Home
Eaton Powerware 3105
Contents
1. 1023921 User s manual RevisionA 350 700 VA 9 LED amp Alarm Status Table Green LED sues Bekrbyum 8r i A B run m iid AC Over Bat Bat Fault 0 0 0 Notes Blink 1 ON 0 5 seconds OFF 0 5 seconds Blink 2 ON 0 25 seconds OFF 0 25 seconds B1 1 beep 5 seconds ON 0 25 seconds OFF 4 75 seconds B3 2 beeps 5 seconds ON 0 25 seconds OFF 0 25 seconds 2 times 4 seconds OFF B4 ON 0 5 seconds OFF 0 5 seconds B5 3 beeps 5 seconds ON 0 25 seconds OFF 0 25 seconds 3 times 3 5 seconds OFF Specification Model numbers Capacity 3105 350i 350 VA 210W 3105 500i 500 VA 300 W 3105 700i 700 VA 420 W Input voltage range 184 to 256 V 3 Vac 50 60 Hz auto sensing 350 VA 12 V 45 Ah Battery specification 500 VA 12V 5 Ah 700 VA 12 V 7Ah Typical backup time 3 min minimum at full rated load Internet phone fax protection RJ11 Due to continuing product improvement programs specifications subject to change without notice Short circuit protection Circuit breaker User s manual 1023921 10 350 700 VA Revision A Troubleshooting Symptom Possible Cause The battery is disconnected Connect the battery see Connect Battery and utility power is not and ensure power is available at the wall available at the wall outlet outlet UPS will not t i m Reduce the amount of equipment plugged into the outlets of the UPS Next resetthe circuit breaker by
2. C13 output receptacles that provide surge and spike protection 6 RJ11 data Phone Fax Protection Connectors 7 USB Communication Port The provided LanSafe monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage Your personal computer can receive the status as utility power line utility power failure on battery and low battery by contact closure signals that are sent through the USB port 8 Circuit Breaker resetable The button protrudes out when an overload condition occurs If the button protrudes out then disconnect some non essential equipment and reset the circuit breaker by pushing the button inward 9 Power connector IEC C13 connector Use you computer power cable to power the UPS Battery replacement procedure 1 Disconnect UPS system from power source Open battery door Disconnect used battery Connect new battery It is important that connectors be firmly attached to new batteries Close battery door 5 Properly recycle used battery User s manual 1023921 8 350 700 VA Revision A 350VA and 500VA models 12V 4 5Ah or 5Ah battery Status Indicators The UPS provides both visual and audible status indicators Visual indicators consist of three LEDs to represent the following conditions Onutility power operation On battery power operation UPS fault alarm
3. a qualified technician Failure to do so could result in an electrical shock Although the unit may be unplugged from utility power hazardous voltage still may be present through the battery 1 Place the Powerware 3105 UPS indoors in an area that has adequate airflow and is free of excessive dust Do NOT allow the UPS to be exposed to moisture rain excessive heat or direct sunlight 2 Use of the Powerware 3105 UPS product in life support applications where failure of this equipment can reasonably be expected to cause failure of life support equipment or to significantly affect its safety or effectiveness is NOT recommended 3 Shut off the UPS and disconnect the input power cord from the wall outlet before replacing the battery 4 When replacing the battery use the same number and type of battery 5 Do NOT dispose of battery in a fire The battery may explode 6 Do NOT open or mutilate the battery They contain an electrolyte that is toxic and harmful to the skin and eyes 7 Proper disposal of the battery is required Please refer to your local laws regulations regarding battery disposal 8 Use tools with insulated handles to replace the battery to avoid personal injury Due to energy hazard please remove wristwatches and jewelry such as rings when replacing battery 1023921 User s manual Revision A 350 700 VA 5 Battery connection required before use Connecting the Battery Principal shown below for deta
4. Powerware 3105 UPS User s manual 02005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced even extracts unless permission granted Every care has been taken to ensure the accuracy of the information contained in this manual but no liability can be accepted for any errors or omission The right to make design modifications is reserved Powerware 3105 UPS User s manual 1023921 Revision A Contents Introduction iiic oi eroi Aaeeea o rua andis cR cds ne dad sees ENSE tens RESI ER NEREA 4 FOAtUTOS MESE M 4 Unit TMS PO CHON ei m Requesting a Declaration of Conformity Safety InStr CEIODS 2 o orbe ener deve cusdehccesuscaveweedenseveedenssssenccecexsertecees 5 Battery connection required before use lLeeeeeeeeeeeeeeeeeeeee 6 Connecting the Battery nettes ppt ehe tese aa E ENa i Aiae 6 Installation and Operation lueeeeieeieeleeleeleeier eren nennen 6 Aypical applicati OBS 5 iier cerit eec E ie Pr eet tib sr ERR vno 7 IndiCators uiii eni eerte tei nuez 7 Battery replacement procedure 8 Status Indicators nir err ert ovi eee FEE aren yee 9 LED and Alarm Status Table riii dei err remeare cte ENEE ESERSE 10 Tere ifez don EE DEEP 10 Troubleshooting tort nter tent inert ern saree Er reU 11 Service and Sup
5. e help desk at one of the following telephone numbers and ask for a UPS technical representative United States 1 800 356 5737 Europe Middle East Africa Local Powerware representative Asia 852 2830 3030 Australia 61 3 9706 5022 Please have the following information ready Model number and Serial number Symptoms of failure or problem e Customer contact information For additional information please visit us online www powerware com 1023921 User s manual Revision A 350 700 VA 11
