1. Franke Little Butler Spare Parts For out of warranty maintenance and repairs we recommend you employ a Registered Plumber Before ordering spare parts determine the correct reference number from the exploded diagram Please quote this number Franke Triflow Unit 1 Gateway XIII Ferry Lane Rainham Essex RM13 9JY Telephone 44 0 1708 526361 Telefax 44 0 1708 550220 www franke triflow co uk Spout amp Shank FR9106 Hot Lever Kit End Cap FR9105 FR9108 Flow Straightener Hot Valve amp M FR9180 Seat Set FR9103 7 Cover FR9101 L Fixing Kit FR9107 m FR FR9104 a Qt Franke Little Butler Installation and User Guide Hot Water Dispensing System Model Series LB1000 Guarantee Your Franke Little Butler has been manufactured to the high standard you would expect of any Franke product but in the unlikely event that you should experience any defect in the materials or workmanship within one year of purchase we will replace the faulty part free of charge This is provided the unit has only been used for normal domestic purposes in the UK and that the care installation and maintenance instructions have been observed This one year guarantee is extended to five years in the case of the moving parts You should also retain your dated invoice as proof of purchase to validate any claims under our guarantee Normal wear and tear is exclud
2. ed from the guarantee Decorative surface finishes are guaranteed for one year from the date of purchase provided our advice concerning care has been observed and no scouring agents have been used 138mm rh S a ll RN 195mm Maximum work surface AL Thickness 50mm a 50mmej e 1 35mm Hole j a Tube To Heater 457mm Long a Norprene Tube lt From Heater a X Z 457mm Long S Ne wer Inlet Tube gan 305mm Long 8mm f SS 1 4 50 m l 10mm 1 4 Ji D Compression Y Fitting 280mm Heating J p J i 176mm Depth of Heating Tank 200mm Scuffs and scratches caused by improper installation or accidental damage are not covered by this guarantee Neither are slight shade variations or any damage or defect caused by incorrect installation or abuse of the fitting Service In the event of parts or service being required please contact Telephone 44 0 1708 526361 Telefax 44 0 1708 550220 www franke triflow co uk Franke Triflow Unit 1 Gateway XIII Ferry Lane Rainham Essex RM13 9JY Telephone 44 0 1708 526361 Telefax 44 0 1708 550220 www franke triflow co uk Franke Little Butler Installation Care and Maintenance Overview of the System Concept This product dispenses near boiling water on demand for your convenience This product may scald if used incorrectly and should only be opera
3. elow the sink space will be needed underneath the tank for access to the drain plug Determine the best position to enable the tubing connections to be made and mark the position for the mounting bracket approximately 50mm below the top of the tank Attach the mounting bracket to the wall and hang the tank in position IMPORTANT During installation the tank should remain unplugged with the thermostatic control in the off position The tank must be filled with water before power is connected A dry start will void the warranty see Fill the System DO NOT connect this product to the mains water supply where the supply pressure exceeds 100psi 7 bar If in any doubt please ask your registered plumber to check the water pressures Failure to comply will invalidate the product warranty IMPORTANT Avoid kinking tubes during installation as the resulting restrictions could reduce flow and cause malfunctioning of the expansion chamber Do not use pipe sealing compounds on any connections These can foul the internal mechanics and may cause objectionable taste and odour Plumbing connections must comply with all plumbing safety legislation Fill the System DO NOT PLUG IN YET Turn on the shut off valve Operate the hot lever on the dispensing head and hold down until water flows from the end of the spout This will take a little while as the tank capacity 2 3 litres and the filter housing has to be filled Operate the co
4. emperature Please register this product You can register your Franke Triflow in the following ways 1 VAUN Complete and return the FREEPOST registration card enclosed or Email cartridges franke triflow co uk Online www franke triflow co uk Telephone 44 0 1708 526361 Telefax 44 0 1708 550220
