Tripp Lite OmniSmart Line Interactive UPS System

image

Contents

1. Use the MUTE TEST button to do two things Silence the UPS On Battery Alarm Press and hold this button to silence the UPS On Battery alarm a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery Note When the battery is nearly depleted the Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down connected equipment Run a Self Test Your UPS performs a self test whenever it is first plugged in To have it run a self test at another time leave your con nected equipment on With your UPS plugged in and in the UPS mode press and hold this button until you hear a beep about 2 seconds then release it Results of a Self Test All the LEDs will be lit and the UPS will emit several short beeps as it momentarily switches to battery to test its charge and load capacity The test will last at most 10 seconds If the inverter is overloaded the 2 LED on select models will stay lit and the UPS will continue to beep after the test if this happens remove some of the load and run the self test again If the batteries seem weak the 21 LED will stay lit and the UPS will continue to beep after the test if this happens let UPS charge its batteries for 12 hours and repeat the test If the condition persists contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe elec
2. ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Coverage also does not apply to connected medical and industrial equipment To receive service under this warranty you must be the original purchaser user of the product in question You must obtain a Returned Material Authorization RMA number from Tripp Lite Products must be returned to Tripp Lite with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase g Two symbols are used on the label V AC Voltage V TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 200311038 93 2206_EN
3. extension cords to connect the UPS to an AC outlet Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet f the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This may damage the UPS and will void the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object The UPS batteries are recyclable Refer to local codes for disposal requirements or in the USA only call 1 800 SAV
4. line tel DSL 1 line te DSL Ethemet None Model OMNISMART1000VS OMNISMART1050 OMNISMART1400 Series AGOM1000USBKSR6 AGOM1050PJR61 AGOM1400PSR61 Input Voltage Frequency 120V 60 Hz 120V 60 Hz 120V 60 Hz On Line Input Voltage Range 83 147 volts 75 147 volts 75 147 volts Output Capacity VA Watts 1000 500 1050 705 1400 940 Battery Runtime Half Load Full Load Minutes 17 5 23 7 24 8 Battery Recharge Time 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL NOM FCC B UL cUL NOM FCC B UL cUL NOM FCC B Tel Fax Data Protection 1 line tel DSL None None ALL UNITS Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB at 1MHz AC Protection Modes H to N H to G N to G FCC RADIO TV INTERFERENCE NOTICE Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or
5. unit Enclose a letter describing the symptoms of the problem If the UPS is within the warranty period enclose a copy of your sales receipt Specifications Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice SmartPro USB UPS Systems Model SMART500USB SMART550USB SMART700USB Series 163620U1 AGSMS500USBKJR6 AGOM1000USBKSR6 Input Voltage Frequency 120V 60 Hz 120V 60 Hz 120V 60 Hz On Line Input Voltage Range 83 147 volts 83 147 volts 83 147 volts Output Capacity VA Watts 500 300 550 300 700 450 Battery Runtime Half Load Full Load Minutes 17 5 17 5 20 6 Battery Recharge Time 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL NOM FCC B UL cUL NOM FCC B UL cUL NOM FCC B Tel Fax Data Protection 1 line tel DSL 1 line tel DSL 1 line tel DSL Ethernet OmniSmart UPS Systems Model OMNISMART300 OMNISMART500 OMNISMART700 OMNISMART850 Series 163550U AGSMS500USBKJR6 AGOM700USBKSR61 AGOM1050PJR61 Input Voltage Frequency 120V 60 Hz 120V 60 Hz 120V 60 Hz 120V 60 Hz On Line Input Voltage Range 83 147 volts 75 147 volts 75 147 volts 75 147 volts Output Capacity VA Watts 300 180 500 300 700 425 850 600 Battery Runtime Half Load Full Load Minutes 17 5 17 5 22 7 26 9 Battery Recharge Time 2 4 hrs 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL cUL NOM FCC B UL cUL NOM FCC B UL cUL NOM FCC B UL cUL NOM FCC B Tel Fax Data Protection 1 line tel DSL 1
6. LEAD or 1 800 8 BATTERY 1 800 8 228 8379 or visit www rbre com for recycling information Do not dispose of the batteries in a fire Do not attempt to add external batteries Quick Installation ii Connect your UPS to an electrical outlet Your UPS will run a self test after it is d plugged in See Basic Operation to understand the results of its self test o A Plug your computer monitor and other equipment into the UPS system Your UPS is designed to support only com puter equipment You will overload your UPS if you connect high power draw equipment such as household appliances or laser printers to outlets providing UPS battery backup Select models feature special outlets clearly labeled on the rear panel which provide surge only not battery backup protection designed for laser printers and other heavy draw devices El Select UPS Operating Mode Press the ON OFF button to toggle your UPS between the UPS LED lit and the CHARGE ONLY LED flashing modes Choose the operating mode based on your location USA Canada amp Western Europe Leave the UPS in the UPS mode at all times All other countries Put the UPS in the CHARGE ONLY mode when you are not using connected equipment WARNING When set to CHARGE ONLY the UPS will not provide battery backup during a blackout or brownout Put the UPS i
7. Owner s Manual OmniSmart amp SmartPro USB 120V Input Output Line Interactive UPS Systems Register on line today for a chance to win C US a FREE Tripp Lite product www tripplite com warranty UL1778 important safety Instructions KE C ee 7 er bud Espanol 9 Francais 17 4fiiilii a A TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2003 Tripp Lite All rights reserved OmniSmart is a trademark of Tripp Lite SmartPro is a registered trademark of Tripp Lite Important Safety Instructions VAN SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings Install your UPS indoors away from excess moisture or heat dust or direct sunlight For best performance keep the indoor temperature between between 32 F and 104 F 0 C and 40 C Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection Do not use
