1.   5VSB    1 0A 0A    Max  Combined 180W eew          Table 5   Output Loads Range 1    Note   Maximum continuous total DC output power should not exceed 700 W        3 2  DC Voltage Regulation  Ripple and Noise  The power supply output voltages must stay within the following voltage limits when  operating at steady state and dynamic loading conditions  All outputs are measured with  reference to the return remote sense  ReturnS  signal  The  5V  3 3V   12V   12V and   5VSB outputs are measure at the power supply connectors references to ReturnS  The   5V and  3 3V is measured at its remote sense signal   5VS   3 3VS  located at the  signal connector             3     Ripple  amp  Noise 120mv_   _120mV    Table 7   Regulation  ripple and noise        Ripple and Noise shall be measured using the following methods   a  Measurements made differentially to eliminate common mode noise  b  Ground lead length of oscilloscope probe shall be 0 25 inch   c  Measurements made where the cable connectors attach to the load   d  Outputs bypassed at the point of measurement with a parallel combination of  10uF tantalum capacitor in parallel with a 0 1uF ceramic capacitors   e  Oscilloscope bandwidth of 0 Hz to 20MHz   f   Measurements measured at locations where remote sense wires are connected   g  Regulation tolerance shall include temperature change  warm up drift and dynamic load    3 3  Timing Requirements  These are the timing requirements for the power assembly operation  The output  
2.  cycling of AC  and over the specified temperature range  The peak inrush current  shall be less than the rating of its critical components  including input fuse  bulk rectifiers   and surge limiting device      2 3  Input Power Factor Correction   Active PFC   The power factor at full load shall be  gt  0 99 at nominal input voltage     2 4  Input Current Harmonics   When the power supply is operated in 90 264Vac of Sec  2 1  the input harmonic current  drawn on the power line shall not exceed the limits set by EN61000 3 2 class  D   standards  The power supply shall incorporate universal power input with active power  factor correction     2 5  AC Line Dropout   An AC line dropout of 17mS or less shall not cause any tripping of control signals or  protection circuits  If the AC dropout lasts longer than 17mS the power supply should  recover and meet all turn on requirements  The power supply shall meet the regulation  requirement over all rated AC voltages  frequencies  and output loading conditions  Any  dropout of the AC line shall not cause damage to the power supply  An AC line dropout is  defined as a drop in AC line to OVAC at any phase of the AC line for any length of time        Sy DECATHLON DA700 A    3  DC Output Specification    3 1  Output Current   Loading  The following tables define two power and current rating  The power supply shall meet  both static and dynamic voltage regulation requirements for minimum load condition     Output Voltag  5V  3 3V  12V  12V
3. 5mA rms  Measurement  will be made at 240 VAC and 60Hz      Voltage Dips and Interruptions       7  Reliability    7 1  Mean Time Between Failures  MTBF     The MTBF of the power supply shall be calculated utilizing the Part Stress Analysis  method of MIL217F or Bell core RPP  The calculated MTBF of the power supply  shall be greater than 100 000 hours under the following conditions     Full rated load  120V AC input  Ground Benign  250  7 2 Warranty  Three  3  years manufacture s warranty   Technical information in this specification is subject to change without notice   The revision of specification will be marked on the cover     8  Connections  8 1  AC Input Connector    The AC input connector shall be an  EC 320 C 14 power inlet  This inlet is rated for  15 A 250 VAC     8 2  DC Wire Harness and Connector Requirements   Subject to change without notice  please see appendix  wireharness drawing     P1  Motherboard Power Connector  Connector housing  24  Pin Molex 5557  No 39 01 2240  or Equivalent  Contact  Molex 5556T  No 44476 1111  or Equivalent    af ewe   ome   owe  com ck   eme  O ewo   ne   eme  com   se   em  O swo   ne   eme  O om   s   em  s  om   m   eme  o  om   m   eme  O om   se   e  o  om   a   oe  To  A si06    oe  swe  Red BANG  YC       a DECATHLON DA700 A    P2  Processor Power Connector  sectional connector 4 Pin   4 Pin   Connector housing  8  Pin Molex 5557  39 01 2080  or Equivalent  Contact  Molex 5556T  39 00 0059  or Equivalent    ie ANG       4 
