Home

Tripp Lite OmniSmart UPS System

image

Contents

1. 2 N Outros Elementos Do UPS Conetores AC Tas tomadas fornecem em funcionamento normal corrente alterna ao equipamento nelas conetado e alimentac o provinda da bateria durante as interrup es ou baixas moment neas de corrente Tamb m protegem o o seu equipamento contra os danos causados pelas varia es moment neas de tens o ou pelo ru do da linha Nos modelos exclusivos por m existem conetores com fun o espec fica de protec o contra as sobretens es identificados na retaguarda do UPS os quais protegem os elementos perif ricos contra as sobretens es sem consignar a reserva da bateria preciosa logo que hajam cortes da corrente Tomadas telef nicas RJ11 inclu das nos modelos exclusivos mus m Estas tomadas protegem o seu equipamento contra as sobretens es da m linha telef nica A conex o do seu equipamento a estas tomadas facultativa O sistema UPS funciona convenientemente mesmo sem esta conex o Terminal DB9 Disponible a certains modeles O Terminal DB9 permite a conex o do UPS a qualquer estac o de trabalho ou servidor Utilize o software Tripp Lite e respetiva conex o para proteger automaticamente os ficheiros abertos e desligar automaticamente o equipamento durante os cortes de corrente Este terminal envia sinais para fecho do contato indicando seja um defeito na linha seja que a carga da bateria fraca Contate o Servico de Assist ncia a Clientela Tripp Lite se quiser obter mais info
2. No abra las bater as No corte o conecte las teminales de la bater a con ning n objeto Las bater as de este sistema UPS son reciclables Refi rase al c digo local de requisitos para la disposici n de bater as No use fuego para disponer de las bater as No intente agregar bater as externas Instalaci n Inmediata Conecte el sistema UPS a una toma de corriente Conecte su computadora monitor y m dem externo a los recept culos con energ a de respaldo Conecte otros equipos a los recept culos del sistema UPS con supresor de picos solamente Opcional Modelos selectos Utilizando el cable Tripp Lite si es suministrado conecte el puerto DB9 de su computadora al puerto DB9 del sistema UPS Instale el software si es suministrado ejecutando el programa de instalaci n apropiado para su sistema operativo Utilizando cables telef nicos conecte el contacto del sistema UPS rotulado LINE l nea o IN entrada al contacto telef nico en la pared Conecte el equipo que desea proteger al contacto del sistema UPS rotulado EQUIP equipo o OUT salida Encienda el sistema UPS ON Si el sistema UPS incluye recept culos separados con energ a de respaldo y recept culos con supresor de picos solamente identificados en la parte posterior del sistema UPS Este sistema UPS ha sido dise ado para respaldar equipos de computaci n Usted sobrecargar el sistema
3. efetuar o teste Se o alarme torna a tocar contate o servico de assist ncia Tripp Lite ATEN O N o desligue o UPS da corrente el ctrica quando verifica as baterias Esta opera o anula a prote o de liga o terra podendo introduzir danos de sobretens o nas suas conex es em rede Indicadores Luminosos As descri es relativas a todos os indicadores luminosos se aplicam somente quando o seu sistema UPS est ligado a uma tomada de corrente da rede el trica e em funcionamento o interruptor selecionado em posi o ON Este indicador luminoso verde acende quando o seu sistema UPS est ligado corrente e alimentado em linha AC Este indicador luminoso vermelho acende quando o UPS alimenta o equipamento nele conetado com a carga da bateria Este indicador luminoso amarelo acende quando a reserva da bateria do UPS come a a baixar Se ele se mantiver aceso em perman ncia contate o servi o de assist ncia Tripp Lite Este indicador luminoso verde acende se sempre que o UPS est corrigindo automaticamente as varia es de descida ou subida da tens o da linha el trica de distribui o p blica Este indicador luminoso vermelho acende se quando a capacidade do UPS for ultrapassada quando este alimentado pela bateria seja durante um teste autom tico ou seja durante um corte de corrente Retire imediatamente a sobrecarga das sa das auxiliares da bateria RES Disponible certains mod les
4. funciona convenientemente sem estas conex es Assegure se que o equipamento que coneta tomada telef nica tamb m est protegido a n vel da linha da instala o el trica contra os danos das sobretens es 21 Funcionamento B sico Interruptores Depois de ter instalado o sistema UPS regule a alimenta o do equipamento conetado ao UPS em linha AC Nota S os modelos UPS equipados com um interruptor Mute Test lhe permitem o arranque a frio podendo ser utilizados como fonte de alimentac o aut noma ON OFF a Utilize este interruptor de a o moment nea para executar duas fun es CTI Interromper o alarme de corte de corrente Desloque este interruptor para a esquerda largando o em seguida Normalmente o alarme se interrompe retirando a carga em excesso Nota O alarme recomeca e n o pode ser interrompido quando a bateria est praticamente esgotada avisando o que deve apagar imediatamente o equipamento conetado ao sistema Testar a carga da bateria UPS Deixe o equipamento ligado em posic o ON Com o sistema UPS ligado a corrente e ajustado em posic o ON desloque este interruptor para a esquerda mantenha o nesta posic o durante 2 segundos e depois largue o O UPS se coneta momentaneamente bateria para verificar a carga respetiva Se o alarme do sistema UPS ressoa ou se o sistema n o aguenta a capacidade de carga prevista deixe as baterias do UPS a carregar durante 12 horas e torne a
