Panasonic EW3153W blood pressure unit

image

Contents

1. when in a moving vehicle Blood pressure will be lower than usual after taking a bath after drinking alcohol Measurements may be impaired if this unit is used near a television microwave oven X ray equipment or other devices with strong electrical fields To prevent such interference use the unit at a sufficient distance from such devices or turn the devices off This unit is designed for use by adults Consult with your physician before using this unit on a child Do not use on infants or toddlers This unit is not suitable for continuous monitoring during medical emergencies or operations Do not use the unit for any purpose other than measuring blood pressure Do not use the unit together with other devices 10 Improper handling of batteries may result in battery rupture or in 5 corrosion from battery leakage Please observe the following to ensure proper use of batteries a Be sure to turn off the power after use b Do not mix different types or sizes of batteries c Change all batteries at the same time Do not mix old and new batteries d Be sure to insert batteries with correct polarity as instructed e Remove batteries when they are worn out and dispose of them properly according to all applicable environmental regulations Do not disassemble batteries or throw them into a fire g Do not short circuit batteries h Do not attempt to recharge the batteries included with the unit ra Il Precaution
2. 5 6 oz not including batteries Dimensions Main unit 11 x 6 x 11 28 3 cm x 16 9 cm x 28 1 cm Wireless display 594 x 31 4 x 2 14 6 cm x 8 4 cm x 6 8 cm Protection against Internally powered equipment Type BF electric shock applied part AC adapter Input AC 120v 60 Hz Output DC6v20A 29 E Toe A aa Q Why are the blood pressure values measured at home different from those measured at the doctor s office A Blood pressure varies in a 24 hour period In addition it can vary greatly depending on the weather your mental state amount of exercise etc In particular there is the phenomenon of White uniform hypertension at doctor s offices where the blood pressure measured in a doctor s office is higher because of stress or anxiety In addition if the blood pressure measured at home is sometimes higher and sometimes lower than the blood pressure measured at the doctor s office the following can be considered Please pay attention to these points when taking measurements 1 Measuring posture was poor Did you take measurements while leaning forward with your body at an angle 2 Measurements were not taken at the upper arm Please take measurements with your elbow in the arm support of the main unit See pages 15 17 3 Were you anxious or upset during measurements Before taking measurements take 2 or 3 deep breaths and relax so that your blood pressure stabilizes Q
3. Do not use a cellular phone near the main unit 17 ERE Positions of the main unit and the wireless display Your body reflects infrared Face the wireless display towards you rays into position within reach of your hand within approx 23 60 cm Do not put your hand or any other objects in front of the wireless display The main unit and the wireless display communicate with each other using infrared rays Infrared rays are transmitted from the For the measurement on transmitter on the side panel of the main your left arm unit and reflected on your body and then received on the bottom of the front panel of The same range the wireless display The units may not restrictions as the communicate due to improper positioning of measurement on your left the wireless display or other environmental arm is applied conditions lighting sunlight etc In those cases place the wireless display closer to your body If you place the wireless display where it cannot receive signals from the main unit and then press the On Off and the Start button the main unit starts a measurement but nothing appears on the wireless display If the wireless display is placed where it can For the measurement on receive signals from the main unit while the your right arm measurement is executed results are displayed If the wireless display cannot receive signals from the main unit the X mark flashes
4. However if this mark continues to be displayed in subsequent readings please consult with your physician This function is designed to act as a guide to help you to obtain accurate readings Please see pages 15 18 If the CNM mark is frequently displayed please consult a health professional for your health condition Don t try to interpret readings or attempt to treat any condition yourself Always follow the guidance of a health professional 21 Erm Alarm function signals high blood pressure Blood pressure values for both systolic and diastolic readings are determined and indicated via 4 mark in the display as being within normal or hypertensive ranges based on definitions and classification of blood pressure levels by the JNC 7 Moreover when blood pressure is in the high range the reading displayed on screen flashes on and off to alert user According to JNC 7 Classification values consistently in excess of 140 mmHg Sys and or 90 mmHg Dia are considered to constitute high blood pressure Blood pressure 4 mark sign positions mmHg lt 4 Diastolic 140 Hypertension h y Oe Stage 1 Stage 2 i O7 a 4 4 Yellow Prehypertension 90 J lt 120 140 mmHg Systolic sys 4 22N Blood pressure readings will flash for approx 6 seconds Aea Her ft when in the high blood pressure range a Saf Systolic blood pressure 140 mmHg and over wA j if Diastolic
