1. FCC Statement Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a Suitably high level of immunity to electromagnetic disturbances FCC Warning This equipment has been tested and found to comply with the limits for a Class B Digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced technician for help You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment WEEE Waste of Electr
2. IND Ye CONNECTION PERFECTION IPower Control 2x6 User Guide English LINDY No 32656 www lindy co uk CEFE LINDY ELECTRONICS LIMITED amp LINDY ELEKTRONIK GMBH FIRST EDITION August 2011 Power 2x6 User Guide Introduction Thank you for purchasing the LINDY IPower Control 2x6 Switch This Switch allows you to control the supply of power for up to 12 devices via a TCP IP network The Switch access is password protected through a web interface connected by serial or SNMP and is powered by two separate 16A phases each powering 6 IEC C14 sockets Features Switching capacity max 2300W 10A per channel Total switching capacity up to 7360W 32A Output 12 x IEC 320 C14 Sockets Inputs 2 x IEC 320 C20 Plugs Configurable via web browser or included software Built in DHCP client Network Connectivity Ethernet 10 100 Base Tx Firmware updateable via Ethernet Supports SNMP Dimensions W x D x H 483 x 150 x 43mm Package Contents LINDY IPower Control 2x6 12 x Extension cables IEC 320 C13 IEC 320 C14 2 x UK power cords IEC 320 C19 1 x CD containing software amp manual This manual Installation amp Operation Ensure all equipment is turned off before connecting the any cables Once all cables are connected apply power to the switch then to each device individually 1 Connect the power supply cable to the power socket h at the rear of IPower 2x6 and a mains socket IPower 2x6 now is boo
3. Configuration Power Ponts IP Address IF AGL AIIE SNMP ysig Configuration HTTP HTTP Port Reguite HTTP Password yes no Administrator Login Mame admin n ser _ _Apply Password User Login Name Password Control Panel Configurtion Logout Power Forts IF Address IFACL HIIF Messages SNMP syslog Configuration Messages Gene ale Temperaluie Messages yos no Man Ter aereture o Win Temperature lo Control Pane Configuration Lagout Power Ports IP Address IPACL HTTP SNMP Syslog Config Traps Configuration SNMP a Enable ShHviF get a yas rg Community public public Enable SNWF set ves no a Community private privato Download SNMP MIE Apply Enable Traps You can activate SNMP traps If enabled IPower 2x6 will dispatch SNMP traps to all receivers listed Receivers have to be listed as follows IP address and if necessary the HTTP port e g HTTP 192 168 0 2 8000 Trap Version You can choose between SNMP traps standard 1 and 2c Use SNMP only if your network supports it Power 2x6 User Guide Configuration Syslog Sonivol Panel _ Configuration Enable Syslog You can select to have the syslog enabled US FASL HIF NME amoa or disabled Configuration Syslog Syslog Server IP If you enable the syslog you will need to Enable Syslog yes no enter the IP address of th
4. lectronique Chaque Etat membre de Union Europ enne a mis en application la nouvelle r glementation DEEE de mani res l g rement diff rentes Veuillez suivre le d cret d application correspondant l limination des d chets lectriques ou lectroniques de votre pays Italy Nel 2006 l unione europea ha introdotto regolamentazioni WEEE per la raccolta e il riciclo di apparecchi elettrici ed elettronici Non pi consentito semplicemente gettare queste apparecchiature devono essere riciclate Ogni stato membro dell EU ha tramutato le direttive WEEE in leggi statali in varie misure Fare riferimento alle leggi del proprio Stato quando si dispone di un apparecchio elettrico o elettronico Per ulteriori dettagli fare riferimento alla direttiva WEEE sul riciclaggio del proprio Stato No 32656 E FC www lindy com LINDY ELECTRONICS LIMITED amp LINDY ELEKTRONIK GMBH FIRST EDITION Aug 2011
5. firmware updates and to reset the Power 2x6 back to its factory settings see GBL _Conf exe v1 35 Search network devices Search Launch Browser Program Device Options E pPowerMeter v1 2 EPME TER Host DS Windows 2000 Version 5 0 Build 2195 Firmware update section Activate bootloader mode of the IPower 2x6 and run GBL_Conf exe see Bootloader mode section The program will automatically look for connected devices and will display their network configuration If the displayed IP address matches the factory settings 192 168 0 2 there is either no DHCP server available in the network or no free IP address could be allocated Enter a free IP address and netmask in to the relevant boxes then save these changes by clicking on Program Device Save Contig Restart the Power 2x6 by switching it off and on again and the changes will take effect Network Configuration MAC Address IP Address 00 1 9 32 00 01 14 1921680 2 Netmask Gateway 255 255 255 0 192 168 0 1 Use HTTP password HTTP Port M TCPAP Settings by DHCP 80 TT Enable IP ACL M GEL serial debug C AutoNeg Manual M TOmbit 100mbit Current Link 1 Ombit half duplex BootLoader Version 23 GBLv4 uC ColdFire Fimware Version 1 2 Host OS Windows 2000 Version 5 0 Build 2195 GBL_Conf exe 1 35 searching devices please wait 1 devices found Now click on Search in order to have the new network c