5. life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object e The UPS batteries are recyclable Refer to local codes for disposal requirements or call 1 800 SAV LEAD 1 800 728 5323 for complete recycling information Do not dispose of the batteries in a fire e Do not attempt to add external batteries Quick Installation 1 Plug your UPS into an electrical outlet 2 Plug your computer monitor and external modem into battery supported outlets Plug other equipment into surge only outlets Optional Select models Using Tripp Lite cable if supplied connect the DB9 port of your computer to the DB9 port of your UPS Load software if supplied and run installation program
6. prise du syst me d onduleur Ne branchez pas le systeme d onduleur a soi m me cela endommagera le syst me d onduleur et nullifiera votre garantie e Si vous branchez votre syst me d onduleur une gazog ne motoriz e celui ci doit fournir une propre alimentation de sortie filtr e convenable aux ordinateurs Avertissements de la Connexion d Equipement e N utilisez pas les syst mes d onduleur Tripp Lite avec les applications de support vie o un d faut du systeme d onduleur peut causer un d faut de ou peut modifier la performance de l quipement de support vie Avertissements de la Batterie e Votre syst me d onduleur n exige pas d entretien routine N ouvrez pas votre syst me d onduleur pour n importe raison Il n y a pas de parties serviceables par l utilisateur e Le remplacement de la batterie doit tre fait par un personnage de service qualifi Puisque les batteries pr sentent un risque de choc l ctrique et de br lure du courant de court circuit observez les precautions propres Arr tez et d branchez le syst me d onduleur avant de remplacer les batter ies Utilisez des outils insul s et remplacez les batteries avec des batteries du m me nombre et du m me type Plomb et Acide Ferm N ouvrez pas les batteries Ne courtez pas et ne cr ez pas un pont aux terminales de la batterie avec aucun objet e Les batteries du syst me d onduleur sont recyclable Vous r f rez aux codes locaux pour
7. rias N o queime as baterias e N o tente acrescentar baterias externas 20 Instalac o R pida Introduza a ficha do UPS numa tomada de electricidade 2 Ligue o seu computador monitor e modem externo as saidas auxiliares da bateria Ligue o resto do seu equipamento unicamente as tomadas do sistema UPS protegidas contra as sobretens es Op es Existentes nos modelos exclusivos Ligue por meio do cabo Tripp Lite se inclu do o terminal DB9 do seu computador ao terminal DB9 existente no UPS Instale o software se inclu do e processe o programa de instalac o apropriado ao sistema de explorac o existente no seu computador Conete o cord o telef nico da sua instalac o a tomada do UPS denominada LINE ou IN Conete o seu equipamento a tomada do UPS denominada EQUIP ou OUT Ajuste o interruptor do UPS em posic o ON Se o sistema UPS que possui estiver equipado com tomadas de sa da separadas em dois grupos sa das alimentadas pela bateria e sa das protegidas contra as sobretens es identificadas na parte traseira do UPS O sistema UPS que possui foi concebido unicamente para suportar equipamento inform tico Ele ser sobrecarregado se conetar aparelhos el tricos de uso dom stico impressoras laser ou supressores das variac es da corrente s sa das auxiliares da bateria A conex o da linha telef nica e do terminal DB9 facultativa O sistema UPS
8. 17 5 17 5 17 5 Tempo de Execu o Normal Unidade PC Monitor 15 in Min 30 30 45 Tempo de carregamento da Bateria 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL cUL UL cUL UL cUL Prote o Modem Fax a partir de 260V 1 linha 1 linha 2 linhas OmniSmart 850 OmniSmart 1050 OmniSmart 1400 Capacidade de Sa da VA Watt 850 570 1050 705 1400 940 Tempo de Execu o da Bateria Meia Carga Carga Total Min 26 9 23 7 24 8 Tempo de Execu o Normal Unidade PC Monitor 15 in Min 55 65 75 Tempo de Carregamento da Bateria 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL cUL UL cUL UL cUL Prote o Modem Fax a partir de 260V OmniPro 280 OmniPro 450 OmniPro 675 Capacidade de Sa da VA Watt 280 175 450 300 675 425 Tempo de Execuc o da Bateria Meia Carga Carga Total Min 17 5 17 5 17 5 Tempo de Execu o Normal Unidade PC Monitor 15 in Min 15 30 45 Tempo de Carregamento da Bateria 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL cUL UL cUL UL cUL Prote o Modem Fax a partir de 260V 1 linha 2 linhas TODOS OS MODELOS Voltagem Frequ ncia de Entrada 120 V 60 Hz Amplitude da Tens o de Entrada em Linha 87 145 volts Amplitude da Tens o de Sa da Regul vel 120V 6 12 Amplitude da Tens o de Sa da da Bateria 120V 5 Forma da onda de Sa da em Modo Linha onda sinusoidal filtrada Forma da onda de Sa da em Modo Bateria onda sinusoida
