        APC SURTA2200XL uninterruptible power supply (UPS)
         Contents
1.       Follow the prompts to choose a name and select an icon  Disregard the message      must install a  modem   if it is displayed  Click OK         Select the COM port that is connected to your UPS  The port settings are   e bits per second   2400    e data   bits 8   e parity   none   e stop bit   1   e flow control   none        Press ENTER  Press 1 to modify the UPS parameters   Follow the prompts     Exit the terminal program     A    For Windows users  START the PowerChute Server using the following steps        From the Desktop  go to Start   gt  Settings   gt  Control Panel   gt  Administrative Tools   gt  Services       Select APC PowerChute Server   right click the mouse and select Start    9  For Linux users  START the PowerChute Server using the following steps        Change directory to  etc init d         Initiate the command   PowerChute start     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Troubleshooting    Problem and Possible Cause    Solution       The UPS will not turn on or there is no output       The unit has not been turned on     Press the ON button once to turn on the UPS        The UPS is not connected to utility  power     The input circuit breaker has tripped     The unit shows very low or no input  utility voltage     Ensure that the power cable is securely connected to the utility power supply     Reduce the load to the UPS  disconnect nonessential equipment and reset the  circuit breaker     Check the utility power s
2.     Emergency Power Off  EPO  terminal allows the user to connect the UPS to a  central EPO system     SITE WIRING FAULT indicator the LED illuminates when the UPS detects a  building wiring fault    TVSS GND The UPS features a chassis ground located on the UPS rear panel  for connecting the ground leads on transient voltage devices   Outlets for connecting electronic equipment    UPS power cable for connecting to utility power     SmartSlot for optional NMC or PowerChute accessories     0000 O O O    External battery pack connector  The UPS will support up to 10 XLBPs     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Specifications    Operating 0   to 40   C  32   to 104   F    15   to 45   C  5   to 113   E   charge UPS battery every six months    Temperature  Storage       Maximum Operating 3 000 m  10 000 ft        Elevation  Storage 15 000 m  50 000 ft        Humidity 0  to 95  relative humidity  non condensing    Installation    This unit is intended for indoor use only   Select a location sturdy enough to handle  the weight     Do not operate UPS where there is  excessive dust or temperature or humidity  are outside specified limits     This unit has side air vents  Allow  adequate space for proper ventilation     Environmental factors impact battery life   High temperatures  poor utility power  and  frequent  short duration discharges will  shorten battery life     Units may vary in appearance from those depicted in this manual     Always place
3.    Arc       be   Su  O by Schneider Electric   Su SS   N    SS      Installation and Operation    a   Smart UPS      Uninterruptible Power Supply  Tower Rack Mount 2U   SURTA 1500XL 1500RMXL2U 1500XLJ  2200XL 2200RMXL2U   100 120 Vac                  This manual and the safety guide are available in English on the enclosed CD and the APC Web site  www apc com   Este manual y la gu  a de seguridad est  n disponibles en espa  ol en el CD adjunto y en el sitio Web de APC  www apc com     Ce manuel et le guide de s  curit   sont disponibles en frangais sur le CD ROM ci inclus et sur le site Web d APC  www apc com           KREROBREAA FO HAGA   HARO CD RU APC O Web Y4 h  www  apc  com  265 2 HEBE                 DI wok  4    XAO ANX EF 4 wowany yous  gt    pal O    ot POL OF  X          EARL RE MAS CD H APC Wih Cwww apc com  FJ AFH aR CHAS                   Smart UPS      Uninterruptible Power Supply  Tower Rack Mount 2U    SURTA1500XL 1500RMXL2U 1500XLJ  SURTA2200XL 2200RMXL2U    100 120 Vac    English    Overview    The APC   by Schneider Electric Smart UPS   SURTA1500XL 2200XL is a high performance  uninterruptible power supply  UPS   It provides protection for electronic equipment from utility power  blackouts  brownouts  sags  and surges  small utility fluctuations and large disturbances  The UPS also  provides battery backup power until utility power returns to safe levels or the batteries are fully  discharged     Inventory    All models 120 Vac models  e UPS e PowerChute 
