Home
AEG Protect Home. 600 VA
Contents
1. 11 8 Q Power switch of the UPS mains switch Green LED Normal power mode Yellow LED Battery mode Red LED Warning failure Surge protected only receptacles without UPS protection Battery power supplied receptacles with UPS protection e g power failure Mains line for UPS with shockproof socket 230 Vac Input circuit breaker press button after possible execution reset RESET Overload protection for SAT TV SAT receiver F connector Overload protection telephone fax modem RJ11 connector RS232 communication interface Sub D9 USB interface 4 1 Specifications MODEL PROTECT HOME Type power i 600 VA 300 W UPS input Input voltage 230 Vac 1ph N PE Input voltage range 6 10 without battery mode Frequency 50 60 Hz 5 Hz auto selection UPS output Rated output voltage AVR technology 230 Vac Rated output voltage p Frequency 50 60 Hz 1 Hz in battery mode Default setting 50 Hz Transfer time output power rate 26A at 230 Vac Output Waveform Approximately sine wave Battery Sealed maintenance free A brand Battery type amount 1221 W 1 battery back up time at l deep discharge Recharge time to 90 of rated capacity Communication Bade USB and RS232 for status and measurement levels Shutdown software For all popular operating systems Compuwatch e q Windows Linux Mac on CD Protection Ov
2. The UPS does not contain any parts which require regular maintenance Bear in mind that the warranty will be invalidated if the unit is opened Do not install the unit in direct sunshine or in close proximity of heaters The unit is designed to be installed inside in heated rooms Never install the UPS in the vicinity of water or in an excessively damp environment Condensation may occur if the UPS is brought from a cold environment into the room where it is to be installed The UPS must be absolutely dry prior to start up As a result leave it to acclimatise for at least two hours e Never connect the mains input to the UPS output Ensure that no fluids or foreign bodies can penetrate the UPS Do not block the side air vents of the unit Keep children away from the unit and ensure that objects are never inserted through the vents Do not connect household appliances such as hairdryers to the UPS The mains connection should be near the unit and easily accessible to facilitate disconnecting the AC input or pulling out the plug During operation do not disconnect the mains connection cable from the UPS or from the socket outlet in the building shockproof socket otherwise the protective grounding of the UPS and all the loads connected to it will be cancelled Danger Electric shocks Even after the mains voltage has been disconnected the components within the UPS remain connected to the
3. declare under our sole responsibility that the product Uninterruptible Power Supply UPS Protect home type power 600VA to which this declaration relates is in conformity with the following standards or other normative documents EN 62040 1 1 2003 EN 50091 2 1995 clause 2 4 2 5 class A EN 61000 3 2 1995 EN 61000 3 3 1995 Following the provisions of directives 89 336 EEC EMC Directive T3 23 EEC Low Voltage Directive 93 68 EEC Marking Directive Year of labelling the CE Mark 216 Germany 39381 Warstein 03 12 2008 AEG Power Solutions GmbH AEG Power Solutions GmbH Quality Management Product Management Compact UPS mai Pf 5 Ba ey a side Filmar Schneider 2 1 2 2 Safety Important Safety Instructions Read these operating instructions carefully prior to commissioning of the PROTECT HOME UPS and observe the safety instructions Only use the unit if it is in a technically perfect condition and always in accordance with its intended purpose while being aware of safety and danger aspects and in accordance with the operating instructions Immediately eliminate any faults which could be detrimental to safety The following pictograms are used in these operating instructions to identify dangers and important information Danger Identifies risk of fatal injury to the operator Warning Identifies risk of injury and risk of damage to the unit and parts of the unit Information
4. along with the packing slip Subsequent claims cannot be considered The warranty does not apply for damage caused by non compliance with these instructions such damage also includes damaging the Q A warranty seal AEG will accept no liability for consequential damage AEG will rescind all obligations such as warranty agreements service contracts etc entered into by AEG and its representatives without prior notification in the event of maintenance and repair work being carried out with anything other than original AEG spare parts or spare parts purchased by AEG Handling PROTECT HOME is designed and constructed so that all necessary steps for start up and operation can be performed without any internal manipulation of the unit Maintenance and repair work may only be performed by trained and qualified personnel Hotline If you still have questions after having read these operating instructions please contact your dealer or our Hotline Phone 49 0 180 5 234 787 Fax 49 0 180 5 234 789 Internet www AEGppartnernet com Copyright No part of these operating instructions may be transmitted or reproduced by any electronic or mechanical means without the express prior written permission of AEG Copyright AEG 2009 All rights reserved 1 1 Certification AEG Power Solutions Declaration of Conformity Document No CE 0066 We AEG Power Solutions GmbH Emil Siepmann Stra e 32 D 59581 Warstein