5. itial heat up and the product may purge some water Troubleshooting Should your dispenser not work correctly check the list below before calling for service The following things are not covered by the warranty Water is not hot Check if electrical supply to heating tank is plugged in Turn temperature control knob clockwise as far as possible Test the temperature again after 15 minutes Check if fuse is blown or circuit breaker is open Hot water continuously drips or sputters from spout For safety reasons this tap may drip or splutter after use This venting prevents a build up of pressure in the heating tank If this becomes excessive Turn the control knob counter clockwise to lower temperature Check the tubes connecting the faucet to the storage tank are not kinked Check the condition of the mesh filter in the 15mm to 1 4 connector and clean or replace if necessary Water does not flow Check the shut off valve is open Check if supply tube is kinked Check if the mesh filter in the 15mm to 1 4 connector is clogged Water boils or vapour appears Lower temperature setting If lowering of the thermostat setting does not stop the boiling unplug the power supply cord and contact the authorised service office CAUTION Sudden exposure of very hot water to certain glass or ceramic materials when cold can cause them to shatter or break Only use heat resistant containers and avoid dramatic changes in t
6. ld lever on the dispensing head and hold down until water flows from the end of the spout Check all connections Check for leaks IMPORTANT This dispenser is equipped with a Self Re setting Thermal Fuse Turn thermostat to lowest setting and fill tank with water before plugging the power cord from the tank into an electrical outlet If tank is empty and the thermostat set in the low setting position approximately at the 11 00 when the power cord is connected the self re setting fuse in the heater control will disconnect the current to the heater after approximately one minute thus protecting the heater from a dry start failure The fuse in the heater control will self reset after approximately 30 minutes Turn on the water supply to the tank and continue the installation Continued misuse will cause damage to the appliance and is detectable thus voiding the warranty Franke Little Butler Installation Care and Maintenance Re setting of fuse can be accelerated by turning on the water supply and dispensing water until fuse re sets in approximately 3 minutes Plug in and Turn On Plug into the electrical supply and turn temperature control clockwise to a midway position on the shaded temperature dial Water in the tank will reach maximum temperature in approximately 15 20 minutes After this time the thermostat may be safely increased up to the maximum setting Gurgling noises or perking sounds are normal during the in
7. ted by an adult For safety reasons this hot water dispensing system features a non pressurised heating tank This means that the incoming water is first routed through the valve in the dispensing head where line pressure feeding the system terminates When the valve is activated water is directed down to feed the inlet at the top of the heater tank displacing heated water up through the spout When the valve is off the tank is open to atmosphere via the spout making it impossible for the tank to be subjected to stress from an overheating condition Overview of Installation There are three main components to the system the dispensing head the filter and the heating tank The dispensing head comes with three 1 4 copper tubes and one flexible Norprene tube The two shorter 305mm copper tubes are connected to the incoming water supply via the filter The longer 457mm copper tube is connected to the inlet of the tank The flexible Norprene tube is connected to the outlet of the tank using the hose connector Preparing for the Installation As with any sink related device it is much easier to mount the dispensing head of this system onto the sink before the sink is mounted into the countertop A mounting hole of 35mm diameter standard sink ledge drilling is required It is always recommended to take the components and locate their optimum positions before starting the installation This particularly applies
8. to the heating tank as it must be positioned for the connections to the dispensing head while at the same time avoiding other mechanics under the sink Unlike most plumbing products a hot water dispenser includes an electrical system The heating tank is supplied with an earthing device An earthed non switchable outlet for this connection must be provided beneath the sink IMPORTANT DO NOT plug in the unit until all water connections have been made and the tank is filled completely Making the Supply Provision Provide a branch compression connection fora 15mm supply tube This should be done with a conventional tee and the shut off valve provided Flush the pipework before installing Mounting the Dispensing Head NOTE This product dispenses near boiling water that may scald if used incorrectly You are advised to mount this product in a suitable location out of reach from children The copper tubes are coiled for packing and must be carefully straightened before installation Position the 0 ring and feed the tubes and shank through the hole in the sink ledge or counter Assemble the clamp plate locking washer and backnut hexagon to the top for thin sinks fingertight Turn the dispensing head and the spout until the handles and spout are in the required position for use and fully tighten the backnut this will lock the spout in position Mounting the Heating Tank The heating tank must be located on a back or side wall b