Home
        JDSU TP250 cable network tester
         Contents
1.    Net Rite    Continuity and Wiremap Tester    Trace Rite    Tone Generator and Amplified  Tone Tracer    User s Guide    www  jdsu com know             Voltage Probe    Tracer Power  Button    Volume  Up Down                     Indicator  LED       Power Tone  Type Switch    RJ11    LCD    6 RJ11             Q                               Warning     Do not attach to AC power  this may  damage the Net Rite    and the Trace Rite     generator and could cause a safety hazard  for the user    Caution    Improperly crimped  damaged or un crimped  plugs can damage the jack on the Net   Rite    and Trace Rite     Inspect plugs   for proper termination and crimping before  inserting into the tester  Contacts should  always be recessed into the plastic grooves  of the plug     Features    Net Rite    Features    Auto on when sensing the remote or a  short    Auto off when the remote is  disconnected to conserve battery life    Ergonomic shape  with soft edges    When not in use  the remote stores in  the bottom of the main unit    Trace Rite    Features    Self powered Amplified Probe on the  Tone Tracer turns on when tone sensor  button is depressed and off when the  button is released    Compact Tone Generator turns off  automatically when stored in the bottom  of the Tone Tracer to conserve battery  life   Ergonomic shape with soft edges    Two selectable tone styles with LED  indicator    Changeable Round Tip Probe  Adjustable Volume control    Instructions for Use    To Wire
2. JDSU guarantees that its products will   be free of all defects in material and  workmanship  This warranty extends for the  period of 12 months for test instruments  and 3 months for cables from date of  manufacture or purchase  proof of purchase  required     All product deemed defective under this  warranty will be repaired or replaced at  JDSU   s discretion  No further warranties  either implied or expressed will apply  nor  will responsibility for operation of this device  be assumed by JDSU        WEEE Directive Compliance    JDSU has established processes in  compliance with the Waste Electrical and  Electronic Equipment  WEEE  Directive   2 002  96 EC  This product should not be  disposed of as unsorted municipal waste  and should be collected separately and  disposed of according to your national  regulations  In the European Union  all  equipment purchased from JDSU after  005  08  13 can be returned for disposal  at the end of its useful life  JDSU will  ensure that all waste equipment returned    17    is reused  recycled  or disposed of in       environmentally friendly manner  and in  compliance with all applicable national   and international waste legislation  It is   the responsibility of the equipment owner  to return the equipment to JDSU for  appropriate disposal  If the equipment   was imported by a reseller whose name   or logo is marked on the equipment  then  the owner should return the equipment  directly to the reseller  Instructions for  returning 
3. lded Cable                   1 2 Short            Split    5  12345678   27456 18    3 4  amp  4 5 Split Pair          Miswire    12345678          2  amp  3 Miswired  7             Battery Installation    Net Rite     1  Using a  1 Phillips screwdriver  unscrew  and remove the battery door     2 Remove old cell batteries  Rapping the  case against the palm of the hand will  help dislodge the batteries    3  Install 4 new LR44 cell batteries  orienting  the plus end of battery with the plus  symbol on case     4  Replace battery door and reinsert the  screw  Do not over tighten                 Trace Rite       1 Remove the screw at the back of the Tone  Generator or Amplified Probe with a  1  Philips screwdriver and remove battery  door     2 Remove old coin batteries  Rapping the  case against the palm of the hand will  help dislodge batteries    3  Install 4 new LR44 cell batteries being  careful to orient plus end of battery with  plus symbol on case     4  Replace battery door and reinsert the  screw  Do not over tighten        To Replace the Probe           1 Using a  1 Phillips screwdriver  remove  the screw on the back of the Trace Rite     nearest to the probe     2 Pull the tip out of the top   3 Push the new tip into the top     4  Replace the screw and tighten  being  careful not to over tighten        10    Models  options  amp  accessories    number    Net Rite continuity and   wiremap tester and Trace Rite KP260  tone generator with onboard   probe kit    Net Ri
4. map a Cable    1  Using the RJ45 jacks  connect Net Rite     main unit and remote to the cable you  want to test     2 An icon and the wiremap are always  displayed  Net Rite    reports   a  PASS when the cable pins are  properly connected per T568A B  and there are no other faults  or    b  an error icon when it does not  pass  Pins with errors flash an error  message  Miswire  Split  Open  Short   or Reverse     To Trace a Tone    1 Using the RJ12 jack on the remote   connect the Trace Rite    Tone Generator  to the cable to be traced     2 Slide the Tone Generator switch up to  select one of the two tones  stutter tone  or fast stutter tone   The green LED lights  and flashes intermittently to indicate the  tone generator is powered on and which  tone speed has been selected     3 Press and hold the black button on the  Amplified Probe to turn on the probe     3    4  Adjust volume control on the side of the  Trace Rite    to a comfortable level  If the  signal is very loud when near the cable   adjust the volume to avoid overloading the  Trace Rite     When overloaded  small  increases or decreases in the signal at the  tip cannot be heard     5  Hold the tip of the Trace Rite    near the  cable to be identified  The signal will be  loudest on the wire or cable attached to  the generator  Separating the wires or  cables may help in isolating the correct  cable     Interpreting Wiremap Errors    Miswire   One or more pins or pairs are not  connected to the correct pins at 
