Home
Billion BIPAC P104
Contents
1. e Reset button e Power AC Plug for BIPAC 2071 only e Power AC socket for BIPAC 2072 only e LED display 1 0 DET LED POWER LED PLC Powerline Link Act LED ETH Ethernet Link Act LED BiPAC 2071 112 35 X 77 70 X44 50 mm Pret mesa estat Power Saving Reduce power consumption by at least 60 during power saving mode Operating Temperature Operating temperature 0 40 C Humidity e Storage temperature 20 70 C e Humidity 5 95 non condensing Getting Started 7 fe Safety Warnings Do not use the adapter in high humidity or high temperature environment Do not open or repair the case yourself Avoid using this product and all its accesories outdoor Place the adapter on a stable surface Only HomePlug AV compliant Powerline Communication PLC adapter for remote access 1s necessary Features HomePlug AV 200 Ethernet Bridge l Ze Physical layer data rate up to 200Mbps over existing Powerline Uses powerline technology that takes advantage of the unused bandwidth of the electrical wiring in the home Ideal for Triple Play applications such as IPTV VoIP telephony and high speed Internet access Support 10 100 MDI MDIX Ethernet switching Compliant with the HomePlug Powerline Alliance Industry specification HomePlug AV Power supplier design inside Ideal for Residential Users Power Saving mode When PC or other Ethenet devices are completely power off Billion Ho
2. ETH Ethernet Link Act Lit when an Ethernet data signal is transmitted or LED received Sync Button Used to establish a LAN network with other Ethernet Reset Button Press this button to restore the device configuration to Ethernet Port Connect the HomePlug AV device with an Ethernet device eg PC or modem router with the Ethernet cable included Power Plug AC Power Plug into an electric socket to draw power and to form Cord a powerline network with other HomePlug AV devices Sync Button Function There are 3 types of Sync Button trigger states l Broadcast State A BiPAC 2071 2072 device can provide information for another BiPAC 2071 or 2072 device to join its powerline network group works even if it 1s currently the only device existing within the network group 2 Join State For an ungrouped BiPAC 2071 or 2072 device to join an existing powerline network group 3 Press the Sync Button on the first BIPAC 2071 2072 device to turn it to Broadcast State Then press the Sync Button of an ungrouped BiPAC 2071 2072 device to turn it to a Join State 4 Ungroup State Press the Sync Button for more than 10 seconds to separate the device from 1ts current attached network group HomePlug AV 200 Application Scenarios Scenario 1 A BiPAC 2071 2072 device A wants to form a network group with another BiPAC 2071 2072 device B Y ou can allocate whichever device A or B to be the Broadcast State and the Join St
3. check the AutoScan box to turn on the Auto Scan function or check off the box to turn off the Auto Scan function Troubleshooting Problem My Homeplug device is unable to detect my other HomePlug device Solution This may due to the accidental change of the device password Access the HomePlug AV Utility and select the Privacy Tab Enter the password HomePlugAV Case Sensitive in the blank provided Then press the Set to Local Device Only button Repeat the same procedure to the other HomePlug device
4. 960 0 KE Drops 0 Fails 0 Highest 0 00 Mbps Lowest 0 00 Mbps Remote Device History Log MAC Address Hale Mbps Metwork Last Seen test 00 11 22 33 44 69 ote HomePlug Jul 1811 27 Device 3 00 11 22 33 44 66 not entered HomePlug Julia 11 27 Device 4 00 11 22 33 44 65 not entered l HomePlug Julia 11 27 i Delete Email Report Save Report Print Report The Diagnostics Tab screen shows System information and a history of all remote devices seen over a period of time This screen is available for OEM ODM Customization The Upper panel shows technical data concerning software and hardware present on the host computer which were used for communication via HomePlug device on the Powerline network The data includes the following e Operating System Platform Version e Host Network Name e User Name e MAC Address of all NICs Network interface card connected to the host e Identify versions of all Driver DLLs and Libraries used NDIS and optionally e MAC Firmware Version e MAC addresses of all devices connected locally to the host e Version of the Configuration Utility e Vendor name e Microprocessor The Lower panel contains a history of all remote devices seen on the computer over a certain period of time All devices that were on the powerline network are listed here along with a few other parameters Devices that are active on the current logical network will show
5. BILLION BIPAC 2071 HomePlug AV 200 Ethernet Adapter BIPAC 2072 HomePlug AV 200 Ethernet Bridge with AC Pass Through User Manual Table of Contents POUM A Ea 3 Features amp Specifications ccoonccccnncccocnnccocnnnoncncnencnnnenannnnnnarenannrenannrenananenanens 3 Getting Starte nuria 5 Features HomePlug AV 200 Ethernet Bridge oooooooonnnnncncncnoconnnnnnnnnnnnnononananoos 5 EA A ahaa inna 6 Sync DUHOMEPUNCHOD mirana a A N 8 HomePlug AV 200 Application Scenarios ccccccccccnnnnnnnnnnnnanononcnnnnnnnnonnnnnnnnnnoss 8 APP Ica ton TOS TAO ies 10 BIPAC 2071 2072 Utility Installation Procedures cconcconccoconioncconanonas 11 Microsoft NET Framework 2 0 Installation ooooonnnnnnncccccnonnnnnnnonononnnnononnos 13 BiPAC 2071 2072 Utility Installation oocccnncnnnncnccncnnnoninoninononininininininininons 16 Starting BiPAC 2071 2072 Utility o oooncconcconncocococacconoconaccnnnconanonanenannns 19 Understanding BiPAC 2071 2072 Ulla 20 Maita ee 20 Password Setup Procedure aicea a a a NGE 22 Add New HomePlug Device to a Powerline Network 23 Pivac y A baa dual ad ina duh head 24 Diagnostics TaDerssnenee od 26 ADUE T diss e E oe 28 TrOUDIEeSNOO IM panic 29 Product Introduction BiPAC 2071 2072 1s a networking device that utilizes the existing wiring system as a path to transmit data signal through the inter conversion between digital and analo
