CyberPower CSW8RU power distribution unit PDU

image

Contents

1. Cancel to refresh the selection NOTE When turning on off at a duration time is applied the Outlet control page will turn to Pending Log page automatically Current Status displays the power status of each outlet Configuration allows configuration of the duration time to turn on off the outlets and enable or disable of manual switch on off Select the outlet number to enter its sub menu Give name to the device Optional settings Enter the duration time Please note that time is entered using 24Hr clock format hh mm ss Enable or disable the manual switching on off When manual disabled the outlet can not be switched on or off from the front panel 5 Click Apply for operation Select Cancel to refresh the settings eh CyberSwitch Network Management System Logs displays an event log for the CyberSwitch The section contains Pending Log Schedule and Event Configuration Cyber Switch 192 168 0 201 Event Log Date M D Y Time H M S Event Description 01 16 2000 00 31 33 Outlet 1 turned off 01 17 2000 00 48 17 Outlet 1 turned on 01 17 2000 00 48 19 Outlet 2 turned on 01 17 2000 00 48 20 Outlet 3 turned on 01 17 2000 00 48 25 Outlet 1 2 turned off 01 17 2000 00 48 26 Outlet 3 turned off Delete the event log S Severe W Warning 1 Information Pending Log displays the current pending commands Schedule The user may set the outlets on the CyberSwitch t
2. disconnect LINK Yellow The CyberSwitch is disconnected from the Network Tx Rx Green Flashing Network Data transmitting CyberSwitch Network Management System INSTALLATION GUIDE Step 1 Hardware Installation 1 Connect the Ethernet cable to the LAN port of the CyberSwitch 2 After the above procedures are completed please turn on the CyberSwitch To reset the IP Address to default value press the Reset Button on the CyberSwitch front panel continuously for 6 seconds that the Status Indicator will blink for 3 times continuously and then you will hear a short beep in the end 3 Power off the CyberSwitch and then power back on Step 2 Setup the IP address for the CyberPower CyberSwitch THREE OPTIONS Option 1 Setup the IP address via DOS 1 If you have a DHCP server the DHCP server will give you the MAC address to IP mappings Just open your Web Browser with the IP provided by DHCP server 2 If you don t have DHCP server obtain the MAC address for the CyberSiwtch Each CyberSwitch has a unique MAC address which can be found using option 3 on page 5 of this manual 3 For example to assign an IP address 192 168 20 240 which is in the same subnet as your computer with CyberSwitch which has the MAC address for example 00 0c 15 00 01 23 Open a DOS prompt and run an ARP command Example arp s 192 168 20 240 00 0c 15 00 01 23 and press Enter to set the IP address 4 To verify the setting run a ping com
3. for the IP address press the Reset Button for 4 seconds that the Status Indicator will blink for 2 times continuously To reset all settings to default value press the Reset Button for 6 seconds that the Status Indicator will blink for 3 times continuously and then you will hear a short beep in the end 8 LAN Port 10Base T Ethernet connector 9 Link Indicator indicates the status of connecting to the network This LED is illuminated when CyberSwitch is connected to the network 10 Tx Rx Indicator This LED is illuminated when data transmitting 11 Communications Port provides a Serial connection and communication path between the CyberSwitch and the Local computer A OND O CyberSwitch Network Management System REAR PANEL DESCRIPTIONS CSW8RU P PO Pe2 PCI CSW8RE ladaa W ca 12 RJ 11 13 communication Port Provides communication of the Switch Shutdown Service 14 AC output outlets CSW8RU NEMA 5 15P CSW8RE IEC320 1 C13 15 Circuit Breaker Reset for Overload protection 16 AC input Definitions for LED Indicators Mode Description The CyberSwitch is off The CyberSwitch is on Normal condition Solid On The Network setting is invalid Flashing Temperature Humidity exceed user settings Blinking The Reset button is pressed PWR Green Status Red The Manual Button is pressed The Manual Button is not pressed The outlet is switched on The outlet is switched off Ethernet
4. 00 2 Internal Time hh mm ss 0023204 3 System Name Cyber Switch 4 System Contact Administrator 5 System Location Server Room 0 Return to previous menu Enter Your Choice gt 3 Account Group Configuration Utility Menu 1 Web Administrator User Name cyber 2 Web Administrator User Password cyber 3 Web Device User Name device 4 Web Device User Password cyber 5 COM Port Configuration Password cyber 0 Return to previous menu Enter Your Choice gt 4 Default Group Configuration Utility Menu 1 Reset System to Default 2 Reset System to Default Except IP 0 Return to previous menu Enter Your Choice gt e CONFIGURATION SYSTEM LOGOUT figuration Utility System up system again Type setup to relogin gt gt CyberSwitch Network Management System CONFIGURATION GUIDE Outlets menu contains Control Current Status and Configuration Cyber Switch 192 168 0 201 Outlet Control Action Type Duration Time lmmediately Turn On Outlet 1 Turn On Outlet 2 Turn On Outlet 3 Turn On Outlet 4 Turn On Outlet 5 Turn On Outlet 6 Turn On Outlet 7 Turn On Outlet 8 E j E y y i N Control allows switching on off the outlets immediately or after a specific duration Click the Outlet number and the Action Type and then click Apply for operation A selected button will turn a green color Only by clicking Apply will the selected command become active Select