9. L Protection Modem Fax commence 260V 1 ligne 2 lignes TOUS LES MODELES Tension Fr quence d Entr e 120V 60 Hz Gamme de Tension d Entr e quand En Ligne 87 145 volts Gamme de Tension de Sortie quand sur Batterie 120V 6 12 Mode d Onde de Sortie quand En Ligne onde sinuso dale filtr e Mode d Onde quand sur Batterie onde sinoidale PWM Suppression de Surtensions C A exc de les standards de IEEE 587 Cat gories A et B Att nuation des Parasites C A gt 40 dB Modes de Protection C A Ligne a Neutre Ligne a Terre Neutre a Terre 19 SEGURANCA O presente manual cont m instru es importantes e advert ncias que devem ser seguidas durante a instalac o utilizac o e arrumac o de todos os sistemas UPS Tripp Lite Advert ncias Relativas a Instalac o do UPS e Instale o seu sistema UPS no interior da sua habita o afastado da humidade ou de calor excessivos da poeira ou da iluminac o direta dos raios solares e A fim de obter o melhor desempenho do sistema mantenha a temperatura ambiente entre 32 F e 104 F de 0 C a 40 C e Deixe suficientemente de espa o roda do UPS para que este seja bem ventilado Advert ncias Relativas Conex o do UPS e Conete o seu sistema UPS a uma tomada tripolar ligada terra N o retire nem modifique o pino de terra da ficha UPS e N o utilize adaptadores de dois pinos com a ficha UPS N o introduza a ficha do UPS nos conetores
10. Owner s Manual OMNISMART OMNIPRO Was TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Line Interactive UPS Systems 120V ESPANOL p 8 FRAN AIS p 14 PORTUGUES p 20 Safety p 2 Quick Installation p 3 Basic Operation p 4 5 Storage amp Service p 6 Specifications p 7 Copyright 1999 Tripp Lite All rights reserved OmniSmart and OmniPro are trademarks of Tripp Lite Safety A This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems UPS Location Warnings e Install your UPS indoors away from excess moisture or heat dust or direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F between O C and 40 C e Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS to a three wire grounded AC power outlet Do not remove or modify the ground pin of the UPS s plug Do not use two prong adapters with the UPS s plug Do not plug your UPS into itself this will damage the UPS and void your warranty e If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for
11. UPS si conecta dispositivos electrodom sticos impresoras l ser o supresores de picos a los recept culos con energ a de respaldo Las conexiones telef nicas y de puertos DB9 son opcionales El sistema UPS funcionar adecuadamente sin estas conexiones Aseg rese que el equipo conectado a los contactos telef nicos del sistema UPS tambi n est n protegidos contra peligrosos picos el ctricos en la l nea de CA 9 Operaci n B sica Interruptores Una vez que el sistema UPS est conectado a la l nea de CA encienda el ON m DEF sistema UPS para suministrar energ a de CA a los equipos conectados Importante Solamente los modelos provistos con un interruptor Mute Test Silenciador de Alarma Prueba permiten el arranque en fr o del sistema UPS y su uso como fuente aut noma de energ a Use este interruptor moment neo para dos cosas MUTE TEST Silenciador de Alarma Deslice este interruptor hacia la izquierda y su ltelo Normalmente el desconectar parte de la carga silenciar la alarma Importante Cuando la bater a est muy desgastada la alarma sonar nuevamente y no prodr ser silenciada para indicarle que todos los equipos conectados deben ser apagados inmediatamente Prueba de la Carga de la Bater a Encienda los equipos conectados Con el sistema UPS encendido y conectado a la l nea de CA deslice este interruptor hacia la izquierda presi nelo durante 2 segundos y su ltelo El sistema UPS
12. appropriate for your operating system Using telephone cords connect your wall jack to the UPS jack marked LINE or IN Connect your equipment to the UPS jack marked EQUIP or OUT 3 Turn your UPS s power switch ON Separate battery supported surge and surge only outlets are available only on select models identified on the back of your UPS Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors to the battery supported outlets Phone line and DB9 port connections are optional Your UPS will function properly without these connections Make sure the equipment you connect to the UPS s telephone jacks is also protected against damaging surges on the AC line 3 Basic Operation Switches ON OFF With your UPS plugged in turn the UPS ON to supply AC power to your connected equipment Note Only UPS models equipped with a Mute Test switch allow you to cold start them and use them as stand alone power sources MUTE TEST Use this momentary switch to do two things Silence the blackout alarm Move this switch to the left and release it Normally removing some of the load will silence the alarm Note When the battery is nearly depleted the alarm resumes and cannot be silenced to alert you to immediately shut down connected equipment Test your UPS s battery charge Leave your connecte
