1. tional support Continue to pull the UPS out of the rack while a second person supports the rear underside 7 TROUBLESHOOTING Use the chart below to solve minor UPS installation problems Also refer to the APC web site Con tact APC for assistance with complex UPS problems PROBLEM AND POSSIBLE CAUSE SOLUTION UPS WILL NOT TURN ON ON button not pushed Press the ON button once to power the UPS and the load UPS not connected to AC power Check that the power cable from the UPS to the utility power supply supply is securely connected UPS input circuit breaker tripped Reduce the load on the UPS by unplugging equipment and re setting the circuit breaker on the back of UPS by pressing the plunger in Very low or no utility voltage Check the AC power supply to the UPS by plugging in a table lamp If the light is very dim have the utility voltage checked Rear Connector Plug not engaged Check the back of the unit to verify that the Rear Connector Plug is fully engaged Battery not connected properly Check that both battery connectors are fully engaged Internal UPS fault Do not attempt to use the UPS Unplug the UPS and have it serviced immediately UPS OPERATES ON BATTERY ALTHOUGH NORMAL LINE VOLTAGE EXISTS UPS input circuit breaker tripped Reduce the load on the UPS by unplugging equipment and re setting the circuit breaker on the back of UPS by pressing the plunger in Very high low or distorted line Move the
2. The UPS filters out small utility line fluctuations and isolates your equipment from large disturbances by internally dis connecting from the utility line The UPS provides continuous power from its internal batteries until the utility line returns to safe levels The Smart UPS has the power control and operating indicators located on the front panel The rear panel has the input and output connectors SMART UPS FRONT PANEL The ON and OFF buttons are used to power the UPS and act as master controls for the connected equipment Make sure connected loads are switched to their ON position The UPS remains on as long as it 1s attached to utility power OPERATION and connected equipment The equipment is immediately powered and the UPS performs a self test The charger maintains battery charge when the UPS is plugged in and Power On Press and release the button labeled TEST to supply power to the UPS utility voltage is present Power Off X Press and release the button labeled 0 to turn off power to the UPS and connected equipment O 85 Load The five LED display on the left of the front panel shows the percentage 0 67 of available power used by the connected equipment load For example 50 if three LEDs are lit the connected load is drawing between 50 and 67 O 33 of the UPS capacity If all five LEDs are lit the connected load is drawing 0 17 between 85 and 100 of capacity Thoroughly test your entire syst
3. APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care ELECTRICAL SAFETY m To reduce the risk of fire connect only to a circuit provided with a 30 Amp maximum branch circuit overcurrent protection in accordance with the National Electrical Code ANSI NFPA or country specific electrical code m Do not work alone under hazardous conditions m Check that the power cord s plug s and sockets are in good condition m To reduce the risk of electric shock when grounding disconnect the equipment from the AC power outlet before installing or connecting to other equipment Reconnect the power cord only after all connections are made m Useone hand whenever possible to connect or disconnect signal cables to avoid a possible shock from touching two surfaces with different electrical grounds m Connect the equipment to a three wire AC outlet two poles plus ground The receptacle must be connected to appropriate branch circuit mains protection fuse or circuit breaker Connection to any other type of receptacle may result in a shock hazard m Inorder to maintain compliance with the EMC directive output cords attached to the UPS should not exceed 10 meters in length DEENERGIZING SAFETY m Ifthe equipment has an internal energy source battery the output may be energized when the uni
4. UPS to a different outlet on a different circuit Test voltage Inexpensive fuel powered the input voltage with the utility voltage display If acceptable to generators can distort the voltage the connected equipment reduce the UPS sensitivity Normal UPS operation None The UPS is protecting the load connected equipment The UPS battery is weak due to a Charge the battery Batteries require recharging after extended recent outage or is near the end of its outages They wear faster when put into service often or when service life operated at elevated temperatures If the battery is near the end of its service life consider replacing the battery even if the re place battery LED indicator is not yet lit The UPS is overloaded Check the UPS load display Unplug unnecessary equipment such as printers FRONT PANEL INDICATORS FLASH SEQUENTIALLY The UPS has been shut down re None The UPS will restart automatically when utility power motely through software or an op returns tional accessory card PROBLEM AND POSSIBLE CAUSE SOLUTION ALL INDICATORS ARE LIT AND THE UPS EMITS A CONSTANT BEEPING Internal UPS fault Do not attempt to use the UPS Turn the UPS off and have it serviced immediately ALL INDICATORS ARE OFF AND THE UPS IS PLUGGED INTO A WALL OUTLET The UPS is shut down and the bat None The UPS will return to normal operation when the power tery is discharged from an extended is restored and the battery has a suffi
