1. 4 JDSU Warning Do not attach to energized cables The LanRoamerPRO may be damaged Caution Improperly crimped damaged or un crimped plugs can damage the jacks on the LanRoamerPRO Inspect plugs for proper termination and crimping before inserting into the tester Contacts should always be recessed into the plastic grooves of the plug Do not use with 6 position plugs RJ11 without an adapter Features Auto on and auto off when testing cables just plug both ends into tester Two line by 16 character full alphanumeric LCD with icons for clear results Cable test results displayed in wire map format with a message line for shorts and split pairs Tests for shorts opens miswires reversals and split pairs with remote connected Pre test One ended testing for shorts opens and split pairs no remote Displays PASS icon and sounds beeper optional for T568A B passing cables Length measurement in feet or meters using cable capacitance method Tone generator mode for use with tone tracers Auto off in any mode and low power consumption for long battery life Snap together case for easy storage of a remote and convenient patch cable testing Description The LanRoamerPRO has an LCD display and four momentary buttons One remote attaches to the main unit for storage or patch cable testing The rubber end cap at the bottom is the battery compartment cover The LanRoamerPRO st
2. RJ45 jack or plug A cable can be wired with correct continuity but not with correct pairing This most often happens when the cable is terminated consistently at both ends but in the wrong order A dynamic or AC test is required to detect this type of error If the only error is a split pair error the cable has correct continuity If cross talk is not a concern as in flat satin cable the cable is good if the only error is the split pair error In TEST mode the pin numbers on the second line of the wire map with split pairs flash and an error message is displayed listing the pin numbers of the pairs involved in the error In the PRE TEST mode the error message is displayed 13 Examples of oe Errors nen DARK ON LIGHT FLASHING 1 1 2 x42 Open EN anda 7 4 4 5 P 123456788 ID 6 6 3496725 1 7 le AT 8 8 1 ZB 2 2 Short 3 x3 4 4 FAIL 5 5 6 6 7 A 7 8 gt XX 8 Th 2 Miswire 3 4 gla 123456788 ID ade F 6 l12z456rT8 1 7 8 oensounzon SE SENSE 1 not twisted with 2 3 not twisted with T568A B en Cable ae 1 ooo Cc Oo as PASS 123456788 ID 12545678 1 14 Battery Replacement When the battery low icon is on the battery should be replaced as soon as practical The cable testing results will become unreliable w
3. converts the currently set length constant to the new units on exit of setup The up and down arrow buttons scroll through the set able options The SEL button changes the current setting to the other option On exit the mode screen first offers to return to the last mode used before entering setup The LanRoamerPRO monitors for voltage being present on the RJ jack when off in TEST PRE TEST mode or in LENGTH mode The VOLTAGE message appears on the screen and the beeper sounds continuously until the voltage is removed Adjusting Length Constant Cable Has Faults Cable Passed T568A B PASS FAIL CAL 2m TEST Progress Beeper Off ID Number Icon Main Unit Pin Numbers Alphanumeric Remote ID Characters Displayed Below It Cable Shield Indicator LanRoamerPRO LCD Display Instructions for Use LanRoamerPRO powers off automatically after 5 minutes of continuously testing a cable when auto on powered up the tester Disconnecting the cable restores normal function Most power on modes will timeout in about 18 minutes except for tone which is about 2 4 hours Be sure to install a battery if using for the first time see battery installation Cable Testing To Test a Patch Cable see Caution on page 1 about cables with bad plugs 1 Plug one end of patch cable into main unit 2 Plug other end of cable into remote unit 3 The tester will power on immediately and will indicate a te
4. severity has to do with the ability of a more severe error to mask lower severity errors For example if there is a short in the cable miswires and split pairs may not be detected for the pairs involved in the short fault Short The pair has a low resistance connection from one wire of the pair to the other wire of the pair or to any other wire in the cable or the shield A short in the TEST mode is indicated by the FAIL icon being on and flashing X s in the appropriate pin position of the second line of pin numbers plus one or more error message lines listing all the pins shorted together In the PRE TEST mode the error messages are displayed 12 Miswire A wire or both wires of a pair are not connected to the correct pins at the other end of the cable In TEST mode the wire map shows the pin numbers from line 1 main to line 2 remote A reverse pair is a special case of a miswire in which the pair is wired to the correct pair of pins or to another designated pair of pins but the two leads are reversed In PRE TEST this type of error is not detectable Split Pair A split pair is an error in the twisting of the wires together within the cable The cables generally are made up of 8 wires twisted together in 4 pairs These 4 pairs are designated as pairs by the wiring standards and are intended to carry a signal and its return 1 amp 2 3 amp 6 48 5and 7 amp 8 are the pairs designated by T568A B for a