13. d equipment ON With your UPS plugged in and turned ON move this switch to the left hold it there for 2 seconds and release it The UPS will momentarily switch to battery to test its charge If the UPS alarm sounds or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned on This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing your equipment with battery power This yellow light will turn ON when the UPS battery is less than fully charged If it stays on continuously contact Tripp Lite for service Whenever your UPS is automatically correcting high or low AC line voltage this green light will turn ON and the UPS will gently click The more the UPS has to correct voltage the more the green light will turn ON and the more the UPS will click These are both normal automatic operations of your UPS and no action is required on your part Sup Available on select models EN This red light will turn ON when the UPS s capacity has been exc
14. do pr prio sistema pois isto danificaria o sistema e anularia a garantia e Se ligar o seu sistema UPS a um gerador de corrente alterna este deve fornecer uma alimenta o limpa filtrada e conforme ao n vel de sa da do seu computador Advert ncias Relativas Conex o do Equipamento e N o utilize o sistema Tripp Lite UPS para alimentar sistemas de ressuscitamento pois nestes casos o mau funcionamento ou falha do Sistema UPS Tripp Lite poderiam causar danos ou alterac es importantes no funcionamento do dispositivo de suporte vital Advert ncias Relativas a Bateria e O seu sistema UPS nao necessita de manuten o regular N o abra o sistema seja qual for o motivo Dentro n o existem elementos utiliz veis e A substitui o da bateria deve ser feita por um t cnico habilitado e Siga as precau es relativas bateria pois esta pode exp lo a riscos de choque el ctrico ou de queimadura provocados por curto circuito de alta tens o Desligue e retire a ficha do UPS da tomada da instala o el trica antes de proceder substitui o da bateria Utilize ferramentas de cabo isolado e substitua as baterias usadas por novas baterias do mesmo tipo e da mesma refer ncia bateria de cido e chumbo selada N o abra as baterias N o curte circuite nem ligue em ponte os terminais da bateria seja qual for a raz o e As baterias UPS s o recicl veis Refira se aos c digos locais a fim de obter as disposi es necess
15. eak Estas son condiciones normales y autom ticas del no break y no requieren ninguna acci n de su parte Esta luz roja se encender cuando la capacidad del sistema UPS haya sido excedida y mientras est operando con la energ a de la bater a durante un apag n o autoprueba Desconecte inmediatemente la sobrecarga de los recept culos con energ a de respaldo S Disponible en modelos selectos Otras Caracter sticas del Sistema UPS Recept culos de CA Los recept culos proveen energ a de CA durante condiciones normales de operaci n y energ a de bater a durante apagones y ca das de voltaje Tambi n protegen sus equipos contra picos y ruidos de l nea No obstante algunos modelos incluyen recept culos con supresor solamente 2 identificados en la parte posterior del sistema UPS que proveen protecci n contra picos para equipos perif ricos sin utilizar la valiosa energ a de la bater a para respaldarlos durante apagones Contactos Telef nicos Tipo RJ11 Disponibles en modelos selectos Estos contactos protegen sus equipos contra picos en las l neas telef nicas La conexi n de sus equipos a estos contactos es opcional El sistema UPS funcionar adecuadamente a n sin esta conexi n Puerto DB9 A en modelos selectos El puerto DB9 conecta su sistema UPS a cualquier estaci n de trabajo o servidor de archivos Utilice este puerto con el software y el cableado de Tripp Lite para salvar autom tica
16. eeded while it is operating from battery power either during a self test or during a blackout Remove overload from battery supported outlets immediately Other UPS Features AC Receptacles The receptacles provide your connected equipment with AC line T T power during normal operation and battery power during black outs and brownouts They also protect your equipment against damaging surges and line noise Select models however feature surge only receptacles identified on the back of the UPS that provide peripherals with surge protection without committing precious battery power to support them during blackouts RJ11 Telephone Jacks Available on select models These jacks protect your equipment against telephone line surges Connecting your equipment to these jacks is optional Your UPS will still work properly without this connection DB9 Port Available on select models y The DB9 port connects your UPS to any workstation or server Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout This port sends contact closure signals to indicate line fail and low battery status Contact Tripp Lite Customer Support for more information Battery Replacement Door Under normal conditions the original battery in your UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnin
17. es you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment Fax Modem Protector please contact the Manager of Technical Support Tripp Lite 1111 W 35th Street Chicago Illinois 60609 Phone 773 869 1234 for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Fax Modem Protector This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation commission for information Seguridad A Este manual de operaci n contiene instrucciones y advertencias importantes que deben seguirse durante la instalaci n operaci n y almacenamiento del sistema UPS Tripp Lite Advertencias Sobre la Ubicaci n del Sistema UPS Instale este sistema UPS bajo techo en un lugar sin humedad o calor excesivo y sin polvo o luz solar directa Para obtener mejores resultados mantenga la temperatura ambiental entre 32 F y 104 F entre 0 C y 40 C Permita suficiente espacio alrededor de esta unidad para facilitar la ventilaci n apropiada de la misma Advertencias Sobre la Conexi n del Sistema UPS Conecte este sistema UPS a una toma de cor
18. es fichiers ouverts et pour arr ter votre quipement pendant une coupure de courant Ce port envoie les signals au port secondaire pour indiquer un tat de line fail d faut de ligne ou de low battery batterie d charg e Contactez l Assistance Client de Tripp Lite pour plus d informations Porte Commode du Remplacement de la Batterie Disponibles a certains modeles En conditions normales la batterie originaire durera pendant plusieurs ann es Le remplacement de la batterie doit tre fait par les personnage de service qualifi s seulement Vous r f rez la section Avertissements de la Batterie sur a la page 14 17 Emmagasinage et Service Emmagasinage Premi rement teindez votre syst me d onduleur et d branchez son cordon d alimentation de la prise murale Puis d branchez tout quipement pour viter la d chargement de la batterie Si vous emmagasinerez votre systeme d onduleur pendant longtemps rechargez compl tement la batterie une fois tous les trois mois par branchez le systeme d onduleur a une prise murale de c a bougez l interrupteur principale ON Marche et laissez le charger pendant 4 6 heures Si vous laissez les batteries d charg es pendant longtemps elles suffriront une manque permanent de capacit Service Si vous retournez votre syst me d onduleur a Tripp Lite emballez soigneusement le syst me d onduleur en utilisant le MATERIEL D EMBALLAGE ORIGINAIRE inclu
19. gs in the Safety section on page 2 Storage 8 Service Storage First turn your UPS OFF and disconnect its power cord from the wall outlet Then disconnect all equipment to avoid battery drain If you plan to store your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet turning the Power Switch ON and letting the UPS charge for 4 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning your UPS to Tripp Lite please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem Ifthe UPS is within the 2 year warranty period enclose a copy of your sales receipt Specifications OmniSmart 300 OmniSmart 450 OmniSmart 675 Output Capacity VA Watts 300 180 450 300 675 425 Battery Runtime Half Load Full Load Minutes 17 5 17 5 17 5 Typical Runtime Desktop PC 15 in monitor Minutes 30 30 45 Battery Recharge Rate 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL UL cUL UL cUL Modem Fax Protection starts at 260V 1 line 1 line 2 line OmniSmart 850 OmniSmart 1050 OmniSmart 1400 Output Capacity VA Watts 850 570 1050 705 1400 940 Battery Runtime Half Load Full Load Minutes 26 9 23 7 24 8 Typical Runtime Desktop PC 15 in monitor Min
20. l PWM Eliminac o ondulat ria AC ultrapassa a norma IEEE 587 Cat Standards A amp B Atenua o de Ru do da linha AC gt 40 dB Modos de Prote o em Linha AC de Ha N de Ha G de Na G 93 1308 9811194 4 99 Printed on Recycled Paper 24
21. les exigences de d struction ou t l phonez a 1 800 SAV LEAD 1 800 728 5323 pour les informations compl tes Ne disposez pas des batteries en feu e N essayez pas d ajouter des batteries externes Installation Rapide Branchez votre syst me d onduleur a une prise l ctrique 2 Branchez votre ordinateur moniteur et modem ext rieur aux prises de PUPS avec secours par batterie Branchez les autres quipements aux prises de UPS avec suppression de surtensions seulement Facultatif Certains mod les Utilisant le cabl ge de Tripp Lite si fournit connectez le port DB9 de votre ordinateur au port de UPS Lancez le logiciel si fournit et exploitez le programme d installation propos de votre syst me d exploitation Utilisant les cordons t l phoniques connectez votre prise murale la prise de PUPS marqu LINE LIGNE ou IN ENTREE Connectez votre quipement la prise de UPS marqu EQUIP EQUIPEMENT ou OUT SORTIE Allumez l interrupteur 3 principale de votre syst me d onduleur mettez le ON Marche Si votre UPS offre des prises s par es avec secours par batterie plus suppression et des prises avec suppression de surtensions seulement identifi es l arri re de l UPS Votre UPS peut supporter du mat riel informatique seulement Vous surchargerez votre UPS si vous connectiez les appareils do