5. moisture causing a leakage electricity fire 12 When unplugging the AC adapter do not pull on the cord Always grasp the AC adapter body and unplug it Failure to do so could result in the risk of electric shock short circuiting or fire 13 Do not insert any object in the AC adapter or allow debris to collect on it Doing so could result in the risk of electric shock short circuiting or fire 14 Do not scratch damage modify forcibly bend pull or twist the AC adapter cord In addition do not place heavy objects on top of the cord 6 or pinch it with objects Do not wrap the cord around the main unit and the AC adapter Doing any of these things may result in the risk of fire or electric shock 15 Do not step on the AC adapter Doing so may cause an accident or injury 16 Do not use a voltage converter Doing so may cause fire or electric shock 17 This AC adapter is designed for use only with Panasonic Blood Pressure Monitor model EW3153 Use with other electrical devices may result in death or serious personal injury 18 ALWAYS unplug the AC adapter from the power outlet before performing maintenance 19 Do not let this product to be used by children 20 Do not let this product to be used by people who cannot express their feelings or who cannot operate the product by themselves Do not use the unit on an arm where a catheter has been inserted Such use may result in an accident or injury 21 Use AC adapter only wi
6. on the wireless display on the display panel as shown in the figure on the left In this case set the wireless display in the proper position EXE 18 BEL dare a ACECHA continued Measurement E 1 Press the On Off and Start button on the main P unit 1 After the entire display on the wireless display has been lit the pressure cuff will be tightened Painia fm automatically et IV 2 Pressurization will be performed automatically Ar TDT and measurements will be taken S pmr It may take about 1 second for the wireless display ern VIBB to turn on after pressing the On Off and the Start The entire display button This is not abnormal will light for approx The angle of the main unit may change slightly eee while pressurizing This will not affect accuracy 2 When measurement has been completed the blood pressure and pulse values will be displayed The cuff will loosen after the measurement a 6a result has been shown for about 5 seconds The pressure cuff The blood pressure indication 4 mark will flash Ekot for 6 seconds then stay lit If the measurement is v i high it will also flash for 6 seconds to indicate high blood pressure See page 22 e The f mark will light For storing measurement values see page 24 e The pulse rate value is the beats per minute calculated based on the pulse rate during oer Ry measurement e neart mar Py j i will blink when pu
7. when The SS mark flashes you have tensed the muscles in your hand even though did not Relax the muscles in your hand and take move my arm or body the reading again See pages 15 17 20 Varying sounds and e Changes in operating sounds and pressurization speeds pressurization speeds are normal and occur occur during inflation of due to the fact that measurements are the cuff being made as the cuff is being inflated The wireless display is lost Take it to the store where it was purchased A for testing and repairs Instrument is broken g P If the unit still appears to provide unusual or erroneous readings consult your physician If the unit does not appear to be functioning properly contact Panasonic at 1 800 338 0552 Ere 34 For questions or assistance with your blood pressure monitor call us at 1 800 338 0552 Panasonic Consumer Electronics Company Division of Panasonic Corporation of North America One Panasonic Way 1H 1 Secaucus NJ 07094 No 1 EN SP XU Printed in China 2008 Matsushita Electric Works Ltd All Rights Reserved Impreso en China
8. Calling up Blood Pressure Readings __ Up to 90 readings each can be stored in the memory for two people Storing blood pressure readings All data is retained even when the batteries go flat or are changed When measurements are taken and no date has been set the date and time will be displayed as on the wireless display mm 1 Mpulse min Lt ot m a 2 M R 1 v 1 imme id min N Pulse min N2 Pulse min fae ee lha D After approx 2 seconds nE After approx 2 seconds Yea l He DEn After approx 2 seconds 1 After measurement has been completed the 3 mark will be lit up Press the user selection button on the wireless display to select the desired user To select User f To Step 2 To select User f Press the user selection button Press the Memory Recall button Memory storage is completed A total for f and Q of 90 readings can be stored in memory Readings over the memory capacity will be recorded over the oldest measurement in memory Readings cannot be saved when a measurement has been unsuccessful display of the error mark L iZ for blood pressure readings Readings can be saved however when the E mark is displayed for the pulse rate The memory number measurement date and time are alternately displayed in approximately 2 seconds EXE 24 BU Stori
