Home
IBM eServer BladeCenter HS22
Contents
1. Versatile easy to use blade optimized for performance energy and cooling 2 5 inch SAS HDDs 10K RPM 73 4 146 8 300 500 or 600GB capacities 1 2TB maximum e 15K RPM 73 4 or 146 8GB capacity 293 6GB 2 5 inch SATA HDDs SATA 10K RPM 2 5 inch HDD 300GB capacities 600GB 2 5 inch SSDs SATA based 50GB single capacities 100GB maximum Due to the statistically higher failure rates for traditional spinning media IBM recommends the use of the solid state drives SSDs as an alternative They store data on flash memory chips rather than on magnetic media Like HDDs SSDs can be used as boot media and for random access storage However SSDs offer higher thresholds of shock and vibration and a higher operating temperature range between 0 and 70 degrees C This yields a failure rate only 1 3 that of HDDs approximately 3 000 000 hours MTBF vs 1 000 000 hours In addition the 2 5 inch SSDs require only 2W This reduces the storage power requirement and heat output by as much as 80 compared to 2 5 inch HDDs If used as a boot device no special device drivers are required High IOPS SSD PCle Adapters o IBM 160GB High IOPS SS Class SSD PCle Adapter x4 Gen 1 100K IOPS 750MBps IBM 320GB High IOPS SS Class SSD PCle Adapter x4 Gen 1 100K IOPS 750MBps IBM 320GB High IOPS MS Class SSD PCle Adapter x4 Gen 1 100K IOPS 750MBps IBM 320GB High IOPS SD Class SSD PCle Adapter x8 Gen 2 200K IOPS 1 5GBps I
2. BladeCenter Chassis IBM s blade architecture offers five choices of compatible and interoperable chassis in which to use various blade servers Each chassis serves different customer needs The new BladeCenter S is a small entry level chassis designed for office environments The original BladeCenter E chassis offers maximum density great flexibility and a wide variety of expansion options at an entry level price The next generation BladeCenter H chassis offers all of BladeCenter s capabilities and adds new high performance features If you need a ruggedized chassis for example government military or telecom BladeCenter T offers special features optimized for those environments HS22 is not supported in the BladeCenter T The next generation BladeCenter HT is a high performance ruggedized telecommunications platform There is a high degree of interchangeability and compatibility of features among the chassis Any or all of these chassis can be installed in a rack along with other rack optimized equipment See the separate BladeCenter Chassis Sales Guide for details Hot Swap Redundant Components System availability is maximized through the extensive use of hot swap and redundant components both in the blade server and in the various BladeCenter chassis including e Redundant memory protection with Chipkill error correction and memory mirroring or memory sparing enabled Hot swap redundant hard disk drives and solid state driv
3. Novell Netware IBM AIX IBM i and Sun Solaris 10 operating systems in the same chassis Most HS LS JS PS QS blade servers ever released by IBM are are supported in every BladeCenter chassis ever released going back to 2002 Every switch module released by IBM is equally compatible Ask HP and Dell how far back their compatibility goes A blade server has access to as many as 10 communication switches bridges in a BladeCenter H or 8 in a BladeCenter HT chassis Up to 4 switches in a BladeCenter E chassis And the switches can be Ethernet iSCSI SAS InfiniBand Fibre Channel or anything else designed and ServerProven for BladeCenter use Switches bridges and interface cards are currently available from such vendors as Brocade Cisco Intel QLogic Voltaire and others in addition to IBM BNT Manageability The HS22 blade server includes an Integrated Management Module IMM to monitor server availability perform Predictive Failure Analysis etc and trigger IBM Systems Director alerts The IMM performs the functions of both the Baseboard Management Controller BMC of earlier systems and the Remote Supervisor Adapter Il as well as remote presence cKVM Each BladeCenter chassis includes an Advanced Management Module to provide additional Systems management capabilities including Web based out of band control virtual floppy and CD ROM support Windows blue screen error capture LDAP and SSL support and remote redirection o
4. a spare for the other two channels ChO and Ch1 This means that unlike mirroring where one third of the memory is reserved for redundancy and one third is unused with sparing only one third is reserved leaving two thirds 8 DIMMs available as usable memory Note Although DIMMs within a channel do not have to be identical the DIMMs in each of the three channels must be identical to the other channels regarding capacity and organization In other words if the DIMMs in ChO are 2GB 2Rx4 and 8GB 1Rx8 respectively all 1 35V then the DIMMs in Ch1 and CH2 must also be 2GB 2Rx4 and 8GB 1Rx8 all 1 35V in that order DDR3 memory is available in 1GB 2GB 4GB 8GB and 16GB DIMMs DIMMs are installed individually not in pairs Integrated Virtualization All models of the x3550 M3 support a USB 2 0 Flash Key installed preloaded with VMware vSphere Hypervisor formerly ESXi Rather than management through a Service Console based on a Linux operating system vSphere Hypervisor relies on aggregate management tools including VirtualCenter the Remote Command Line interface and the introduction of CIM for standards based and agentless hardware monitoring vSphere Hypervisor includes all the performance scalability and compatibility features of a hypervisor installed on disk including full VMFS support across FC SAN iSCSI SAN and NAS and 4 way VSMP Because it runs from flash memory it s extremely fast and ideal for diskless configur
5. a zero gigabyte HDD footprint In other words no mechanical HDD to fail Optional solid state drives SDDs use only 2W of energy per drive vs 7 10W for 2 5 inch HDDs This is as much as 8096 less energy than a HDD would use with a corresponding reduction in heat output Low voltage 1 35V memory draws up to 19 less power than 1 5V DIMMs e Selected HS22 blade servers are planned for NEBSS ETSI compliance and feature long life availability These blades are ideal for telecom or Next Generation Network NGN applications such as IPTV IP Multimedia Subsystem IMS and security The extremely high degree of integration in the various BladeCenter chassis reduces the need for server components replacing numerous fans KVM and Ethernet cables power supplies external switches and other components with fewer shared hot swap redundant components in the BladeCenter chassis itself This integration also can greatly reduce the amount of power consumed and heat produced relative to an equivalent number of 1U servers This can significantly reduce a data center power bill The reduced datacenter footprint can also save on infrastructure cost The midplanes used in all chassis provide high speed blade to blade blade to switch module and module to module communications internally as well as externally The midplanes used in the BladeCenter H and BladeCenter HT chassis provide four 10Gb data channels to each blade and supports high speed swit
6. threads per core and Intel Turbo Boost technology e 130W 4 core Xeon 5600 model X5647 running at 2 93GHz with impressive performance 32 5W per core 5 86GTps QPI speed 12MB of L3 processor cache 1066Hz memory access 2 threads per Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter E and BladeCenter T e 60W four core Xeon 5600 series model L5640 at 2 26GHz with low power draw and impressive performance watt only 10W per core 5 86GTps QPI speed 12MB of shared L3 cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 80W four core Xeon 5600 series models E5640 and E5620 at 2 66 and 2 4GHz with reduced power draw and impressive performance watt only 20W per core 5 86GTps QPI speed 12MB of shared L3 cache 1066MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 40W 4 core Xeon 5600 series low voltage model L5609 running at 1 86GHz with extremely low power draw and amazing performance watt only 10W per core 4 8GTps QPI speed 12MB of L3 processor cache and 1066MHz memory access supported in all BladeCenter chassis e 80W 4 core Xeon 5600 series model E5
7. total 12 ports per blade support for 10Gb Ethernet Flexibility e Single to five wide configurations blade server and up to 4 I O expansion units Large memory capacity Up to 192GB standard using twelve 8GB DIMMs Achoice of hard disk or solid state storage High capacity disk storage Up to 1 2TB of internal SAS or 1TB of SATA storage with the option for additional 2 5 inch SAS HDDs in the BladeCenter S chassis e Optional IBM 50GB Solid State Drive as an energy saving alternative to HDD storage e Optional IBM 160GB 320GB or 640GB High IOPS SSD Adapters for extremely high IOPS and bandwidth storage requires BPE4 expansion unit Integrated RAID RAID 1 mirrored arrays standard enhanced RAID 1E 5 arrays optional using a BladeCenter S chassis RAID 5 arrays also available using an optional ServeRAID MR10ie controller Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Two available adapter slots standard m Two CFF compact form factor slots one high speed CFFh and one standard speed ClOv e Additional optional adapter slots Q Up to 3 total using 1 BladeCenter PCI Express I O Expansion Unit 3 blade Q Up to 10 total using 4 BladeCenter PCI Express Gen 2 Expansion Blades BPE4 blades Manageability and Availability e IBM Systems Director systems management software including e Integrated Managem