4.   Utility CD  e Front bezel   USB communication cable    e Serial communication cable   e Literature kit containing      Product documentation     Smart UPS   User Manuals CD     Safety Guide       Warranty information    Accessories    Install accessories prior to connecting power to the UPS     Refer to the APC Web site  www apc com for available accessories     Optional accessories      External battery pack  XLBP     USB communication cables  e Network Management Card  NMC     Safety    DM Read the Safety Guide included in the package before installing the UPS   Inspect the UPS upon receipt  Notify the carrier and dealer 1f there is damage   we Recycle the packaging     wm        2 SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Product Overview    Front display panel                Load Battery Charge  085  APC 096   068  el2 7 0 072   051  ol  e 2 lo 048   034  l   e o   l 024   017       2 g      0  lt 24   o  OOo  su0311b  Button or  Indicator Description   1  The ON button  has three functions     Press this button to turn on the UPS    Press this button to initiate a Cold Start  Cold Start is not a normal condition  When there is  no utility power and UPS is off  press and hold this button to restore power to UPS  UPS  will emit two beeps  During second beep  release the button    Press this button to initiate a Self Test    Automatic  The UPS performs a self test automatically when turned on  and every two  weeks there after by default  During
5.  UPS above XLBPs in rack mount configuration     The unit is heavy  Remove the battery prior to installation     Prior to connecting utility or battery power to the UPS connect the transient voltage    surge suppression  TVSS  screw     Rack Mount and Stack Configurations    Refer to the installation guide supplied with the rail kit for rack mount configuration instructions     Tower Configuration    The UPS is shipped with stabilizer brackets installed  Do not remove the stabilizer brackets when  the UPS is to be operated in tower configuration  Removal of the stabilizer brackets for tower  configuration may result in personal injury or equipment damage     External Battery Pack s     Refer to the user manual supplied with the external battery pack for installation instructions     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Operation    Connect equipment to the UPS    A O A    Connect equipment to UPS  Do not use extension cords  plug equipment directly into the UPS outlets   If applicable  connect equipment to the serial or USB ports   Add optional accessories to the SmartSlot     For additional system security  install PowerChute software  Refer to the PowerChute Utility CD for  instructions     External battery packs provide extended runtime during power outages  Refer to the APC Web site   www apc com for external battery pack purchase information  Refer to the external battery pack user  manual for installation instructions     Connect the Int
6.  battery  packing material     Prepare the UPS for transport    E oa    Disconnect the UPS from all internal and external batteries   Shut down and disconnect all equipment connected to the UPS   Shut down and disconnect the UPS from utility power     Follow shipping instructions outlined in    Service    on page 13 of this manual     12 SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Service    If the UPS requires service do not return it to the dealer  Follow these steps     1  Review the problems discussed in    Troubleshooting    on page 10 in this manual to eliminate common  problems     2  Ifthe problem persists  contact APC Customer Support through the APC Web site  www apc com   a  Note the model number of the UPS  the serial number located on the rear side of the unit   and the date purchased  If you call APC Customer Support  a technician will ask you to    describe the problem and attempt to solve it over the phone  If this is not possible  the  technician will issue a Returned Material Authorization Number  RMA       b  If the UPS is under warranty  repairs are free     c  Procedures for servicing or returning products may vary internationally  Refer to the APC  Web site for country specific instructions     3  Pack the UPS in its original packaging  If this is not available  refer to www apc com for information about  obtaining a new set     a  Pack the UPS properly to avoid damage in transit  Never use Styrofoam beads for  packaging  Damage