9. Deleting all data stored in memory 1 Recall the user whom you want to delete using the user selection button 2 Recall stored data using the Memory Recall button 3 Press the Memory Recall button again and hold it for approx 3 seconds until all readings are deleted NOTE Readings from individual measurements cannot be deleted 4 If everything has been deleted the selected f or 4 mark and 09 will be displayed 26 EI Comparing AM and PM Average Systolic Blood Pressure Average AM and PM systolic blood pressure is displayed in order to allow you to compare readings from both time periods Use of the AM and PM average systolic blood pressure comparison function can aid in the detection of a blood pressure pattern known as early morning surge in which blood pressure rises rapidly in the morning AM PM comparison can only be done when the date and time have been set up These can be compared after readings have been saved and even when the unit is turned off 1 Press the user selection button to select the user for a comparison of average AM and PM systolic blood pressures Each time the button is pressed the user switches from one to the other 2 Press the r4 button e The average AM and PM systolic blood pressure for the selected user will be displayed AM 3 00 AM to 11 00 AM PM 6 00 PM to 2 59 AM The average systolic blood pressure recorded during the time
10. ENT OF HEALTH AND HUMAN SERVICES National Institute of Health National Heart Lung and Blood Institute National High Blood Pressure Education Program NIH Publication No 03 5233 May 2003 The display values are generally known but not proven to be an indicator of your blood pressure The EW3153 is not intended to be used as a diagnostic device Contact your physician if prehypertensive or hypertensive values are indicated I Table of Contents Es laiido e leo tko area a E A inna daveniGn spacial aoiaacenaas Basics of Blood Pressure us Important Instructions Before US cesssseesseseessetenteessoressseesseesseesons 4 Precautions to Ensure Safe Reliable Operation eeeeeeeeeereereeneeeee 6 Easily Check Your Blood Pressure Readings Against the JING 7 Classification scsissssiiiann Asta sini nitein ates Preparations Prior to Taking Measurement cece eeeeeeeeeeeeeeeeees Parts Identification Sioen esen aiana EENAA E EEVEE REEERE SES When Using the Main Unit with the AC Adapter When Using the Main Unit with Batteries Inserting the Batteries into the Wireless Display Setting the Time and Date ss nsssesieinenneriertnstrsttnstnsttetnnnnnrnnnnnnnnnrnn nt TAKING a Readingi sisssipiarsrresiiaitisusiiraeirri srei si Storing and Calling up Blood Pressure Readings vs Comparing AM and PM Average Systolic Blood Pressure 0 6 27 AMOM USE Aetsetese cect T a os celuessdueaydeuval
11. Panasonic Instructions Upper Arm Blood Pressure Model EW3153 Before operating this device please read these instructions completely and save this manual for future use Panasonic Oscillometric Diagnostec Automatic Arm Blood Pressure Monitor Model EW3153 is a device intended to measure systolic and diastolic blood pressure and pulse rate of an adult individual by using a pressurized cuff on the arm The device is not intended for use on infants and children The device is designed for home use only not for ambulatory measurement measurement recorded continuously during the day Specification of this device including pulse rate 30 160 pulse min 5 are listed in page 29 Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standard Manual Electronic or automated sphygmomanometers If you suffer from disorder of heart rhythm known as arrhythmia only use this blood pressure monitor in consultation with your doctor In certain cases oscillometric measurement method can produce incorrect readings Flashing System for hypertensive readings are based on blood pressure values classified in the paper UNC 7 Express The Seventh Report of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure U S DEPARTM
12. Why do the main unit and the wireless display operate together even when they are separated A The main unit and the wireless display communicate using infrared rays Infrared rays are transmitted from the transmitter on the side panel of the main unit and reflected on your body and then received on the bottom of the front panel of the wireless display Q The SS mark does not light when an arm is moved A The ESS mark is a function to notify you that your arm is bent or to indicate extra loads on the pressure cuff Therefore it may not indicate motion bending an arm slightly etc If you are concerned about the result retry the measurement Ere 30 amp A continued Q 31 Since the SS mark was displayed retried the measurement by setting my arm on the unit properly But the indicated value is still higher than usual The SS mark is just a guide for the proper measurement method See page 20 If you correct your posture when the SS mark is displayed but the measured value is still higher or lower than usual retry the measurement The following causes are suspected e Did you measure properly in proper posture Measure as indicated on pages 15 17 e Measured immediately after smoking e Measured when irritated or emotional e Measured in cold environments e For persons who have a physical constitution with less fluctuation in the pulse rate e If you are concerned about the results retry the m