8. 0 x 16 bit color at 85Hz Gigabit Ethernet controllers standard of Gigabit Ethernet ports 2 standard Maximum 12 None 1 direct via BladeCenter H chassis or Serial over LAN in BladeCenter E and BladeCenter H H Using the 4 Port Ethernet Expansion Card an I O Expansion Unit and a Multi Switch Interconnect Module in a BladeCenter H chassis Dual port Broadcom BCM5709S TOE enabled of serial ports f 18 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling BladeCenter HS22 Specifications Diagnostic LEDs front panel Power good blade location over temperature information general fault Predictive Failure Analysis support Processor memory HDDs expansion cards BIOS type UEFI 2 1 Power supply size Contained in chassis of power supplies standard Contained ireh ssis maximum of fans blowers standard Contained chassis maximum 9 7 245mm H Dimensions HWD weight 1 14 29mm W 17 6 446mm D 12 Ibs maximum 5 44 kg maximum Microsoft Windows Server 2008 Microsoft Windows Small Business Server 2008 Microsoft Windows Server 2003 and R2 Standard Web Enterprise Editions 32 bit and Operating systems supported 64 bit RHEL 5 3 32 bit and 64 bit with or without Xen RHEL 5 3 32 bit SLES 11 32 bit and 64 bit with or without Xen Sun Solaris 10 VMware vSphere Hypervisor 3 5 4 0
9. 4 5 6 or 4 8 GTps gigatransfers per second depending on the processor model The six core Xeon processors contain six complete processor cores The processors also contain one shared 12MB cache The shared cache is dynamically allocated among cores as needed The six cores appear to software as six physical processors The six core processors offer considerably higher performance than a same speed Xeon processor with four cores Turbo Boost Technology dynamically turns off unused processor cores and increases the clock speed of the cores in use by up to two model frequencies For example a 2 93GHz 6 core X5670 processor with 3 6 cores active can run the cores at 3 2GHz With only one or two cores active the same processor can run those cores at 3 33GHz Similarly a 2 26GHz 4 core L5640 processor can run at 2 53GHz 2 66GHz or even 2 8GHz When the cores are needed again they are dynamically turned back on and the processor frequency is adjusted accordingly Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling In processors implementing Intel Hyper Threading Technology each core has two threads capable of running an independent process Thus a 6 core processor can run 12 threads concurrently Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw Execute Disable Bit func
10. 607 running at 2 26GHz with reduced power draw and impressive performance watt 20W per core 4 8GTps QPI speed 8MB of L3 processor cache and 1066MHz memory access e 80W 4 core Xeon 5600 series model E5603 running at 1 6GHz with reduced power draw and impressive performance watt 20W per core 4 8GTps QPI speed 8MB or 4MB respectively of L3 processor cache and 1066MHz memory access e 80W four core Xeon 5500 series model E5507 at 2 26GHz with reduced power draw and impressive performance watt only 20W per core 4 8GTps QPI speed 4MB of shared L3 cache and 800MHz memory access supported in all BladeCenter chassis except BladeCenter T e 80W two core Xeon 5500 series model E5503 at 2 0GHz with reduced power draw and impressive performance watt only 20W per core 4 8GTps QPI speed 4MB of shared L3 cache and 800MHz memory access supported in all BladeCenter chassis except BladeCenter T Also available via configure to order CTO e 130W 4 core Xeon 5600 series model X5687 running at 3 6GHz with impressive performance 32 5W per core 6 4GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter E and BladeCenter T e 80W 6 core Xeon 5600 series models E5645 at 2 4GHz with reduced power draw and impressive performance watt only 13 33W per core 5 86GTps QPI speed 12MB of shared L3 cache 1333MHz memory acc
11. 6GHz X5687 C7x Four core Xeon E55xx 2 26GHz E5507 A4x 80W A4x A5x A7x B6x D3x 60W N2x G2x G4x GCx plus L5630 via plus CTO E5606 E5645 via CTO 40W L5609 L5618 via CTO 12MB shared cache A5x A7x B5x B6x C5x C6x C7x C8x F2x F3x G2x G4x GCx H2x H4x H5x HAx N2x plus E5645 L5609 L5618 L5630 viq CTO 4MB shared cache A4x A5x A7x D3x plus E5606 via CTO 6 4 GTps B6x C5x C6x C7x C8x F2x F3x H2x H4x H5x HAx 1333MHz B6x C5x C6x C7x C8x F2x F3x H2x H4x H5x HAx N2x plus E5645 L5630 via CTO 5 86 GTps A5x A7x B5x G2x G4x GCx N2x plus E5606 E5645 L5630 via CTO 4 8 GTps A4x A5x A7x D3x plus E5606 via CTO 1066MHz A5x A7x B5x G2x G4x GCx plus E5606 L5609 L5618 800MHz A4x A5x A7x D3x plus E5606 via CTO 1 2 maximum NEBS ETSI Compliance Select blades are NEBSS ETSI compliant Contact IBM sales for details Intel 5520 6GB 3 x 2GB 192GB F2x F3x G2x G4x GCx H2x H4x H5x HAx N2x Chipset 12GB 3 x 4GB 288GB B5x B6x C5x C6x C7x C8x 4GB 1 x 4GB 288GB A5x A7x 3GB 3 x 1GB 192GB A4x D3x Standard maximum memory Registered DDR3 ECC operating at 1333MHz 1066MHz or 800MHz depending on Standard memory type processor and memory configuration Memory interleaving Yes DIMM capacities supported 1GB 2GB 4GB 8GB when available Chipkill protection supported Yes using x4 DIMMs 12 9 2 2 SAS S
12. ATA SSD Standard 1 2TB 2 x 600GB hot swap of DIMM sockets total available of 2 5 inch drive bays total available of 3 5 inch drive bays total available Maximum internal 2 5 HDD capacity Maximum memory and disk capacity may require the replacement of standard components with the largest supported component available 17 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling BladeCenter HS22 Specifications SAS 73 4 146 8 300 500 2 5 inch drive capacities supported 600GB 10K RPMs 73 4 146 8GB 15K RPMs SATA 300 500GB 10K RPMs Solid State SFF HS 50GB of HDDs standard 160GB High IOPS SS Class SSD PCle Adapter 320GB High IOPS SS Class SSD PCle Adapter 320GB High IOPS SD Class SSD PCle Adapter 320GB High IOPS MS Class SSD PCle Adapter 640GB High IOPS MLC Duo Adapter Optional 2GB preloaded with VMware vSphere Hypervisor formerly ESXi External disk drive support NAS SAN attach Additional Internal SSD storage via PCIe adapter 2 x16 mechanical x8 electrical slots 2 x16 mechanical x8 electrical slots included up to 3 total using 1 BladeCenter included up to 10 total using 4 PCI Express I O Expansion Unit 3 BladeCenter PCI Express Gen 2 BPES3 blade Expansion Blade BPE4 blades of PCle slots Maximum video resolution at 32 bit color 1600 x 120
13. BM 640GB High IOPS MLC Duo Adapter x8 Gen 2 200K IOPS 1 5GBps For read intensive transactional workloads requiring extreme IOPS performance such as database video on demand and caching IBM offers High IOPS SSD PCle Adapters equivalent to the IOPS output of approximately 500 3 5 inch 600GB 15K SAS HDDs with 99 lower latency 30 us and 7 7x the bandwidth of a HDD On a performance per watt basis these adapters outperform HDDs by up to 445x Because these adapters go in PCle slots rather than drive bays they can be used in addition to standard HDDs and SSDs This makes them ideal for virtualized servers running multiple tasks requiring both write and read intensive storage media As flash media they also offer a predictable lifetime compared to the sporadic failure rate of HDDs using N 1 chip level redundancy and 11 bit ECC protection Note The High IOPS Adapters require a BPE4 expansion unit O O O O Additional storage is available via the BladeCenter S chassis If you need more storage space terabyte capacities are possible with optional external iSCSI and SAN storage solutions External Tape Storage The HS22 supports various external rack mounted SAN attached tape drives Supported tape technologies include IBM LTO3 2U Autoloader IBM LTO3 4U Tape Library e IBM System Storage TS2230 Express Tape Drive e IBM System Storage TS2240 Tape Drive Model H4S e IBM System Storage TS3100 or TS3200 Tape Libr
14. M and concurrent media cMedia access by multiple administrators at once via the IMM e IBM Systems Director is included for proactive systems management and works with both the blade s internal IMM and the chassis management module It comes with a portfolio of tools including BM Systems Director Active Energy Manager Service and Support Manager and others In addition IBM Systems Director offers extended systems management tools for additional server management and increased availability When a problem is encountered IBM Systems Director can issue administrator alerts via e mail pager and other methods Availability and Serviceability e BladeCenter chassis are designed for operation with greatly reduced potential for single points of failure Most aspects of operation from blade servers to communication modules to management modules to power and blower modules are hot swappable The midplane connections are redundant and the other features can be made so when used in pairs e HS22 blade servers support the use of Chipkill enabled ECC error checking and correcting memory Chipkill memory can be up to 16X better than standard ECC memory at correcting some types of memory errors This can help reduce downtime caused by memory errors Optional memory mirroring and memory sparing offer additional redundancies Solid state drives offer up to triple the availability MTBF rates of conventional SAS HDDs This can lessen the n
15. Update 4 Extended long life support Select blades are supported for long life Contact IBM sales for details Length of limited warranty 3 years parts and labor onsite The Bottom Line The HS22 offers maximum bang for the buck by incorporating outstanding features in a tiny package Price Performance Multi core processors Up to two 2 0 to 3 46GHz six core or 1 6 to 3 6GHz four core Xeon 5600 series processors or 2 26GHz four core or 2 0GHz two core Xeon 5500 series processors e Low voltage processors Up to two 60 watt six core or 40 watt four core Xeon 5600 series processors Large cache Up to 12MB of L3 processor cache processor specific Embedded virtualization via optional internal flash drive Fast memory access 1333MHz 1066MHz or 800MHz access depending on the processor model and DIMMs used 1333GHz memory access even with 2 DIMMs per channel processor Specific Fast memory access 1333MHz or 1066MHz registered DDR3 ECC memory e Fast disk technology Internal SAS or SATA storage 2 HDDs or BladeCenter S chassis RAID 0 data striping e High IOPS technology Optional High IOPS SSD adapters e Fastl O 10Gb Ethernet 10Gb CNA 4X InfiniBand 6Gb SAS or 8Gb Fibre Channel connectivity via an optional expansion card Fast communications Integrated dual Gigabit Ethernet with the option for two or four additional Gigabit Ethernet ports via expansion cards and expansion unit