6. the device When the connector is correctly instered the recent temperature is displayed in the login window also in the switching window and can be requested via SNMP The temperature sensor can be ordered as an optional extra please contact LINDY for more information Bootloader mode To activate the bootloader mode of IPower 2x6 press the buttons select and ok on the front of the Switch for three seconds In bootloader mode it is possible to disable the password protection to update the firmware and to restore the default settings by running the program GBL_Conf exe The bootloader mode of IPower 2x6 is indicated by BOOTLDR appended to the device name in the program window of GBL_Conf exe and by the alternating red and green blinking status led When in Bootloader mode you are unable to make changes to the switching state of any port To deactivate the bootloader mode press the buttons select and ok again for three seconds Firmware update In order to update the firmware the program GBL_Conf exe and the latest firmware are needed Activate the bootloader mode of the Switch and run the program GBL_Conf exe On the left side of the program window all Switches that are in the network are listed Select the Switch you would like to update click on Program Device Firmware Update and select the location of the new firmware To activate the new firmware you need to deactivate the bootloader mode Te
7. Colour of the Power Port status LED Green Enabled Red Disabled Switching by Web interface Go to the website of Power 2x6 and Enter the IP See address into the address line of your internet browser Expert Power Control NET 2x6 hnttp IP address of IPower 2x6 and press LOGIN Here you are able to switch the ports directly You can Control Panel Configuration Logon check the status of the Power Ports by the colour of the Power Port status LED Green Enabled Red Disabled BankA Bank B Batchmode Power 1 Power2 EM Power Port A1 BEE Power Port A2 GEE Power Port A3 GEE Power Port A4 a cH GF Power Port A5 CJ 0n BEE Power Port A6 V1 0 autorefresh 10s Batchmode Each Power Port of Power 2x6 can be switched on or switched off for a selectable delay 1 30 sec or 1 30 min After the chosen delay the selected port will be switched off or switched on again automatically Optionally the device can be accessed by using the pearl script EPC _Control pl through the command line e g for automatic or time triggered switching Switching via Serial Interface The Power Ports of Switch can be managed through its serial interface which only requires a terminal program like Bits per second 115200 HyperTerminal This is a program provided under Windows Data bits 8 for free to be found under Programs Accessories Communication Connect your PC to your Switch by ag Parity no pin serial ca
8. ble RS232 and plug the device into a power Stop bits 1 outlet Now you can turn on the Switch The boot process lasts a few seconds longer than when connected by Flow control no Ethernet You can access the Switch through the terminal program as soon as the status LED shines green Choose the COM port that is connected to Switch and enter the values listed for the serial interface If you do not use HyperTerminal please make sure that the terminal program supports VT100 commands When you have connected successfully the Switch will show pert Poner Control NET 2x6 v1 0 the details to the right ress lt ENTER gt key to login Press Enter to login Power 2x6 User Guide Now the Power Ports can be switched on and off using part Power Control NET 2x6 v1 0 number keys By pressing c you can check the network configuration and by lt 1 gt OFF Poner Port Ai pressing Esc you can log out lt 2 gt OFF Poner Port A2 lt 3 gt OFF Poner Port A3 lt d gt OFF Poner Port AA lt 5 gt OFF Foner Port AS lt 6 gt OFF Fouer Port AG lt 73 gt OFF Power Port Bi lt B gt OFF Pouer Port B2 lt 9 gt OFF Power Port B3 lt A gt OFF Poner Port B4 lt B gt OFF Poner Port BS lt C gt OFF Pouer Port B6 ress lt 1 gt lt 0 gt to toggle port 1 12 ress lt z gt for configuration Henu ress lt ESC gt to logout Temperature sensor Connect the temperature sensor with the TEMP f connector on the front of
9. chnical information e Connections e 1x Ethernet RJ45 e 1x Serial Interface D SUB RS232 e 8x Power Ports IEC C13 max 10A e 2x Power supply inlet IEC C20 max 16A Network connection 10 100MBit Ethernet Protocols TCP IP HTTP SNMP Syslog Operating temperatur 0 C 50 C Dimensions 19 1 rack unit Weight 2 3 kg Power 2x6 Default settings In order to restore the default settings the Power 2x6 must be started in bootloader mode The you will need to run the GBL_Conf exe program When you run Run GBL Conf exe select the Power 2x6 device which you would like to restore the settings on and click on the Program Deviceg Reset to Fab default Please note that all current settings will be deleted The default settings will be loaded when IPower 2x6 is restarted User Guide Default settings EPC NET 2x6 Name EPC NET 2x6 IP address 192 168 0 2 Netmask 255 255 259 0 Gateway 192 168 0 0 DHCP enabled Password disabled HTTP Port 80 IP ACL disabled Power Port 1 8 Name Power Port A1 B6 After restart disabled CE FCC amp WEEE Statements CE Statement This device complies with the European Regulations for Electromagnetic Compatibility EMC of the European Union and it is equipped with the CE mark This unit has to be used with high quality shielded connection cables Only if such high quality shielded cables are used can you be sure that the EMC compatibility is not adversely influenced