5. CyberSwitch Network Management System Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet After installing the hardware and setting up an IP address this state of art technology allows network administrators an easy way to control AC power for various connected devices such as servers hubs routers modems telephone systems and other equipment No software installation is needed Simply use a web browser such as Internet Explorer or Netscape to access the CyberSwitch Servers workstations connected to CyberSwitch could be installed with Switch Shutdown Service to enjoy extra value packaged features Features Remote management and configuration of outlet via Web Browser or NMS Supports TCP IP UDP DHCP SNMP HTTP protocol Built in 10Mbps fast Ethernet interface for direct LAN connection Automatic events notification via SNMP Trap Flexible Event Action setting Schedule shutdown startup of various connected devices remotely Event logging to trace CyberSwitch operation history SNMP MIB provided Quick installation and user friendly interface Security management provided EMI RFI filtering built in surge and spike suppression Auto shutdown service to protect servers workstations from data loss due to power failure System Requirements e Acomputer with a Web Browser e An Ethernet connection to an existing network e SNMP functions NMS Netwo
6. arning Severe Event Log SNMP Trap Contact Shutdown Signal min s before outlet off rai Event Generaton There are three severity levels Information Warning and Severe Please refer to their definitions below The user can assign which severity levels will be recorded in the event log and which severity levels will cause SNMP traps to be sent Information an event that requires no action Warning an event that does not require immediate attention but the condition should be monitored Severe an event that requires immediate attention ol Determine the severity levels and click the option buttons 2 Enter the time the signal is to be sent The default value is 3 minutes The time must be less than 99 minutes and greater than 1 minute 3 Click Apply to activate the settings Environment To set the temperature and humidity range with beeper warning or none by each outlet 12 CyberSwitch Network Management System Summary Displays the current CyberSwitch Status Cyber Switch 192 168 20 200 Summary Outlet Status Outlets On All Outlets Off None Temperature 27 C Humidity 49 Environment normal no alarms present System Status Date 01 01 2004 Thursday Time 00 07 22 Name Power Manager User Administrator Contact Administrator Location Server Room UpTime 0 Day 0 Hour 7 Minutes Status OK MAC 00 Oc 15 00 01 24 Version 1 01 13 CyberSwitch Network Ma
7. lect an IP Address for CyberPower CyberSwitch Make sure the IP Addresses for the computer and the CyberSwitch belong to the same subnet Refer to the above network information a possible IP Address for CyberSwitch could be 192 168 20 hereafter represents any number between 1 and 255 Similarly if the Subnet Mask is 255 255 0 0 the IP Address for CyberSwitch could be set up as 192 168 To ensure there is no other equipment connected to the network using the same IP Address you choose you run a ping command Ping 192 168 20 240 in MS DOS mode when the IP Address you would like to set is 192 168 20 240 If the response is presented as below the IP address is not used and available for CyberPower CyberSwitch Pinging 192 168 20 240 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out If the response is shown as below the IP address is already in use by another device Try another IP address until an available address is found Pinging 192 168 20 240 with 32 bytes of data Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 14 CyberSwitch Network Management System Technical Specifications Model Input Nominal Input Voltage Acceptable Input Voltage Normal Input Frequency Input Connection Type Maximu
8. lows one administrator and one device user to access the system The administrator can access all of the management menus The device user can access only Outlet Logs and Summary menus 1 Select Administrator Device User and enter the User Name and Password The username and the password must be less than 15 characters The default username is cyber and the password is cyber 2 Click Apply 3 Type the password to confirm the password was keyed properly Identification Assign the CyberSwitch system s name contact and location 10 CyberSwitch Network Management System Network menu contains TCP IP Access Control and Trap Notification Cyber Switch 192 168 20 152 TCP IP Configuration TCP IP Settings BOOTP DHCP Status Enable Disable System IP f192 168 20 152 Cd Subnet Mask 255 255 2550 Default Gateway 192 168 201 si id Web Http Port Booo E Apply Cancel TCP IP displays IP Address Subnet Mask Default Gateway and Web Http Port as well as enable or disable the BOOTP DHCP configuration Click Apply to activate the settings click Cancel to revert to previous inputs Access Control serves to control access to the NMS Limit system data access through SNMP 1 Input the manager IP address This address will limit the access to the NMS The default value 0 0 0 0 or 255 255 255 255 allows access for all NMS 2 Input the community functioned as password
