Home
Allied Telesis AT-A65 switch component
Contents
1. first release it by gently pulling the release lever then pull it out of the socket Never force a transceiver into or out of a socket 613 001135 RevA 6 AT A65 Expansion Module release lever module_sfp eps 8 Restart the switch Until the switch is restarted the output of the show system and show switch port commands cannot reflect the newly inserted module or SFP When you restart the switch the Fault LED may flash for approximately 10 seconds as it runs internal tests 9 Check that the PWR LED on the switch s front panel lights green If the LED fails to light refer to Troubleshooting on page 6 10 Connect the twisted pair or fiber optic data cable If fitted remove the expansion module s port dust cover and connect the data cable Make sure the cable connection is secure l l Check the expansion module s LEDs Use the table in AT A65 Expansion Module LEDs on page 7 to check the module s LEDs Information on switch system and switch port LEDs can be found in the Troubleshooting section of the Hardware Reference for your switch Troubleshooting This section provides information on how to detect and resolve the most common problems that can cause expansion modules to malfunction Other sources of troubleshooting information are m www alliedtelesis com m The Software Reference for your switch unit Performing the following tasks will eliminate the most common faults m Check that th
2. AT A65 Expansion Module Installation and Safety Guide MVE Allied Telesis 2 AT A65 Expansion Module AT A65 Expansion Module Installation and Safety Guide Document Number 613 001135 Rev A Copyright 2008 Allied Telesis Inc All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesis Inc Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis has been advised of Known or should have known the possibility of such damages All company names logos and product designs that are trademarks or registered trademarks are the property of their respective owners 613 001135 RevA Installation and Safety Guide 3 Package Contents The following items are included with each AT A65 expansion module Contact your authorised Allied Telesis distributor or reseller if any items are damaged or missing m One AT A65 expansion module m One AT A65 Expansion Module Installation and Safety Guide m One warranty card Compatible Switches A Caution Attemptin
3. T you can use Category 3 cables or better For 100 1000Base T you can use Category 5 cables or better The maximum cable length is 100 m 328 ft Installing an AT A65 Expansion Module You can insert or remove a module while the switch is powered on The Fault LED will flash 7 times You must restart the switch to turn off the flashing LED and make a module ready for operation I Read the safety information For safety information see the AT 8600 Series Installation and Safety Guide A copy of this guide is supplied with each switch and can also be downloaded from www alliedtelesis com support 2 Gather the tools and equipment you will need You will need a screwdriver You should also have any cables required for connecting the expansion module to other network devices 3 Remove the appropriate face plate or current expansion module on the switch s front panel Use a screwdriver to loosen the captive screws on the face plate or expansion module When removing an expansion module make sure that when you slide the module out that it remains aligned with the card guides as shown in the figure on the following page If no expansion modules are currently installed then install the AT A65 into the switch s left bay This simplifies VLAN configuration If you have removed a face plate keep it for future use If you later remove the expansion module replace the face plate to prevent dust and debris from entering the switch and t
4. e AT A65 is correctly installed 613 001135 RevA Installation and Safety Guide 7 m Make sure the power cord is securely connected to the switch and power outlet m Check that the power supply voltage to the switch is stable m Check that the correct data cables are being used and that their connections are secure m Make sure that other network devices are working properly m Use the show install command to check that the latest software version is loaded See the AT 8600 Series Software Reference for more information about obtaining the latest software version m If the switch is malfunctioning reboot it by pressing the recessed Reset button or entering the command restart reboot Alternatively power OFF and ON the switch unit by disconnecting and reconnecting the main power supply including if connected the RPS power AT A65 Expansion Module LEDs Both the copper and the SFP ports share the same LEDs LED State Function 10 Green The port is operating at OMbps Off The port is not operating at OMbps 100 Green The port is operating at 00Mbps Off The port is not operating at OOMbps Both 10 and 100 Green The port is operating at 000Mbps FDX Green The port is operating in full duplex mode Off The port is operating in half duplex mode ACT Flashing green There is data activity on the port Off There is no data activity on the port Environmental Conditions Operating Temperature 0 t