13. blood pressure 90 mmHg and over pusemin Snas Only when measurement is complete A 2 will appear on the display to indicate that measurement was unsuccessful and should be performed again Before performing another measurement always press the On Off and Start button to turn off the unit and make sure to allow a rest period of 4 to 5 minutes before starting again Please consult your doctor without delay if the blood pressure indicator repeatedly displays to elevated blood pressure values Ere 22 BEV date Wr Mat r el lave KEINE To interrupt measurements quickly Press the Quick air release button If pressure cuff will not deflate quickly enough even if the On Off and Start button is pressed press and hold the quick air release button on top of the unit The air will be released in approximately 4 seconds If the pressure cuff comes off 1 With the belt and seam 2 Press the pressure cuff into downwards slide the pressure the groove of the main unit cuff into the main unit Either the front or the back can be attached first Pressure cuff With the belt and seam downwards slide the pressure cuff into the main unit Check that the x pressure cuff is inserted in the groove on the main unit When re attaching be sure not to touch the inside of the main unit where the pressure cuff has been removed Doing so may result in an accident or injury 23 ERE I Storing and
14. e cers seucenevyeseesavarece Specifications y Q QUA wider eeivaien ws Care and Maintenance lt isccstesccssecssvccscees cas ccetessenacssenacdesenesctaceaeacsezarestestcs 32 MFOUDISSMOOUIMG ss oreset snzsicssecees sosinaecebaceaaieniacedaaesdbsadhbecasEestedasaemesseceistisacss 33 2 MS Tousen Thank you for purchasing the Panasonic Automatic Arm Blood Pressure Monitor EW3153 Measuring your own blood pressure is an important way of monitoring your health High blood pressure hypertension is a major health problem which can be treated effectively once detected Measuring your blood pressure between doctor visits on a regular basis in the comfort of your home and keeping a record of the measurements will help you monitor any significant changes in your blood pressure Keeping an accurate record of your blood pressure will help your doctor diagnose and possibly prevent any health problems in the future I Basics of Blood Pressure Your heart acts like a pump sending blood surging through your blood vessels each time it contracts Blood pressure is the pressure exerted by blood pumped from the heart on the walls of blood vessels Systolic pressure is the pressure exerted when the heart contracts and pumps blood into the arteries Diastolic pressure is the pressure exerted when the heart expands or relaxes When you or your doctor take your blood pressure both your systolic and diastolic pressures are measured If your blo
15. easurement after staying quiet for 4 to 5 minutes When should I measure my blood pressure We recommend three measurements a day First vss Upon Waking Because with almost no influence from body movement it s the blood pressure is closest to that at night Second Before Lunch Because it provides blood pressure values close to the highest of the day alice ieee At Bedtime So as to obtain data close to your average blood pressure values during the day This way by taking measurements morning noon and night you can use the unit to learn the patterns of and monitor your blood pressure e Use of the AM and PM average systolic blood pressure comparison function can aid in the detection of a blood pressure pattern known as early morning surge in which blood pressure rises rapidly in the morning See page 27 Care and Maintenance Ez Do not attempt to disassemble repair or modify the unit Doing so may cause fire or cause the unit to malfunction It may also lead to injury Do not apply excessive force to the unit or drop the unit e Doing so may cause damage Do not insert dust or foreign objects into the unit e Doing so may result in damage If the unit is stored at temperatures below the freezing point do not use it immediately Leave it in a warm place for at least an hour before use e If the unit is not allowed to warm up it may not pressurize Do not touch the unit when measurement is in p
16. lse The mark is displayed when pulse rate could not is detected during be measured pressurization Remove your arm from the main unit 3 4 To switch off the blood pressure monitor press 7 the On Off and Start button on the main unit e If you forget to switch it off the blood pressure monitor will switch off automatically after approximately 2 minutes e When the Adjust button 2 on the wireless display is pressed indications disappears but the power of the main unit is still on for about 2 minutes Movement detection function If movement is detected while measurement is being taken and more pressure is applied by the pressure cuff the mark will be displayed e Please redo blood pressure measurement again if the XSS mark flashes or is lit If the arm to which the pressure cuff is attached is moved while measurement is being taken e g the elbow is bent suddenly in some cases correct measurements may not be obtained e When movement has been detected during measurement the RSS mark flashes when the blood pressure reading obtained during that measurement is displayed If this reading is saved the SS mark will light whenever it is recalled Movement Mark Explanation z Movement has been detected cS The elbow has been bent suddenly xs im The upper arm has been tensed The arm has been moved etc mmHg i With correct posture please take the measurement again after measurement ha