5. pull on the battery cables or the white cord MOUNTING THE UPS IN THE RACK Due to its weight two people are required to install the UPS in the rack 1 Supporting the UPS on both sides carefully align the unit with the rails Use the handles O on the side of the UPS to support the unit 2 Each side of the UPS has a cleat that must slide into the groove on the rails Insert each cleat into its groove and slide the UPS into position 3 Use the four ornamental screws supplied with the UPS to attach the mounting brackets to the rack post Insert the screws into the top and bottom holes in the U space 1 Supporting the battery module on the bottom align it with the opening and slide the battery module into the compartment 2 Replace the two screws to secure the battery module face plate CONNECTING THE BATTERY AND ATTACHING THE FRONT BEZEL 1 Facing the front of the UPS locate the battery cables and the UPS battery connector jack to the right of the battery module 2 To connect the battery connector plug 6 to the battery jack push the plug into the jack so the metal pieces inside each part are touching Press firmly to ensure a tight connection You will hear a snap when the connector is seated properly 3 Push the battery cables and white cord as close to the UPS as possible 4 The UPS is shipped with the front bezel removed it is packaged separately within the main box Unpack the
6. to the connected equipment from its internal battery for a finite period The UPS sounds an alarm four beeps every 30 seconds while operating on battery power The alarm stops when the UPS returns to on line operation 0 96 0 72 0 48 0 24 0 0 ZO On Battery Power Battery Charge Overload Replace Battery When the on battery power indicator is lit the UPS is supplying battery power to the connected equipment The five LED display on the right of the front panel shows the present charge of the UPS battery as a percentage of the battery capacity When all five LEDs are lit the battery is fully charged The LEDs extinguish from top to bottom as the battery capacity diminishes Refer to the figure at left for the battery capacity threshold it is not listed on the UPS As a low battery warning any LEDs illuminated for the given capacity flash and the UPS beeps The low battery warning default setting can be changed from the rear panel or through the optional PowerChute software Refer to Default Settings in this manual The UPS emits a sustained alarm tone and the LED illuminates when an overload condition occurs that is when the connected equipment exceeds the specified maximum load as defined in Specifications at the APC web site The alarm remains on until the overload is removed The UPS continues to supply power as long as it is on line and the breaker does not trip but the UPS will not provid
7. used with Interface Port the UPS Use only interface kits supplied or approved by APC If used connect the interface cable to the 9 pin computer interface port Secure the connector screws to complete the connection Use an APC supplied cable to connect to the Computer Interface Port DO NOT use a standard serial interface cable since it is incompatible with the UPS connec tor The UPS package contains a serial cable Refer to the Software Installation In struction Sheet included with the UPS Rear Connector The UPS is shipped with the rear connector plug installed as shown in the images above for 120V and 230V units The image at the left shows the receptacle when the plug is removed LL P n NORD To connect an optional external battery pack this plug is removed and replaced with the battery pack connector Refer to the 3U Rack Mount External Battery Pack User s Manual for details 6G 120V Models The UPS features a transient voltage surge suppression TVSS screw for connecting the ground lead on surge suppression de vices such as telephone and network line protectors TVSS Screw DEFAULT SETTINGS e Voltage The UPS detects line voltage distortions such as spikes notches Sensitivity dips and swells as well as distortions caused by operation with inexpensive fuel powered generators By default the UPS reacts to distortions by transferring to on battery operation to protect the connected equipmen
8. Arc www apec com User s Manual English APC Smart UPS 2200VA 3000VA 3U Rack Mount Uninterruptible Power Supply 230VAC 120VAC 990 1055A 08 01 1 SAFETY INFORMATION American Power Conversion Corporation APC is the leading national and international manufac turer of state of the art uninterruptible power supplies redundant switches power management soft ware and related equipment APC products protect hardware software and data from the threat of power disturbances in business and government offices throughout the world The APC Uninterruptible Power Supply UPS is designed to prevent blackouts brownouts sags and surges from reaching your computer and other valuable electronic equipment The UPS filters out small utility line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line The UPS provides continuous power from its internal battery until the utility line returns to safe levels HANDLING SAFETY The UPS requires two people for installation due to its weight To lighten the UPS you may remove the battery while you position or mount the UPS in the rack Note that the battery module also is heavy and requires two people for removal and installation Refer to this manual for instructions on how to remove the battery lt 18 kg lt 40 1b pay 32 55 kg 70 120 Ib I i 18 32 kg 40 70 Ib This equipment is intended for installation in a tempera