6. iled information how to connect please refer to battery replacement section Black Push the top right corner Pull out the battery onto a flat of battery cover forward stable surface and connect the black and remove the battery cover battery cable to the battery terminal Reinstall the battery into the UPS Reinstall the battery cover Installation and Operation Following steps explain how to connect and operate the Powerware 3105 UPS 1 Connect the UPS to a grounded power outlet Note It is recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS in service 2 Plug your computer monitor or load to be protected into the Battery Backup amp Surge Protection outlets These outlets will provide emergency battery backup power during power outages as well as protection from surges and spikes Do NOT plug LASER PRINTERS into the Battery Backup outlets Do NOT plug ACCESSORY SURGE strips into the Battery Backup outlets 3 Plug your peripheral equipment or non critical loads printer scanner fax speaker etc into the Surge Protection outlets These outlets provide surge and spike protection only they will NOT provide battery backup power during a utility power failure Connect your computer to the UPS using USB cable provided 4 5 With your equipment turned off switch on the UPS 6 When the On Off LED light is illuminated turn on the connected equip
7. ment 7 Install Power management software provided with the UPS User s manual 1023921 6 350 700 VA Revision A Typical applications 1 On Off Push Button Test Switch One switch controls the power to your equipment Upon power turn on unit performs a self test to detect overload or undercharged conditions Turn on the UPS Press and hold the push button switch depressed for more than one second Release the switch after the audible beep is sounded Turn off the UPS Press and hold the push button switch for more than one second and release the switch after the audible beep is sounded The UPS will shut down Self Test The UPS performs a self test for about 3 seconds when the UPS is turned on 1023921 User s manual Revision A 350 700 VA 7 2 On Off Battery LED Indicates the UPS is on and is powering your equipment A constantly illuminated LED indicates normal utility power operation A blinking LED indicates that the UPS is providing power from its battery 3 Fault Warning LED Indicates a fault or warning condition is present A constantly illuminated LED indicates a LOW battery condition A blinking LED indicates the UPS is overloaded 4 Battery Backup amp Surge Protection Outlets 4 IEC C13 output receptacles that provide both battery backup and surge protection 5 Surge Protection Outlets 4 IEC
8. port 2 2 2 0 cceeeeeeeeeeeeeee eee ee cee eee eeeeeeeeeseeseeeeeeeeseeeeeeeeeeneeee 11 Introduction The Powerware 3105 uninterruptible power system UPS filters the input line from line disturbances and protects your sensitive electronic equipment from five common power problems such as power failures power sags and power surges Features Eight outlets Four with surge and battery backup protection Four with surge protection only e Data Line Internet fax modem DSL or telephone line surge protection jacks Cold Start capability Proprietary LanSafe Power management software e User replaceable batteries Built in USB communication port Compact design fits on under your desk can also be mounted to a wall Unit inspection Once you have received the Powerware 3105 UPS product you should remove and inspect the product for shipping damage If any damage is found please notify the carrier and your dealer Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service Requesting for CE declaration Can be downloaded from http www powerware com Service support EMEA certificates asp Eaton Power Quality Oy Koskelontie 13 FIN 02920 Espoo Finland Phone 358 9 452 661 Fax 358 9 452 66 396 User s manual 1023921 4 350 700 VA RevisionA Safety Instructions N ATTENTION Maintenance other than battery replacement must be performed by
9. pushing the plunger back in Input Circuit Breaker has tripped UPS is making a continuous sound and the Overload indicator is lighted The Battery Backup amp Surge Protection outlets are overloaded Turn off the UPS and reduce the amount of equipment connected to these outlets Removed all connected equipments from the UPS and charge the battery at least 8 hours UPS does not provide During this charging period turn off the UPS expected runtime to prevent unnecessary discharging s Call for service or you can replace the battery by ordering one from your dealer Reduce the amount of equipment plugged into the outlets of the UPS Try reducing The UPS is overloaded the load by removing one piece of equipment at a time to determine if the problem continues The UPS will turn off when the battery has Connected equipment Tha UPS has exhausted its been depleted during an extended power loses power while i outage Allow the UPS to re charge the connected to the UPS available run time battery before continuing on battery operation Ensure the equipment that is to be Equipment is connected to the protected from a power outage is plugged surge Protection outlets into the Battery Backup amp Surge Protection outlets The UPS may require service Contact Powerware Technical Support The battery is not fully charged Service and Support For questions and or problems please call your local distributor or th
Download Pdf Manuals
Related Search
Related Contents
Emerson Basic Rack PDU - DI-STRIP White Paper 取り扱い説明書 INSTRUCTION MANUAL R2D_Bed Bed Topography File Editor User's Manual SENSIT 3 OPERATION AND SERVICE MANUAL 1 INSTALLATION & SERVICE MANUAL SERVICE MANUAL - e-ASP Graco 310791A User's Manual PDS Client Website User's Guide - Prairie Diagnostic Services Inc. 食品放射能測定システム 形名:CAN-OSP Copyright © All rights reserved.