17. main unit 3 Plug the power cord fully into the AC outlet 11 ER I When Using the Main Unit with Batteries Always use alkaline batteries 4 AA size Panasonic LR6 alkaline batteries e When replacing batteries always use 4 fresh alkaline batteries of the same type from the same manufacturer and replace them simultaneously 1 Turn the main unit over and 2 Ogo remove the battery cover by sliding it in the direction of Hill the arrow while pressing Dopo lightly on the A mark 2 Check the polarities of the batteries and install them correctly 3 Replace the battery cover and slide it closed Notes for using the main unit with batteries Approximately 150 measurements can be taken Depending on the conditions battery life may be dramatically shortened Use of the main unit with the dedicated AC adapter EW31555 included is recommended Replace batteries when The mark shown to the left appears during use e No display appears even if the On Off and Start button is pressed CAUTION e Always follow the cautions printed on the batteries e Check the polarities of the batteries and install them correctly Remove exhausted batteries promptly If the product will not be used for long periods of time remove the batteries first e Batteries should be used before their expiration date Use after the expiration date may result in injury or staining of the sur
18. ments should be taken using the same arm for comparative consistency Posture to obtain accurate measurements Measure on bare skin Put your elbow on the elbow rest Put your palm up and relax Stretch your back Place the wireless display where you can see it easily Do not put your hand or any other objects in front of the wireless display Cautions to obtain accurate measurements Sit quietly and relax while taking measurements Do not lean forward Do not let your rolled Do not take with your body at an up sleeve be inside the measurements at the angle during measuring section elbow Place your elbow measurements Roll your sleeve far up in the elbow rest Take measurements in your arm the proper aX Place the main unit in front of you on a table at heart height Ere 16 BEL date a Reading continued Do not take measurements e Within 1 hour of eating or drinking alcohol e Immediately after drinking coffee or tea or smoking e In a moving vehicle e Immediately after exercising or taking a bath Wait at least 20 minutes and take a measurement while staying quiet e In cold places Take measurements at room temperatures around 20 C 68 F e When you need to urinate Wait several minutes after urinating before taking measurements Be sure to obey the following points for accurate measurements Do not move your body arm or fingertips Do not touch the main unit e Do not talk
19. ng and Calling up Blood Pressure Readings continued Calling up readings from memory Readings can be recalled after being saved without having to switch the unit on M R E After approx v9 seconds m A E n alm Pulse min i y After approx 2 seconds After approx 2 seconds 25 E 1 Press the user selection button on the wireless display to select the desired user To select User f To Step 2 To select User Press the user selection button Press the Memory Recall button e The average readings of all recorded measurements are displayed e When readings from 90 measurements have been saved the average of the readings from all 90 measurements will be displayed If there is only 1 measurement recorded mark Q amp A will not be displayed e The mark will be displayed Blood pressure indicator 4 will be lit up for approximately 6 seconds 3 Press the Memory Recall button to display readings starting with from the most recent measurement e Each time the Memory Recall button is pressed readings are displayed in order of the most recent measurement e The memory number measurement date and time are alternately displayed in approximately 2 seconds Press the Adjust button 2 on the wireless display to switch off the unit e If you forget to switch off the unit it will do so automatically after approx 30 seconds
20. od pressure measurement is 120 mmHg over 80 mmHg 120 80 for example your systolic pressure is 120 mmHg while your diastolic pressure is 80 mmHg 3 I Important Instructions Before Use Ez 1 Do not confuse self monitoring with self diagnosis Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history 2 If you are taking medication consult with your physician to determine the most appropriate time to measure your blood pressure NEVER change a prescribed medication without first consulting with your physician 3 Blood pressure can vary based on many factors including age gender weight and physical condition In general a person s blood pressure is lower during sleep and higher when he or she is active Blood pressure can change easily in response to physiological changes The setting in which a person s blood pressure is measured can also affect the results Having one s blood pressure measured by a healthcare professional in a hospital or clinic can cause nervousness and may result in a temporarily elevated reading Because blood pressure measurements taken in a clinical setting can vary considerably from those taken at home a person s blood pressure should be measured not only occasionally in the doctor s office but also on a regular basis at home Also if you find that your blood pressure is lower at home this is not unusual To accurately compare with you