10. e Syslog server CS Syslog Port 514 Syslog Port If syslog is enabled you will need to enter the port number that your Syslog server uses to receive syslog Apply information IP Access Control List The IP Access Control List IP ACL acts as an IP filter for your switch Active hosts and subnets only can contact the Switch if their IP addresses are stated in this IP ACL e g http 192 168 0 1 or http 192 168 0 1 24 If you locked yourself out by mistake please activate bootloader mode of the Switch and start Gbl_Conf exe and deactivate IP ACL SNMP To get detailed status information of IPower 2x6 SNMP can be used SNMP communicates via UDP port 161 You can also use SNMP to switch the power ports Supported SNMP commands SNMPGET request status information SNMPGETNEXT request the next status information SNMPSET request change of status You will need a Network Management System e g HP Open View Open NMS Nagios etc or the command line tools of NETSNMP to request information of Power 2x6 via SNMP SNMP Communities SNMP authenticates the requests from the named communities The public community has to be added to SNMP read requests and the private community to SNMP write requests You can see the SNMP communities like read write passwords SNMP v1 and v2 transmit the communities without encryption Therefore it is simple to spy out these communities We recommend you use a DMZ or IP ACL MIB
11. ical and Electronic Equipment Recycling of Electronic Products United Kingdom In 2006 the European Union introduced regulations WEEE for the collection and recycling of all waste electrical and electronic equipment It is no longer permitted to simply throw away electrical and electronic equipment Instead these products must enter the recycling process Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic products More details can be obtained from your national WEEE recycling agency Germany Deutschland Die Europ ische Union hat mit der WEEE Direktive umfassende Regelungen fur die Verschrottung und das Recycling von Elektro und Elektronikprodukten geschaffen Diese wurden von der Bundesregierung im Elektro und Elektronikgerategesetz ElektroG in deutsches Recht umgesetzt Dieses Gesetz verbietet vom 24 Marz 2006 an das Entsorgen von entsprechenden auch alten Elektro und Elektronikgeraten Uber die Hausm lltonne Diese Ger te m ssen den lokalen Sammelsystemen bzw rtlichen Sammelstellen zugef hrt werden Dort werden sie kostenlos entgegen genommen Die Kosten f r den weiteren Recyclingprozess Ubernimmt die Gesamtheit der Geratehersteller France En 2006 l union Europ enne a introduit la nouvelle r glementation DEEE pour le recyclage de tout quipement lectrique et
12. ith the DHCP server Using special signs may destabilize Power Ports IP Address IP ACL HTTP Messages SNMP Syslog your network In this example we named the Switch EPC NET 2x6 Control Panel Configuration Logout Configuration IP Address IP Address You can manually enter an IP Hostname EPC NET 2x6 address in this field IP Address 1921681254 Netmask 255 255 255 0 Netmask You can manually enter a Netmask in Gateway 19216813 this field Use DHCP yes Ono Gateway You can change the standard gateway address Use DHCP You can select if the switch should get its TCP IP settings directly from your DHCP server If there is no DHCP server on your network we recommend deactivating this function Configuration IP ACL contro Panel connguraton Power Ports IPAdcress IPAC HTTP SNMP Syslog Reply ICMP Ping requests You can set if the Switch should repl Ings subi Le pings Configuration IP Access Control List Enable IP Filter You can activate the IP Access Control List Reply ICMP Ping requests IP ACL of the Switch If IP ACL is active DHCP and SNMP eer res r will only work if all necessary servers and clients are registered in this list 1 2 0 i __a_a _ Bf 6 7 8 IPower 2x6 Configuration HTTP HTTP Port You can manually enter the HTTP port number if necessary Numbers range from 1 65534 standard 80 To get access to
