Home
Chief FHSVB flat panel ceiling mount
Contents
1. VESA 100 x 100 VESA 75 x75 Figure 3 If the display does not have a 75 x75 or 100 x 100 VESA mounting pattern an interface bracket will be required The FHSV Series mount comes with a 200 x 100 interface bracket FSA4101 Kit If the display being installed does not have any of the three mounting patterns identified above contact a Chief Customer Service representative by calling 952 894 6280 or by visiting www chiefmfg com WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT DO NOT install display without an approved interface bracket and hardware 2 Install FSA4101 interface bracket if required following the instructions provided with the kit 3 Install two Phillips pan head machine screws C D or E into upper mounting holes in display back leaving 3 16 of screw protruding out of display 4 Align screws in display back with upper mounting holes in Centris cup and lower display until screws are seated in lower area of mounting slots 100 x 100 or teardrop mounting holes 75 x 75 5 Hold display so that display back is against Centris cup and install two Phillips pan head machine screws C D or E through lower mounting holes in Centris cup and into lower mounting holes in display back NOTE If the display has a recessed mounting surface spacers F or G must be placed between display back and Centris cup and longer screws mus
2. Chiave esagonale E Zeskantsleutel Cl t te hexagonale KnIOY c WecTurpaHHon ronoBKo TOOLS REQUIRED FOR INSTALLATION AND PARTS 3 16 provided 5 32 provided H 1 3 16 J 1 5 32 e B 2 VD 4 5 16 18 x 3 8 M4 x 20mm e e C 4 FE 4 M4 x 12mm M4 x 30mm FSA4101 FHSV only F 4 1 2 x 3 8 FFC 4 1 2 x 3 4 I M FHS110 FHSV Installation Instructions INSTALLATION Mount Installation IMPORTANT The following installation instructions assume that a 1 1 2 NPT pipe has been properly installed and is in place 1 Thread mount A onto 1 1 2 NPT pipe until hand tight 2 Adjust mount A position until Centris cup is facing the desired position of the display See Figure 1 1 1 2 NPT Pipe Centris Cup Figure 1 3 Whenmount A is properly positioned secure mount A to 1 1 2 NPT pipe by installing and tightening 5 16 18 x 3 8 set screw using 3 16 hex wrench H See Figure 2 NOTE If mount is being used to couple two pipes use both set screws when securing mount A to pipes Figure 2 Display Installation 1 Determine mounting pattern on display See Figure 3 NOTE The mount is designed to accommodate both 75 x 75 and 100 x 100 VESA mounting patterns If the display being mounted has either of these mounting patterns continue with display installation
3. A TA A Z 5 3 le S S Consumer da
4. INSTRUCTIONS INSTALLATION Direct Attach Ceiling Mount FHS110 FHSV G CHIEF FHS110 FHSV Installation Instructions DISCLAIMER CSAV Inc and its affiliated corporations and subsidiaries collectively CSAV intend to make this manual accurate and complete However CSAV makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind CSAV makes no representation of warranty expressed or implied regarding the information contained herein CSAV assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instruction
5. s provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity of the mount can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of the mount and all attached components does not exceed 40lbs 18 14kg Installation Instructions FHS110 FHSV LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations COXMUTE 3acTexky Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme OTBepTka Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Ocnabbre 3acrexky Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a sextavada
6. t be used to secure display Installation Instructions FHS110 FHSV C D orE x4 u A x 1 Figure 4 gt 1 1 2 NPT Pipe Display C D or E x 4 A x 1 Figure 5 6 Route cables and wires to display ADJUSTMENTS To adjust display Roll Pitch and YAW tension 1 2 3 4 5 Disconnect all wires and cable from the display Remove two Lower screws securing display to Centris cup Loosen two Upper screws securing display Lift display upward and away from mount Using a Phillips screwdriver turn the tension adjustment screw clockwise to increase tension or counter clockwise to decrease tension See Figure 6 Re install display Figure 6 FHS110 FHSV Installation Instructions Installation Instructions FHS110 FHSV FHS110 FHSV Installation Instructions o USA International A 8401 Eagle Creek Parkway Savage MN 55378 Le CH E F P 800 582 6480 952 894 6280 NN F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 30l Block D Lily YinDu International Building 8805 000219 LuoGang BuJi Town Shenzhen CHINA Post Code 518112 2007 Chief Manufacturing WAH AP AS Ei Ee ERR ES ER A EB DR 301 www chiefmfg com P 86 755 8996 9226 8996 9236 8996 9220 01 07 F 86 755 8996 9217
Download Pdf Manuals
Related Search
Related Contents
Jackson TS-66 User's Manual Hunter 59160 Installation Guide Betriebsanleitung (Original) User Instructions Pulse Input Adapters (S-UCA/B-M006) User's Guide R&S®OSP Open Switch and Control Unit Quick that_bulletin13_2013 « Éducation & pédagogie » : au cœur de notre métier Copyright © All rights reserved.