21. periods shown above will be displayed e When the time has not been recorded or a single reading has been recorded will be displayed 3 Press the Adjust button 2 to switch off the unit If you forget to switch off the unit it will do so automatically after approx 30 seconds 27 Era 1 Tilt the main unit using the handle in the direction of the arrow until the unit is locked 2 Place the wireless display on top of the unit securely To transport the unit e Carry the main unit and the wireless display separately Since the wireless display cannot be secured in place be careful to avoid dropping the unit EXE 28 I Specifications Power source DC 6 V Main unit Four AA LR6 size alkaline batteries AC 120 V 60 Hz when using AC adapter DC 3 V Wireless display Two AA LR6 size alkaline batteries Display Digital LCD Method of measurement Oscillometric system Measurement range Blood pressure 0 mmHg to 280 mmHg Pulse rate 30 to 160 beats per minute Accuracy Blood pressure Within 3 mmHg Pulse rate Within 5 Operation temperature 10 C to 40 C 50 F to 104 F 15 to 90 humidity range RH Storage temperature 20 C to 60 C 4 F to 140 F humidity range 10 to 95 RH Measurable arm Approx 734 to 13 20 cm to 34 cm circumference Weight Main unit Approx 1550 g 54 7 oz not including batteries Wireless display Approx 160 g
22. proper position for taking a measurement Place the main unit on a table so that it is flat and the center of the unit is at heart height Differences in height will cause differences in blood pressure values If the heights of the chair and table are not suitable you may have to lean forward In this case form a stable stack of books or similar objects under the main unit to adjust the height of the main unit You cannot use the unit while lying down Use only in a sitting position 1 Put the main unit on a table in front of you and slide your arm through the measurement section of the unit Remove your shirt or roll up your sleeve so that the measuring section will be on your bare skin If rolling up your sleeve causes pressure on 2 your arm or underarm remove your shirt for measurements Be sure that the rolled up sleeve is not inside the cuff area when taking measurements 2 Place your elbow on the elbow rest with y your palm up and relax 15 E 3 Place the wireless display in front of your body where you can see it easily e The main unit and the wireless display transmit receive the measured values through infrared rays See page 18 e Do not put your hand or any other objects in front of the wireless display Differences in blood pressure values between the left and right arms may be around 10 mmHg The blood pressure can be measured in either the left or right arm but all measure
23. r physician s reading take your Panasonic blood pressure monitor to your doctor s office and compare readings in this setting 4 People suffering from cardiac arrhythmia vascular constriction liver disorders or diabetes people with cardiac pacemakers or a weak pulse and women who are pregnant should consult their physician before measuring their blood pressure themselves Different values may be obtained due to their condition 5 Try to take your blood pressure measurements at the same time and under the same conditions every day e The ideal time to measure your blood pressure to obtain your so called base blood pressure is in the morning just after waking up before having breakfast and before any major activity or exercise If this is not possible however try to take measurements at a specified time prior to breakfast and before you have become active You should relax for about 5 minutes before taking the measurement e The following situations may cause substantial variations in blood pressure readings and should therefore be avoided at least 4 30 minutes prior to taking your blood pressure Blood pressure will be higher than usual when you are excited or tense when you are taking a bath during exercising or soon after exercising when it is cold within one hour after eating after drinking coffee tea or other beverages containing caffeine after smoking tobacco when your bladder is full
24. ramatically shortened Use alkaline batteries Panasonic Oxyride batteries can also be used 9 Parts Identification Main unit o oo N gt View from Top 1 Measuring section Pressure cuff Battery cover for main unit Battery cover for main unit Bottom of main unit IR transmitter on both sides Connector 5 Arm support The angle of this product can be adjusted so that measurements can be taken without having to be ina forced posture Elbow rest Quick air release button Handle On Off and Start button AC Adapter EW31555 included Ere 10 Parts Identification continued Wireless display View from Bottom A Display Ei Set button El Adjust button Display off H AM PM comparison button Specifications of the product or parts may be changed without prior notice When Using the Main Unit with the AC Adapter E IR receiver Be sure to use only the exclusive AC adapter included Do not use the power cord with any product other than this AC adaptor EW31555 Use of other AC adapters could cause damage to the unit or physical harm to the user AC 120V 1 Connect the power cord to the AC adaptor 2 Insert the AC adapter plug into the connector on either side of the