22. mente sus archivos activos y cerrar su sistema de computaci n durante un apag n Este puerto env a se ales alos puertos secundarios para indicar una falla de CA line fail o cuando la bater a est desgastada low battery Comun quese con el Departmento de Soporte t cnico para obtener m s informaci n Puerta para el Reemplazo de la Bater a E Bajo condiciones normales la bater a original incluida con el sistema EA UPS durar varios a os El reemplazo de la bater a debe ser realizado solamente por personal t cnico capacitado Refi rase a la secci n Advertencias Sobre la Bater a en la p gina 8 11 Almacenamiento y Servicio Almacenamiento Primero apague el sistema UPS y desconecte su cable de la l nea de CA Despu s desconecte todos sus equipos para evitar el desgaste de la bater a Si usted necesita almacenar su sistema UPS por un periodo extendido de tiempo recargue totalmente las bater as una vez cada tres meses encendiendo y conectando el sistema UPS a una l nea activa de CA y permitiendo que el sistema UPS cargue sus bater as por 4 6 horas Si usted mantiene las bater as descargadas por un periodo extendido de tiempo stas sufrir n la p rdida permanente de capacidad de recarga Servicio Si usted necesita enviar el sistema UPS al centro de servicio de Tripp Lite emp quelo cuidadosamente usando el MATERIAL ORIGINAL DE EMPAQUE incluido con la unidad Adjunte una carta desc
23. mestiques les imprimantes laser ou les suppresseurs de surtensions aux prises de l UPS avec secours par batterie Les connexions d une ligne t l phonique et d un port DB9 sont facultatifs Votre UPS fonnctionnera proprement sans ces connexions Soyez s r que l quipement connect aux plots t l phoniques est aussi prot g contre les surtensions endommageantes sur la ligne c a 15 Op ration de Base Interrupteurs ON OFF Quand votre UPS est branch une prise murale c a allumez UPS pour fournir l alimentation c a l equipement connect Notez Seulles systemes d onduleur quip s d un interrupteur Mute Test Amortissage Test peuvent tre allum s a froid et utilis s comme sources d alimentation autonome MUTE TEST Utilisez cet interrupteur momentan afin d effectuer ces deux op rations Amortir l alarme de coupure de courant panne d lectricit Bougez cet interrupteur a la gauche et le lachez Normalement lallegement de la charge va faire taire alarme Notez L alarme reprendra et ne peut pas tre amorti quand la batterie est presque d charg e pour que vous soyez alert d arr ter votre quipement tout de suite Contr ler Tester la charge de la batterie Laissez votre quipement marcher Quand votre syst me d onduleur est branch la ligne c a et mise en marche bougez cet interrupteur la gauche y tenez pendant 2 seconds avant de le l chez Le syst me d onduleu
24. n Para M dem Fax Comienza a 260V 1 l nea 2 l neas TODOS LOS MODELOS Voltaje y Frecuencia de Entrada 120v 60Hz Gama de Voltaje de Entrada 87 45 volts Gama de Voltaje Regulado de Salida 120V 6 12 Gama de Voltaje de Salida en Bater a 120V 5 Tipo de Onda de Salida En L nea senoidal filtrada Tipo de Onda de Salida en Bater a Senoidal Modulada en Ancho de Pulso Supresi n de Picos de CA excede las normas de IEEE 587 Cat A y B Atenuaci n de Ruidos de CA gt 40 dB Modos de Protecci n L nea a Neutro L nea a Tierra Neutro a Tierra 13 S ret A Ce manuel contient des instructions et des avertissements importantes pour l installation l op ration et lemmagasinage de tout syst me d onduleur Tripp Lite 14 Avertissements du Placement du Syst me d Onduleur e Installez le syst me d onduleur en dehors loin d humidit de chaleur de poussi re et de lumi re de soleil directe e Pour la meilleure performance maintenez la temp rature en dehors entre 0 C et 40 C 32 F et 104 F e Garder plein d espace autour du syst me d onduleur pour maintenir la ventilation convenable Avertissements de la Connexion du Systeme d Onduleur e Brachez votre syst me d onduleur une prise d alimentation c a de trois fils et mise a terre N 6tez pas et ne modifiez pas le fil de terre du prise du systeme d onduleur e N utilisez pas les adaptateurs de deux fils pour le
25. pasar moment neamente a bater a para probar su carga Si la alarma suena o el Sistema UPS no respalda la carga total recomendada permita que el Sistema UPS cargue las bater as por 12 horas y repita la prueba Si la alarma suena nuevamente comun quese con Tripp Lite para recibir informaci n acerca del centro de servicio m s cercano a usted PRECAUCION No desenchufe el sistema UPS para probar sus bater as Esto eliminar la conexi n a tierra y puede introducir picos el ctricos perjudiciales a las conexiones de su red Luces Indicadoras Todas las descripciones de la Luces Indicadoras son efectivas mientras el Sistema UPS est conectado a una l nea viva de CA y haya sido encendido ON Esta luz verde se iluminar mientras el sistema UPS est conectado y V recibiendo energ a normal de CA Esta luz roja se iluminar mientras el sistema UPS est suministrando energ a de bater a a sus equipos Esta luz amarilla se iluminar cuando la bater a del sistema UPS no est Ea totalmente cargada Si esta luz permaneciera encendida continuamente comun quese con Tripp Lite para obtener informaci n acerca del centro de servicio m s cercano a usted 10 Cuando el no break est regulando autom ticamente el voltaje bajo o alto de entrada esta luz verde se iluminar y el no break emitir un leve sonido Cuanto m s irregular sea el voltaje de entrada m s se iluminar esta luz verde y m s sonidos emitir r el no br