7.  self test  UPS briefly operates on battery power   Manual  Press and hold ON button for a few seconds to initiate self test                    O O The Off button  This button is used to switch UPS off   Bypass    The Bypass LED illuminates indicating that the UPS is in bypass mode  Utility power is sent  LF directly to connected equipment during bypass mode operation  Bypass mode operation is the  result of an internal UPS fault  an overload condition or a selection made through NMC or  PowerChute software   Battery operation is not available while the UPS is in bypass mode   Refer to    Troubleshooting    on page 10 in this manual   On Battery O The On Battery LED illuminates indicating that the UPS is supplying battery power to      connected equipment    GO The On Line LED illuminates when the UPS is drawing utility power and performing double  Online conversion to supply power to connected equipment   Overload O The Overload LED illuminates indicating that the UPS is experiencing an overload condition   20 Refer to    Troubleshooting    on page 10 in this manual   A  Fault O The Fault LED illuminates indicating that the UPS detects an internal fault   X Refer to    Troubleshooting    on page 10 in this manual   Battery O The Battery Fault illuminates indicating that one or more batteries are disconnected or must be  Fault replaced     Refer to    Troubleshooting    on page 10 in this manual     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Front D
8.  sustained in transit is not covered under warranty     b  Always DISCONNECT THE UPS BATTERY before shipping in compliance with U S   Department of Transportation  DOT  and IATA regulations  The battery may remain in  the UPS     4  Mark the RMA  on the outside of the package   5  Return the UPS by insured  prepaid carrier to the address given to you by Customer Support     Contact Information    APC Worldwide Customer Support    Customer support for this or any other APC product is available at no charge in any of the following ways   e Refer to the APC Web site to access documents in the APC Knowledge Base and to submit customer  support requests         www apc com  Corporate Headquarters   Connect to localized APC Web sites for specific countries  each of which provides customer support  information         www apc com  Global support searching APC Knowledge Base and using e support     e Contact an APC Customer Support center by telephone or e mail   Local  country specific centers   go to www apc com for information     Contact the APC representative or other distributor from whom you purchased your APC product for information  on how to obtain local customer support     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U 13    Limited Warranty    Two Year Warranty    The limited warranty provided by American Power Conversion  APC    in this statement of Limited Factory Warranty applies only to products you  purchase for your commercial or industrial use 
9. Description  Automatic On startup and every e On startup and every Set the interval at which the UPS will  Self Test 14 days  336 hours  7 days  168 hours  execute self tests    there after there after  e On startup and every 14  days   336 hours  there after    e On startup only  e No self test       UPS ID UPS_IDEN Use a maximum of eight Uniquely identify the UPS  i e  server name  alphanumeric characters to or location for network management  define a name for the UPS  purposes                 Date of Last Manufacture mm dd yy Reset this date when the battery module is  Battery Date replaced   Replacement  Minimum Capacity 0 percent e 0  e 60  Specify the percentage to which batteries  Before Return from e 15  e 75  will be charged following a low battery  Shutdown e 30  e 90  shutdown  before sending power to  connected equipment   Alarm Delay Enable e Enable e Disable Specify the delay between an event and the  Control e Mute alarm to avoid alarms for insignificant  events   Shutdown Delay 90 seconds e O sec e 360 sec Specify the delay between the UPS  e 90 sec e 450 sec shutdown command and the actual    e 180 sec e 540 sec shutdown   e 270 sec e 630 sec          Duration of 2 minutes e 2 min e 14 min Specify the number of minutes before  Low Battery e 5 min e 17 min system shutdown  after the low battery  Warning e 8 min e 20 min warning   e 11 min e 23 min  Synchronized 0 seconds e O sec e 240 sec Specify the delay between the return of  Turn on Delay e 60 sec e 300 s
10. UIPMENT  LOSS OF USE OF EQUIPMENT  LOSS OF SOFTWARE   LOSS OF DATA  COSTS OF SUBSTITUENTS  CLAIMS BY THIRD PARTIES  OR OTHERWISE     NO SALESMAN  EMPLOYEE OR AGENT OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY   WARRANTY TERMS MAY BE MODIFIED  IF AT ALL  ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT     Warranty claims   Customers with warranty claims issues may access the APC customer support network through the Support page of the APC Web site  www apc com   support  Select your country from the country selection pull down menu  Open the Support tab at the top of the Web page to obtain contact information  for customer support in your region        2009 APC by Schneider Electric  APC  the APC logo  and Smart UPS are owned by Schneider Electric Industries S A S   American Power  Conversion Corporation  or their affiliated companies  All other trademarks are property of their respective owners     14 SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Radio Frequency Warning    120 Vac models    This equipment has been tested and found to comply with the limits for a Class A digital device  pursuant to part 15  of the FCC Rules  This equipment has also been tested and found to comply with the limits for a Class B digital  device  These limits are designed to provide reasonable protection against harmful interference when the  equipment is operated in a commercial environment for Class A and a residential environment for Cl