4. Pin HDD   CD ROM Drive Power Connectors  Connector housing  4  Pin AMP  1 480424 0 or Molex 8981 04P or Equivalent  Contact  Amp 61314 1 or Equivalent       Pin Signal Color Size    18 AWG  18 AWG       Small 4 Pin   Floppy Disk Drive Power Connectors  Connector housing  4  Pin AMP  171822 4 or Equivalent       Pin Signal Color Size    22 AWG  22 AWG    22 AWG  22 AWG       Serial ATA Power Connector   This is a required connector for systems with serial ATA devices   Molex Housing  675820000 or Equivalent   Molex Terminal  67510000 or Equivalent    Yellow Green stripe 18 AWG  18ANG  COM    com   o   em    Workstation Power Connector for High Power Graphics Cards   For workstation systems with high powered graphics cards an additional power  connector to the baseboard may be needed  This connector supplies additional  12V  power for the higher power level graphics cards used in workstation applications   Connector housing  6 pin Molex 45559 0002 or equivalent   Contacts  Molex 39 00 0207 or equivalent       PCI Express 6 Pin    jaan  8AN  8AN  8AN  18an  iane    PCI Express 8 Pin    iB AWG  T8 AWG  I8 AWG    om   s   om    oom eck   a       7  CoM   Blek    18AWG  com   Bak    18G       COM  COM  iB AWG  COM  COM    SS DECATHLON DA700 A    9  Physical Characteristics Size    9 1 Power Supply Dimension  150 mm W  x 86 mm H  x 180 mm D   Mechanical drawing  Please refer to the attached sketch     To be valid  this sheet must be filled out by  your salesperson at the time of pur
5. SILVERSTONE    Designing Inspiration       DECATHLON    DA 00    The all around power  Class leading single  12V rail with 58A   50  C    100  modular cables   Single PCI E 8pin connector  amp  quad PCI E 6pin connectors  Quiet running 120mm fan   Support for ATX 12V 2 2  amp  EPS 12V   Active PFC   Efficiency greater than 80     ae  SPECIFICATION    SilverStone DECATHLON DA700  Switching Power Supply  With Active PFC  PS 2 Modular 700W    1  General  This is the specification of Model DA700  it is intended to describe the functions and  performance of the subject power supply  This PS 2 700 watts switching power supply  with Active PFC  Power Factor Correction  capability  meets EN61000 3 2 and equips  Full Range Input features     2  AC Input Specifications    2 1  AC Input Voltage  Frequency and Current   Rating  100V 240Vac  47   63Hz  10 5A     The power supply must operate within all specified limits over the input voltage range in   Table 1    Harmonics distortion of up to 10  THD must not cause the power supply to go out of   specified limits        Parameter Minimum Norminal Maximum Max  Current    Voltage  115V  90 Vac 100 120Vac 132 Vac  Voltage  230V  180 Vac 200 240Vac 264 Vac             Frequency 50   60 Hz       Table 1   AC Input Voltage and Frequency    2 2  AC Inrush Current   The power supply must meets inrush requirements of any rated AC voltage  during turn  on at any phase of voltage  during a single cycle AC dropout condition  during repetitive  On Off
6. Table 14  Over Current protection    4 2  Over Voltage Protection  The power supply shall shut down in a latch off mode when the output voltage  exceeds the over voltagelimit shown in Table 4     Table 15  Over Voltage protection     4 3  Short Circuit Protection  The power supply shall shut down in a latch off mode when the output voltage is  short circuit           5  Environmental Requirements  5 1  Temperature    Operating Temperature Range  OC 50 CG  32 F  122 F     Non Operating Temperature Range  40  C   70  C   40  F   158  F            Sy DECATHLON DA700 A    5 2  Humidity    Operating Humidity Range  20    90 RH non condensing       Non Operating Humidity Range  5    95 RH non condensing    6  Agency Requirements  6 1  Safety Certification                  UL 60950 1 2000Edition  IEC60950 1  3 4 Edition EU             Bene Seen Low Voltage Directive  73 23 EEC   CB  TUV  CCC  ae FCC Part15   Radiated  amp  Conducted Emissions   CISPR  RFI Emission  22 3  Edition   EN55022  1998   A1  2000   PFC Harmonic  EN61000 3 2 2000  Flicker  EN61000 3 3  1995   A1  2002       Immunity against  EN55024  1998   A1  2001 and A2  2003                    Electrostatic discharge   IEC 61000 4 2   Radiated field strength   IEC 61000 4 3   Fast transients   IEC 61000 4 4   Surge voltage   IEC 61000 4 5   RF Conducted  IEC 61000 4 6           IEC 61000 4 11  Table 16  Safety Certification    6 2  AC Input Leakage Current    Input leakage current from line to ground will be less than 3 
7. chase   Store    Purchaser      aa  Purchase date   L  l 7 NG J    Model No      S  Serial No             SilverStone Technology Co   Ltd     www silverstonetek com    support  silverstonetek com  Issue date  July  2007  NO G11204460    