26. r changera batterie pour tester sa charge Si l alarme de UPS retentit ou la charge convenablement tablie n est pas support e laissez votre UPS charger ses batteries pendant 12 heures et r p tez le test Si alarme sonore encore contactez Tripp Lite pour du service AVERTISSEMENT Ne d branchez pas le syst me d onduleur pour tester ses batteries Cela enlevera la terre l ctrique s re et peut introduire une surtension endommageante aux connexions de r seau Indicateurs Lumineux Toutes descriptions sur l indicateur lumineux s appliquent lorsque votre UPS est connect la prise murale et sur la position MARCHE Ce DEL vert s allumera quand votre syst me d onduleur est branch une ligne c a et re oit l alimentation c a normale Ce DEL rouge s allumera quand votre syst me d onduleur fournit votre quipement d alimentation par batterie 16 Ce DEL jaune s allumera quand la batterie du syst me d onduleur n a pas une pleine charge S il est allum constammant contactez Tripp Lite pour du service Quand votre systeme d onduleur correcte la tension haute ou basse VA cet indicateur vert s allume et le syst me d onduleur claquera doucement Plus l UPS doit corriger la tension plus l indicateur vert s allumera et plus le syst me d onduleur claquera Ces op rations sont normales et automatique et il ne faut rien faire exced e quand alimentant par batterie m me pendant un auto te
27. ribiendo los s ntomas del problema Si la unidad est dentro del periodo de garant a de 2 a os adjunte una copia de su factura original 12 Especificaciones T cnicas OmniSmart 300 OmniSmart 450 OmniSmart 675 Capacidad de Salida VA Watts 300 180 Tiempo de Respaldo Media Carga Plena Carga Minutos 17 5 Tiempo de Respaldo T pico Computadora y Monitor de 15 pulgadas Minutos 30 Tiempo de Recarga de la Bater a 2 4 hrs Certificaciones UL cUL Protecci n Para M dem Fax Comienza a 260V 1 l nea OmniSmart 850 450 300 17 5 30 2 4 hrs UL cUL 1 l nea OmniSmart 1050 675 425 17 5 45 2 4 hrs UL cUL 2 l neas OmniSmart 1400 Capacidad de Salida VA Watts 850 570 1050 705 1400 940 Tiempo de Respaldo Media Carga Plena Carga Minutos 26 9 23 7 24 8 Tiempo de Respaldo T pico Computadora y Monitor de 15 pulgadas Minutos 55 65 75 Tiempo de Recarga de la Bater a 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL cUL UL cUL UL cUL Protecci n Para M dem Fax Comienza a 260V OmniPro 280 OmniPro 450 OmniPro 675 Capacidad de Salida VA Watts 280 175 450 300 675 425 Tiempo de Respaldo Media Carga Plena Carga Minutos 17 5 17 5 17 5 Tiempo de Respaldo T pico Computadora y Monitor de 15 pulgadas Minutos 15 30 45 Tiempo de Recarga de la Bater a 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL cUL UL cUL UL cUL Protecci
28. riente de CA con conexi n a tierra de tres alambres No remueva o modifique la conexi n a tierra del enchufe del sistema UPS No conecte adaptadores de dos alambres al enchufe de este sistema UPS No conecte el enchufe del sistema UPS a sus propios recept culos esto da ar la unidad y anular su garant a Si usted desea conectar este sistema UPS a un generador del CA motorizado aseg rese que dicho generador proporcione energ a de salida limpia y filtrada Advertencias Sobre la Conexi n de Equipos No use sistemas UPS Tripp Lite en aplicaciones de soporte de la vida humana donde el una falla en la operaci n del sistema UPS Tripp Lite podr a causar fallas O alterar significativamente el funcionamiento de un dispositivo de soporte de la vida humana Advertencias Sobre la Bater a Este sistema UPS no requiere mantenimiento rutinario No abra el sistema UPS bajo ninguna circumstancia No hay partes que puedan ser reparadas por el usuario dentro de esta unidad El reemplazo de la bater a debe ser realizado por personal t cnico capacitado Deben obervarse todas las precauciones apropiadas ya que las bater as presentan riesgos de choques el ctricos y quemaduras por la alta corriente de cortocircuito Apague y desenchufe el sistema UPS antes de realizar el reemplazo de la bater a Use herramientas con asas aisladas y reemplace las bater as del sistema UPS con el mismo n mero y tipo de bater as nuevas Selladas de Plomo y Acido