11. ass B     This equipment generates  uses  and can radiate radio frequency energy and  if not installed and used in accordance  with the instruction manual  may cause harmful interference to radio communications  Operation of this equipment  in a residential area may cause harmful interference  The user is responsible for correcting the interference     e Reorient or relocate the receiving antenna   e Increase the separation between the equipment and the receiver   e Connect the equipment and receiver to outlets on different circuits     e Consult the dealer  contact APC at the Web site or consult a qualified radio TV technician for assistance     Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits     100 Vac models    CORES  PHUBRES SES AMAS  VOCNOR  LCES lt  77 2153  HMRETI  CORBERE RACERS SCERPGESE Se RCT CEMHWET   COBSIEAESBISGNREBT SAS BRENSCEPOWET  VCCI A    SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    15    990 3622 7 2009    
12. e is no utility power and the  UPS is off     Use the Cold Start feature to supply power to connected equipment from UPS  battery s      Press and hold the ON button  There will be a short beep followed by a longer  beep  Release the button during second beep        Diagnostic utility voltage feature       All five LEDs are illuminated     There is no LED illumination     On Line indicator    The line voltage is extremely high and should be checked by an electrician     The line voltage is extremely low and should be checked by an electrician        There is no LED illumination     The UPS is running on battery  or it must be turned on        The LED is blinking     The UPS is running an internal self test     Maintenance and Transport    Battery replacement    This UPS has a replacable  hot swappable battery module  Replacement is a safe procedure  isolated from electrical  hazards  Leave the UPS and connected load on during the replacement procedure     Once the battery modules have been disconnected the connected equipment is not protected from    power outages     When the battery modules have been replaced the LED on the display interface will prompt the user to  enter a new battery replacement date     Refer to the appropriate replacement battery user manual for installation instructions  See your dealer or contact  APC at www apc com for information on replacement batteries     Be sure to deliver spent batteries to a recycling facility or ship to APC in the replacement
13. ec utility power and the UPS turns on  Set the  e 120 sec e 360 sec interval to avoid a branch circuit overload  e 180 sec e 420 sec condition   High Bypass Points 100 Vac models e 107 Vac e 119 Vac Maximum voltage that the UPS will pass to  110 Vac e 110 Vac e 122 Vac connected equipment during internal bypass    e 113 Vac e 125 Vac operation   e 116 Vac e 128 Vac    120 Vac models e 127 Vac e 139 Vac  133 Vac e 130 Vac e 142 Vac  e 133 Vac e 145 Vac  e 136 Vac    148 Vac       SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U             Function Factory Default Options Description  Low Bypass Points 100 Vac models e 78 Vac e 86 Vac Minimum voltage that the UPS will pass to  78 Vac e 80 Vac e 88 Vac connected equipment during internal bypass  e 82 Vac e 90 Vac operation   e 84 Vac e 92 Vac  120 Vac models e 86 Vac e 94 Vac  86 Vac e 88 Vac e 96 Vac  e 90 Vac e 98 Vac  e 92 Vac e 100 Vac  Output Frequency Automatic selection Automatic Specify the UPS output frequency   between  50  0 1 Hz Whenever possible the output frequency  50 3 Hz 50   3Hz should track the input frequency   60   3 Hz 60   0 1 Hz  60   3 Hz       Number of Battery 1    Packs    packs    Number of connected battery    Emergency Power Off  EPO     The Emergency Power Off  EPO  option is a safety feature that will immediately remove power to all connected  equipment  When EPO button is pushed  all connected equipment will immediately turn off and will not switch to  battery power     Define