25. rogress e Doing so may cause incorrect readings If the unit becomes dirty clean it with a soft cloth moistened with warm water or soapy water Do not use alcohol benzine or paint thinner e Use of such chemicals may result in cracking or discoloration When the unit will not be used for a long time 30 days or more be sure to remove the batteries e Otherwise the batteries may leak and damage the unit The pressure cuff cannot be washed For storage avoid high temperatures high humidity and direct sunlight e Shortage under such conditions may result in damage Ere 32 FI Troubleshooting Display Status before error The indication disappears in the middle of the operation the or lt a mark is displayed Pressurization to more than 280 mmHg was performed The aX mark flashes for 2 minutes or longer Pressure decreased suddenly The heart mark y blinked only a few times or not at all Cuff does not inflate M I LL is displayed Lite is displayed Your arm or body moved mi Lt is displayed Failure of the main unit Cause and solution Batteries are exhausted See pages 11 13 Were measurements taken according to the proper procedure and in the correct posture See pages 15 18 Be sure your arm is properly inserted into the main unit See pages 15 18 Has the unit detected movement See page 20 Take it to the store where it was purchased for tes
26. rounding area due to generation of heat bursting or leakage Ere 12 BI Inserting the Batteries into the Wireless Display Always use alkaline batteries 2 AA size LR6 alkaline batteries e When replacing batteries always use 2 fresh alkaline batteries of the same type from the same manufacturer and replace them simultaneously 200 1 Turn the wireless display over and remove ii the battery cover by sliding it in the direction of the arrow while pressing lightly on the A mark 2 Check the polarities of the batteries and install them correctly 3 Replace the battery cover and slide it closed Replace batteries when The mark shown at left appears during use In this case press the On Off and the Start button on the main unit to interrupt the measurement If both batteries for the main unit and the wireless display must be replaced at the same time main unit and lt a wireless display are alternately displayed 13 EEE I Setting the time and date Ez Please be sure to set the date and time before taking the first measurement after purchasing the blood pressure monitor or after replacing the batteries If you attempt to take measurements without first setting the time and date then will be displayed Tr 2 v e a T t j gt I mA 3 i EPEN ns Sa ans 4 0 80 se i seod ane ae 5 30 5 6 7 Pre
27. s been completed see Flashing page 16 Movement has been detected that will significantly affect the reading Significant movement has been detected Movement has been detected repeatedly Significant arm movement has been detected etc Please take the measurement again a i 2 will appear on the display This function is designed to help you to take measurements accurately see page 33 Even if the Movement mark is not displayed we recommend that measurements be taken 2 times with 5 minutes between readings in order to obtain an accurate reading see pages 15 18 for correct position Ere 20 BEL date a ACECHA continued Irregular pulse function If the pulse rate varies by more than 25 from the average while a measurement is being taken when measurement is completed the CZV mark will be displayed The CAMA mark will be lit after approx 6 seconds of blinking when the measurement is completed If the C2 mark is lit please take the measurement again e In some cases if the pulse rate fluctuates greatly while a measurement is being taken it may be impossible to obtain an accurate reading Flashes Is lit SYS i iI EE A DIA 0 e If you save a reading where an irregular pulse was recorded the CZYTA mark will be displayed when you recall that reading If the NM mark is displayed an irregular pulse rate is detected not necessarily due to atrial fibrillation
28. s to Ensure Safe Reliable Operation L_ Do not drop the unit Protect it from sudden jars or shocks Do not insert foreign objects into any openings Do not attempt to disassemble the unit POs Ne If the unit has been stored at temperatures below 0 C 32 F leave it in a warm place for about 15 minutes before using it Otherwise the cuff may not inflate properly a Do not store the unit in direct sunlight high humidity or dust 6 When cleaning unplug the AC adapter from the AC outlet before cleaning Also do not plug in or unplug the AC adapter with wet hands Doing so may result in electric shock or fire 7 Do not spill water on the main unit wireless display or AC adapter Doing so may cause electric shock short circuiting or product damage 8 Do not use the AC adapter if it is damaged or if it plugs into the AC outlet loosely Doing so may result in electric shock or short circuiting 9 If the product does not operate properly or seems strange stop use and unplug the AC adapter immediately and request inspection and service Failure to do so could result in the risk of an accident electric shock or fire 10 When using the AC adapter make sure it is fully inserted into the AC outlet Failure to do so could result in electric shock or short circuiting 11 When the product is not in use unplug the AC adapter from the AC outlet Failure to do so could result in deterioration of the insulation due to dust or