16. Versatile easy to use blade optimized for performance energy and cooling Product Guide February 2011 Product Overview CONTENTS Product Overview Selling Features Key Features Key Options HS22 Images HS22 Specifications The Bottom Line Server Comparison For More Information Legal Information IBM BladeCenter HS22 No compromise truly balanced 2 socket blade server for infrastructure virtualization and enterprise business applications Suggested uses Front end and mid tier applications requiring high performance enterprise class availability and extreme flexibility and power efficiency Today s data center environment is tougher than ever You re looking to reduce IT cost complexity space requirements energy consumption and heat output while increasing flexibility utilization and manageability Incorporating IBM X Architecture features the IBM BladeCenter HS22 blade server combined with the various BladeCenter chassis can help you accomplish all of these goals Reducing an entire server into as little as 5U of rack space i e up to 14 servers in 7U does not mean trading away features and capabilities for smaller size Each HS22 blade server offers features comparable to many 1U rack optimized full featured servers The HS22 supports up to two of the latest high performance or low voltage 6 core 4 core and 2 core Intel Xeon 5500 series and 5600 series processors The Xeon processors are desig
17. Windows logo are trademarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products or services do not imply that IBM http ibm com systems bladecenter http ibm com support electronic http ibm com systems bladecenter resources powerconfig html http ibm com systems x hardware configtools html http ibm com systems x hardware configtools html http ibm com systems info x86servers serverproven compat us http ibm com server support http ibm com systems support intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This publication may contain links to third party sites that are not under the control of or maintained by IBM Access to any such third party site is at the user s own risk and IBM is not responsible for the accuracy or reliability of any information data opinions advice or statements made on these sites IBM provides th
18. With built in redundancy innovative power and cooling and the latest I O and management tools IBM BladeCenter is easy to own so you can focus on your business demands and stay ahead of the competition The RIGHT choice tailored to fit your diverse needs e It s flexible and modular As needs evolve a one size fits all solution doesn t work Meet your needs with BladeCenter everything from a high performance data center to a small office with limited IT skills IBM has you covered Get flexibility with 5 compatible chassis and 5 blade types supporting multiple I O fabrics all managed from a common point e Its robust and reliable providing redundancy throughout and the information you need to keep your business up and running Provide redundancy for no single point of failure with IBM BladeCenter Preserve application uptime with IBM Predictive Failure Analysis and light path diagnostics Make decisions based on accurate data for quick problem diagnosis with First Failure Data Capture OPEN and innovative for a flexible business foundation ts comprehensive providing broad fast and reliable networking and storage I O with BladeCenter Open Fabric For terms and conditions or copies of the IBM Statement of Limited Warranty call 800 772 2227 in the U S In Canada call 800 426 2255 Telephone support may be subject to additional charges For warranties including onsite labor a technician is sent af
19. abling costs and it allows clients to manage Chipkill protection on the HS22 requires x4 DIMMs Chipkill protection is not available with x8 DIMMs Actual data transfer speed will vary and is often less than the maximum possible Gigabit Ethernet transfer speed requires support on both System and server and appropriate network infrastructure Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling everything in the solution as one Using a BladeCenter E chassis up to 84 HS22 servers 168 processors can be installed in one industry standard 42U rack but the value of BladeCenter extends far beyond high density data center environments The various BladeCenter chassis are designed to monitor environmental conditions in the chassis and each blade and send alerts to the administrator Advanced standard features such as Active Memory Predictive Failure Analysis light path diagnostics hot swap redundant hard disk drives power supplies and blower modules with Calibrated Vectored Cooling IPMI 2 0 support including highly secure remote power control text console redirect over LAN next generation BIOS UEFI an Advanced Management Module upgradeable with a redundant AMM IBM Systems Director management software including IBM Systems Director Active Energy Manager for x86 Remote Deployment Manager and IBM ServerGuide h
20. ansion card slots supporting adapters of up to 25W apiece to an HS22 One BPES can be connected per HS22 blade for a total of 3 available slots 1 in the blade and 2 in the expansion unit Note The BPE3 reserves the high PCI b a speed CFFh expansion connector in the HS22 leaving only the CIOv slot available EXPHRESS Similarly the optional BladeCenter PCI Express Gen 2 Expansion Blade BPE4 adds 1 standard full height full length and 1 standard full height half length x16 physical x8 mechanical 8GBps PCle Gen 2 expansion card slot per HS22 blade These slots support two industry standard PCle adapters up to 75W per adapter The BladeCenter PCI Express Gen 2 Expansion Blade offers a unique stacking feature that allows clients to stack up to 4 expansion blades per HS22 blade offering up to an additional 8 PCle slots per HS22 blade Note Unlike the BPES the BPE4 does not reserve the high speed CFFh expansion connector in the HS22 leaving both slots available in the server If O slots are a greater need than processors or memory attaching multiple I O expansion units to one blade server is much more cost effective than installing multiple blade servers for the same number of adapter slots Note A maximum of one CFFh card is supported Common PCle adapters used to connect to BladeCenter switch modules include Fibre Channel additional Gigabit Ethernet cards 10Gb Ethernet Converged Network Adapters CNAs InfiniBand SAS etc
21. are imaging and operating systems personalization IBM offers extensive technical support by phone and via the Web Support options include links to forums newsgroups problem submission online shopping support service offerings device drivers for all IBM product lines software downloads and even upcoming technical seminar worldwide schedules and registration Also available are remote installation configuration and usage support for both System x hardware and software as well as onsite custom services to provide the level of expertise you require IBM Maintenance and Technical Support solutions can help you get the most out of your IT investment by reducing support costs increasing availability and simplifying management with integrated support for your multiproduct multivendor hardware and software environment For more information on hardware maintenance software support solution support and managed support visit http ibm com services maintenance IBM options for System x servers let you take your servers to a higher level You can rely on System x and blade options to supply a comprehensive solution for your business needs Options help create an optimized server system to meet your data protection storage and availability needs Every IBM option is designed and tested for peak performance and flexibility helping to maximize your return on investment The combination of System x servers and options lets you keep your fingers
22. ary e IBM System Storage TS3310 Modular Tape Library Light Path Diagnostics Light path diagnostics enables a technician to quickly identify and locate a failed or failing system component such as a specific blower module or memory DIMM This enables quick replacement of the component which helps increase server uptime and lower servicing costs The front of each blade server and the chassis itsel has an LED indicator light to show 7 According to internal IBM testing the typical maximum IOPS of a 600GB 15K 3 5 inch hot swap SAS HDD is 400 4K random reads while the typical IOPS of a 640GB High IOPS SSD PCle adapter is 200 000 or 500x The typical bandwidth of the same HDD 195MBps 64K sequential reads while the typical bandwidth of a 640GB High IOPS MLC adapter is 1 5GBps or 7 7x 97 014 IOPS 9W 10 779 IOPS per watt 160GB 320GB adapters 196 000 IOPS 12W 16 333 IOPS per watt 640GB adapters 400 IOPS 16 5W 24 IOPS per watt 600GB 15K 3 5 inch hot swap SAS HDD Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling possible component failures This lets the servicer identify the failing component without the need to or remove the blade server from the chassis The light path diagnostics panel tells the servicer which component of the affected server requires attention In addition many com