5. g to install a module into a switch which is not compatible may damage the switch and the module Compatible expansion modules are listed in your switch s Hardware Reference If you are unsure of a module s compatibility contact an authorised Allied Telesis distributor or reseller The AT A65 is compatible with the following Allied Telesis switches m AT 8624T 2M m AT 8624PoE To be compatible with the AT A65 the switch must run software version 2 9 1 17 or higher of the AlliedWare operating system Compatible Data Cables and SFPs The AT A65 expansion module can act as either a m 1000Base X SFP expansion bay or m 10 100 1000Base T copper port with RJ 45 connection The module can automatically switch between the copper and fiber interface When an SFP is installed in the AT A65 the SFP port is considered the active port and the copper port becomes disabled When there is no SFP installed then the copper port becomes the active port SFP expansion bay qualities The following SFP types are supported m 1000Base SX fiber m 1000Base LX fiber m 1000Base ZX fiber 10 100 1000Base T copper and 00Base FX SFPs are not supported 613 001135 RevA 4 AT A65 Expansion Module 10 100 1000Base T copper port qualities The port has the following qualities m 10 100 and 1000Mbps auto sensing m half duplex and full duplex auto negotiation at 10 100Mbps m full duplex auto negotiation at O00Mbps m auto MDI MDI X For 0Base
6. o 40 C 32 to 104 F Storage Temperature 25 to 70 C 13 to 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing 613 001135 RevA 8 AT A65 Expansion Module Regulatory Standards U S Federal Communications Commission RADIATED ENERGY Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canadian Department of Communications This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Emissions EN55022 VCCI 47 CFR Pt 15 FCC AS NZS CISPR22 Immunity EN55024 VCCI Safety IEC60590 1 EN60950 1 UL60950 1 CSA C22 2 No 60950 1 03 EN60825 Where To Find More Information For further details about you
7. o maintain proper airflow 613 001135 RevA Installation and Safety Guide 5 4 6 Prepare the expansion module In an antistatic environment remove the module from its packing material Be sure to observe ESD precautions Warning Do not attempt to install an expansion module without observing correct antistatic procedures Failure to do so may damage the switch or expansion module If you are unsure what the correct procedures are contact your authorised Allied Telesis distributor or reseller Slide the expansion module into place Make sure the module is aligned with the card guides on each side of the bay Slide the expansion module into the slot until the module face plate makes contact with the switch card guide switch_module eps Secure the expansion module to the switch Firmly press the expansion module until its connectors engage the expansion bay connectors inside the switch Use a screwdriver to tighten the expansion module s screws Do not over tighten the screws Install the SFP if desired Warning Do not look into the optical ports of SFP cables or transceivers Invisible laser radiation may be emitted from disconnected fibres or connectors You must insert the SFP transceiver with the release lever hinge at the bottom See the following figure as a guide To insert an SFP transceiver slide the transceiver into the SFP socket and firmly press it until it engages To remove an SFP transceiver
8. r switch see m The AT 8600 Series Installation and Safety Guide which provides safety and statutory information and outlines the procedure for installing switch units m This AT 8600 Series Switch Hardware Reference m The AT 8600 Series Software Reference which provides detailed information on configuring the switch and its software For other expansion options for your switch see m The AFA45 xx Series AT A46 and AT A47 Expansion Modules Installation Guide which outlines the procedure for installing expansion modules and provides technical specifications for the modules You can download these documents and updates from www alliedtelesis com You need Adobe Acrobat Reader software to view search or print these documents You can download it from www adobe com OD N O U 613 001135 A
Download Pdf Manuals
Related Search
Related Contents
Phoenix Contact CLIPLINE Control Cabinet Technology Phonix PIOIP4GR mobile phone case 施工説明書 SOURCE. STORE. DISTRIBUTE. User Manual BePunctual Staff Punch Station 平成26年5月15日 関 係 各 部 局 長 前 回 課 題 申 込 責 任 者 課 題 採 Powermate CPA1882054 Parts list Copyright © All rights reserved.
Failed to retrieve file