13. onfiguration displayed Configuration by Web interface Go to the web page of IPower 2x6 Enter the IP address into the address line of your internet browser http IP address of IPower 2x6 and press LOGIN Expert Power Control NET 2x6 Expert Power Control NET 2x6 To enter the configuration menu click on Configuration Power 2x6 User Guide Configuration Power Ports Label A name with a maximum of 15 characters Control Panel Configuration Logout can be entered here for each Power Port Power Ports IP Address IP ACL HTTP Messages SNMP Syslog After power up switch The Power Ports switching state after a power on can be defined as Configuration Power Ports on off or remember last state Choose Power Port Al Power Port Al E If switching on after power up wait A switching delay of a Power Port can be defined i i Label Power Pon Al with a wait of up to 8191 seconds After power up switch off on O remember last state Combine A B Ports The Power Ports of Source If switching on after power up wait 0 seconds before switching Bank A and its equivalent of Bank B Example A2 B2 can be switch synchronized Power Ports that Combine nk Porte are configured for combined switching are marked with a C in the Switching menu and the serial interface Configuration IP Address Hostname Enter the host name of IPower 2x6 Power 2x6 uses this name to connect w
14. s All information that can be requested or changed called Managed Objects are listed in Management Information Bases MIBs There are three MIBs which can be requested from the IPower 2x6 system interface and oowerports System and interface are standardised MIBs MIB II Powerports has been created especially for IPower 2x6 Object Identifiers OID describes the location of information inside an MIB SNMP Traps SNMP Traps are system messages sent via SNMP protocol to different clients On particular events Power 2x6 will dispatch a SNMP Trap Switching of the Power Ports Syslog Syslog messages are simple text messages transmitted to a syslog server using UDP Linux OS regularly have a syslog daemon installed e g syslog ng For Windows there are some freeware tools available On following events Power 2x6 will send a syslog message Booting up Activation deactivation of syslog Switching of Power Ports Power 2x6 User Guide Switching via the push buttons The front of the Switch has two buttons select and ok Select Pushing select once make the LED of Power Port 1 start to blink which means that it is selected OK To change the switching state of the selected GI C Pushing the button again will select the next port Power Port press ok for two seconds Status select ok You can check the status of the Power Ports by the
15. the switch you have to enter the port number behind the IP address http 192 168 0 2 1720 Require HTTP Password Password protected access can be activated here In this case a user and an admin password have to be defined Passwords have maximum lengths of 15 characters Administrators are authorized to switch all ports and to modify the settings of the Switch and of all ports The username of the admin is admin Users are authorized to switch all ports but are not allowed to modify the settings of either the Switch or the ports The username of the user is user If you have forgotten your password activate the bootloader mode of the Switch start GBL Conf exe and deactivate the password request All changes need a restart of the firmware to be validated Configuration Messages Generate Temperature Messages You can select to have messages generated when the temperature is beyond the parameters set Max Temperature Manually select a Max Temperature Min Temperature Manually select a Min Temperature Configuration SNMP Config Enable SNMP get You can activate get SNMP protocol for the Switch Community Public Allows you to enter the public community Enable SNMP set You can activate set SNMP protocol for the Switch Community Private Allows you to enter the private community Download SNMP MIB You can download the MIBs of the Switch Configuration SNMP Traps User Guide
16. ting will soon be ready for use 2 Plug the Ethernet cable into the connector c on the front of Power 2x6 and connect it to your Ethernet LAN 3 Connect the client devices to the active outlets at the rear of Power 2x6 i nes CICIEICIEIEIE h i a Power Port LEDs b Power supply LEDs c Ethernet connector RJ45 d Status LED e Buttons Select and OK Power 2x6 User Guide f Temperature connector g RS232 connector h 2 x Power Socket IEC C20 max 16A i 2x6 Power Ports IEC C13 max 10A LED d Definition e Solid red LED Device is not connected to ethernet e Solid orange LED Device is connected to ethernet TCP IP settings are not allocated e Solid green LED Device is connected to ethernet TCP IP settings allocated device is ready to use e Status LED blinks alternately red and green Device is in Bootloader mode Automatic configuration by DHCP When you first switch on your IPower 2x6 it will look for a DHCP server and request an available IP address for deactivation of that feature see next section Please check the IP address allocated to the IPower 2x6 in the DHCP server settings to make sure that the same address is used at every reboot Network configuration by GBL_Conf exe For changing the network properties manually the program GBL_Conf exe is required This tool is available for free on our website www LINDY com GBL_Conf exe enables you to install
Download Pdf Manuals
Related Search
Related Contents
ダウンロード(PDF 6.08MB) Svat Handsfree 2 Wire Video Intercom System MODE D`EMPLOI MONTRE CAMERA & APPAREIL PHOTO ESPION evaluation du « dossier de soins personnalise (dsp) - SIDERAL Hydrodehn KitchenAid KUIS155HBL1 User's Manual XTC-300 取扱説明書 Manual - ActiveGPS Siemens A380 - Assistance Orange Copyright © All rights reserved.