Home

APC Rack PDU Extender, Basic, 2U, 30A, 200/208V

image

Contents

1. Arc www apc com Rack Power Distribution Unit Description AP7580 AP7581 AP7582 AP7583 and AP7584 are 24 A Rack Power Distribution Units PDUs that provide 120 or 208 volt power to rack mounted equipment AP7580 AP7581 28 foot NEMA L14 30 power cord Four 20 amp circuit breakers AP7580 Four NEMA L5 20 outlets AP7581 Four NEMA L6 20 outlets AP7582 28 foot NEMA L14 30 power cord Two 20 amp circuit breakers Twelve NEMA 5 20 outlets AP7583 AP7584 O 28 foot NEMA L14 30 power cord AP7583 Four NEMA L5 30 outlets AP7584 Four NEMA L6 30 outlets Rack Power Distribution Unit Safety and Grounding Read the following information before installing or operating your APC Power Distribution Unit PDU e e e e e e e e e e e The PDU is intended only for use with four wire grounded connections on APC Uninterruptible Power Supplies UPSs Do not plug the PDU into an electrical outlet or other device This PDU is intended for indoor use only Do not install this PDU where excessive moisture or heat is present Never install any wiring equipment or PDUs during a lightning storm Do not use extension cords or adapters with this PDU Do not work alone under hazardous conditions Check that the power cord plug and socket are in good condition Disconnect the PDU from the power outlet before you install or connect equipment to reduce the risk of e
2. A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment if applicable 5 Mark the RMA number clearly on the outside of the shipping carton 6 Ship by insured prepaid carrier to the address provided by the Customer Support technician Rack Power Distribution Unit Life Support Policy General policy Examples of life support devices American Power Conversion APC does not recommend the use of any of its products in the following situations In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term life support device
3. of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Except as provided herein APC makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction To obtain support for problems with your PDU 1 Note the serial number and date of purchase The serial number is located on the bottom of the PDU 2 Contact Customer Support at a phone number located on the back cover
4. the Power Cord Cut the cord 1 Cut the outer cord sleeve to the desired length Be careful not to cut through the four wire bundles The cord must remain at least 4 9 feet 58 8 inches long from unit to end Remove the cut sleeve from the wire bundles 2 Cut each wire bundle making sure each is approximately 1 5 inches from the end of the cord sleeve 3 Strip approximately 0 5 inches of insulation from each wire bundle Reassemble the plug 1 Twist together any loose wires 2 Fully insert each wire into its coordinating terminal on the plug face before you tighten the terminal screw Insert only the bare copper wires into the terminals Do not tin the wires that hold the strands together Note Wire color Terminal Red Terminal marked Y Black Terminal marked X Green Ground pin has a green screw White No markings has a silver prong 3 Tighten the terminal screws to a minimum torque of 18 inch pounds 4 Slide the plastic plug case back around the face of the plug Align the tab on the case with the corresponding opening on the plug face Secure the case by tightening two of the screws in the side of the case to a minimum torque of 10 inch pounds 5 Reattach the strain relief to the plug using the remaining two screws Tighten the screws to a torque of 16 to 20 inch pounds Verify that the plug is connected properly by performing the test procedures on page 6 for AP7580 or AP7583 page 7 for AP7581
5. ckets with the installed caged nuts Insert and tighten the screws 200 171170 Connect to an APC UPS 1 Route the power cord through one of the slots on the roof of the enclosure 2 If necessary route the PDU cord across a ladder connected to the enclosure to connect to an APC UPS 3 Plug the PDU into the L14 outlet on the rear of the UPS 10 Rack Power Distribution Unit Specifications Electrical Nominal input voltage 120 or 208 V Input frequency 50 or 60 Hz Input connectors NEMA L14 30 plug Output connectors AP7580 Four NEMA L5 20 outlets AP7581 Four NEMA L6 20 outlets AP7582 Twelve NEMA 5 20 outlets AP7583 Four NEMA L5 30 outlets AP7584 Four NEMA L6 30 outlets Maximum total current draw 24 A Physical Size H x W x D 3 50 x17 20x3 50 in 8 89 x 43 69 x 8 89 cm Weight 14 0 Ib 6 4 kg Shipping weight 16 0 Ib 7 3 kg Environmental Elevation above MSL Operating 0 10 000 ft 0 3000 m Storage 0 50 000 ft 0 15 000 m Temperature Operating 0 to 45 C 32 to 115 F Storage 25 to 65 C 13 to 149 F Humidity Operating 0 95 RH Non condensing Storage 0 95 RH Non condensing Compliance Safety verification UL cUL Rack Power Distribution Unit 11 Warranty and Service Limited warranty Warranty limitations Obtaining service APC warrants the PDU to be free from defects in materials and workmanship for a period
6. gional centers Direct InfraStruXure Customer Support 1 877 537 0607 toll free APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702055 Ireland Japan 0 35434 2021 Australia New Zealand South Pacific 61 2 9955 9366 Australia Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2003 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo InfraStruXure and NetShelter are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 1583A 10 2003 InfraStruXure APC