6. a transfer rate in the Rate column devices on other networks or devices that may no longer exist are shown with a in the Rate column The following remote device information 1s available from the diagnostics screen e Device Alias Name e Device MAC Address e Device Password e Device Last known rate e Device Last Known Network name e Vendor name e Date device last seen on the network e MAC Firmware version e Number of dropped connections e Number of loss connection e The highest transmission rate recorded e The lowest transmission rate recorded e Total data sent The diagnostics information displayed may be saved to a text file for later use or can be printed for reference for a technical support call Devices which are not part of the network anymore can be deleted using the delete button A dialog window pops up with a confirmation message if we try to delete a device whose password has been entered About Tab PowerPacket Utility Main Privacy Diagnostics About BILLON PowerPacket Utility Version 45 0 Build 1 0 Copyright E 2004 2007 billion Corp All Rights Reserved tp aay Billion corn Preferences Released November 6 2007 W AutoScan The About screen shows the software version and provides the HTML link to the Billion official website Clicking on the web address field will open a web browser that link directly to the web site Under the Preferences panel user can
7. al network name HomePlugAv The Privacy tab screen allows user to change its default public network type to a private network by changing the network name network password of devices The user can always reset the network type to HomePlug network Public by entering HomePlugAv as the network name or by clicking on the Use Default button Note Changing the network name to anything other than HomePlugAv will show the network type on the main screen as Private Set Local Device Only button can be used to change the network name network password of the local device If a new network password is entered all associated devices seen on the Main Tab prior to this will be no longer present in the new network rendering the local device unable to communicate with other devices in 1ts previous network Set All Devices button is used to change the logical network of all devices that appear on the Main tab screen whose Device Password had been entered for the same logical network A dialog window will appear to report the success of this operation For devices whose device passwords were not entered this operation will fail and will report a failure message Diagnostics Tab PowerPacket Utility Main Privacy Diagnostics About System Information On MIC 1 MAC 00 E0 18 7D CC 94 HomePlug Device 1 MAC 00 11 66 13 F1 35 Network name HomePlug Vendor Billior Firmware HP 1 0 Reads 133520 1 KBJ Writes 40
8. ate Example 1 Hold down the Sync Button of device A for 1 3 seconds to turn it into Broadcast State 2 Hold down the Sync Button of device B for 1 3 seconds to turn it into Join State 3 Wait for the Sync LED of both devices to light up then you will now have both devices being in the same network group Note Once the device is plugged into the electric socket connect it with an Ethernet cable within 60 seconds to prevent the device from Auto Power Off Scenario 2 A BiPAC 2071 2072 device wants to join an existing network group BC Device A wants to join a network group BC currently consisting of device B and device C Any devices within the BC group can become the Broadcast State and device A will be the Join State Example 1 Hold down the Sync Button of device B or C of the BC network group for 1 3 seconds to turn 1t into Broadcast State 2 Hold down the Sync Button of device A for 1 3 seconds to turn it into Join State Wait for the Sync LED of both devices A and B or C to light up then you will now have device A join the BC network group Note Once the device is plugged into the electric socket connect it with an Ethernet cable within 60 seconds to prevent the device from Auto Power Off Scenario 3 A BiPAC 2071 2072 device A of network group AD wants to join an existing network group BC For a device which already belongs to a network group 1s to join with a different network group t
