1. abled e DELAY Enables and disables the hood s complete shutdown motor lights after 30 minutes during which the display alternatively shows the motor speed and the minutes remaining and the dot at the bottom right flashes every second To disable the DELAY press the button again or stop the motor KCVR9NE e RESET FILTRI Resets the filter saturation alarm if pressed for 2s when all the loads motor lights are off e If there is a metal Filter sat alarm FF appears on the display after 100 h of operation e If there is a CA filter alarm EF appears on the display after 200h of operation e REDUCE LIGHT INTENSITY e LIGHTS ON OFF Turns the hood lights on and off at maximum intensity The increase reduce buttons adjust the lights intensity by 4 steps excluding max intensity e INCREASE LIGHT INTENSITY Keypad lock Locks keyboard functions for example when cleaning the glass surface when all the loads are off and no alarm is on To enable disable this function press the BOOST SPEED button for about 5s until the two central segments of every digit on the display light up KCVR9NE FILTER SATURATION ALARM RESETTING THE HOOD WORKING HOURS COUNTER e After the hood has been running for 100 hours the display shows FF meaning that the GREASE FILTERS should be cleaned e After 200 hours of running the display shows EF meaning that the GREASE FILTERS should be cleaned and the A C filter cartridges replace
2. d the latter warning appears only if the A C FILTER alarm function has been enabled NOTE The warnings appear on the display only when the blower motor is off Direct procedure for enabling disabling remote control Turn off the motor and the lights and make sure that no alarms are on filter saturation Press and hold the DELAY button for about 5s until e tc flashes twice on the display meaning that the remote control has been enabled e tc flashes once on the display meaning that the remote control has been disabled SET UP procedure The default configuration is as follows e 400W motor powered by 230 VAC 50 60 Hz A C FILTER saturation alarm disabled e remote control disabled ACCESSING THE SET UP PROCEDURE 1 To access the set up procedure press button 24 for about 5s until an animation appears on the display when the animation starts you have about 5 seconds to perform the set up e Press V to enable disable the A C filter saturation alarm EF flashes twice when enabled and once when disabled Press button 24 to enable disable the remote control receiver tc flashes twice on the display when the remote has been enabled and once when the remote control has been disabled KCVR9NE
3. ess che arreda g KCVRONE specific Instruction Manual KCVR9NE Grease filter extraction instructions Top removable glass Bottom removable glass NB Extract the bottom glass in the same manner KCVR9NE 2 Grease filter extraction To remove the metal grease filter follow the instructions carried in the General Instruction Booklet KCVR9NE EN Electronic control system instructions for use Technical Features e Power supply from mains 230 VAC 50 60 Hz e Power consumption in standby 20 mA e Max load applicable to LIGHTS connection 150 W e Max load applicable to MOTOR connection 400 W capacitor motors only e Microprocessor controlled electronic control system e Loads managed by solid state components opto isolated from the mains Hardware and software EMC filtering e Connection to electronic control board by flat cable 10 poles protected by flexible sheath outside diameter 8 mm Low voltage circuits 5 V e Possibility of operating an optional load at mains voltage e Non volatile internal memory EEPROM for storing system settings and flags e Optional analog digital input for sensor and or external control Phase cutting motor control e SOFT START light switch turn the lights on gradually to guarantee better performance of electronic components e Automatic sensing of mains frequency number 50 flashing on display 230 VAC 50 Hz mains number 60 flashing on d
4. isplay 230 VAC 60 Hz mains e Software enabled reception of remote control commands all the hood s main functions can be controlled by an IR remote control protected by a propriety code operating at 24 1 bit and with an IR carrier frequency of 36 KHz e Software set up procedure for selecting and permanently storing blower motor settings and enabling A C filter saturation alarm for filter hoods e FILTER saturation alarm and alarm reset control hour TIMER for hood work KCVR9NE Operating Features Keypad with 10 touch buttons 2 digit display IR RX Buttons from left to right e MOTOR ON OFF Starts and stops the blower motor The display shows the current speed setting e SPEED Reduces motor speed V4 V3 V2 V1 e SPEED Increases motor speed V1 V2 V3 V4 e BOOST SPEED MODE Enables BOOST SPEED mode from any motor speed or when motor is off To disable BOOST SPEED press the button again and stop the motor BOOST SPEED mode is set to operate for 10 minutes during which the display alternatively shows HI and the remaining time and the dot at the bottom right flashes every second After 10 minutes the system automatically reverts to the previous speed setting e 24H AIR CHANGE Starts the blower motor at a speed that provides a flow rate of about 100 m3 h When 24h AIR CHANGE is enabled the display shows 24 24h AIR CHANGE cannot be enabled when either BOOST SPEED or DELAY OFF is en
Download Pdf Manuals
Related Search
Related Contents
DITA–Four Letters You Need to Know - Single Samsung PH63KPFLBF plasma panel Bedienungsanleitung garantie - Brunswick Marine in EMEA Center bénévole au centre social bénévole au centre social 落ち葉・庭枝焼却器 EXC-H009VME/M: User`s Manual, Rev A-3, April 1997 Chapter 1: Getting Started Mini PC con Wi-Fi 802.11ac: un sistema informático listo para usar Senco SCN200 User's Manual Copyright © All rights reserved.