9. For the most recent and accurate sizing information please consult the Size UPS section of APC s website at www apc com sizing so eo Om m w mm TT 3000 2400 7m Runtimes at these load levels are applicable to the SU3000RMXL3U only For non power factor corrected loads the power in watts may be limited by the maxi mum VA rating 4 UsER CONFIGURATION ITEMS NOTE SETTING THESE ITEMS REQUIRES SOFTWARE OR OPTIONAL HARDWARE PONCHON FACTORY USER SELECTABLE DESCRIPTION DEFAULT CHOICES Automatic Self Every 14 days Every 7 days Test 336 hours 168 hours On Startup Only No Self Test UPS_IDEN Up to eight char acters to define the UPS This function sets the interval at which the UPS will execute a self test Refer to your software manual for details Use this field to uniquely identify the UPS for network management pur poses Date of Last Bat Manufacture Date of Battery Reset this date when you replace the tery Replacement Date Replacement battery module Minimum Capac 0 percent ity Before Return from Shutdown Reduced Low B 5 second delay 30 second delay At Low Battery Condition No Alarm 20 seconds 0 80 300 600 seconds 0 seconds 60 180 300 sec onds Sensitivity Duration of Low Battery Warning Alarm Delay After Line Fail Shutdown Delay Synchronized Turn on Delay 15 50 90 percent The UPS will charge its batteries to the specifi
10. S Store the UPS covered and flat rack mount orientation in a cool dry location with its batteries fully charged Disconnect any cables connected to the computer interface port to avoid unnecessary bat tery drainage EXTENDED STORAGE At 15 to 30 C 5 to 86 F charge the UPS battery every six months At 30 to 45 C 86 to 113 F charge the UPS battery every three months REPLACING THE BATTERY MODULE This UPS has an easy to replace hot swappable battery module Replacement is a safe procedure isolated from electrical hazards You may leave the UPS and connected equipment on for the follow ing procedure See your dealer or contact APC for information on replacement battery modules REMOVING THE FRONT BEZEL AND BATTERY MODULE 1 Remove the front bezel by reversing the instructions for attaching the front bezel found in the Installation section of this manual Set the bezel aside you will reinstall it later 2 Following the instructions in the nstallation section of this manual disconnect the battery mod ule connector plug remove the battery face plate set the screws aside you will replace them when you install a new battery and remove the battery by sliding it out of the UPS 3 Return the battery module to APC for recycling Once the battery 1s disconnected the loads are not protected from power outages REPLACING THE BATTERY MODULE AND FRONT BEZEL 1 Following the instructions in the Installati
11. TING RAILS IN THE RACK Install the mounting rails in the rack Directions are included with the rail kit The UPS comes with standard 19 inch 46 5 cm rack mounting rails brackets and cleats The rack can have any of the common types of equipment mounting holes square round threaded or round non threaded AII necessary hardware is provided REMOVING THE BATTERY MODULE The UPS is heavy To lighten it remove the battery module before mounting the unit in the rack Due to its weight two people are required to remove the battery module The battery module is accessible from the front of the UPS shown at left This procedure requires a Phillips screwdriver 1 If the UPS has been in operation locate the white cord attached to the battery module connector plug O Grasp the cord and pull firmly toward you until the connector plug is disconnected DO NOT pull the battery module cables If the UPS has not been in operation the battery will not yet be connected The UPS ships with the battery disconnected 2 Usea screwdriver to remove the two battery module mount screws located at the top corners of the face plate 6 Set the screws aside in a safe place You will re place them later 3 Locate the battery module handle at the top of the battery face plate 4 Be careful during this step the battery module is heavy Pull the battery module handle toward you to slide the battery module out of the UPS DO NOT
12. U to the connected equipment If the indicator is not lit the UPS is supplying battery power and the UPS sounds an alarm four beeps every 30 sec onds Utility Voltage The UPS has a diagnostic feature that displays the utility voltage Plug the 230V 120V UPS into the normal utility power 0266 0133 uH 0248 0124 Press and hold the button to view the utility voltage bar graph dis Dar o play After a few seconds the five LED display on the right of the front 0196 0 bs panel shows the utility input voltage Refer to the figure at left for the EN B voltage reading values are not listed on the UPS The UPS starts a self test as part of this procedure The self test does not affect the voltage display The display indicates the voltage is between the displayed value on the list and the next higher value For example with three LEDs lit the input voltage for 20V models is between 114 and 124 Vac and for 230V mod els 1s between 229 and 248 Vac If no LEDs are lit and the UPS is plugged into a working AC power outlet the line voltage is extremely low If all five LEDs are lit the line voltage is extremely high and should be checked by an electrician ZAT Voltage Trim Voltage Boost BATTERY POWER This LED illuminates to indicate the UPS is compensating for a high util ity voltage This LED illuminates to indicate the UPS is compensating for a low utility voltage If the utility power fails the UPS can provide power