29. rma es Tampa do Compartimento das Baterias LE Em condi es de funcionamento normal a bateria original do seu sistema UPS durar v rios anos A substituic o da bateria s deve ser feita por um t cnico habilitado Refira se as Advert ncias relativas a Bateria da secc o Seguranca situada na p gina 20 Armazenagem e Assist ncia Armazenagem Comece por desligar o interruptor do UPS e em seguida desligue a ficha da tomada de corrente Por fim desligue o equipamento de modo a evitar que a bateria se esgote Se Tenciona armazenar o seu sistema UPS durante um per odo longo recarregue completamente a bateria de tr s em tr s meses conetando o UPS a uma tomada de corrente activa ligando o interruptor e deixando carregar durante 4 a 6 horas Se deixar as baterias descarregadas durante muito tempo estas ser o definitivamente afetadas de perda de capacidade Assist ncia Se devolver o seu sistema UPS a Tripp Lite faca o favor de embalar ele cuidadosamente na EMBALAGEM ORIGINAL que vinha com a unidade Junte uma carta na qual descreve os sintomas do problema Se o sistema ainda est coberto pela garantia de 2 anos envie juntamente uma c pia da fatura ou do tal o de recibo do vendedor 23 Especifica es OmniSmart 300 OmniSmart 450 OmniSmart 675 Capacidade de Sa da VA Watt 300 180 450 300 675 425 Tempo de Execu o da Bateria Meia Carga Carga Total Min
30. s avec l unit Inclusez une lettre d crivant les symptomes du probl me Si le syst me d onduleur est re u dans le p riode de la garantie de 2 ans inclusez une copie de la facture de vente 18 Caract ristiques OmniSmart 300 OmniSmart 450 OmniSmart 675 Tension de Sortie VA Watts 300 180 Temps Secours par Batterie Pleine Charge Mi Charge Min 17 5 Temps Secours Type PC avec Moniteur de 15 po Min 30 Temps de Recharge de la Batterie 2 4 heures Homologations UL cUL Protection Modem Fax commence 260V 1 ligne OmniSmart 850 450 300 17 5 30 2 4 heures UL cUL 1 ligne OmniSmart 1050 675 425 17 5 45 2 4 heures UL cUL 2 lignes OmniSmart 1400 Tension de Sortie VA Watts 850 570 1050 705 1400 940 Temps Secours par Batterie Pleine Charge Mi Charge Min 26 9 23 7 24 8 Temps Secours Type PC avec Moniteur de 15 po Min 55 65 75 Temps de Recharge de la Batterie 2 4 heures 2 4 heures 2 4 heures Homologations UL cUL UL cUL UL cUL Protection Modem Fax commence a 260V OmniPro 280 OmniPro 450 OmniPro 675 Tension de Sortie VA Watts 280 175 450 300 675 425 Temps Secours par Batterie Pleine Charge Mi Charge Min 17 5 17 5 17 5 Temps Secours Type PC avec Moniteur de 15 po Min 15 30 45 Temps de Recharge de la Batterie 2 4 heures 2 4 heures 2 4 heures Homologations UL cUL UL cUL UL cU
31. st m me pendant une coupure de courant D branchez imm diatement l quipement surchargeant des prises avec secours par batterie Cet indicateur rouge s allumera quand la capacit de PUPS a t Disponible certains mod les Autres Caract ristiques du Syst me d Onduleur Prises C A Les prises fourniront votre quipement connect avec l alimentation c a pendant l op ration normale et elles fourniront l alimentation lil T par batterie pendant les coupures de courant et les baisses de tension Elles prot gera aussi votre quipement contre les surtensions et les parasites endommageantes Cependant certains mod les offrent des prises Surge Only Protection contre Surtensions Seulement identifi es l arri re de YUPS qui fournissent la protec tion contre les surtensions aux p riph riques sans commettant du pouvoir de batterie pour les supporter pendant les coupures de courant Plots T l phoniques RJ11 Disponibles certains mod les IT Ces plots t l phoniques prot gent votre quipement contre les surtensions sur la ligne t l phonique Branchant votre quipement ces plots est facutatif Votre syst me d onduleur fonnctionnera proprement sans cette connexion Port DB9 Disponibles a certains modeles y Le port DB9 permit la connexion de votre UPS n importe station de travail ou serveur Utilisez le avec le logiciel et le cablage Tripp Lite pour sauvegarder automatiquement l
32. utes 55 65 75 Battery Recharge Rate 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL UL cUL UL cUL Modem Fax Protection starts at 260V OmniPro 280 OmniPro 450 OmniPro 675 Output Capacity VA Watts 280 175 450 300 675 425 Battery Runtime Half Load Full Load Minutes 17 5 17 5 17 5 Typical Runtime Desktop PC 15 in monitor Minutes 15 30 45 Battery Recharge Rate 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL UL cUL UL cUL Modem Fax Protection starts at 260V 1 line 2 line ALL MODELS Input Voltage Frequency 120V 60 Hz On Line Input Voltage Range 87 145 volts Voltage Regulated Output Voltage Range 120V 6 12 On Battery Output Voltage Range 120V 5 Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A 8 B standards AC Noise Attenuation gt 40 dB AC Protection Modes H to N H to G N to G FCC Part 68 Notice U S only If your Fax Modem Protector causes harm to the telephone network the Telephone Company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it do

Download Pdf Manuals

image

Related Search

Related Contents

"取扱説明書"  owners guide and parts manual istruzioni per l`uso e lista delle parti  TE10A Notice HA175246FRA  Appendix J: SOP of Reporting and Calculation of Contaminant  Technicolor - Thomson 15LB020S4 User's Manual  SNF-Tー-324 取扱説明書 (保証書付き) ・CDY-。zー LP 。CDY  設 計 書  Chevrolet 2012 Automobile User Manual    Samsung S19C200BR  

Copyright © All rights reserved.
Failed to retrieve file