8. d operating primary protection device at the telephone service entrance such devices are normal ly added during telephone line installation All above warranties are null and void if the Tripp Lite product has been improperly installed tampered with or altered in any way or if the connected equipment was not used under normal operating conditions or in accordance with any labels or instructions All claims under this warranty must be submitted in writing to Tripp Lite within 30 days of the occurrence or the claim will not be considered This warranty does not include damage resulting from accident or misuse and applies to the domestic USA amp Canada use of these products only Tripp Lite reserves the right to determine whether the damage to the connected equipment is due to malfunction of the Tripp Lite product by requesting the equipment in question be sent to Tripp Lite for exam ination This policy is above and beyond only to the extent needed of that provided by any coverage of connected equipment provided by other sources including but not limited to any manufacturer s war ranty and or any extended warranties EXCEPT AS PROVIDED ABOVE TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to purchaser EXCEPT AS PROVIDED
9. e installation must comply with all applicable electrical and safety codes set forth by the National Electrical Code NEC Except as provided above this warranty does not cover any damage to properly connected electron ic equipment resulting from a cause other than an AC power transient If user meets all of the above requirements Tripp Lite will repair or replace at Tripp Lite s option equipment up to the specified value See Ultimate Lifetime Insurance Policy Limits No coverage is allowed for damage entering from telephone or data lines unless they are separately protected as described below Telephone and Data Line Transients Tripp Lite will repair or replace directly connected equipment that is damaged by transients on telephone and or data lines only when all such paths are protected by a Tripp Lite protection product s and the AC power utility line is simultaneously protected by a Tripp Lite power protection device UPS surge suppressor or line conditioner with Ultimate Lifetime Insurance cover age Additional telephone and or data line connected devices downstream must have their own telephone and or dataline protectors Reimbursement dollar limits will be equal to that of the Tripp Lite power protection protector Coverage is excluded where a suitable environment for the protection device is not provided including but not lim ited to lack of a proper safety ground Telephone service equipment must also include a properly installed an
10. equipment If they do you will be given advance notice so as to give you an opportunity to maintain uninterrupted service 4 If you experience trouble with this Fax Modem Protector please contact Tripp Lite Customer Support 1111 W 35th Street Chicago Illinois 60609 Phone 773 869 1234 for repair warranty information The tele phone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure that the equipment is not malfunctioning 5 This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation for information EQUIPMENT ATTACHMENT LIMITATIONS Models with the Industry Canada label in Canada only NOTICE The Industry Canada label identifies certified equipment This certification means that the equip ment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above co
11. g modes Choose your UPS s operating mode based on the regional guidelines in Step 3 of the Quick Installation section UPS Mode ENABLES battery backup UPS Conditions The UPS charges its battery and supplies power at its receptacles when it is receiving utility line power If utility power fails the UPS provides power from its batteries The V indicator light is lit Setting Advantages Provides battery backup during blackouts or brownouts Basic Operation continued CHARGE ONLY Mode DISABLES battery backup UPS Conditions The UPS charges its battery and supplies power at its receptacles when it is receiving utility line power The V indica tor light is flashing Setting Advantages Continues to charge the bat tery when power is present while turning OFF the inverter to prevent battery depletion during power outages when equipment is not in use Cold Start Your UPS You may cold start your UPS and use it as a stand alone power source when utility power is not present providing that the UPS battery is charged To cold start your UPS press and hold the ON OFF button until you hear a beep about 2 seconds then release it The E3 indicator light will illuminate and AC power inverted from stored battery power will be provided at its receptacles Shut Down Your UPS Press and hold the ON OFF button when AC line power is absent i e during a blackout or when the UPS is unplugged to deactivate your UPS
12. n the UPS mode when you are using connected equipment See Basic Operation section for a complete explanation of each mode Quick Installation optional These connections are optional Your UPS will function properly without these connections Kl Phone Line Network Line Surge Suppression Select models only Your UPS has either jacks which protect against surges over a phone or network dataline or jacks which protect against surges on a phone line only See Specifications to determine which jacks your model has Using telephone cords or network data cables as appropriate connect your wall jack to the UPS jack marked IN Connect your equipment to the UPS jack marked OUT Make sure the equipment you connect to the UPS s jacks is also protected against surges on the AC line E USB Communications Use any USB cable to connect the USB port of your computer to the USB port of your UPS Download the PowerAlert UPS monitoring software program appropriate for your operat ing system from www tripplite com and install it on your computer Basic Operation Buttons Use the ON OFF button to do three things Switch your UPS s Operating Mode While your UPS is plugged into a live AC outlet press the ON OFF button and hold it until you hear a beep about 2 seconds to toggle between the following operat in
13. nditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecom munications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Ultimate Lifetime Insurance Tripp Lite warrants for the lifetime of the product at Tripp Lite s option to repair or replace on a pro rata basis directly connected equipment that is damaged due to power transients while properly connect ed to Tripp Lite products offering the Ultimate Lifetime Insurance Policy Power transients include spikes and surges on the AC power data or telephone lines that the Tripp Lite products have been designed to protect against as recognized by industry standards AC Power Line Transients To claim damages the Tripp Lite product must be plugged into a properly wired and grounded outlet No extension cords or other electrical connections may be used Th
14. nt When experimenting with dif ferent settings for this dial operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations The experiment should last long enough to assure that all expected line con ditions are encountered Automatic Voltage Regulation During brownouts your UPS will auto matically correct low AC line voltage When automatic voltage regulation is operating your UPS may be heard to click gently This is a normal auto matic operation of your UPS and no action is required on your part Storage amp Service Storage All connected equipment should be turned off then disconnected from the UPS to avoid bat tery drain Unplug your UPS from its AC receptacle then press and hold its ON OFF button to deactivate it Your UPS is now ready for storage If you plan on storing your UPS for an extend ed period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS bat teries discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning your UPS for service contact your local Tripp Lite dealer or distributor They will refer you to a service center Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the
15. pp Lite Customer Support or con sult your power protection software manual for more information Battery Replacement Door Under normal conditions the original bat tery in your UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 Power Sensitivity Lowline Adjustment This dial is normally set fully counterclockwise which enables the UPS to protect against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to providing PWM sinewave power from its battery reserves for as long as the distortion is present In some areas with poor utility power or where the UPS s input power comes from a backup NORM DELAY generator frequent brownouts and or chronic waveform distortion could cause the UPS to switch to battery too often draining its battery reserves You may be able to reduce how often your UPS switches to battery due to waveform distortion or brownouts by experimenting with dif ferent settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC wave form and reduces the voltage point at which it switches to battery NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion and the lower the input voltage the UPS will allow to pass to connected equipme
16. television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party respon sible for compliance could void the user s authority to operate the equipment CONSUMER INFORMATION AND FCC REQUIREMENTS U S only 1 This equipment complies with Part 68 of the FCC rules On the top or bottom of this equipment is a label that contains among other information the FCC registration number for this equipment If requested provide this information to your telephone company 2 If your Fax Modem Protector causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC 3 Your telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of your
17. trical grounding and may introduce a damaging surge into your network connections Depending on the condition of the incoming voltage the VOLTAGE REGULATION LED may or may not be lit Basic Operation continued Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on LINE POWER This green light will turn ON whenever your UPS is receiving normal AC line power It will flash while the UPS is in CHARGE ONLY mode to indicate that the UPS will not provide battery backup during a black out or brownout BATTERY POWER This yellow light will turn ON when your UPS is pro viding your equipment with battery power BATTERY CHARGE This red light will turn ON continuously after the UPS runs a self test to indicate that the UPS s battery is weakly charged If it remains lit after you have allowed the UPS to charge for twelve hours and have run a second self test contact Tripp Lite for service OVERLOAD Select models only This red light will turn ON continuously when the UPS is providing power from battery or after the UPS runs a self test to indicate that the UPS s inverter is overloaded If it lights up immediately remove some of the equipment connected to the UPS and run a self test Large overloads may cause your UPS to shut down VOLTAGE REGULATION Select models only This light will turn ON when your UPS is automatically correcting high or low utility line
18. voltage The UPS will also click gently when this automatic voltage regu lation is operating These are both normal functions of your UPS and no action is required on your part Other UPS Features AC Receptacles UPS Surge receptacles are used to provide your con nected equipment with AC line power during normal operation and bat tery power during blackouts and brownouts They also protect your equip ment against damaging surges and line noise Surge only receptacles identified on the back of select UPS models are used to provide periph erals with surge protection without committing precious battery power to support them during blackouts Telephone Network Protection Jacks Select models only These jacks protect your equipment against surges over a telephone or data line Your UPS has either jacks which can be used with both phone and data lines or jacks which can be used with phone lines only See Specifications to deter mine what kind of jacks your UPS has Connecting your equipment to these jacks is optional Your UPS will work properly without this connection Basic Operation continued USB Port The USB port connects your UPS to any USB workstation or server Using this port your UPS can communicate line fail and low battery status to your computer Use with Tripp Lite software and any USB cable to automatically save open files and shut down equip ment during a blackout Contact Tri