5. al and workmanship This warranty extends for the period of 12 months for test instruments and 3 months for cables from date of manufacture or purchase proof of purchase required All product deemed defective under this warranty will be repaired or replaced at JDSU s discretion No further warranties either implied or expressed will apply nor will responsibility for operation of this device be assumed by JDSU A WEEE Directive Compliance JDSU has established processes in compliance with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC This product should not be disposed of as unsorted municipal waste and should be collected separately and disposed of according to your national regulations In the European Union all equipment purchased from JDSU after 2005 08 13 can be returned for disposal at the end of its useful life JDSU will ensure that all waste equipment returned is reused recycled or disposed of in an environmentally friendly manner and in compliance with all applicable national and international waste legislation It is the responsibility of the equipment owner to return the equipment to JDSU for appropriate 17 disposal If the equipment was imported by a reseller whose name or logo is marked on the equipment then the owner should return the equipment directly to the reseller Instructions for returning waste equipment to JDSU can be found in the Environmental section of JDSU s web site a
6. arts in an off condition when cable testing with a remote This yields maximum battery life and takes advantage of the fact that the auto on feature effectively synchronizes the test cycle to the cable being connected for results in 2 seconds The tester powers on and testing begins automatically when a connection from the main unit to the remote is sensed The tester will automatically power off within 5 seconds of the cable being disconnected Upon completion of the test the wire map display ID and any faults are displayed The top line of numbers on the display represents the connector pins on the main unit The second line of pin numbers is the connector pin numbers of the remote normally being the same as the top line for a normal data cable If there is a miswire the numbers on the second line will indicate the pin numbers detected If no connection was detected for some of the pins the second line will be blank in those pin locations If a short is detected the second line will have a flashing x in that position and the specific short condition displayed on the 2 third line If a split pair is detected those pin positions on the second line will be flashing the pin numbers detected from the remote and the specific split condition displayed on the third line If there are multiple errors to display on the third line the messages are displayed in sequence until all are displayed The ID icon will have a number directl
7. constant The SEL button changes the pair being measured in a 1 2 3 6 4 5 7 8 and auto select sequence The pair number is displayed next to the length except in auto select mode If a selected pair has a fault the fault replaces the length reading on the LCD In auto select mode the tester automatically selects a pair without a fault The length constant is changed with the up and down arrows The CAL icon is on while adjusting the constant If network terminator patterns are found in length mode the tester will display T Ring Network xbase T Network or Network all four lines terminated Tone The tone mode generates audio tones for use with tone tracers on all pairs a selected pair or a selected pin The signal generated on a pair has the signal on one pin and the complement of the signal on the other pin of the pair yielding a nominal 10 volts peak to peak across the pair The SEL button selects 4 one of the four tone sounds provided The up and down arrows scroll through the pairs and pins that have signal on them All pins not being driven are held at tester ground Setup The setup mode is provided to set user selectable options The beep on pass can be turned on or off default is on The pass criteria can be set for shielded or unshielded cables default is unshielded The length and length constant can be set for meters or feet default is feet If the length units are changed the tester
8. hen the battery reaches about 4 5 volts To Replace Battery 1 Remove rubber battery cap by pressing on bottom edge of the cap with the heel of the hand until the cap pops off 2 Pull battery out of cavity and remove battery snap 3 Connect a new Alkaline 9 volt battery to battery snaps 4 Slide battery into cavity and snap cap in place When installing a new battery disconnect any cables connected to the tester The length and pre test modes will be improperly calibrated if a cable is present 15 Specifications Physical Dimensions Size 14 5 cm x 7 2 cm x 3 cm 5 7 x 2 85 x 1 2 Weight 176 grams 6 2 oz with battery and remote Environmental Operating temperature 0 to 50 C 32 to 122 F Storage temperature 10 to 60 C 14 to 140 F Humidity 10 to 90 non condensing Battery Life 9V Alkaline battery typical times are for the full capacity of the battery used continuously in one of the following modes Standby 2 5 years Cable Testing 120 hours Cable Types Shielded or unshielded CAT3 CAT4 CAT5 CAT5E CAT6 and Coaxial Cable Minimum cable length for testing for split pairs 1 meter 3 feet Minimum cable length for PRE TEST 1 25 meter 4 feet Length measurement range CAT5 6 0 to 762 meters 0 to 2500 feet Coax Cable 100 ohms maximum DC resistance center conductor plus shield 16 Warranty JDSU guarantees that its products will be free of all defects in materi
9. her end to the wall jack 3 Attach one end of the second supplied one foot patch cable to the main unit and other end to the patch panel jack 4 The tester will power on immediately and indicate a test in progress by displaying the TEST icon It will be followed within 2 seconds by a wire map display of the results plus a PASS icon and a beep if it passed the set shield criteria and T568A B standard The ID number for the remote will also be displayed 5 Disconnect cable after test The test repeats every 5 seconds Application Hints The jumper cables must be short compared to the cable run for accurate split pair indication no more than 10 of the total run length To Test Coax tester off or in TEST PRE TEST mode 1 Plug RJ45 to F coax adapters into the remote and main units 2 Attach cable to be tested to F connectors 3 The tester will power on if it senses the cable If not the cable is open The coax adapter is connected to the 1 2 pair and will display 12 on the second line if good and flashing xx if shorted 4 Length may be measured as well by setting length constant and selecting 1 2 pair To Place Tone on a Cable 1 Turn on unit by pressing any button If not in tone mode press MODE until TONE is displayed than press SEL button 2 Press SEL until desired tone is selected The up down arrow keys select the pin or pair s to carry the tone 3 Connect cable to be traced to