7. hieved with a measurement of less than or equal to 1 Ohm Use the probes of the multimeter to verify continuity between the following points on the plug prongs and the slots on the outlets X on the plug and X 6 on the outlet Y on the plug and Y on the outlet Ground on the plug and Ground on the outlet Verify that there is no continuity among any of the four prongs on the plug View of the plug face A mm x le CH ce NZ Ground terminal Y terminal Neutral terminal Silver X terminal View of the outlets Ground connection Y connection X connection Rack Power Distribution Unit 7 How to Shorten the Power Cord Test the plug for AP7582 N Verify that all circuit breakers are in the ON position Note Use a multimeter and the following graphics to verify continuity between the test points on the AP7582 Continuity is achieved with a measurement of less than or equal to 1 Ohm Use the probes of the multimeter to verify continuity between the following points on the plug prongs and the slots on the outlets Ground on the plug and Ground on the outlet e Neutral on the plug and Neutral on the outlet X on the plug and X on the outlet Y on the plug and Y on the outlet Verify that there is no continuity among any of the four prongs on the
8. includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Rack Power Distribution Unit 13 Arc www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to find answers to frequently asked questions FAQs to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support with FAQs knowledge base and e support e Contact an APC Customer Support center by telephone or e mail Re
9. lectric shock when you cannot verify grounding Reconnect the PDU to the power outlet only after you make all connections Install the PDU so that the power plug may be disconnected for service Install the PDU so that there is not an uneven mechanical load Follow the nameplate ratings when connecting equipment to the supply circuit Do not overload the circuits An overload condition could put your over current protection at risk or cause problems with your supply wiring Risk of electrical shock Use only the supplied hardware to attach the mounting brackets Caution N The Rack PDUs are to be used only with InfraStruXure Type A systems Note Rack Power Distribution Unit How to Shorten the Power Cord A Only certified electricians can perform the following procedure Warning Plug layout Cord sleeve Strain relief Plug case Plug face Remove the plug 1 Loosen but do not remove the four captive screws from the plug face until it is detatched from the plug 2 Loosen but do not remove the four screws from the sides of the plug until the cord easily slides in and out 3 Slide the plug case down the cord to your desired length N The cord must remain at least 4 9 feet 58 8 inches long Note 4 Loosen but do not remove all four terminal screws until you can remove all four wires from the plug Set the plug face aside for later use 4 Rack Power Distribution Unit How to Shorten
10. or AP7584 or page 8 for AP7582 Rack Power Distribution Unit 5 How to Shorten the Power Cord Test the plug for AP7580 or AP7583 For AP7580 verify that all circuit breakers are in the ON position o Note Use a multimeter and the following graphics to verify continuity between the test points on the AP7580 or AP7583 Continuity is achieved with a measurement of less than or equal to 1 Ohm Use the probes of the multimeter to verify continuity between the following points on the plug prongs and the slots on the outlets Ground on the plug and Ground on the outlet e Neutral on the plug and Neutral on the outlet X on the plug and X 69 on the outlet Y on the plug and Y on the outlet Verify that there is no continuity among any of the four prongs on the plug View of the plug face a mm m A x Y ET MZ Ground terminal Y terminal Neutral terminal Silver X terminal View of the outlets Ground connection Neutral connection X connection Y connection Rack Power Distribution Unit Test the plug for AP7581 or AP7584 How to Shorten the Power Cord For AP7581 verify that all circuit breakers are in the ON position o Note Use a multimeter and the following graphics to verify continuity between the test points on the AP7581 or AP7584 Continuity is ac
11. plug View of the plug face a mm m A GH W A A mi S Ground terminal Y terminal Neutral terminal Silver 066060 X terminal View of the outlets DD Ground connection Neutral connection X connection 08060 Y connection Rack Power Distribution Unit How to Install the PDU Mounting options Install the PDU in the bottom 2U of a NetShelter or any standard 19 inch EIA 310 D rack or enclosure using the mounting brackets provided The PDU can be installed in one of two ways with the outlets facing out of the rack or toward the roof of the rack Note The PDU is intended only for use with an APC UPS Do not plug it into an electrical outlet or another device Note Bracket mounting 1 Attach the mounting brackets to the PDU using four flat head screws per bracket provided To mount the PDU with the outlets facing out of the rack Rack Power Distribution Unit How to Install the PDU 2 Choose a location for the PDU The PDU occupies two U spaces The numbers on the enclosure s vertical rail denote the middle of a U space Note Tn a es te a Insert a caged nut provided with the enclosure above and below a notched hole on each vertical mounting rail in your chosen location b Align the mounting holes of the bra