13. available ask APC Customer Service about obtaining a new set Pack properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sus tained in transit is not covered under warranty Remove the rear connector plug to disconnect batteries when returning unit Always DISCONNECT THE BATTERY before shipping in compliance with U S Department of Transportation DOT regulations 5 Mark the RMA on the outside of the package 6 Return the unit by insured prepaid carrier to the address given to you by Customer Service 21 8 CONTACT REGULATORY AND WARRANTY NFORMATION CONTACTING APC Refer to the information provided at the APC Internet site http www apc com support contact REGULATORY AGENCY APPROVALS 230V MODELS Sicherheit This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take corrective actions 120V MODELS wW LISTED 42C2 LR63938 RADIO FREQUENCY INTERFERENCE This equipment has been tested and found to comply with the limits for a Class A digital device pur suant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction ma
14. bezel and hold it with the cutout sec tion on the right Align the tabs on the side of the bezel with the slots on the front of the UPS and gently snap it into place To connect an optional external battery pack s to the UPS refer to the 3U Rack Mount External Battery Pack User s Manual for instructions CONNECTING POWER AND EQUIPMENT TO THE UPS 1 On the back panel plug the UPS into a two pole three wire grounding receptacle only Avoid using extension cords and adapter plugs 2 Connect equipment to the UPS Use the cable provided with your UPS to connect to the Computer Interface Port DO NOT use a standard serial interface cable since it is incompatible with the UPS connector 3 120V Models only Connect ground leads to the TVSS screw on the back panel The transient voltage surge suppression TVSS screw provides grounding through the UPS power cord ground conductor To make the connection loosen the screw and connect the surge suppression device s ground lead Tighten the screw to secure the lead 4 Turn on all connected equipment loads To use the UPS as a master ON OFF switch be sure all connected loads are switched on The loads will not be powered until the UPS is turned on 5 Add any optional accessories See the documentation accompanying the accessory for details TURNING ON THE UPS Make sure the battery is connected before turning on the UPS Then press the button on the fro
15. cient charge outage THE REPLACE BATTERY LED IS LIT Weak battery Allow the battery to recharge for at least four hours Then per form a self test If the problem persists after recharging replace the battery Replacement battery not connected Check that the battery connector is fully engaged properly 20 SERVICE If the unit requires service do not return it to the dealer Instead follow these steps 1 Review the problems discussed in the Troubleshooting section of this manual to eliminate com mon problems 2 Verify that no circuit breakers are tripped A tripped circuit breaker is the most common problem 3 Ifthe problem persists call APC Customer Service or visit the APC website www apc com Note the model number of the unit the serial number and the date purchased If you call APC Customer Service a technician will ask you to describe the problem and try to solve it over the phone if possible If this is not possible the technician may arrange for the unit to be ser viced or may issue a Returned Material Authorization Number RMA m Ifthe unit is under warranty repairs are free If not there is a repair charge m Procedures for servicing or returning your product may vary internationally Please contact the APC Customer Service office in the appropriate country www apc com support for questions about warranty and RMA 4 Pack the unit in its original packaging If the original packing is not
16. e power from batteries in the event of a utility voltage interruption Disconnect nonessential equipment from the UPS to eliminate the over load If a continuous overload occurs while the UPS is on battery the unit turns off output in order to protect the UPS from possible damage Failure of a battery self test causes the UPS to emit short beeps for one minute and the replace battery LED illuminates LED flashes indicate the battery is disconnected The UPS repeats the alarm every five hours Per form the self test procedure after the battery has charged for 24 hours to confirm the replace battery condition The alarm stops if the battery passes the self test SHUTDOWN MODE VIA SOFTWARE OR AN ACCESSORY In shutdown mode the UPS stops supplying power to the connected equipment waiting for the re turn of utility power If there is no utility power present external devices such as servers connected to the computer interface or the accessory slot can command the UPS to shut down This normally is done to preserve battery capacity after the shutdown of protected servers The UPS scrolls the front panel indicators sequentially in shutdown mode SMART UPS REAR PANEL The rear panel has the input and output connectors computer interface port and default setting but tons for the low battery warning level and voltage sensitivity indicator 120V Models 230V Models Computer Power management software and interface kits can be