5. of IT components and data security are guranteed The CompuWatch shutdown software supports different operating systems Windows 98SE ME Windows NT 2000 XP Linux Novell NetWare IBM AIX HP UX SUN Solaris Mac OS X and others Refer to the manual on the CD for details about installing the software on the various operating systems Download updates via www AEGpartnernet com gt gt PRODUCTS gt gt Software gt gt CompuWatch 19 Trouble shooting Connect the UPS lighting but audible properly to the mains according to the alarm is heard installation guide intermittently UPS is functioning UPS overload Verify that the load but audible alarm is matches the UPS heard periodically capacity specified in the Spec Communication Software not installed Check the setting of the lost between UPS well software and Computer Cable is not properly Check if the RS232 or connected USB cable is firmly connected to the COM1 COM or USB of the computer and confirm the setting Red LED is Hardware error inthe Contact dealer lighting alarm is UPS heard continuously If any abnormal situations occur that are not listed above please call the service centre immediately or contact our hotline see page 4 20 Guarantee certificate MOGs outset nana te E E E T CMO ce arsn cas onddamne manta E E eaa Dat OF purchase sincexactecdavasedqrsnamtenenadenoaneantsbanpettosamianienn Trading stamp Signatur
6. 1 Useful and important hints for the operation of the UPS e Safety Instructions for PROTECT HOME This chapter contains important instructions for the UPS PROTECT HOME These must be followed during assembly operation and maintenance of the uninterruptible power supply and the batteries The UPS carries high voltage Danger The unit may only be opened by trained and qualified personnel Repairs may only be carried out by qualified customer service staff gt gt gt The output may be live even if the UPS is not connected to the mains supply as the UPS has its own internal power supply battery For health and safety reasons the unit must be earthed correctly PROTECT HOME may only be operated with or connected to a 230 VAC mains with protective grounding using a mains connection cable with PE conductor included in the delivery that has been tested in accordance with German standards VDE Danger Risk of burning gt gt e The battery has powerful short circuit currents Incorrect connection or isolation faults can lead to melting of the plug connections sparking potential and severe burns The unit has a warning signal that sounds when the battery voltage of PROTECT HOME is exhausted or when the UPS is not working in its normal mode Observe the following safety instructions to ensure permanent operational safety of and safe work with the UPS Do not dismantle the UPS
7. AEG PROTECT HOME Thank you for purchasing the AEG UPS PROTECT HOME from AEG Power Solutions Safety information and operating instructions are included in this manual To ensure correct use of the UPS please read this manual thoroughly before operating it Save this manual properly 1 Notes on these Operating Instructions Duty to Provide Information These operating instructions will help you to install and operate the Uninterruptible Power Supply UPS PROTECT HOME safely and properly and for its intended purpose These operating instructions contain important information necessary to avoid dangers during operation Please read these instructions carefully prior to commissioning These operating instructions are a composite part of PROTECT HOME The operator of this unit is obliged to communicate these instructions to all personnel transporting or starting PROTECT HOME or performing maintenance or any other work on the unit Validity These operating instructions comply with the current technical specifications of PROTECT HOME at the time of publication The contents do not constitute a subject matter of the contract but serve for information purposes only Warranty and Liability We reserve the right to alter any specifications given in these operating instructions especially with regard to technical data and operation Claims in connection with supplied goods must be submitted within eight days of receipt
8. arging the battery Battery as energy storage medium for bridging mains failures for supplying the inverter Inverter for the supply of connected loads with alternating voltage in case of power failure e Switch device to switch the loads onto the inverter in case of power failure The UPS is connected to a shockproof socket between the public utility s mains and the loads to be protected Under normal operating conditions i e if PROTECT HOME is supplied with mains voltage the battery charger will ensure that the battery is always completely charged In this case the connected loads are supplied via the line filter with offers a effective protection against mains over voltage and mains voltage peaks In the event of a mains failure PROTECT HOME supplies voltage until the battery is discharged allowing you to shut down your IT system properly and switch it off The standby time mainly depends on the connected loads If the mains power supply is back to normal values the UPS will switch back the loads to mains supply The battery charger will then recharge the battery For safety reasons as required by German standards VDE the mains input in the unit will be disconnected by a two pole switch in the event of a mains failure Energy back feed to the mains and voltage supply to the pins of the mains connector are thus reliably avoided 4 UPS overview Connections Operation Display Elements Top view Side view
9. around the unit which is free from excessive dust corrosive fumes and conductive contaminants K Do not use the UPS in environments with high temperatures or humidity Charging The PROTECT HOME is shipped from the factory with its internal battery fully charged however some power may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 to 10 hours with no load no electrical devices such as computers monitors etc 5 4 5 5 gt 8 hours Computer connection Connect one computer related device into one of the battery supplied receptacles on the top of UPS PROTECT HOME provides four receptacles three battery supplied receptacles and one surge protected only receptacles marked Battery Backup Connection of peripheral devices An additional outlet marked Surge Only with protection against over load but without UPS protection allows the supply of additional peripheral devices Especially powerful loads should be connected here Keep in mind that these receptacles do not provide any power during a power failure 15 5 6 5 7 5 8 Do not plug heaters or other large electrical device with high power consumption into the UPS The power demands of these devices will overload and can execute the input fuse of the PROTECT HOME Mo