23. ate drives and access to terabytes of external IBM System Storage SAN and NAS storage devices 2 5 inch drives consume approximately half the power of 3 5 inch drives Two Gigabit Ethernet ports standard plus more using either a 2 port or 4 port Gigabit Ethernet Expansion Card or a BladeCenter PCI Express I O Expansion Unit In addition the various BladeCenter chassis offer a high degree of flexibility A 30mm HS22 blade server can be upgraded via a planned PCI Express I O Expansion Unit This expandability allows configurations that are 30mm or 60mm wide with a variety of I O options depending on need When installed in a BladeCenter H high speed switch bay the optional Multi Switch Interconnect Module doubles the number of Gigabit Ethernet and Fibre Channel connections to every blade in the chassis up to 8 or 12 ports depending on the blade server Xeon processor based HS22 blades can be used in the same chassis as Intel processor based HC10 HS12 HS20 HS21 HS21 XM HS40 and HX5 blades AMD Opteron processor based LS20 LS21 LS22 LS41 and LS42 blades IBM PowerPC processor based JS20 JS21 and JS22 blades POWER6 processor based JS12 JS23 and JS43 Express blades POWER7 processor based PS700 PS701 and PS702 blades Cell Broadband Engine processor based QS21 and IBM PowerXCell processor based QS22 blades Depending on the blade servers used the various BladeCenter chassis support Microsoft Windows Linux
24. ate of IMM firmware e Firmware firewall e Support for IPMI v2 0 compliant management software e g xCAT e Other mandatory and optional IPMI functions in the blade s IMM The IMM via the management module alerts IBM Systems Director to anomalous environmental factors such as voltage and thermal conditions even if the server has failed Other systems management features offered for the combination of blade server and chassis include e Predictive Failure Analysis for system processors memory and HDDs as well as chassis switch Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling modules blower modules and power modules e Web based out of band control e Windows blue screen capture Remote virtual media e High speed remote redirection of PCI video keyboard and mouse e SSL Secure Socket Layer and LDAP Lightweight Directory Access Protocol support In order to put control of processor power saving features at the fingertips of administrators IBM developed IBM Systems Director Active Energy Manager Active Energy Manager is designed to take advantage of new processor features such as balancing the performance of the system according to available power input It provides the ability to plan and predict power consumption based on your BladeCenter hardware configuration It also helps you reduce the infrastructure require
25. ations It also offers enhanced security because it runs without an operating system based console and is updated patched much like firmware Disk Controllers All HS22 models include an integrated LSI 1064E SAS SATA controller This controller supports up to two internal SAS or SATA HDDs or two internal solid state drives and offers hardware RAID 0 1 support 256MB of optional battery backed cache memory is available An optional ServeRAID MR10ie controller ClOv form factor adds RAID 5 50 6 60 support for direct attach BladeCenter S storage or external System Storage EXP3000 access along with 256MB of cache memory and battery backup For SAN storage use the optional IBM SAS Connectivity Card CIOv For iSCSI storage use an Ethernet Expansion Card ClOv For Fibre Channel SAN storage use an optional Fibre Channel Expansion Card ClOv The SAS controller provides data transfer speeds of up to 3Gbps per second in each direction full duplex across the SAS bus for an aggregate speed of 6Gbps The serial design of the SAS bus allows maximum performance to be maintained as additional drives are added Flexible Internal Storage The HS22 offers a choice of internal 2 5 inch storage up to two hot swap SAS or SATA drives or two hot swap solid state drives Data transfer rates depend on many factors and are often less than the maximum possible Please see the Legal Information section for important notices and information
26. ch modules including 4X InfiniBand and 10Gb Ethernet The various BladeCenter chassis use ultrahigh efficiency power supplies Many industry standard servers use power supplies that are only 70 80 efficient at converting power from AC wall current to the DC power used inside servers BladeCenter power modules are up to 9496 efficient and meet the 80 Plus Platinum Standard This helps save even more money as more of the power input you are paying for is used for processing rather than released into the data center as waste heat that requires even more energy to cool e BladeCenter also reduces the number of parts required to run the system Sharing fans Systems management floppy devices and media means fewer parts to buy and maintain and fewer items that can fail and bring the overall solution down Based on Intel measurements Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Flexibility The HS22 has the ability to grow with your application requirements thanks to Up to two multi core Xeon processors up to twelve cores per server A choice of processor speeds from 1 6 to 3 6GHz up to 12MB of shared cache and a choice of power draw from 40W to 130W A choice of memory speeds from 800MHz to 1333MHz Up to 192GB of system memory in 12 DIMM slots Two internal hot swap 2 5 inch SAS or SATA HDDs or solid st
27. d for redundancy by using fewer servers on smaller power feeds and potentially lowering your overall data center support costs It does this by inventorying all components at the blade level then adding up the power draw for each blade and tracking that usage In failure mode Active Energy Manager through the BladeCenter Management Module might request that certain blades in each domain throttle down to reduce power consumption Automatic Server Restart ASR helps reduce downtime by restarting the server automatically in the event of a system lockup ASR technology is a combination of hardware circuitry tied into the server s system reset function and a device driver As long as the server continues running the ASR watchdog timer will keep being reset but if the operating system crashes or the hardware freezes somehow the ASR software will be unable to reset the hardware timer If the timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Systems Director These features are designed so that no more than five minutes can pass before the server is restarted Text and Graphics Console Redirect support allows the administrator to remotely view HS22 text and graphics messages over serial or LAN Wake on LAN permits the server to be remotely powered on if it has been shut off Once powered up the server can be controlled across the network using the P
28. e IBM ServerProven IBM Standalone Solutions Configuration Tool IBM System x and BladeCenter Power Configurator IBM ServerGuide IBM Systems Director Service and Support Manager Product Customization Services and extensive technical support offerings The IBM ServerProven program provides the confidence that specific options and operating on Server systems have been tested on the blade servers and chassis and are officially supported to work Proven together It is updated frequently to keep the latest compatibility information at your fingertips The IBM Standalone Solutions Configuration Tool SSCT is a downloadable tool that simplifies the often complex chore of configuring a full rack of servers including blade servers and confirming that you have all the cables power distribution units KVM keyboard video and mouse switch boxes and other components you need as well as the proper airflow clearances electrical circuits and other environmental conditions IBM System x and BladeCenter Power Configurator helps IT managers plan for data center power needs by providing the following information for specific configurations of System x and BladeCenter systems power input watts PDU sizing amps heat output BTUs airflow requirements through chassis CFM VA rating leakage current mA and peak inrush current amps IBM ServerGuide installed from CD simplifies the process of installing and configuring System x servers ServerGuid
29. e avoided Note It is important to ensure that all three memory channels in each processor are populated The relative memory bandwidth decreases as the number of channels populated decreases This is because the bandwidth of all the memory channels is utilized to support the capability of the processor So as the channels are decreased the burden to support the requisite bandwidth is increased on the remaining channels causing them to become a bottleneck For peak performance Always populate both processors with equal amounts of memory to ensure a balanced NUMA system Always populate all 3 memory channels on each processor with equal memory capacity Ensure an even number of ranks are populated per channel a Use dual rank DIMMs whenever appropriate For optimal 1333MHz performance populate 12 dual rank DIMMs 6 per processor for processsors that support 2 DIMMs per Channel 2DPC g For optimal 1066MHz performance populate 12 dual rank DIMMs 6 per processor a For optimal 800MHz performance with high DIMM counts populate 12 dual rank or quad rank DIMMs 6 per processor and clock memory down to 800MHz in BIOS With the above rules it is not possible to have a performance optimized system with 4GB 8GB 16GB or 128GB With 3 memory channels and interleaving rules configure systems with 6GB 12GB 18GB 24GB 48GB 72GB 96GB etc for optimized performance Please see the Legal Information section for importan