10. main unit For best signal do not connect remote Due to the shielding effect of twisted pairs the strongest signal is obtained by having one wire of a pair carry tone Selecting a single pin instead of a pair will do this 10 4 To turn tone off press the MODE button until TURN OFF is displayed then the SEL button The tone will turn off automatically after about 2 4 hours To Measure Length 1 Connect cable to main unit A remote may be at the other end 2 Turn on unit by pressing any button If not in length mode press MODE until LENGTH is displayed than press SEL button To change length between feet and meters use setup mode 3 Press up and down arrows to adjust length constant If length constant is unknown for a particular cable a known length of cable may be used to set the constant Fifty feet or more is suggested to minimize the resolution error 1 foot in 50 is 2 uncertainty Connect known cable to tester and set cable constant using up and down arrows until the length reads correctly Interpreting Cable Test Results The PASS icon will be on if the cable has all pins properly connected per T568A B The FAIL icon will be on if there is a short or split pair Neither icon will be on if there are opens or miswires The wiremap should be inspected for these types of errors Definition of Errors See failure example drawings The three classes of faults discussed below are in order of severity The
11. st in progress by displaying the TEST icon It will be followed by map results plus a PASS icon and a beep if it passed both the T568A B standard and the configured shield criteria 4 Disconnect patch cable after test The test repeats every 5 seconds To Test Cable from One End This can be done immediately after termination of one end of the cable because no connector or remote is required at the other end of the cable Attach a remote after the pre test and you are ready for a full test when the other end is terminated 1 Attach one end of supplied one foot jumper to main unit and the other end to the wall plate or patch panel jack 2 Turn on unit by pressing any button If not in pre test mode press MODE until TEST PRE TEST is displayed than press SEL button 3 Results should appear within 5 seconds Pressing SEL button starts a new test immediately 4 Disconnect cable after test The test repeats every 5 seconds Application Hints The jumper cables must be short compared to the cable run for accurate open and split pair indication either no more than 10 of the total run length or 3 feet whichever is less Cable being tested must be at least 4 feet long for pre test to work properly To Test Installed Cable office jack to patch panel with remote 1 Remove remote unit from main unit by sliding remote towards top of the main unit 2 Attach one end of supplied one foot patch cable to the remote and ot
12. t www jdsu com If you have questions concerning disposal of your equipment contact JDSU s WEEE Program Management team at WEEE EMEA jdsu com 18 Shipping Before returning any product to JDSU you must first request a Return Merchandise Authorization Number by contacting our Customer Service Dept at 805 383 1500 1 No shipments will be accepted without this number which must be clearly marked on the shipping label 2 Ship the equipment with a copy of the sales receipt if available 3 Attach a description of the operational problem 4 Include a contact name phone number and E mail address 5 Pack securely to prevent damage during shipping 6 Ship prepaid to JDSU 808 Calle Plano Camarillo CA 93012 Support Service For technical information and support please visit www jdsu com hbn 19 Contact Information 808 Calle Plano Camarillo CA 93012 USA Regional Sales North America Tel 1 805 383 1500 Fax 1 805 383 1595 Latin America Tel 55 11 5503 3800 Fax 55 11 5505 1598 Asia Pacific Tel 852 2892 0990 Fax 852 2892 0770 EMEA Tel 49 7121 86 2222 Fax 49 7121 86 1222 Customer Service www jdsu com customerservice O JDSU TU9845 Rev B 04 07
13. y below it indicating the remote ID number The LanRoamerPRO is powered on by pressing any of the four buttons The tester will turn on in the last mode used before turning off There are four modes of operation as described below In any mode pressing the MODE button causes the mode select screen to be displayed The TURN OFF message is usually the first one displayed Subsequent presses of the MODE button cycle through the other modes Pressing the SEL button causes the currently displayed mode to be entered Test Pre test If a remote is sensed the tester reverts to the power off cable test described above Test If there is no remote the LanRoamerPRO uses the length and cable test capability to attempt to measure a cable for shorts opens and split pairs Pre test TEST and the current pair under test icons being on indicate a test in progress The results are displayed as messages on the LCD Because a test can take up to about 5 seconds to complete the SEL button which immediately 3 starts a new test should be pressed whenever a new cable is connected for pre test Partial and erroneous results will be displayed until a complete test cycle has been run on a cable Length The length mode measures the length of a cable by measuring its capacitance and using the capacitance per unit length length constant to calculate the length The length is displayed on the LCD along with the current value of the length
Download Pdf Manuals
Related Search
Related Contents
帝京大学医学部附属溝口病院 治験に係わる業務手順書 Maytag MAH-3 Washer User Manual PDFダウンロード(10.2MB) 1 Wählen Sie RIDGID 700 User's Manual Hitachi CP-S840W/E User's Manual Antena DVB-T de alta ganancia y poco ruido para uso interior/exterior. [春野図書館]基準表(PDF形式:90KB) Dell PowerEdge M605 Owner's Manual Samsung GE82V-BBHL/XST คู่มือการใช้งาน Copyright © All rights reserved.