8. ignal Characteristic    Signal Type                3 5  Efficiency  The efficiency is specified at 50  and 20  loading conditions to help reduce system  power consumption at typical system loading conditions     100  of maximum 50  of maximum 20  of maximum    3 6   5VSB  Standby   The  5VSB output is always on   5V Standby  when AC power is applied and power  switch is turned on   The  5VSB line is capable of delivering at a maximum of 3A for PC board circuit to  operate     E    4  Protection  Protection circuits inside the power supply shall cause only the power supply s main  outputs to shutdown  If the power supply latches off due to a protection circuit tripping   either a AC cycle OFF for 15 sec  or PSON  cycle HIGH for 1 sec must be able to restart  the power supply     4 1  Over Current Protection  This power supply shall have current limit to prevent the  5V   3 3V  and  12V  outputs from exceeding the values shown in table 14  The current limit shall not trip  under maximum continuous load or peak loading as described in Table 5  The power  supply shall latch off if the current exceeds the limit  The latch shall be cleared by  toggling the PSON  signal or by cycling the AC power  The power supply shall not  be damaged from repeated power cycling in this condition  The  12V and  5VSB  outputs shall be shorted circuit protected so that no damage can occur to the power    supply   Voltage Shutdown Mode  110  160  Latch Off  110  160  Latch Off  110  160  Latch Off    
9. ts to PWOK  asserted at turn on    Tpwok off Delay from PWOK deasserted to output voltages   5V   3 3V    12V  dropping out of regulation limits    Tpwok low Duration of PWOK being in the deasserted state during an off on  cycle using AC or the PSON  signal       Delay from  5VSB being in regulation to O Ps being in regulation  at AC turn on     mS  mS  mS  mS  mS  mS  mS  mS    Tsb vout    Tpson pwok   Delay from PSON  deactive to PWOK being deasserted  a       1000    Table 11   Turn On Off Timing       Sy DECATHLON DA700 A    AC Input AC Off AC On       Tvout_holdup      Tac_on delay   lt  gt  f    Tsb_on delay            PWOK      Tpwok_off     Tsb_on delay      Tpwok_off    Tpwok_holdup            lt  Tpson_pwok             lt             Tsb_vout 1  Tsb_holdup    Min  gt 70mS    i Toson_on_delay  PSON          e    AC turn on off cycle      i    PSON turn on off cycles     Figure 2   Turn On Off Timing    3 4  Remote On Off Control   PSON   The PSON  signal is required to remotely turn on off the power supply  PSON  is an  active low signal that turns on the  5V   3 3V   12V and  12V power rails  When  this signal is not pulled low by the system  or left open  the outputs  except the   5VSB and V bias  turn off  This signal is pulled to a standby voltage by a pull up  resistor internal to the power supply     Accepts an open collector drain input from the system   Pull up to VSB locted in power supply     PSON    Low Power ON  PSON    High Power OFF    Table 13   PWOK S
10. voltages must rise from 10  to within regulation limits  Tvout_rise  within 5 to 70mS  The   5V   3 3V and  12V output voltages should start to rise at about the same time  All  outputs must rise monotonically  The  5V output needs to be greater than the  3 3V  output during any point of the voltage rise  The  5V output must never be greater than  the  3 3V output by more than 2 25V  Each output voltage shall reach regulation within  50 mS  Tvout_on  of each other during turn on of the power supply  Each output voltage  shall fall out of regulation within 400 mS  Tvout_off  of each other during turn off  Figure 1  and figure 2 show the turn On and turn Off timing requirement  In Figure 2  the timing is  shown with both AC and PSON  controlling the On Off of the power supply     Tvout off All main output must leave regulation within this time  Table 10   Output Voltage       Vout    vi s  V4 i          i        gt   Tvout_on oy Tvout_off      I I  Tvout_rise              Figure 1  Output Voltage Timing    Tsb on delay   Delay from AC being applied to  5VSB being within regulation     Tac on delay ae Hell AC being applied to all output voltages being within E    Tvout holdup   All main output voltage stay within regulation after loss of AC  Tpwok holdup   Delay from loss of AC deassertion of PWOK     Tpson on delay ae from PSON  active to output voltage within regulation  imits     Units    MAX  1500   mS    2500   mS    Tpwok on Delay from output voltage within regulation limi
    