1. HDX forces the UTP port to operate in Half Duplex Adjust the UTP Full Half Duplex DIP switch to match the duplex mode of the connected UTP device SW6 SW7 SW8 LINK MODES These three DIP switches configure the link mode settings The following table details possible Link Mode DIP switch configurations Left Factory Default AN Man Fiber Auto Negotiation Fiber Manual Negotiation AN Man UTP Auto Negotiation J UTP Manual 1000 10 100 UTP 1000Mbps UTP 10 100Mbps FDX HDX UTP Full Duplex UTP Half Duplex See Link Mode Selection 100 10 UTP 100Mbps UTP 10Mbps SW7 Figure B DIP Switch Bank 1 DIP SWITCH BANK 2 SW1 SW2 BACKPLANE ENABLE When the DIP switch is in the LEFT DS position factory default the Backplane Port of the GX TM is isolated from the chassis Ethernet Backplane When the DIP switch is in the RIGHT EN position the Backplane Port is enabled This allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Link A or B depending on the switch setting SW3 PAUSE DISABLE ENABLE OFF PAUSE When the UTP port is operating in Auto Negotiation mode it advertises for Pause based on the Pause Disable Enable Off Pause DIP Switch setting Setting the Pause DIP switch to the Off position eae enaeo oa Cet Factory Default Rim factory default forces the UTP port Swi Japs Pon A Disables AEN Pon AErabed to nego
2. DURE 1 Configure DIP Switches 2 Install Module in Chassis and Connect Cables 3 Configure Module via Command Line Interface 4 Verify Operation 1 CONFIGURE DIP SWITCHES DIP SWITCH BANK 1 SW1 FIBER AUTO MANUAL NEGOTIATION Suini AN MAN AE ns 3 When this DIP switch is in the LEFT AN position Switch 1 f factory default the fiber optic port automatically 77 _ determines the duplex and pause modes of the connecting fiber optic device If the connecting fiber optic device cannot provide the proper signal to indicate its own mode of operation the DIP switch should be set to the RIGHT fiber optic Man position NOTE When the fiber optic port operates in Auto Negotiation mode the port advertises for Pause When the fiber optic port operates in Manual mode Pause is disabled NOTE The fiber optic port of the GX TM is always in Full Duplex mode SW2 UTP AUTO MANUAL NEGOTIATION AN MAN When this DIP switch is in the LEFT UTP AN position factory default the UTP port automatically determines the Speed Duplex and Pause mode of the connecting UTP device If the connecting UTP device cannot provide the proper signal to indicate its own mode of operation then the DIP switch should be set to Man position Manual mode requires manually configuring the UTP port to match the Speed and Duplex mode of the connecting UTP device using the 10 100 and FDX HDX DIP switches Figure A DIP Switc
3. c Connect the UTP port via a Category 5 cable to a 10BASE T 100BASE TX or 1000BASE T Ethernet device d Connect an appropriate multimode or single mode fiber cable to the fiber port of the installed module It is important to ensure that the transmit TX is attached to the receive side of the device at the other end and the receive RX is attached to the transmit side Single fiber SF media converter models operate in pairs The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end 3 CONFIGURE MODULE VIA COMMAND LINE INTERFACE To access the Command Line Interface CLI connect the GX TM RS 232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal The Console Port DCE is a mini DIN 6 female connector which can be changed to a DB 9 connector with the included adapter The GX TM Console Port is a standard asynchronous serial interface Start HyperTerminal and select the correct COM Port in the HyperTerminal Connect To window Set the serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE Once connected press lt ENTER gt to bring up a command line prompt on the attached PC The CLI interface allows for the detailed configuration of the module It is recommended to configure the module with an IP address associated with the attached netwo
4. h Locations SW3 UTP SPEED GIGABIT 10 100 1000 10 100 When the 1000 10 100 DIP switch is in the 1000 position factory default the UTP port always operates in 10 100 1000Mbps Auto Negotiation mode The UTP port auto negotiates to a speed of 10Mbps 100Mbps or 1000Mbps with the connected UTP device In this mode the UTP AN Man and UTP 100 10 DIP switches have no effect When the 1000 10 100 DIP switch is in the 10 100 position and the UTP AN Man DIP switch is in the Man position the UTP port operates at the Speed Duplex and Pause modes set by the 100 10 FDX HDX and Off Pause DIP switches When the 1000 10 100 DIP switch is in the 10 100 position and the UTP AN Man DIP switch is in the AN position the UTP port maximum auto negotiation setting for the Speed Duplex and Pause mode is determined by the 100 10 FDX HDX and Off Pause DIP switches SW4 UTP 100 10MBPS 100 10 When the UTP AN Man DIP switch described above is in the manual Man position the 100 10 DIP switch determines the speed of operation for the UTP port Set the 100 10 DIP switch to match the speed of the connected UTP device SW5 UTP FULL HALF DUPLEX FDX HDX Setting the UTP Full Half Duplex DIP switch to the LEFT UTP FDX position factory default forces the UTP port to operate in Full Duplex Setting this DIP switch to