30. e goes beyond mere hardware configuration by assisting with the automated installation of the Microsoft Windows Server 2000 and 2003 operating systems device drivers and other system components with minimal user intervention Drivers are also included for support of Novell NetWare Red Hat Linux and SUSE LINUX This focus on deployment helps to reduce both your total cost of ownership and the complexity that administrators and technical personnel face IBM Systems Director Service and Support Manager previously called IBM Electronic Service Agent is an innovative call home feature that allows System x and BladeCenter servers to automatically report hardware problems to IBM support which can even dispatch onsite service if necessary to those customers entitled to onsite support under the terms of their warranty or an IBM Maintenance Agreement Service and Support Manager resides on a server and provides electronic support and problem management capabilities through a highly secure electronic dialogue between your systems and IBM It monitors networked servers for hardware errors and it can perform hardware and software inventories and report inventory changes to IBM All information sent to IBM is stored in a highly secure database and used for improved problem determination Additional services include hardware warranty upgrades and factory installed Product Customization Services PCS such as asset tagging hardware integration softw
31. eed for redundant drives e PMI 2 0 supports highly secure remote system power on off using data encryption This allows an administrator to restart a server without having to visit it in person saving travel time and getting the Server back up and running quickly and securely Environmentally tuned blower modules in the chassis adjust to compensate for changing thermal characteristics At the lower speeds they draw less power and suffer less wear Equally important in a crowded data center temperature controlled blowers produce less ambient noise in the data center than if they were constantly running at full speed Textand graphics console redirection support allows the administrator to remotely view HS22 text and graphic messages over serial or LAN connections e A standard three year parts and labor limited onsite warranty affords you peace of mind and greater potential investment protection Right Open Easy Green You need to make IT decisions that will drive business success You face management challenges and technological complexity such as space constraints power and cooling limitations heterogeneous environments and I O connectivity issues IBM brings together the widest choice of compatible chassis blade servers storage and networking offerings and solution providers in the industry to help you build an open and flexible IT environment And regardless of the size of your business you want to be up and running 24 7
32. ell as support for direct attach BladeCenter S storage or external System Storage expansion units External Storage The IBM System Storage DS3000 DS4000 DS5000 and DS8000 series as well as the System Storage N3000 N5000 N6000 and N7000 series comprise a powerful and broad shared storage family with integrated management software designed to meet midrange and enterprise needs For lower end needs IBM offers the System Storage EXP810 and EXP3000 storage expansion units Additionally external LAN attached tape storage is available Communication Modules The various BladeCenter chassis support integrated communication and I O switches and or bridges for Gigabit and 10Gb Ethernet Myricom 4Gb and 8Gb Fibre Channel 1X and 4X InfiniBand iSCSI 3Gb SAS and others Expansion adapters for individual HS22 blades are available to interface with these modules The BladeCenter H and BladeCenter HT also support the Multi Switch Interconnect Module which doubles the number of Gigabit Ethernet and Fibre Channel connections available to all blades in the chassis Rear Door Heat eXchanger The unit attaches to the back of an IBM S2 42U Enterprise Rack It is capable of removing up to 50 000 BTUs 14KVa from the data center using water lines under the raised floor The door swings open for servicing 3 15 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for
33. elp maintain system availability with increased uptime If you need highly manageable high performance computing power in a space or power constrained environment the HS22 is the ideal system Selling Features Price Performance e There is an HS22 model to fit all budgets The HS22 offers a choice of high performance 6 core 4 core 2 core Xeon processors with integrated memory controllers clock rates from 1 6GHz to 3 6GHz and from 3MB to 12MB of shared cache processor specific of integrated L3 cache Xeon 5600 series processors offer up to 60 better performance than the previous generation 5500 Series processors and up to 150096 better performance than the single core processors of a few years ago that you may still be using Low voltage processors draw less energy and produce less waste heat than higher voltage processors thus helping to reduce data center energy costs On a per core basis the standard 80W processors are extremely economical consuming as little as 13 33W per core Some low voltage Xeon processors consume only 10W per core 4 core 40W or 6 core 60W e Upto 192GB of registered DDR3 ECC memory operates at 800MHz to 1333MHz depending on the system configuration for high performance and wide memory bandwidth e Runtwo DIMMs per memory channel at 1333MHz in specific 5600 series processor configurations Embedded virtualization optional on all models offers extremely high performance enhanced Security and
34. eneration 5400 series processors That can result in faster processing of latency sensitive workloads This new processor design comes with some trade offs in memory capacity performance and cost For example more lower cost lower capacity DIMMs mean lower memory speed Alternatively fewer higher capacity DIMMs cost more but offer higher performance Regardless of memory speed the Xeon 5500 platform represents a significant improvement in Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling memory bandwidth over the previous Xeon 5400 platform At 1333MHz the improvement is almost 50096 over the previous generation This huge improvement is mainly due to the dual integrated memory controllers and faster DDR3 1333MHz memory Throughput at 800MHz is 25 gigabytes per second GBps at 1066MHz it s 32GBps and at 1333MHz it s 35GBps This improvement translates into improved application performance and scalability Memory interleaving refers to how physical memory is interleaved across the physical DIMMs A balanced system provides the best interleaving A Xeon 5500 processor based system is balanced when all memory channels on a socket have the same amount of memory In the case of HS22 which has a balanced DIMM layout it is easy to balance the system for all three memory frequencies The recommended DIMM population is shown below a
35. ent Module Q IPMI 2 0 compliance including highly secure remote power control Q cKVM Q IBM Systems Director Active Energy Manager m IBM Service and Support Manager Q Advanced management capabilities e Interface to one or two Advanced Management Modules in the chassis for advanced systems management capability Q Serial over LAN Q Supports LDAP and SSL industry standards Textand graphics console redirection systems management Optional solid state drive as a high reliability alternative to internal storage with up to three times the MTBF of spinning disk drives Numerous hot swap redundant capabilities provided via the chassis Server Comparison Chart The following table shows the suggested uses for the respective IBM BladeCenter blade servers including comparisons of the uses for which each server is best suited Theme Key Workloads Awtigereos Web 2 0 Web 3D Cluster HPC Modeling amp Simulation High Performance DB Business Intelligence Search Content Important E n Fig 2 on v o e oo D T w 38 32 35 8 ES ae ezcioolez a DG i we 5 z0 ae O gt Be les ie e E eig y gm o D RAE SESI amp za tor ee o a EP m eo NS Nice to Have Requirements Can do without Ayunoasg juawAojdeq peinquisiq e Best wp Better BladeCenter Servers O aoa OOQ2 sH Odaztsr QOO Sd m Communities Comme
36. es with RAID protection Hot swap redundant power supply modules f f 11 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Hot swap redundant cooling fan blower modules e Hot swap redundant switch modules e Redundant midplane connectors between blades and modules Energy Smart Features IBM servers work hard to keep your energy bills low from high efficiency power supplies and fans to lower draw processors and memory Technologies such as these along with the Xeon 5500 5600 series processors that intelligently adjust their voltage and frequency help take costs out of IT e 40W 4 core processors use 50 less energy than 80W processors and 69 less than 130W processors e 60W 6 core processors use 37 less energy than 95W processors and 54 less than 130W processors e 1 5V DDR3 DIMMs consume 10 15 less energy than 1 8V DDR2 DIMMs used in older servers 1 35V DDR3 DIMMs consume up to 19 less energy than 1 5V DDR3 DIMMs e Solid State Drives consume up to 80 less energy than 2 5 inch HDDs and up to 88 less than 3 5 inch HDDs e Operating at as much as 94 efficiency high efficiency power supplies use less energy than competitive power supplies that average only 70 80 efficiency and produce less waste heat that needs to be cooled Dynamic fan speeds In the event of a fan failure the other
37. ese links merely as a convenience and the inclusion of such links does not imply an endorsement Information in this presentation concerning non IBM products was obtained from the suppliers of these products published announcement material or other publicly available sources IBM has not tested these products and cannot confirm the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products Some machines are designed with a power management capability to provide customers with the maximum uptime possible for their systems In extended thermal conditions rather than shutdown completely or fail these machines automatically reduce the processor frequency to maintain acceptable thermal levels MB GB and TB 1 000 000 1 000 000 000 and 1 000 000 000 000 bytes respectively when referring to storage capacity Accessible capacity is less up to 3GB is used in service partition Actual storage capacity will vary based upon many factors and may be less than stated Performance is in Internal Throughput Rate ITR ratio based on measurements and projections using standard IBM benchmarks in a controlled environment The actual throughput that any user will experience will depend on considerations such as the amount of multiprogramming in the user s job stream the I O configuration the storage configuration and