17. ed percentage before return from a shutdown Set lower than normal sensitivity to avoid lowered battery capacity and service life in situations where the con nected equipment can tolerate minor power disturbances This function sets the time before shut down at which the UPS issues a low battery warning Set it higher than the default if the operating system needs more time for shutdown Set the alarm delay to avoid alarms for minor power glitches This function sets the interval between when the UPS receives a shutdown command and when shutdown occurs The UPS will wait the specified time after the return of utility power before turn on for example to avoid branch circuit overload NOTE SETTING THESE ITEMS REQUIRES SOFTWARE OR OPTIONAL HARDWARE P NCTON FACTORY USER SELECTABLE DESCRIBHON DEFAULT CHOICES High Transfer 120V Models 120V Models To avoid unnecessary battery usage set Point 132 VAC 138 135 129 VAC the high transfer point higher if the 230V Models 230V Models utility voltage is chronically high and 253 VAC 264 271 280 VAC the connected equipment is known to work under this condition Low Transfer 120V Models 120V Models Set the low transfer point lower if the Point 103 VAC 97 100 106 VAC utility voltage is chronically low and 230V Models 230V Models the connected equipment can tolerate 196 VAC 188 204 208 VAC this condition STORAGE 5 STORAGE AND MAINTENANCE STORAGE CONDITION
18. em to make sure that the UPS will not become overloaded In the graphic to the C left the load capacity threshold 1s listed next to the LED these are not shown on the actual UPS SELF TEST Automatic The UPS performs a self test automatically when turned on and every two Self Test weeks thereafter by default Refer to the User Configuration Items for details on changing the default interval Automatic self test eases maintenance requirements by eliminating the need for periodic manual self tests During the self test the UPS briefly operates the connected equipment on battery If the UPS passes the self test it returns to on line operation If the UPS fails the self test the UPS lights the replace battery LED and immediately returns to on line operation The connected equipment is not affected by a failed test Recharge the battery for 24 hours and perform another self test If it fails the battery must be replaced Manual Self Test Press and hold the button for a few seconds to initiate the self test UriLITY POWER During normal operation the UPS monitors the utility power and delivers power to the connected equipment If your system is experiencing excessive periods of high or low voltage have a certified electrician check your facility for electrical problems If the problem continues contact the utility company for further assistance On Line The on line indicator illuminates when the UPS is supplying utility power
19. illuminates when the UPS is connected to an im Site Wiring properly wired AC power outlet Fault Indicator If the UPS indicates a site wiring fault get a qualified electrician to correct the building wiring CiRCUIT BREAKERS Input Circuit One 40 Amp input circuit breaker is provided to the right of the Breaker rear connector plug and battery pack connector Output Circuit Three output circuit breakers are provided Breakers 13 ON BATTERY OPERATION The Smart UPS switches to battery operation automatically if the utility power fails While running on battery an internal alarm sounds periodic beeps Press the button front panel to silence the UPS alarm for the current alarm only You can change the audible indicator if you are using the PowerChute software If the utility power does not return the UPS continues to supply power to the connected equipment until exhausted The UPS will begin to beep continuously approximately two minutes before the UPS final low battery shutdown If using a computer you must manually save your files and power down before the UPS turns off unless you are using PowerChute interface software that provides auto matic unattended shutdown DETERMINING ON BATTERY RUN TIME UPS battery life differs based on usage and environment It is recommended that the battery batteries are changed once every three years Although the following run times are typical these numbers are subject to change
20. l Park Suzhou 215021 Jiangsu P R C Importer s Name and Address American Power Conversion A P C b v Ballybritt Business Park Galway Ireland Place N Billerica MA U S Eb A EE cn Va daka vc Richard J Everett Sr Regulatory Compliance Engineer Place Galway Ireland 2r du 4 F PON 5 Jan 01 Ray S Ballard Managing Director Europe Phone 353 917 02000 Fax 353 9175 6909 LIMITED WARRANTY American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment that has been damaged by acci dent negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit li