14. en operated at elevated  temperatures  If the battery is near the end of its service life  consider replacing  the battery even if the Replace Battery LED indicator is not yet illuminated        A UPS overload condition has occurred     Check the UPS Load indicator  Disconnect nonessential equipment        Site Wiring Fault indicator is illuminated       The UPS is connected to an improperly    wired utility outlet     Wiring faults detected include missing ground  hot neutral polarity reversal  and overloaded neutral circuit     Do not attempt to use the UPS  Disconnect the UPS from utility and battery  power  Contact a qualified electrician to correct the building wiring        All indicators are off and the UPS is connected to utility service    The UPS has been shut down or the    batteries are discharged from extended    usage     None  The UPS will restart automatically when utility power returns and  configuration criteria have been met     10 SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Problem and Possible Cause Solution       All indicators flash sequentially    The UPS has been shut down remotely None  The UPS will restart automatically when utility power returns   through software or an optional accessory  card        All indicators are illuminated and the UPS emits a constant beeping sound       The UPS detects an internal fault  Do not attempt to use the UPS  Disconnect the UPS from utility and battery  power  Have the UPS serviced immed
15. ernal Battery and  Install the Bezel    The UPS is shipped with the internal battery disconnected     l   2     Remove the battery compartment cover  O    Remove the warning label and protective sticker from the battery connector  Place the sticker on the back  of the battery compartment cover for re use     Snap the battery connectors together  2   Reinstall the battery cover          Install the front bezel  O                O                                                                                                                                                                               su0072b             Connect Power and Start the UPS    The UPS will charge to 90  capacity in the first four hours of normal operation  Do not expect full  battery run capability during this initial charge period       Connect the UPS to the building utility power  Connect the UPS into a two pole  three wire  grounded    receptacle     Press the On button the front display panel of the UPS to apply power to the unit and all connected  equipment     To use UPS as a master on off switch turn on all the equipment that is connected to the UPS     Configure the Network Management card  NMC   if installed  Refer to NMC documentation for  instructions     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    Configuration    UPS Settings    Configure the settings using PowerChute software  a network management card or terminal mode        Function Factory Default Options 
16. iately        Battery Fault indicator is illuminated    The Battery Fault LED flashes and a Check that the battery connectors are fully engaged   short beep is emitted every two seconds  to indicate the battery is disconnected           Weak battery  Allow battery to recharge for 24 hours and perform a self test  If the problem  persists after recharging  replace battery    Failure of a battery self test  Battery Allow battery to recharge for 24 hours  Perform the self test procedure to   Fault LED illuminates and the UPS confirm the replace battery condition  The alarm stops and the LED clears if   emits short beeps for one minute  The the battery passes the self test    UPS repeats the alarm every five hours  If battery fails again  it must be replaced  The connected equipment is  unaffected        Bypass indicator is illuminated    Bypass mode has been turned on through If bypass mode has been selected  ignore the LED   an accessory        Overload indicator is illuminated and the UPS emits a sustained alarm tone       A UPS overload condition exists  Disconnect nonessential equipment from UPS to eliminate overload condition        Bypass and Overload indicators are illuminated and the UPS emits a sustained alarm tone    A UPS overload condition has occurred  Connected equipment exceeds specified    maximum load    as defined in  Specifications on APC Web site  www apc com     The alarm remains on until the overload is removed  Disconnect nonessential  equipment from UPS t
