1. backplane port configuration refer to the specific module s documentation This chassis architecture facilitates a variety of applications including unmanaged out of band managed in band managed and multi port configurations Fig 2 Depicts the chassis backplane architecture Page 4 Slot 1 Connector A Backplane Link gt Slot 2 Connector Fig 2 2 Module Backplane Architecture 1 5 Application Examples 1 5 1 In Band Managed 10 100 Converter Application Fig 3 Depicts a typical in band managed fiber to UTP conversion at a Customer s Premises CP or at a remote network edge In band management is a desirable feature in these applications since it facilitates remote monitoring configuration and trap notification from the chassis VLANs can be used to separate the customer data from the management data This application uses an iConverter 10 100M module for media conversion and management and a 4TxVT 4 Port 10 100 switch module for added customer connectivity Both modules are plugged into the 2 Module chassis The 10 100M converter module features two front plane Ethernet ports 100 BASE FX fiber and 10 100BASE T UTP and two 10 100Mbps Ethernet backplane ports A and B Ports The 4TxVT module features four front plane Ethernet ports 10 100BASE T and two 10 100Mbps Ethernet backplane ports A and B Ports The user data flows between the fiber and UTP ports of the 10 100M a
2. CN Omnitron Systems Technology Inc iConverter 2 Module Power Chassis User Manual 140 Technology Dr 500 Irvine CA92618 USA Phone 949 250 6510 Fax 949 250 6514 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this module other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Caution All user required operations can be performed without opening the chassis Never attempt to open or remove the cover or tamper with the chassis There are no user replaceable or serviceable parts in this unit Equipment is not intended to be installed and used in a place home school or public area accessible to the general population Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM Or you may register your product on the Internet at http www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the produc
3. O Connect the power cables to the iConverter Chassis by fastening the stripped ends to the DC power connector WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker O Connect the power wires to the circuit breaker and switch the circuit breaker ON If any modules are installed their Power LED should indicate the presence of power Fig 7 Rear of 2 Module Chassis with DC Power Connector WARNING NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY OR FAN MODULE OPENING THE CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT Page 9 4 0 SPECIFICATIONS 2 Module AC 2 Module AC 2 Module DC 2 Module DC 8 5 watts 16 5 watts 6 6 watts 16 5 watts Model Number Standard 8230 0 8231 0 8235 0 8236 0 Dying Gasp e 1 8231 1 8235 1 8236 1 Module Capacity Module Capacity Power Supply Fixed Internal Capacity Input Power 100 to 240VAC 100 to 240VAC Requirements 50 60Hz 50 60Hz typical 0 5A 120VAC 0 5A 120VAC Chassis Type 18 to 60VDC 18 to 60VDC 48VDC 1 0A 48VDC 2 0A W 6 7 x D 5 51 x H 1 87 2 6A 3 3VDC 5A 3 3VDC 2A 3 3VDC 5A 3 3VDC Backplane Power 1 5A per slot 2 5A per slot 1 5A per slot 2 5A per slot presons 2 5 lbs Compliance UL CE FCC Class A NEBS Level 3 Standard 0 to 50 C Tempera
4. he same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor O The standard operating temperature of this equipment is 0 to 50 degrees C If installed in a closed or multi module rack assembly the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C See specifications on page 10 for wide temperature ranges O Installation of the equipment should be such that the air flow in the front back and side vents of the chassis are not compromised or restricted O Never use this equipment to carry any weight except its own Never use it as a shelf to support weight of other equipment Page 8 3 4 DC Powered Chassis Mounting O Locate the DC circuit breaker of the external power source and switch the circuit breaker to the OFF position O Prepare a power cable using a three conductor insulated wire not supplied with a 14 AWG gauge minimum Cut the power cable to the length required O Strip approximately 3 8 of an inch of insulation from the power cable wires
5. ise Local Area Network LAN or Metropolitan Area Network MAN applications where remote management and explicit demarcation between the service provider s equipment and customer s equipment is required Fig 1 2 Module Chassis Shown without modules installed This User Manual describes the following models Configuration 2 Module AC 2 Module AC 2 Module DC 2 Module DC g 8 5 watts 16 5 watts 6 6 watts 16 5 watts gt Module Chassle 8230 0 EEE 8236 0 2 Module Chassis with Dying Gasp Support Wall Mount Hardware Kit 8249 0 8249 0 8249 0 8249 0 Blank Module Panel 8090 0 8090 0 8090 0 8090 0 For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models 1 1 Dying Gasp Trap The 8230 1 8231 1 8235 1 and 8236 1 chassis feature Dying Gasp Trap which reports loss of power input or chassis power supply failure This feature requires an iConverter management module be installed in the chassis When power failure occurs the chassis reserves enough power to keep the installed modules running in order to send a final SNMP alert to the management software Page 3 1 2 Terms Backplane A printed circuit board which is permanently mounted inside the chassis and is populated with receptacle connectors into which modules are inserted Module An iConverter plug in card positioned into a slot location and inserted into a backplane connector Modu