29. ss the Set button 1 on the wireless display for at least 3 seconds Adjust the month Press the Adjust button 2 to adjust the number of the month Adjust the date 1 Press the Set button 1 and the number for the date will flash 2 Press the Adjust button 2 to adjust the number of the date Adjust the hour 1 Press the Set button 1 and the time will flash on and off 2 Press the Adjust button 2 to adjust the number of the hour Adjust the minutes 1 Press the Set button 1 and the number for minutes will flash 2 Press the Adjust button 2 to adjust the number of minutes Finally synchronizing with a time signal press the Set button 1 to complete the procedure e The date and time are alternately displayed in approximately 2 seconds Press the Adjust button 2 to turn off the unit During leap years 3 1 will be displayed when it is February 29th Please manually reset the date to 2 29 EXE 14 __ il Taking a Reading Advice In general blood pressure measurements are lower on the second attempt because you are calmer For people who easily get tense measuring twice each time is advised When two measurements are taken normally the smaller measurement is stored When taking two measurements always stay quiet for 4 to 5 minutes after the first measurement before taking the second measurement Getting into the
30. th electrical outlet of voltages marked on name plate For use in the U S A use AC adapter only with AC 120 V electrical outlet Use with electrical outlets at other voltages may results in the risk of fire electric shock or burns 22 Do not allow any material to drape over the AC adapter Doing so could result in the risk of fire 23 Do not modify or attempt to repair the product or AC adapter by yourself Doing so could result in the risk of fire electric shock or personal injury 7 Easily Check Your Blood Pressure Readings _ Against the JNC 7 Classification Blood Pressure Categories mmHg Stage 2 Hypertension e g SBP 165 g Up DBP 105 Stage 1 Hypertension e g SBP 150 3 ug g DBP 95 100 Prehypertension e g SBP 130 DBP 85 Normal e g SBP 115 DBP 75 Diastolic Blood Pressure DBP O oO 120 140 160 mmHg Systolic Blood Pressure SBP If the two blood pressure measurements systolic diastolic fall into separate categories your level is classified in the higher of the two categories For example a Stage 2 systolic reading but a diastolic pressure reading in the normal range JNC 7 The Seventh Report of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure National Institute of Health NIH Publication No 03 5233 May 2003 IMPORTANT Do not be alarmed by temporarily high or low readings because fluc
31. ting and repairs Symptom e The position of the main unit is higher or lower than your heart when measuring e Your arm was not inserted properly into the main unit e You moved or talked during measurements See pages 15 18 Systolic or diastolic blood pressure value is high or low Value is different from that measured by the doctor e Blood pressure varies in response to minute changes in your mental state such as your reaction to a doctor s presence e Sit quietly for 4 to 5 minutes and then take another measurement See pages 15 18 30 31 Measurement values are different with each measurement 33 E Symptom e Press the ring portion on the outside of the Pressure cuff comes off pressure cuff into the main unit See page 23 Indications on the e The wireless display is improperly wireless display do not positioned change during operation Your hand or another object is in front of the wireless display See page 18 No display appears even Batteries are installed with the polarities when the On Off and wrong See pages 11 13 Start button is pressed e Batteries are exhausted See pages 11 13 The CAVA mark e There was a significant fluctuation in pulse flashes when readings when readings were being taken are being taken See page 21 The SS mark flashes when readings are being taken e Your arm or body moved See page 20 e In some cases this will be displayed
32. tuations in a person s blood pressure are not uncommon If possible measure and record your blood pressure at the same time every day and consult your physician if you have questions or concerns If abnormal variations in blood pressure are observed in measurement please consult your physician 8 i Preparations Prior to Taking Measurements To use this product the power supplies are required for both the main unit and the wireless display Main unit Wireless display Power supply Power supply Exclusive AC adapter EW31555 2 AA size LR6 batteries included or Approximately 2000 4 AA size Panasonic LR6 batteries Measurements can be taken Approximately 150 measurements can be taken Depending on the conditions battery life may be dramatically shorter Use of the main unit with the dedicated AC adapter EW31555 included is recommended Main unit and wireless display are not sold separately and cannot be purchased as replacement parts For Batteries e Unit with batteries can be used up to 6 times a day when using Panasonic Alkaline batteries AA sized LR6 batteries under the following conditions Room temperature 73 F 23 C Pressurized to 170 mmHg Circumference of the arm 11 51 64 30 cm e If batteries other than alkaline batteries are used or batteries are used in a room colder than 73 F 23 C and when measuring a person with thin arms or high blood pressure battery life may be d