10. battery and can thus cause electric shocks It is therefore imperative to disconnect the battery circuit before carrying out any maintenance or repair work If it is necessary to replace the battery or carry out maintenance work this must be done by or under the supervision of a person familiar with batteries and the necessary safety precautions Only authorised persons are allowed in the vicinity of the batteries When replacing the battery the following must be observed Only ever use identical maintenance free sealed lead batteries with the same data as the original battery Danger Explosive Never throw batteries into open fire Never open or damage batteries Electrolyte may leak out and damage skin and eyes It may be toxic Batteries can cause electric shocks and high Jn short circuit currents Therefore take the following safety precautions when working with batteries Take off watches rings and other metallic objects Always use tools with insulated handles For personal safety reasons never switch on the main switch when the mains connector of PROTECT HOME is disconnected 3 System Description PROTECT HOME is an uninterruptible power supply UPS for essential loads such as personal l computers PCs satellite TV s telecommunication equipment and similar devices It consists of Mains filter in the mains input incl mains energy back feed protection Battery charger for ch
11. dem Phoneline Connection Plug incoming internet line into the In socket at the side panel of the PROTECT HOME Incoming phone fax modem line Use one more internet line cable and plug one end of the internet line cable to the Out socket at the side panel of the UPS Satellite TV protection Connect the incoming antenna line with the F connectors optional via adapter plugs IEC in the IN socket on the rear of your PROTECT HOME Use the second antenna line and connect the Out socket with the Receiver Decoder TV etc Out yr CI eeo USB and serial cable computer connection To allow for unattended system shutdown for your operating system connect the USB or the RS232 serial cable both part of the packing as shown below For the USB serial cable just simply plug into the UPS and PC 5 9 5 10 5 11 RS232 connector The connection vie the USB connector will be auto detected Turn On Off To turn on the PROTECT HOME press the on off switch To turn off the PROTECT HOME press the on off switch again DC Start Function The DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS To protect yourself never switch on the main switch when the PROTECT HOME is not connected to the mains Deep discharge protection The UPS provides a deep discharge pr
12. e Specifications are subject to change without notice AEG Power Solutions AEG Power Solutions GmbH Emil Siepmann StraBe 32 59581 Warstein Belecke Germany Operating Instructions UPS BAL 8000025758 01 EN 21
13. erload and short circuit protection Surge protection for Telephone fax modem RJ11 SAT receiver F connector es a h Backup mode Yellow LED 12 Operating 5 g temperature range ei Relative humidity 20 90 Protection type IP 20 Audible noise 1 m distance ROOBA 4 shockproof sockets Outlets 1 x with surge protection 3 x additional UPS outlets Guidelines The PROTECT HOME complies with the product norm EN 50091 The CE symbol on the unit certifies the compliance to the EG guidelines for 73 23 EEC low voltage and for 89 336 EEC electromagnetic compatibility EMC when following the installation instructions in the manual For the 73 23 EEC low voltage guidelines Reference number EN 62040 1 1 2003 For 89 336 EMV guidelines Reference number EN 50091 2 1995 EN 61000 3 2 1995 EN 61000 3 3 1995 i Warning 1 This is a class A UPS product In a domestic environment this product may cause radio interference in which case the user may be required to take additional measures 13 5 1 5 2 5 3 Set Up and Operation Installing the UPS is as easy as following the steps shown Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase Placement Install the UPS unit in any protected environment that provides adequate airflow
14. otection function To protect the battery the deep discharge protection is activated before the battery is completely discharged 17 9 12 Battery removal Battery replacement should be performed by qualified service personnel Keep unauthorized persons away from the batteries Disconnect all power sources before battery replacement Follow Fig 1 below to remove the screws located on the bottom of the UPS to open the battery cover Fig 1 After removing the battery cover gently extract batteries from the case Follow Fig 2 Disconnect the two connecting wires from the batterie and replace with the same battery type Fig 3 P hoy gt SX Z Fig 3 Replace the batteries following the inverse sequence Take care to connect the and poles correctly 18 5 13 Shutdown and UPS management software The CompuWatch software specially developed for these purposes by AEG continuously checks the mains supply and the UPS status tH UPS Moniter E E ei Fig Yer Chart Functens Helg wje al me e m countPF 2 eu o a0 IE Status Chart Encipishs te ivi Evan AEG 04 25 2009 Stata Meemabatrias art Irfermatgn Verbindung zer WS hergertali Power Solutions USY Status 04 20 2003 ASAE Auwslasiunrg Hormalbetriet IHY 49 0 HE hormai 8 Minuten it t ev 25 0 E 235W ah In conjunction with the intelligent UPS this ensures that the availability