38. ess 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 60W 6 core Xeon 5600 series low voltage model L5630 running at 2 0GHz with low power draw and amazing performance watt only 10W per core 5 86GTps QPI speed 12MB of L3 processor cache and 1066MHz memory access supported in all BladeCenter chassis except BladeCenter T e 80W 4 core Xeon 5600 series model E5606 running at 2 13GHz with reduced power draw and impressive performance watt 20W per core 4 8GTps QPI speed 8MB of L3 processor cache and 1066MHz memory access supported in all BladeCenter chassis except BladeCenter T Also available via special bid e 40W 4 core Xeon 5600 series low voltage model L5618 running at 1 86GHz with extremely low power draw and amazing performance watt only 10W per core 5 86GTps QPI speed 12MB of L3 processor cache and 1066MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T Note Because of the integrated memory controllers the former front side bus FSB no longer exists With the Xeon 5500 series and 5600 series processors Intel has diverged from its traditional Symmetric Multiprocessing SMP architecture to a Non Uniform Memory Access NUMA architecture The Xeon 5500 and Xeon 5600 processors are connected through a serial coherency link called QuickPath Interconnect QPI QPI is capable of 6
39. f video text keyboard and mouse Integrated industry standard Unified Extensible Firmware Interface UEFI next generation BIOS New capabilities include Q Human readable event logs no more beep codes Q Complete setup solution by allowing adapter configuration function to be moved into UEFI Q Complete out of band coverage by the Advance Settings Utility to simplify remote setup Integrated industry standard IPMI 2 0 support works with the IMM to alert IBM Systems Director to anomalous environmental factors such as voltage and thermal conditions It also supports highly secure remote power control Integrated Trusted Platform Module TPM 1 2 support IBM Systems Director Active Energy Manager an IBM exclusive is designed to take advantage of new system power management features by monitoring actual power usage and providing power consumption capping features More accurate power usage data helps with data Some older chassis may require power module and management module upgrades But the chassis itself as well as fan blower modules and other components are fully compatible Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling center construction planning and the sizing of power and cooling needs as well as allowing you to use available power more efficiently The HS22 supports remote presence concurrent KVM cKV
40. fans will run faster to compensate until the failing fan is replaced Competitive fans must run faster at all times just in case wasting power Advanced Systems Management Capabilities Each BladeCenter chassis offers a high level of systems management capabilities that are well suited to remote locations as well as to stand alone environments Features include the Advanced Management Module AMM Integrated Management Module IMM Automatic Server Restart Systems Director Active Energy Manager for x86 Wake on LAN support PXE 2 0 support text and graphics console redirect Predictive Failure Analysis Embedded Dynamic System Analysis and IBM Systems Director The chassis based AMM in combination with the HS22 blade server s IMM provides industry standard Intelligent Platform Management Interface IPMI 2 0 compliant systems management The AMM provides a number of important system functions including Monitoring of system and battery voltage system temperature fans power supplies processor and DIMM status e Fan speed control e Product ID and Family ID detection e Highly secure remote power on off e System reset control e NMI SMI detection and generation e System diagnostic LED control power HDD activity alerts heartbeat e IPMI over LAN e Serial Over LAN e Proxy server support LAN messaging and alerting e VLAN support e Enhanced authentication and encryption algorithms RMCP SHA 1 AES e Local upd
41. g on the type of memory population of memory and processor model the memory may be clocked at 1333MHz 1066MHz or 800MHz Xeon 5600 5500 Xeon 5600 5500 Processor 0 Processor 1 Memory Controller Memory Controller Note If only one processor is installed only the first six DIMM slots can be used Adding a second processor not only doubles the amount of memory available for use but also doubles the number of memory controllers thus doubling the system memory bandwidth If you add a second processor but no additional memory for the second processor the second processor has to access the memory from the first processor remotely resulting in longer latencies and lower performance The latency to access remote memory is almost 75 higher than local memory access So the goal should be to always populate both processors with memory The 1333MHz E56xx L5640 and X56xx processor models support up to 1333MHz memory clock speed and 2 DIMMs per channel 2DPC at 1333MHz with single rank and dual rank RDIMMs and UDIMMs running at 1 5V Other 5600 series processors access memory at 1066MHz The E550x models support memory at 800MHz only Running memory at 1333MHz where supported versus 1066MHz offers up to 996 better performance while running memory at 1066MHz produces up to 2896 better performance than memory running at 800MHz Xeon 5500 and 5600 series processors access memory with almost 5096 lower latency than the previous g
42. igh IOPS MS Class SSD PCle Adapter and the 320GB High IOPS SD Class SSD PCle Adapter as well as the 640GB High IOPS MLC Duo Adapter These adapters offer near DRAM performance with extremely high data retention up to 25 years and RAID grade data protection with 160GB or 320GB capacities ServeRAID Controllers System x servers using ServeRAID technology allow organizations to build a reliable foundation for business critical computing IBM ServeRAID technology allows an array consisting of multiple physical hard disk drives to be treated as one logical drive ServeRAID technology also allows data to be stored redundantly across multiple hard disk drives enhancing both the integrity and the availability of the data SAS and SATA ServeRAID controllers offer enhanced performance due to onboard processors and cache Because IBM ServeRAID controllers can help significantly improve data transfer rates this technology is extremely effective when implementing demanding transaction oriented applications By employing the advanced fault tolerance of IBM ServeRAID technology companies can effectively implement networked business systems that require large amounts of storage space for data and applications that must be available for their businesses to continue operating The optional ServeRAID MR10ie controller CIOv form factor with up to 6Gbps throughput per SAS port adds RAID 5 50 6 60 support and 256MB of cache memory and battery backup as w
43. me with integrated failover capability Manage from a single point of control via the Advanced Management Module Use with virtually all IBM switches blades and chassis GREEN today for a better tomorrow e It offers control via powerful tools that help you optimize your data center infrastructure so you can be responsive Understand your power requirements with IBM Power Configurator Monitor control and virtualize your power with IBM Systems Director Active Energy Manager Reduce data center hot spots with the IBM Rear Door Heat eXchanger Optimize and future proof your data center with IBM Data Center Energy Efficiency services e Our eco friendly servers and services can help you be environmentally responsible Become more energy efficient with IBM expertise Key Features Multicore Intel Xeon Processors The HS22 supports up to two identical Xeon 5600 series or 5500 series processors Each processor contains a memory controller meaning two in a two processor system for superior performance Some processor models are available via CTO only The choice of processors includes e 130W 6 core Xeon 5600 series models X5690 or X5680 running at 3 46 or 3 33GHz respectively with impressive performance watt 21 67W per core 6 4GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 130W 4 c
44. n completely or fail the HS22 automatically reduces the processor frequency to maintain acceptable thermal and power levels All HS22 models offer impressive features at an equally impressive price including up to two hot swap SAS or SATA hard disk drives or two hot swap solid state drives with RAID 0 1 1E support and one USB based internal flash drive for embedded hypervisor Additional storage is available via the BladeCenter S chassis Moreover the HS22 is optimized for diskless operation offering each blade server access to essentially unlimited external storage capacity via Fibre Channel SAS or iSCSI A single BladeCenter E or BladeCenter H chassis supports up to 14 hot swappable 30mm wide HS22 blades in only 7U BladeCenter E or 9U BladeCenter H of rack space or up to 12 in the 12U BladeCenter HT high speed telecommunications chassis In addition to the blade servers these chassis also hold up to 4 switches BladeCenter E or up to 10 BladeCenter H or 8 switches bridges BladeCenter HT internally The BladeCenter S designed for SMB and mid market customers takes integration and affordability to a new level combining up to 12 hot swap SAS SATA HDDs with optional SAS card and up to 6 blade servers and 4 switches Not only can this save significant data center space and therefore the cost of floor space and rack hardware compared to 1U servers it also consolidates switches bridges and cables for reduced complexity and lower c
45. ned with up to 12MB of shared cache and leading edge memory performance up to 1333MHz depending on processor model to help provide the computing power you require to match your business needs and growth The HS22 supports up to 192GB of registered double data rate III DDR3 ECC Error Checking and Correcting memory in 12 DIMM slots with optional Chipkill protection for high performance and reliability Selected models are planned for NEBS 3 ETSI compliance The HS22 offers an option for VMware vSphere Hypervisor formerly ESXi preloaded on a standard USB flash drive It operates in a diskless configuration offers a smaller memory footprint extremely high performance and stronger security making getting a system up and running in a virtualized environment faster and easier than ever before An integrated dual port Gigabit Ethernet controller is standard providing high speed data transfers and offering TOE TCP Offload Engine support load balancing and failover capabilities Via optional expansion cards each blade can also connect to additional Ethernet SAS Fibre Channel iSCSI InfiniBand and other high speed communication switches housed in the chassis Optional 2 port and 4 port Expansion Cards add additional fabrics to the HS22 server as needed This blade is designed with power management capability to provide the maximum uptime possible for your systems In extended thermal conditions or power brownouts rather than shut dow
46. nts from all collected logs The information is collected into a file that you can send to IBM service and support Additionally you can view the information locally through a generated text report file or you can copy the log to removable media and view the log from a Web browser IBM Systems Director software for advanced workgroup management is included with the server IBM Systems Director comes with a portfolio of tools including Active Energy Manager Service and Support Manager and other tools System Availability a no charge download and Capacity Manager sold separately are available as add ons for additional server management and increased availability IBM Systems Director provides a single uniform graphical interface for all of these systems management functions IBM Systems Director enables you to customize thresholds and monitor system components for things like temperature voltage regulation etc to help maximize uptime 3 13 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Extensive System Support Features The IBM services and technical support portfolio provides world class consistent high quality service and support From the start IBM programs make it easier for you to plan for configure and purchase BladeCenter servers get them running and keep them running long term These features includ
47. on the pulse of your e business Key Options Processors The Intel Xeon processor provides high clock rates 64 bit extensions a large cache Hyper Threading Technology Turbo Boost Technology energy saving features and For onsite labor IBM will attempt to diagnose and resolve the problem remotely before sending a technician 14 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling advanced features for availability and manageability Large cache size and multiple cores combined with a 1066MHz or 1333MHz memory access speed reduce memory latency and facilitate the movement of data through the processor and I O devices Note System performance depends not only on the number of processors in the server but also on the power and functionality of each processor as well as the number capacity and arrangement of the DIMMs Adding a second processor may be a cost effective way to achieve significant performance improvements Memory Memory is a significant factor in systems application performance Adding more memory to a BladeCenter server is one of the most effective ways to increase application performance For best performance in a server with a quad core processor there should be twice as much memory available as for a dual core processor Note Fewer large capacity DIMMs may provide better performance and
48. ore Xeon 5600 series model X5677 running at 3 46GHz with impressive performance 32 5W per core 6 4GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 95W six core Xeon 5600 series models X5675 or X5670 running at 3 06 or 2 93GHz respectively with impressive performance watt 15 84W per core 6 4GTps QPI speed 12MB of shared L3 cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 95W 4 core Xeon 5600 series model X5672 running at 3 2GHz with reduced power draw and excellent performance watt only 23 75W per core 6 4GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology and Hyper Threading Technology supported in all BladeCenter chassis except BladeCenter T e 95W four core Xeon 5600 series model X5667 running at 3 06GHz with excellent performance watt 23 75W per core 6 4GTps QPI speed 12MB of shared L3 cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology supported in all BladeCenter chassis except BladeCenter T e 80W 6 core Xeon 5600 series model E5649 running at 2 53GHz with reduced power draw and impressive performance watt only 13 33W per core 5 86GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2
49. performance energy and cooling Redundant features Optional hot swap drives power supply modules blower modules management modules switches and bridges provide redundancy for the various BladeCenter chassis HS22 Images Front View Light Path Diagnostic Panel Interior View USB Flash ae VO Adapter BladeCenter HS22 Specifications 7870 Axx Bxx Cxx Dxx Fxx Gxx Hxx Nxx plus CTO and special bid 30mm blade Six core Xeon Four core Xeon Two core Xeon E56xx L56xx X56xx E56xx L56xx X56xx E55xx 2 0GHz L5630 CTO 1 6GHz E5603 A5x 2 00GHz E5503 D3x Processor type 16 Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Processor power draw Internal cache QuickPath Interconnect QPI speed gigatransfers per second Maximum memory access speed of processors standard BladeCenter HS22 Specifications 2 26GHz L5640 N2x 2 4GHz E5645 CTO 2 53GHz E5649 B6x 2 66GHz X5650 H2x HAx 2 93GHz X5670 H4x 3 06GHz x5675 C6x 3 33GHz X5680 F2x 3 46GHz X5677 F3x 3 46GHz X5690 C8x 130W B5x C7x C8x F2x F3x 95W C5x C6x H2x HAx H5x HAx 1 86GHz L5609 CTO 1 86GHz L5618 spec bid 2 13GHz E5606 CTO 2 26GHz E5607 A7x 2 40GHz E5620 G2x 2 66GHz E5640 G4x 2 93GHz X5647 B5x 3 06GHz X5667 H5x 3 2GHz X5672 C5x 3
50. ponents have their own identifying LEDs For example each of the memory modules has an LED next to the socket as do both processors This allows the servicer to easily identify exactly which component needs servicing By following the light path the component can be replaced quickly and without guesswork Note In the event of a failed DIMM the system will restart and mark the DIMM as bad while offline thus allowing the system to continue running with reduced memory capacity until serviced Gigabit Ethernet Controllers The HS22 includes a dual port integrated Broadcom BCM57098S Gigabit Ethernet controller for up to 10X higher maximum throughput than a 10 100 Ethernet controller The controller offers TOE TCP Offload Engine support as well as failover and load balancing for better throughput and system availability It also supports highly secure remote power management using IPMI 2 0 plus Wake on LAN and PXE Preboot Execution Environment Flash interface For additional Gigabit Ethernet controllers an optional 2 port or 4 port Ethernet expansion card adds additional Gigabit Ethernet ports High Performance Adapter Slots The HS22 blade server includes two x8 PCle adapter slots They support CFF compact form factor cards one standard speed ClOv and one high speed CFFh The BladeCenter PCI Express I O Expansion Unit 3 BPE3 adds 2 standard full height full length x16 physical x8 electrical AGBps PCle Gen 1 exp
51. rce Collaboration ERP SCM CRM O O O Q v O v OO 4 4 04 OQJOOOOOO Oeeoe0e0o0o0c Infrastructure Applications Business Hosted Client Applications Point of Sale Branch Office Virtualization Business Continuity Database Email Collaboration Security Web Serving File amp Print OOO Seed OQOOO 9Oc c OOO ee 12 The PCle expansion units each require an adjacent blade slot Please see the Legal Information section for important notices and information 20 Versatile easy to use blade optimized for performance energy and cooling For More Information IBM BladeCenter Servers and Options IBM Systems Director Service and Support Manager IBM System x and BladeCenter Power Configurator IBM Standalone Solutions Configuration Tool IBM Configuration and Options Guide IBM ServerProven Program Technical Support Other Technical Support Resources Legal Information IBM Corporation 2010 IBM Systems and Technology Group Dept U2SA 3039 Cornwallis Road Research Triangle Park NC 27709 Produced in the USA February 2011 All rights reserved For a copy of applicable product warranties write to Warranty Information P O Box 12195 RTP NC 27709 Attn Dept JDJA B203 IBM makes no representation or warranty regarding third pa