21. mitation or exclusion of implied warranties there fore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not li able for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Entire contents copyright O 2001 by American Power Conversion Corporation All rights reserved Reproduc tion in whole or in part without permission is prohibited APC Smart UPS and PowerChute are registered trademarks of American Power Conversion Corporation All other trademarks are the property of their respective owners 23
22. nt panel to power up your UPS This will power up connected equipment Make sure connected loads are switched to their ON position The UPS charges its battery when it is connected to utility power The battery charges fully during the first four hours of normal operation Do not expect full run time during this initial charge period The unit performs a self test automatically when turned on and every two weeks thereafter by de fault Refer to details below on changing the default interval 120V Models Check the site wiring fault indicator located on the rear panel see Rear Panel be low It lights up if the UPS is plugged into an improperly wired AC power outlet Wiring faults de tected include missing ground hot neutral polarity reversal and overloaded neutral circuit ACCESSORIES This UPS is equipped with an accessory slot See the APC website www apc com for available ac cessories If a standard accessory such as an SNMP card is installed on this UPS see the Utility CD for user documentation For additional computer system security install PowerChutePlus Smart UPS monitoring software It provides automatic unattended shutdown capabilities on most major network operating systems 3 OPERATION INDICATORS AND CONTROLS ON THE SMART UPS The APC Uninterruptible Power Supply UPS is designed to prevent blackouts brownouts sags and surges from reaching your computer and other valuable electronic equipment
23. nual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits 22 DECLARATION OF CONFORMITY CE 2001 EC Declaration of Conformity We the undersigned declare under our sole responsibility that the equipment specified below conforms to the following standards and directives Standards to Which Conformity Declared EN50091 1 EN60950 EN50091 1 1 IEC60950 EN55022 EN50091 2 EN61000 3 2 EN61000 3 3 Application of Council Directives 73 23 EEC 93 68 EEC 89 336 EEC 92 3 1 EEC 93 68 EEC 91 157 EEC Type of Equipment Uninterruptible Power Supply Model Numbers SU3000RMXLI3U Manufacturer s Name and Address American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA Or American Power Conversion A P C b v Ballybritt Business Park Galway Ireland Of American Power Conversion Main Avenue Peza Rosario Cavite Philippines Or American Power Conversion 2nd Street Peza Cavite Economic Zone Rosario Cavite Philippines Or American Power Conversion Lot 32 Phase 1 Carmelray Industrial Park Canlubang Calamba Luguna Philippines Or APC Suzhou UPS Co Ltd No 189 Suhong Road China Singapore Suzhou Industria
24. on section of this manual slide the new battery into place in the UPS reattach the battery face plate using the screws set aside in Step 2 above and insert the battery module connector plug 2 Replace the front bezel 6 TRANSPORTING YOUR SMART UPS REMOVING THE UPS FROM THE RACK Always DISCONNECT THE BATTERY before shipping the UPS to avoid damage during transport U S Federal Regulation requires that batteries are disconnected during shipment The battery may remain in the UPS it does not have to be re moved This requirement applies whether the UPS is shipped alone or installed in an equipment rack or system REMOVING THE FRONT BEZEL 1 Shut down any equipment attached to the UPS 2 Disconnect the UPS from the power supply 3 If you are using the original UPS packaging you must transport the front bezel separate from the UPS Remove the front bezel Use both hands and grasp the finger clips on either side of the bezel Pull it toward you The bezel will unsnap from the UPS REMOVING THE UPS FROM THE RACK Due to its weight removing the UPS from a rack requires two people 1 Remove the four rack screws two screws on each mounting bracket that secure the UPS to the rack D 2772 2 Grasp the battery module handle and pull it to ward you to pull the UPS out far enough to sup port the front of the UPS from the underside e 3 Use the handles on the sides of the UPS for addi ar
25. t Where power quality is poor the UPS may frequently transfer to on battery operation If the connected equipment can operate normally under such con ditions reduce the sensitivity setting to conserve battery capacity and service life 12 To reduce UPS sensitivity press the voltage sensitivity button Use a pointed object such as a pen to do so Press the button once to set sensitivity to reduced Press it again to set sensitivity to low Press the button a third time to reset normal sensitivity You also can change the sensitivity level through software X normal Brightly lit UPS is set to normal sensitivity Q reduced Dimlylit UPS is set to reduced sensitivity di Off UPS is set to low sensitivity Low Battery The low battery warning beeps to indicate low on battery run Warning Level time It beeps periodically approximately three times per minute when less than seven minutes of run time remain The beeps are continuous when only two minutes of run time remain This may not be enough time to shut down some protected com puter systems To change the warning interval default setting press the voltage sensitivity button while pressing and holding the front panel button je 2 min Brightly lit Low battery warning interval 1s about two minutes 5 min Dimly lit Low battery warning interval is about five minutes 7 min Off Low battery warning interval is about seven minutes e 120V Models This indicator