17. in the ordinary course of your business     Terms of warranty   APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase  The obligation of  APC under this warranty is limited to repairing or replacing  at its sole discretion  any such defective products  This warranty does not apply to  equipment that has been damaged by accident  negligence or misapplication or has been altered or modified in any way  Repair or replacement of a  defective product or part thereof does not extend the original warranty period  Any parts furnished under this warranty may be new or factory   remanufactured     Non transferable warranty  This warranty extends only to the original purchaser who must have properly registered the product  The product may be registered at the APC Web site   WWW apc com     Exclusions   APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by  end user or any third person misuse  negligence  improper installation or testing  Further  APC shall not be liable under the warranty for unauthorized  attempts to repair or modify wrong or inadequate electrical voltage or connection  inappropriate on site operation conditions  corrosive atmosphere   repair  installation  start up by non APC designated personnel  a change in location or operating use  exposure to the elements  Acts of God  fire  theft  or  ins
18. isplay Panel    Feature  100V 120V  0118 0 0 138 2  0 108 7 0 128 8  099 3 0 119 5  090 0 0 110 1  080 6 0 100 8  Rear panel                        a  e Kil   i  e   0                                Go             co  E  DT  co oO  Oo  DT  co oO  O  E    m              suo0523a    Description    The UPS has a diagnostic feature that indicates utility voltage    The UPS starts a self test as part of this procedure  The self test does not affect voltage  display    Press and hold the ON button to view utility voltage bar graph indicator  As soon as the On  Line LED starts flashing indicating a self test is in progress  the five LED Battery Charge  indicator to the right of the display panel will show utility input voltage     Refer to diagram for voltage reading   Values are not listed on the UPS     Indicators on the UPS show the voltage is between the displayed value on list and the next  higher value     Refer to    Troubleshooting    on page 10 in this manual     O SERIAL COM serial communication port for   Power management software    0 Interface kits    Use only interface kits supplied or approved by APC  Any other serial  interface cable will be incompatible with UPS connector     Serial and USB communication ports cannot be used simultaneously      7   0  _ USBCOM USB communication port    120 Vac models  USB communication cable    100 Vac models  USB communication cables and software are available as  accessories     Contact APC at www apc com for purchase information 
19. o eliminate overload condition     The UPS continues to supply power as long as it is on line and the circuit  breaker does not trip  The UPS will not provide power from batteries in the  event of a utility voltage interruption     Fault indicator is illuminated       An internal UPS fault has occurred  Do not attempt to use UPS  Turn UPS off and have it serviced immediately   Refer to APC Web site  www apc com        Bypass and Fault indicators are illuminated and the UPS emits a sustained alarm tone    The UPS has automatically switched to In the event an internal UPS fault occurs  Do Not attempt to use UPS  Turn  Bypass mode  Bypass mode operation UPS off and have it serviced immediately  Refer to APC Web site    is the result of an internal UPS fault or  www apc com    an overload condition while operating   on utility power     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U 11    Problem and Possible Cause    Solution       Fault and Overload indicators are illuminated and the UPS emits a sustained alarm tone       The UPS is not sending power to  connected equipment     Connected equipment exceeds specified    maximum load    as defined in  Specifications on APC Web site  www apc com    The alarm remains on until the overload is removed  Disconnect nonessential  equipment from UPS to eliminate overload condition    The UPS will not provide power from batteries in the event of a utility voltage  interruption        There is no utility power       Ther
20. plenums  and other spaces used for environmental air     CL2R  Riser cable for use in a vertical run in a floor to floor shaft     CLEX  Limited use cable for use in dwellings and for use in raceways     For installation in Canada  Use only CSA certified  type ELC   extra low voltage control cable      For installation in other countries  Use standard low voltage cable in accordance with national and local    regulations     SURTA 1500XL 1500XLJ 2200XL Series 100 120 Vac Tower Rack Mount 2U    TERMINAL MODE TO  CONFIGURE UPS PARAMETERS    Terminal Mode is a menu driven interface that enables configuration of the UPS by users not wishing to use  PowerChute   software or an optional Network Management Card     Connect the serial cable to the serial com connector on the back of the UPS   If PowerChute software is not installed do not perform steps 1  2  8 and 9   1  For Windows users  STOP the PowerChute Server using the following steps       From the Desktop  go to Start   gt  Settings   gt  Control Panel   gt  Administrative Tools   gt  Services       Select APC PowerChute Server   right click the mouse and select Stop   2  For Linux users  STOP the PowerChute Server using the following steps       Change directory to  etc init d       Initiate the command   PowerChute stop   3  Open a terminal program  Example  HyperTerminal      From the Desktop  go to Start   gt  Programs   gt  Accessories   gt  Communication   gt HyperTerminal   4  Double click on the HyperTerminal icon   