52. reboot Execution Environment PXE Like Wake on LAN PXE is system firmware It allows software such as the IBM Remote Deployment Manager to take control of a system before the BIOS operating system or applications are loaded using Wake on LAN PXE and lets an administrator perform many low level tasks remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Predictive Failure Analysis PFA enables the MM AMM and the IMM to detect impending failure of supported components processors memory expansion cards switch blower and power supplies and hard disk drives before actual failure and alert the administrator through IBM Systems Director This gives you the ability to replace the failing component before it fails resulting in increased uptime Embedded Dynamic System Analysis DSA feature collects and analyzes system information to aid in diagnosing problems The diagnostic programs collect the following information e System configuration Network interfaces and settings Installed hardware e Service processor status and configuration e X Vital product data firmware and BIOS configuration Hard disk drive health RAID controller configuration e Event logs for ServeRAID controllers and service processors The diagnostic programs create a merged log that includes eve
53. rty products or services including those designated as ServerProven or ClusterProven Telephone support may be subject to additional charges For onsite labor IBM will attempt to diagnose and resolve the problem remotely before sending a technician IBM the IBM logo ibm com Active Energy Manager AIX BladeCenter Calibrated Vectored Cooling POWER6 System Storage ServeRAID System x Wake on LAN and X Architecture are trademarks of IBM Corporation in the United States other countries or both If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol e or these symbols indicate U S registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http ibm com legal copytrade shtml 80 PLUS and the 80 PLUS logo are registered trademarks of Eco Consulting Cell Broadband Engine is a trademark of Sony Computer Entertainment Inc in the United States other countries or both and is used under license therefrom InfiniBand is a trademark of the InfiniBand Trade Association Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a registered trademark of Linus Torvalds Microsoft Windows and the
54. ssuming DIMMs with identical capacities Memory DIMMs per Max Memory 5600 Series 5500 Series Frequency Channel Capacity 2 X5650 L5640 1333MHz 12 DIMMs 192GB E5645 and N A above 2 1066MHz 12 DIMMs 192GB All N A 2 800MHz 12 DIMMs 192GB N A E5503 E5507 800MHz 2 96GB 1333MHz All processors All processors Mirroring 12 DIMMs available A memory rank is simply a segment of memory that is addressed by a specific address bit DIMMs typically have 1 2 or 4 memory ranks as indicated by their size designation A typical memory DIMM description is 2GB 2Rx8 DIMM The 4R designator is the rank count for this particular DIMM R for rank 2 The x8 designator is the data width of the rank It is important to ensure that DIMMs with appropriate number of ranks are populated in each channel for optimal performance Whenever possible it is recommended to use dual rank DIMMs in the system Dual rank DIMMs offer better interleaving and hence better performance than single rank DIMMs For instance a system populated with six 2GB dual rank DIMMs outperforms a system populated with six 2GB single rank DIMMs by 7 for SPECjbb2005 Dual rank DIMMs are also better than quad rank DIMMs because quad rank DIMMs will cause the memory speed to be down clocked Another important guideline is to populate equivalent ranks per channel For instance mixing one single rank DIMM and one dual rank DIMM in a channel should b
55. t notices and information Versatile easy to use blade optimized for performance energy and cooling Power guidelines n Fewer larger DIMMs for example 6 x 4GB DIMMs vs 12 x 2GB DIMMs will generally have lower power requirements x8 DIMMs x8 data width of rank will generally draw less power than equivalently sized x4 DIMMs Reliability guidelines Using fewer larger DIMMs for example 6 x 4 GB DIMMs vs 12 x 2GB DIMMs is generally more reliable Xeon 5500 and 5600 series memory controllers support IBM Chipkill memory protection technology with x4 DIMMs x4 data width of rank but not with x8 DIMMs For increased availability the HS22 offers two additional levels of IBM Active Memory protection memory mirroring and memory sparing Memory mirroring works much like disk mirroring The total memory is divided into two channels Data is written concurrently to both channels The third channel is unused If a DIMM fails in one of the DIMMs in the primary channel it is instantly disabled and the mirrored backup memory in the other channel becomes active primary until the failing DIMM is replaced With mirroring enabled one third of total memory 4 DIMMs is available for use Note Due to the double writes to memory performance is affected Mirroring is handled at the hardware level no operating system support is required In memory sparing one of the three memory channels Ch2 for each processor is reserved as
56. ter IBM attempts to resolve the problem remotely International warranty service is available in any country in which this product is sold Please see the Legal Information section for important notices and information Versatile easy to use blade optimized for performance energy and cooling Match your data center needs and the appropriate interconnect using a common management point and 5 I O fabrics to choose from Extract the most from your third party management solutions by utilizing the BladeCenter Open Fabric Manager e Its collaborative enabling you to harness the power of the industry to deliver innovation that matters Get flexibility from a myriad of solutions created by Blade org members and industry leaders that have downloaded our open specification EASY to deploy integrate and manage e It enables efficient integrated management which allows you to minimize costs with the tools you need for effective management Automate OS installation and BIOS updates remotely with IBM Systems Director tools Administer your blades at the chassis or rack level with the Advanced Management Module Pluginto your enterprise management software t enable deployment simplicity without tradeoffs by speeding the deployment of new hardware in minutes rather than days using BladeCenter Open Fabric Manager Get significantly faster deployment of servers and I O than from rack solutions Reduce costly downti
57. the workload processed Therefore no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here Maximum internal hard disk and memory capacities may require the replacement of any standard hard drives and or memory and the population of all hard disk bays and memory slots with the largest currently supported drives available When referring to variable speed CD ROMs CD Rs CD RWs and DVDs actual playback speed will vary and is often less than the maximum possible BLO03029 USEN 07 21 Please see the Legal Information section for important notices and information
58. tionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system Intel s Virtualization Technology VT integrates hardware level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads DDR3 Registered Memory with Chipkill ECC Protection The HS22 uses registered double data rate IIl DDR3 VLP very low profile DIMMs and provides Active Memory features including advanced Chipkill memory protection for up to 16X better error correction than standard ECC memory In addition to offering triple the memory bandwidth of registered or fully buffered DDR2 memory DDR3 memory also uses less energy 1 8V DDR2 memory already offered up to 37 lower energy use than fully buffered memory Now a generation later 1 5V DDR3 memory is even more efficient using 10 15 less energy than DDR2 memory For even greater efficiency the HS22 also supports 1 35V DDR3 memory which uses up to 19 less energy than 1 5V DDR3 DIMMs The HS22 supports up to 192GB of memory in twelve DIMM slots Redesign in the architecture of the 5500 and 5600 series processors bring radical changes in the way memory works in these servers For example the Xeon 5500 and 5600 series processors integrate the memory controller inside the processor resulting in two memory controllers in a two socket system Each memory controller has three memory channels Dependin
59. use less energy than more lower capacity DIMMs I O Expansion Units A choice of BladeCenter PCI Express Expansion Unit 3 BPE3 or BladeCenter PCI Express Gen 2 Expansion Blade BPE4 offers from 3 to 10 total adapter slots per HS22 server to support additional fabrics including Ethernet 10Gb Ethernet Fibre Channel SAS and Converged Network Adapters and high performance graphics processing units GPUs Hard Disk Drives IBM hard disk drives help you improve the transaction and cost performance of your HS22 servers The choice of hard disk drives can be a critical aspect of maximizing the I O throughput of the system Hot swap SAS hard disk drives 2 5 inch are available for the HS22 with capacities up to 300GB at 10 000 RPMs or up to 146 8GB at 15 000 RPMs Hot swap SATA hard disk drives 2 5 inch are available for the HS22 with capacities up to 300GB at 10K RPMs Additional direct attach storage is available via the BladeCenter S chassis Solid State Drives IBM offers a 50GB 2 5 inch solid state drive as an alternative to internal HDDs It can be used as a highly available boot drive or for storing disk images or for other primarily read only uses High IOPS SSD PCIe Adapters For storage media offering up to 500 times the I O operations per second IOPS and up to 7 7 times the bandwidth of 15 000 RPM HDDs IBM offers the 160GB High IOPS SS Class SSD PCle Adapter the 320GB High IOPS SS Class SSD PCle Adapter the 320GB H
Download Pdf Manuals
Related Search
Related Contents
Samsung SUB-2GWW User Manual Honeywell BH-777TFE LP-R550USB-WA 取扱説明書 - 表示切替 TRACE GC Ultra - Thermo Scientific PLレポート 2010年度 No.4 Altronix MAXIMAL11 power distribution unit PDU TC Installations TCMBK101 mounting kit InstallatIon · Manual 5.0635.09.52 V2.1 1/2 Q-Band - Mobile Action Copyright © All rights reserved.