26. t is not connected to an AC power outlet m Todeenergize pluggable equipment press the OFF button for more than one second to switch the equipment off Disconnect the equipment from the AC power outlet Unplug the bat tery connector Push the button labeled to deenergize the capacitors m Pluggable equipment includes a protective earth conductor that carries the leakage current from the load devices computer equipment Total leakage current must not exceed 3 5 mA l m Todeenergize permanently wired equipment set the power switch to standby M l NM m Set the AC circuit breaker to standby O and then disconnect the batteries including any expan sion units Finally disconnect the AC power from the building power supply m Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended BATTERY SAFETY This equipment contains potentially hazardous voltages that may cause personal injury if handled incorrectly This equipment must be installed and serviced only by qualified electrical service personnel This equipment contains potentially hazardous voltages Do not attempt to disassemble the unit The only exception is for equipment containing batteries Battery replacement using the proce dures below is permissible Except for the battery the unit con
27. tains no user serviceable parts Re pairs are to be performed only by factory trained service personnel Do not dispose of batteries in a fire The batteries may explode Do not open or mutilate batteries They contain an electrolyte that is toxic and harmful to the skin and eyes Do not connect the terminals of a battery or battery pack with a wire or other electrically conduc tive objects To avoid personal injury due to energy hazard remove wristwatches and jewelry such as rings when replacing the batteries Use tools with insulated handles Replace batteries with the same number and type of batteries or battery packs as originally in stalled in the equipment BATTERY REPLACEMENT AND RECYCLING See your dealer or visit the APC web site www apc com support for information on replacement battery kits and battery recycling d Be sure to return the spent battery to APC for recycling Ship it to APC in the re placement battery packing material 2 INSTALLATION The UPS has a rack design so it can be mounted in a 19 inch 46 5 cm equipment rack Hardware is provided UNPACKING Inspect the UPS upon receipt APC designed robust packaging for your product However acci dents and damage may occur during shipment Notify the carrier and dealer if there is damage The packaging is recyclable save it for reuse or dispose of it properly 2 Check the package contents The shipping package contains the UPS with ba
28. tteries discon nected its front bezel packaged separately mounting rails mounting cleats hardware packet necessary for rack mounting the UPS and a literature kit containing cable s and product documentation The UPS is shipped with the front bezel removed it is packaged separately within the main box You will connect the plastic bezel described later during the installation procedure POSITIONING THE UPS Place the rack and the UPS where they will be used The UPS is heavy Select a location sturdy enough to handle the weight You must install the UPS in a protected area that is free of excessive dust and has adequate airflow Ensure the air vents on the front and rear of the UPS are not blocked Allow at least one inch of space on both sides Do not operate the UPS where the temperature and humidity are outside the specified limits Refer to Specifications at the APC web site www apc com PLACEMENT oem n E ee FT T El ES J 2 v v XXX x n INSTALLING THE SMART UPS To install the Smart UPS follow these basic steps Details are provided on the following pages Install the mounting rails in the rack Remove the battery module Mount the UPS in the rack Install the UPS at or near the bottom of the rack Reinstall the battery module au dE m 5 Connect the battery and attach the front bezel 6 Connect the equipment and power to the UPS 7 Turn on the UPS INSTALLING THE MOUN
29. ture controlled indoor area free of conductive contaminants Refer to Specifications at the APC web site for the actual temperature range LIFE SUPPORT APPLICATION POLICY As a general policy APC does not recommend the use of any of its products in life support applica tions where failure or malfunctions of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness APC does not recom mend the use of any of its products in direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of APC is adequately protected under the circumstances gt 55 kg 7120 Ib Examples of devices considered to be life support devices are neonatal oxygen and analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators infusion pumps and any other device designated as critical by the U S F D A Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems