4 Behind Cash Tray INFERFACE APPLICATION Model Number Interface Security Power Source Code CR 4000 4100 4210 Printer drive N A 12 24 V Pulse Printer CR 4001 4101 4211 Dedicated RS232 serial N A CR 4002 4102 4212 Non dedicated RS232 serial 0 255 12VAC Adaptor CR 4003 4103 4213 Parallel 0 255 CR 4004 4104 4214 Dedicated RS232 serial N A 12VDC PC CR 4005 4105 4215 USB USB PID 12VAC Adaptor CR 4005 II 4105 II 4215 I USB USB PID 12VAC Adaptor CARTON CONTENTS 1 Cash drawer pre assembled 2 User s manual 3 Separators of bill compartment 4 pcs for CR4000 5 and CR4005 II only 4 Key 2pcs There is a key serial No sticker on the cash drawer bottom plate If user lost the key he she can order the key according to this number 5 Signal Cable depend on model a For CR4000 4100 4210 The standard signal cable is CCBLA 180 or CCBLA 180 1 which has a 8 pin plug at one end to connect to the cash drawer and a 6 pin plug at the other end to connect to the POS system printer This cable serves for most popularly used POS equipment such as all Posiflex POS terminals all Posiflex POS printers most Epson POS printers most Star POS printers and all other compatibles The user may cut the 6 pin end or order the ready cut cable CCBLA 180A and assemble this free end according to his POS printer specification if the POS printer used applies different connection The cable connection on CCBLA 180A is as below
7. it for CR 4004 4104 4214 12 V DC and 5 V DC Interface Direct Drive CR4000 4100 4210 Serial RS232C CR 4001 CR 4002 CR 4004 CR 4101 CR 4102 CR 4104 CR 4211 CR 4212 CR 4214 Baud rate 9600 9600 150 19200 Parity None none none even or odd Data Bits 8 8 7or 8 Stop Bits lor2 lor2 lor2 Parallel IEEE1284 CR 4003 4103 4213 USB 1 1 CR 4005 4105 4215 4005 II 4105 II 4215 II POSIFLEX Security Code CR 4002 4102 4212 4003 4103 4213 1 255 factory preset value 7 CR 4005 4105 4215 4005 II 4105 II 4215 II USB PID Drawer Open Sense CR 4000 4100 4210 Drawer open sense circuit shorts when open CR 4001 4101 4211 4002 4102 4212 Pin 9 shorts to pin 5 when drawer open CR 4005 4 105 42 15 4005 I1 4105 I1 4215 I Through USB driver KEYLOCK OPERATION Physically lock the drawer 3 Open the drawer by the key Automatically open the drawer by POS printer or POS system or interface signal control Keylock STRUCTURE Check Slot Inside CR 4000 4001 4002 4003 4004 4005 4005 II 4100 4101 4102 4103 4104 4105 4105 II Bill compartment Bill Clip Ee _ _ A SC a ee A 3 m UTN a a Coin compartment Cash Tray Coin Roll Storage Tray for CR 4210 4211 4212 4213 4214 4215 4215 II Bill compartment Coin Roll Storage Cash Tray A Se Bill Weight Coin compartment
8. to open cash drawer 2 If the cash drawer is connected to a Posiflex POS system follow the technical instruction of the system to open the cash drawer CR 4001 4101 4211 4002 4102 4212 4004 4104 4214 1 Under DOS prompt type MODE COM1 96 N 8 1 Hit the ENTER key 2 Type TYPE CON gt COM1 Hit the ENTER key 3 Type CTRL G Press Ctrl and G keys together Hit the ENTER key then the drawer will open 4 Hit CTRL C Press Ctrl and C keys together to return the computer back to the normal display mode In case the cash drawer is connected to serial port other than COM1 please substitute COM1 above to proper port name If the pre set security code of CR 4002 4102 4212 has been changed from default 07 Hex Please change the CTRL G above accordingly For CR4001 4101 4211 4004 4104 4214 this code can be replaced by any character CR 4003 4103 4213 1 Under DOS prompt type TYPE CON gt LPT1 Hit the ENTER key 2 Type CTRL G Press Ctrl and G keys together Hit the ENTER key then the drawer will open 3 Hit CTRL C Press Ctrl and C keys together to return the computer back to the normal display mode If the pre set security code of CR 4003 4103 4213 has been changed from default 07 Hex Please change the CTRL G above accordingly CR4005 4105 4215 CR4005 II 4105 II 4215 11 1 Please find in Posiflex Product Information CDROM or go to Posiflex web sites http www posiflex
9. utput to the Power Input jack 2 Other RS232C device can be connected to the serial O P port when needed as long as the security code makes no influence to this RS232C device 3 Set position 3 of S2 to ON and position 4 of S2 to OFF Set S1 for security code to open cash drawer In normal practice the security code is suggested to be a non displayable ASCII character for example a hexadecimal number between 01 to 1F Please refer to rear panel illustration below CR4003 4103 4213 1 Connect the drawer parallel I P port to the computer LPT port Connect the power adapter output to the Power Input jack 2 Other parallel device such as a printer can be connected to the parallel O P port when needed as long as the Security code makes no influence to this parallel device POSIFLEX 3 Set S1 for security code to open cash drawer In normal practice the security code is suggested to be a non displayable ASCII character For example a hexadecimal number between 01 to 1F Please refer to rear panel illustration below CR4001 4101 4211 4002 4102 4212 4003 4103 4213 Rear panel illustration AC 12V I P PARALLEL O P DB25F Switch is ON when pushed up SERIAL O P DB9M S1 S82 SERIAL I P DB9F PARALLEL I P DB25M GROUND S1 Set security code Default Setting BIT 1 2 3 OFF and BIT 4 5 6 7 8 ON Security code is 07H BIT 1 2 3 4 5 6 7 8 Number to be added to the 1 2 4 1 2 4 12 security code if OFF i lee i j

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SyncMaster  Funkwerk RS120  recomendações importantes guarde estas  Inter-Tel Telephone 8520 User's Manual  How does ING eSubmit work?  取扱説明書  StarTech.com 16in DB25 Parallel Female to IDC 25 Pin Header Slot Plate  TDSHーBA 保管用  Grado Alcohólico EBULLIOMETRIA - GAB Sistemática Analítica, S. L.    