9. ly on the CyberSwitch or type setup 6 Type the default password cyber to enter the Power Manager Configuration Main Menu Power Manager Configuration Main Menu 0 UDH Exit Network Settings System Configuration Account Settings Configure System to Default Enter Your Choice gt 7 Type the number of each menu for further settings Type 1 for Network Settings Type 2 for System Configuration Type 3 for Account Settings Type 4 for Configure System to Default Type e to exit Please note The configuration page will timeout and logout after three minutes of inactivity Enter Your Choice gt 1 Network Group Configuration Utility Menu Ethernet Address 00 0c 15 00 02 00 1 System IP 192 168 20 177 2 Subnet Mask i 29525952590 3 Default Gateway 192 168 20 1 4 Web Http Port 80 5 BOOTP DHCP Enable 0 Return to previous menu CyberSwitch Network Management System You already exited Please relogin to set Con Enter Your Choice gt 2 System Group Configuration Utility Menu 1 Internal Date mm dd yyyy 01 01 20
10. m Input Current Cord Length Output Nominal Output Voltage Maximum Current Per Phase Output Connections Overload Protection Environmental Operating Temperature Storage Temperature Relative Humidity Physical Dimension HXW xD Net weight Safety Approval CSW8RU CSW8RE oe E ree 0 to 45 C 32 to 113 F 0 to 45 C 32 to 113 F 0 95 Non Condensing 45 x 439 x120mm 45 x 439 x120mm 1 77 x 17 28 x 4 72 inch 1 77 x 17 28 x 4 72 inch 2 12kg 4 67 lbs 2 12kg 4 67 lbs UL FCC m Specifications subject to change and without notice 15
11. mand ping 192 168 20 240 If you receive a reply the IP address has been set To find an IP address for the CyberSwitch please refer to Appendix 2 If you want to assign an IP address which is in a different subnet to your computer you should follow Step 2 Then you can enter the Browser Mode Configuration and enter the correct IP address and subnet for its final location 1 Open your Web Browser Internet Explorer or Netscape 2 Enter the IP Address which you assigned in Step 2 Option 1 above 3 On the login page enter the current password The default username is cyber and the default password is cyber 4 Select Network and click on TCP IP configuration to change the IP address Click Apply to save the changes CyberSwitch Network Management System Option 2 Setup the IP address through Network Route When you first time use the CyberSwitch your workstation is normally not able to communicate to CyberSwitch because they are not in the same IP subnet You may use route add command to manipulate the network routing table in your workstation to implement the configuration 1 Please procure a workstation and set up the TCP IP protocol if necessary 2 To add a routing condition please enter the below command Route add 192 168 20 177 61 222 33 225 Assumption the IP address of the workstation is 61 222 33 225 Option 3 Setup the IP address through Communications Port 1 Connect the CyberSwitch a
12. maximum of 15 characters 3 Select one of the permission options Read Write or Disable 4 Click Apply to activate the settings click Cancel to revert to previous inputs Definitions for Permission levels The NMS can read data at any time but can never write data The NMS can read and write data at any time provided there is not another user logged in Disabled The NMS cannot use Read or Write Trap Notification Identify NMS that will receive traps 1 Click on Trap Receiver to enter the Trap Configuration page 2 Input the receivers name and IP address This address will identify the receiver of traps The default value 0 0 0 0 or 255 255 255 255 defines all NMS as receivers 3 Input the community functioned as password maximum of 15 characters 4 Click Apply to activate the settings click Cancel to revert to the previous settings 5 The applied Trap Receiver will be listed on the Trap Notification page You could click a Trap Receiver to change the name the IP the community and the status including Enable Disable and Delete Enable The trap will be generated Disable The trap will not be generated Delete The trap receiver will not remain on the list 11 CyberSwitch Network Management System Configure menu contains Event Generation page and Environment page Cyber Switch 192 168 0 201 Event Generation Receiver Information W