5. nt will  also receive applicable product updates  and will be thoroughly tested  ensuring  peak performance of the complete  feature set     Equipment Return Instructions Please  contact your regional Technical Assistance  Center to get a Return or Reference  Authorization to accompany your equipment   For each piece of equipment returned for  repair  attach a tag that includes the following  information      Owner   s name  address  and  telephone number              serial number  if applicable    product type  and model        Warranty status   If you are unsure  of the warranty status of your  instrument  contact Technical  Assistance      15    e Adetailed description of the  problem or service requested                name and telephone number  of the person to contact regarding  questions about the repair     e        return authorization  RA   number  US customers   or  reference number  European  Customers      If possible  return the equipment using the  original shipping container and material    If the original container is not available   the unit should be carefully packed so   that it will not be damaged in transit  when  needed  appropriate packing materials can  be obtained by contacting JDSU Technical  Assistance  JDSU is not liable for any  damage that may occur during shipping  The  customer should clearly mark the JDSU   issued RA or reference number on the  outside of the package and ship it prepaid  and insured to JDSU     16    Warranty Information    
6. te continuity and TP250  wiremap tester  Trace Rite tone generator with 11250  on board probe       11    Net Rite    Specifications    Physical Dimensions  Size  11 3 x 5 x 2 7 cm   4 5 x 2 x 1 1 inches   Weight  100 grams  3 5 02    with battery and  remote    Environmental  Operating temperature  0 to 50  C  32 to 122     Storage temperature   10 to 60  C  14 to 140  F  Humidity  10  to 90   non condensing    Power Requirements  Four  4  LR44 button cells  6 volts     Battery Life  6V alkaline battery  typical  times are  for the full capacity of the battery  Used continuously in one of the following modes  Standby  2 5 years  Cable Testing  150 hours    Externally applied voltage without damage   250 volts peak DC or  175 volts RMS AC for 5 seconds   100Vdc      70Vac RMS continuous    Cable Types  Shielded or unshielded CAT6  CATS               CAT4  and CAT3  Minimum cable length for testing for split pairs   1 meter  3 feet     12    Trace Rite    Specifications    Physical Dimensions  Size  20 6 x 4 45 x 3 0 cm   8 1 x 1 75 x 1 2 inches   Weight  113 grams  4 ounces   Environmental  Operating temperature  0 to 50  C  32 to 122  F   Storage temperature   20 to 60        4 to 140   F   Humidity  10  to 90   non condensing    Power Requirements  Four  4  LR44 button cells  6 volts     Battery Life  6V Alkaline battery  typical  times are  for full capacity of the battery    Used continuously   Tone Generator  50 hours  Tone Tracer  10 hours    Externally applied voltage 
7. the other  end of the cable  i e   one to one   pin 1 to  pin 1  pin 2 to pin 2  etc     Split   A split pair is an error in the twisting  of the wires together within the cable  The  cables generally are made up of eight wires  twisted together in 4 pairs  These 4 pairs are  designated as pairs by the wiring standards  and are intended to carry a signal and its  return  1 amp 2 3 amp 6 4  amp 5 and 7 4 8 are the  pairs designated by T568A B for a RJ45 jack  or plug  A cable        be wired with correct  continuity  but not with correct pairing  This  often happens when the cable is terminated  consistently at both ends  but in the wrong  order  A dynamic or AC test is required to  detect this type of error  If the only error   is a split pair error  the cable has correct  continuity  If cross talk is not a concern  as in  flat satin cable  the cable is good if the only  error is the split pair error     Open   tThe pair is not connected     Short   The pair has a low resistance  connection between wire pairs or the shield   The wire pairs involved displays on the LCD  screen     Reverse   A reverse  Rev  pair is a special  case of a Miswire  and both icons will be  flashing  The wires are connected to the  correct pair of pins  but the two leads are  reversed     Voltage   When voltage is detected on  any of the pins  lightning bolt icons flash   Disconnect from the cable as soon as  possible     GREY FLASHING                  5    5  12345678  fed               Passing Shie
8. waste equipment to JDSU can   be found in the Environmental section of  JDSU   s web site at www jdsu com  If you  have questions concerning disposal of your  equipment  contact JDSU   s WEEE Program  Management team at WEEE EMEA jdsu   com     18       www jdsu com know    Document Information  Doc    TU9891   Revision 500  04 08  English          
9. without damage  250V DC or 175V RMS AC    Tone Frequencies      5     970Hz and 825Hz alternating tones    Tone Voltage   12 volts peak to peak no load  new battery    Tone Power   8 9 dbm into 600 ohms  new battery    13    Customer Services    This section provides a description of  customer services available through JDSU   including returns policies and procedures   and warranty information     Customer Service  Standard Services   Customer Service accompanies the sale  of every JDSU product  Customer Service  services include         Technical Assistance  Business Hour         Instrument Repair  Under Warranty  Repair  Calibration Services  and  Upgrade Services         Immediate Return Authorizations    Technical Assistance Expert business  hour technical support is included with your  product     Instrument Repair Our service centers  provide repair  calibration  and upgrade  services for JDSU equipment  JDSU  understands the impact of equipment down  time on operations and is staffed to ensure a  quick turnaround  Available services include  the following     Product Repair     All equipment   returned for service is tested to the   same rigorous standards as newly  14    manufactured equipment  This  ensures products meet all published  specifications  including any applicable  product updates     Calibration     JDSU   s calibration  methods are ISO approved and based  on national standards     Factory Upgrades     Any unit returned  for a hardware feature enhanceme
    