6. le Guide A mechanical channel guiding module insertion into a backplane connector Slot A single chassis position consisting of a backplane connector and its associated module guides A Link A backplane slot to slot connection that provides Ethernet connec tivity between adjacent slots A Port An interface on a module capable of Ethernet traffic via the backplane s A Link Notes 1 Other iConverter multi module chassis models also support a backplane B Link This feature is not required on the 2 Module Chassis 2 Other modules support a B Port In the application drawings in this manual the B Ports depicted are not connected 1 3 Mechanical Description The 2 Module chassis consists of a fixed internal AC models 8230 0 8230 1 8231 0 and 8231 1 or DC models 8235 0 8235 1 8236 0 and 8236 1 power supply that provides power to the chassis two 2 backplane connectors 1 4 Backplane Architecture The chassis features two 2 module slots numbered 1 top slot and 2 bottom slot As modules are inserted into the chassis slots they are seated into the slot connectors The two slots are connected using the A Link which provides Ethernet connectivity between the two slots When modules with A Port capability are inserted into the adjacent chassis slots they can connect their Ethernet data using their A Ports and the A Link Note Not all modules support and have backplane ports To find out about each specific module s
7. nd 4TxVT via the backplane The management data flows between the fiber and all the UTP ports in band Using a management VLAN the management data is recognized by the 10 100M module and is not shared by the other ports This configuration provides the network administrator with the ability to manage and maintain the converter chassis at the remote location Chassis Backplane Note that the 2 Module Chassis does not include the B Backplane Link Internal 10 100 Internal 10 100 switch chip switch chip Fiber UTP 4 port 10 100 UTP 100 port 10 100 port Switch 10 100M Module 4TxVT Module Fig 3 In Band Managed 10 100 Converter Application Page 5 1 5 2 Out of Band Managed 4 Port Switch Application Fig 4 Depicts a typical managed switch application This application uses a 4TxVT 4 Port 10 100 switch module and an iConverter Network Management Module NMM for management Both modules are plugged into the 2 Module chassis The 4TxVT features four front plane 10 100BASE T UTP Ethernet ports and two 10 100Mbps Ethernet backplane ports A and B Ports The NMM features a 10BASE T front plane port and a 10Mbps Ethernet backplane A Port Out of band management is provided by connecting to the front plane port on the NMM module The management data is separate from the user data on the 4TxVT This configuration provides the network administrator with the ability to efficien
8. quipment should be such that the air flow in the front back and side vents of the chassis are not compromised or restricted Never use this equipment to carry any weight except its own Never use it as a shelf to support the weight of other equipment 3 2 AC Powered Chassis Mounting m Attach the AC power cords to the back of the Power Receptacle and plug into the AC outlet Any installed Converter modules will illuminate the power LED Fig 6 Rear of 2 Module Chassis with Power Cord 3 3 DC Powered Chassis Site Preparation D D Power source should be available within 5 ft of the chassis The over current protection for connection with centralized DC shall be provided in the building installation and shall be a UL listed circuit breaker rated 20 Amps and installed per the National Electrical Code ANSI NFPA 70 This equipment requires 18 60VDC 1 0Amp 8235 or 2 0Amp 8236 rated power Appropriate overloading protection should be provided on the DC power source outlets utilized WARNING Only a DC power source that complies with safety extra low voltage SELV requirements can be connected to the DC input power supply Page 7 WARNING REGARDING EARTHING GROUND o This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected This equipment shall be located in t
9. t must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory iConverter 2 Module Power Chassis User Manual 1 0 GENERAL DESCRIPTION The iConverter 2 Module Power Chassis is powered by a single internal universal AC or DC power supply and can accommodate up to two iConverter media converters It is ideal for enterpr
10. tly and cost effectively manage a small 4 port workgroup switch A Link Chassis Backplane Note that the 2 Module Chassis does not include the B Backplane Link Internal 10 100 switch chip NMM UTP 4 port 10 100 UTP 10 port Switch NMM Module 4TxVT Module Fig 4 Managed 4 Port Switch Application 2 0 UNPACKING VISUAL INSPECTION AND INVENTORY Review contents The following items should be included O iConverter 2 Module Power Chassis O One AC power cord AC MODULES ONLY O One DC power connector DC MODULES ONLY O User Manual Inspect equipment and immediately report any damage or discrepancies to Omnitron at 949 250 6510 If equipment is damaged do not apply power to the equipment Page 6 3 0 SITE PREPARATION AND INSTALLATION 3 1 AC Powered Chassis Site Preparation o E o o o Power source should be available within 5 ft of the chassis and installed per the National Electrical Code ANSI NFPA 70 This equipment requires a 100 240VAC 0 5Amp 50 60Hz power outlet Appropriate overloading protection should be provided on the AC power source outlets utilized The standard operating temperature of this equipment is 0 to 50 degrees C If installed in a closed or multi module rack assembly the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C See specifications on page 10 for wide temperature ranges Installation of the e
11. ture Wide 40 to 60 C Storage 40 to 80 C Humidity 5 to 95 non condensing 100m to 4000m MTBF hrs 151 000 413 000 329 000 538 000 The 8231 and 8236 have internal temperature controlled fans The fan will turn on when the chassis internal temperature is greater then 40 C Under normal operating temperature the fan is off Page 10 5 0 CUSTOMER SUPPORT INFORMATION If you encounter problems while installing this product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 4500 Irvine CA 92618 USA Email support omnitron systems com URL www omnitron systems com Page 11 040 08230 001J 02 08 Page 12