13. nagement System Appendix 1 IP Address Settings of CyberPower CyberSwitch Overview All devices on a computer network need to have an IP address Each device s IP address is unique The same address cannot be used twice In order to assign an IP address to the CyberPower CyberSwitch first you must determine the range of the IP address and then you choose a number that is in this range It is essential to use an IP address that is not currently in use PLEASE NOTE You may need to contact your network administrator He She will assign the IP addresses for your Management Card Procedures to find an IP address 1 Locate the subnet of CyberPower CyberSwitch One way to determine the range of possible IP addresses is to access the network configuration of a computer connected to the network For example using a MS Windows operating system click on Start and select Run Type command into the open box and click OK At the DOS Mode Prompt type ipconfig all and press Enter The computer will display network information as below Ethernet adapter Connection specific DNS Suffix Xxxx com Description D Link DE220 ISA PnP LAN adapter Physical Address 1 O0 80 C8 DA 7A CO DHCP Enabled Yes Default Gateway 608 106 20 DHCP SGIvel vacshswnavnvscannsper 192 168 20 1 DNS Servers 2 211 20 71 202 168 95 1 1 Se
14. nd the local computer via the included RS232 cable 2 From the workstation running MS windows click on the Hyper Terminal of the communications from the accessory programs as below showed fe Programs Remote Assistance W Paint fm Games gt Program Compatibility Wizard A Documents at Microsoft Visual Studio 6 0 gt Synchronize g _ 2 Microsoft Web Publishing gt Tour Windows xP gt Settings lt z Ln Norton Internet Security gt Windows Explorer 8 Search gt n Startup gt fap Communications F 2 HyperTerminal 2 windows Media Player S windows Movie Maker e Network Connections k ED Help and Support fi Accessories A WordPad Network Setup Wizard x JJ Run 3 Windows Messenger cI New Connection Wizard n 0 PowerPanel Plus gt S Remote Desktop Connection FS i P Log Off victor i i g Turn Off Computer 3 Enter a name and choose an icon for the connection Connection Description New Connection Enter a name and choose an icon for the connection Name Power anager x gt CyberSwitch Network Management System 4 Setup the COM port parameters by filling in the values 4800 bps 8data bits no parity 1 stop bit and no flow control 5 Slightly press the COM1 Properties prm Port Settings Bits per second Data bits 8 Parity None Stop bits 1 Flow control M v reset button momentari
15. o automatically shutdown and restart at consistent times daily weekly or once Daily a specific time of the day Weekly a specific day and time of the week Once a specific date and time 1 Click on Outlet Schedule to enter the sub menu Schedule Time Table for adding a new schedule 2 Select Daily Weekly or Once by clicking its button and then enter the time A selected button will turn a green color Please note that time is entered using 24Hr clock format hh mm 3 Click Apply to enter Outlet Selection 4 Select the outlet number to be applied to the schedule A selected button will turn a green color 5 Click Apply to active the settings Click Cancel to refresh the settings The applied scheduled settings are listed in Schedule menu Please Note The management system allows only 10 scheduled settings Event Log displays the CyberSwitch events by date and time More than 200 events can be displayed CyberSwitch Network Management System System menu contains System Time User Accounts and Identification Cyber Switch 192 168 0 201 System Identification Identification Settings Name Cyber Switch Contact Administrator Location Server Room System Time serves to setup the CyberSwitch system s Date and Time Click Apply to active the settings Click Cancel to refresh the settings User Accounts serves to setup user accounts The system al
16. rk Management Station compliant with SNMP Application Remote g iE TCP IP Network Ethernet Master Unit Control all receptacles individually Computer Router Communications Power Cord Senyor A Smart shutdown through RJ11 interface Contents of Package Inspect the CyberSwitch upon receipt The package should contain the following items 1 Each CyberSwitch unit 1 Each 10 ft Power cord 2 Each Rack mounting bracket 1 Each RS232 cable Pin to Pin 4 Each 6ft RJ11 to RS232 combo cable 1 Each Warranty Registration Card 1 Each CD disk for software and User s Manual CyberSwitch Network Management System Basic Operation FRONT PANEL DESCRIPTIONS 5 6 10 11 4 i Manual l E l Press Both j CAA TEA R DE EEA E L R 000000000 es a es E a On Off Switch To turn on off the CyberSwitch PWR Indicator indicates the status of on off of the CyberSwitch Status Indicator indicates the status of CyberSwitch Manual Button amp Outlet Buttons To switch on off the outlets Press and hold the Manual Button the Outlet button to toggle on off Manual Indicator indicates when the Manual Button is pressed Outlet Indicator indicates the on off status of each outlet 7 Reset Button is used to reset the settings To enable COM Port settings slightly press the Reset Button that the Status Indicator will blink once To reset all settings to default value except