21. s the number of connected battery  packs for proper runtime prediction     1 internal battery module  2 one external battery pack    3 two external battery packs    Adhere to all national and local electrical codes  Wiring must be performed by a qualified electrician     The switch should be connected in a normally open switch contact  External voltage is not required  the switch is  driven by 12 V internal supply  In closed condition  2 mA of current are drawn     The EPO switch is internally powered by the UPS for use with non powered switch circuit breakers     Connect the EPO                                        The EPO connector is located on the rear panel of the UPS   1  Strip insulation from one end of each wire to be used for connecting EPO     2  Insert a screwdriver into the slot above the terminal to be wired  Insert stripped wire into  terminal  Remove screwdriver to secure wire in terminal  Repeat for each terminal     The EPO interface is a Safety Extra Low Voltage  SELV  circuit  Connect it only to other SELV circuits  The  EPO interface monitors circuits that have no determined voltage potential  Such closure circuits may be  provided by a switch or relay properly isolated from the utility  To avoid damage to the UPS  do not connect    the EPO interface to any circuit other than a closure type circuit     Use one of the following cable types to connect the UPS to the EPO switch     CL2  Class 2 cable for general use     CL2P  Plenum cable for use in ducts  
22. tallation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered  defaced  or removed  or any  other cause beyond the range of the intended use     THERE ARE NO WARRANTIES  EXPRESS OR IMPLIED  BY OPERATION OF LAW OR OTHERWISE  OF PRODUCTS SOLD  SERVICED OR  FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH  APC DISCLAIMS ALL IMPLIED WARRANTIES OF  MERCHANTABILITY  SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE  APC EXPRESS WARRANTIES WILL NOT BE  ENLARGED  DIMINISHED  OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF  APC RENDERING OF  TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS  THE FOREGOING WARRANTIES AND  REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES  THE WARRANTIES SET FORTH ABOVE  CONSTITUTE APC SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES  APC  WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES     IN NO EVENT SHALL APC  ITS OFFICERS  DIRECTORS  AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT   SPECIAL  CONSEQUENTIAL OR PUNITIVE DAMAGES  ARISING OUT OF THE USE  SERVICE OR INSTALLATION  OF THE PRODUCTS   WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT  IRRESPECTIVE OF FAULT  NEGLIGENCE OR STRICT LIABILITY OR  WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES  SPECIFICALLY  APC IS NOT LIABLE  FOR ANY COSTS  SUCH AS LOST PROFITS OR REVENUE  LOSS OF EQ
23. upply to the UPS by plugging in a table lamp  If the  light is very dim  check the utility voltage        The battery connectors are not  securely connected     Ensure that all battery connections are secure        The UPS will not turn off       The unit has not been turned off     Press the OFF button once to turn off the UPS        There is an internal UPS fault     UPS beeps occasionally    Do not attempt to use the UPS  Disconnect the UPS from utility and battery  power  Have the UPS serviced immediately        The UPS is in normal operation     None  The UPS is protecting the connected equipment   Press the ON button to silence the alarm        The UPS is operating on battery  while connected to input utility power    The input circuit breaker has tripped     Reduce the load to the UPS  disconnect nonessential equipment and reset the  circuit breaker        There is very high  very low  or  distorted input line voltage     Move the UPS to a different outlet on a different circuit  Test the input voltage  with the utility voltage display        A connected generator is an  inappropriate size     XLJ models do not support the use of a generator   Check the UPS and generator specifications for compatibility        UPS does not provide expected backup time    The UPS battery is weak due to a  recent outage or is near the end of its  service life     Charge the battery  Batteries require recharging after extended outages and  wear out faster when put into service often or wh
    