5. or Straight through connection SW6 UTP MANUAL CROSSOVER X When this DIP switch is set to MANX the UTP Manual Crossover Switch is enabled Set this DIP switch to factory setting when connecting the UTP port to a workstation or set it to X when connecting to a hub or switch Only use this setting in 10 100Mbps Manual negotiation mode SW7 SW8 RESERVED These DIP switches are for factory use only and must always remain in the LEFT position factory default 2 INSTALL MODULE IN CHASSIS AND CONNECT CABLES a Carefully slide the module into an open slot in the chassis Align the module with the installation guides and ensure that the module is firmly seated against the backplane Secure the module by fastening the front panel thumbscrew push in and turn clockwise to tighten to the chassis front Verify the Pwr LED is ON indicating the chassis is powered b When using a GX TM SFP model 8939 0 insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the GX TM NOTE The release latch of the SFP Fiber transceiver must be in the closed position before insertion
6. rk Also SNMP traphost address should be configured if the module is managed with an SNMP based Management System See the GX TM User Manual for complete information 4 VERIFY OPERATION 7 Once the module has been Legend Color oe On Blinking State No power installed and configured per steps Power Pwr No power On Module has power 1 3 verify the module is Se On Power available from f P Suppl assis Power installed Power Supply X operational by viewing the LED tatus X gt Amber Supply not installed Blinking No power available ind icators from installed Power Supply X 1000Mbps On Fiber Link The Power LED indicates the ores ee ner eena Blinking Fiber Data Activity module is receiving power from the eas g p Chassis in Slave on Chassis Master Mode chassis Master Slave Green Mode Blinking Operating in OAM BP Mode The Fiber Optic link LED indicates i UTP port Not linked at On UTP linked at 100Mbps the fiber optic connection has been a Green 400Mbps Blinking UTP Data Activity established Verify the Link Mode UTP port com Green Not linked at On UTP linked at 1000Mbps 1000Mbps Blinking UTP Data Activity selection is set to Link Segment oe LS Until a stable link IS 10 Green Not linked at On UTP linked at 10Mbps established leave the Link Mode 400 1000 10M Brinking UTP Data Activity bps configured for LS After a Link UTP port Half Duplex when On Full Duplex
7. tiate to No Pause Setting this f sw2 B DS Pon B Disabled B EN Port B Enabled allows the UTP port to negotiate to Symmetrical Pause Asymmetrical a ee Only UTP Auto Crossover UTP Manual Crossover X UTP port is operating in Manual SW7 Reserved Reserved mode Pause is disabled NOTE When the Fiber optic port Reseed Reserved operates in Auto Negotiation Figure C DIP Switch Bank2 mode the port advertises for 9 Pause When the Fiber optic port operates in Manual mode Pause is disabled SW4 MASTER SLAVE When the GX TM module is installed in a chassis with an iConverter Network Management Module NMM set the DIP switch to the LEFT M SL position factory default the assignment of mastership is automatically negotiated by the installed management modules To designate the GX TM module as the master of the chassis set the DIP switch on the module to the LEFT M SL position and set the other installed management modules DIP switches to the RIGHT SL position to enable Slave Only mode SW5 UTP 10 100 AUTO MANUAL CROSSOVER AX MANX The 10 100 Auto Crossover feature is only available when the UTP port is operating in 10 100 Auto Negotiation mode When AX MANX DIP switch is set to AX factory default the 10 100 UTP Auto Crossover feature is enabled When it is set to MANX the UTP Manual Crossover DIP switch is enabled to allow the user to manually set either a Crossover
8. when any UTP Full Duplex Green any UTP link is link is active presence is established the Link DX active Mode selection can be modified Figure D LED Indicators The UTP link LED indicates the module has established a connection across its UTP port Form 040 08920 002 12 07 Omnitron Systems Technology 140 Technology Dr 500 Irvine CA 92618 949 250 6510 tel 949 250 6514 fax www omnitron systems com osr Omnitron Systems Technology Inc iConverter GX TM Plug in Module QUICK START GUIDE The Omnitron iConverter GX TM Plug In media converter and Network Interface Device NID provides 10BASE T 100BASE TX or 1000BASE T UTP to 1000BASE FX fiber media conversion The GX TM conforms to Ethernet in the First Mile EFM fiber standards to support Fiber to the X FTTX Metropolitan access and Enterprise LAN networks Built in Operation Administration and Maintenance OAM functionality enables the GX TM to operate as a managed copper demarcation point at the customer premises and network edge offering Quality of Service capabilities The GX TM module can be managed using Omntron s NetOutlook SNMP Management Software 3rd Party SNMP Client Telnet or the Command Line Interface CLI For more information including the complete User Manual on the GX TM Plug in module access Omntron s documentation download web page to view all relevant documents http www omnitron systems com downloads php INSTALLATION PROCE

Download Pdf Manuals

image

Related Search

Related Contents

Sony CDX-C780 User's Manual  Microcode patch device and method for patching microcode using  Operating Instructions  As Tecnologias TDMA e GSM Relacionadas com o Roubo  This is a troubleshooting guide for those who encounter problems to  121    Manual de Usuario Rol: Asociado v1.0-E02.001-001  Impresora EasyCoder® PD41 Manual del operador  