9. e device will be seen If there is more than one local device being connected eg USB Ethernet adapter user can select the local device by clicking on it and then click the Connect button to its right The status area above the button indicates that your PC is connected to that same device Once connected to the local device the utility will automatically scan the power line periodically for other newly connected HomePlug devices If no local HomePlug devices are discovered the status area above the connect button will indicate with a message NO HOMEPLUG ADAPTERS DETECTED The lower panel displays all the HomePlug remote devices detected on the current network The total number of remote devices connected on the same network can be found on top of the Remote device panel The Network type Public or Private is also displayed based on the network status of the local device The scan status option is displayed on the top right corner above the Remote devices panel showing whether the Autoscan function is turned ON or OFF The following information is displayed for all devices that appear in the lower panel Device Name Show the default device name User can change the name by either clicking on the rename button or by clicking on the name and editing in place An icon 1s usually shown with the device name Password required when creating a private network This column is left blank by default The password will be disp
10. esult in severe cil or criminal penalties and will be prosecuted to the masimum extent possible under the law Cancel You may define the location of the installation folder using the Browser or use the default location In addition you can also choose to install BiPAC 2071 2072 Utility only for yourself or for all the users who share your PC When all necessary items are properly selected press 7 BiPAC 2071 2072 Utility Select Installation Folder The installer will install BIPAC 2071 2072 Utility to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program Files bilionsBiPAC 2047 02 L tility Browse Disk Cost Install BIPAC 207 207 Utility for yourself or for anyone who uses this computer le Evenone C Just me Cancel Back 3 to confirm and start the installation 7 BiPAC 2071 2072 Utility Contirm Installation The installer is ready to install BIPAC 2077 2072 Utility on pour computer Click Next to start the installation Cancel Back 4 Wait until the installation process is complete then press complete the utility setup 7 BiPAC 2071 2072 Utility Installation Complete BIPSE 2071 2072 Utility has been successfully installed Click Close to exit Starting BiPAC 2071 2072 Utility Once the BiPAC 2071 2072 Utility Setup Wizard is instal
11. g signal With this functionality BIPAC 2071 2072 can be plugged into an electrical socket to draw power and at the same time establishing a network connection between two or more Ethernet devices The BIPAC 2071 2072 can be used to bridge any Ethernet device to your Powerline network in your home or office With this technology Ethernet devices in your home or office can equally share high speed data transmission rate without the need to spend excessive time and money installing expensive Ethernet cable It can be plugged into an Ethernet port on a router to equip a network with Powerline capabilities and take advantage of the router features The BiPAC 2071 2072 can also be plugged directly into a cable or DSL modem that allows instant internet access over home Powerlines to each computer equipped with a HomePlug AV certified Powerline network adapter BIPAC 2071 2072 makes high speed modem sharing as fast and simple as plugging the devices in the wall Features amp Specifications Standard Ethernet specification IEEE 802 3 IEEE 802 3x Modulation Supports OFDM 1155 carriers 1024 256 64 QAM QPSK BPSK and ROBO Frequency Band 2MHz 30MHz Security 128 bit AES encryption over household power supplier grid Operation System e Windows 98 SE Me 2000 XP 32 and 64 bit Power Supplier e Input 100 240V AC 50 60Hz Specification Physical Interface e Interface Ethernet 10 100M MDI MDIX switch e Sync button
12. h the installation process 3 Check the Agreement acceptance box then press Install to start the installation When the installation is complete click Finish to exit ie Microsoft NET Framework 2 0 Setup ja lx End User License Agreement End User License Agreement MICROSOFT SOFTWARE SUPPLEMENTAL LICENSE TERMS MICROSOFT MET FRAMEWORK 2 0 Microsoft Corporation or based on where vou live one of its affiliates licenses this supplement to you IF you are licensed to use Microsoft Windows operating system software the software vou may use this supplement You may not use it if you do not have a license For the software You may use a copy of this supplement with each validly licensed copy of the software a By clicking I accept the terms of the License Agreement and proceeding to use the product I indicate that I have read understood and agreed to the terms of the End User License Agreement I accept the terms of the License Agreement fr Microsoft NET Framework 2 0 Setup alla Setup Complete BIPAC 2071 2072 Utility Installation l 7 BiPAC 2071 2072 Utility Welcome to the BIPAC 2071 2072 Utility Setup Wizard The installer will guide you through the steps required to install BIPAC 2071 2042 Utility on your Computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distibution of this program or any portion of it may r
13. hat device has to be ungrouped from its current attached group first Example 1 Hold down the Sync Button of device A for more than 10 seconds to ungroup it from network group AD 2 Then hold down the Sync Button of device B or C of network group BC for 1 3 seconds to turn it to Broadcast State 3 Hold down the Sync Button of device A again for 1 3 seconds to turn it to Join State 4 Wait for the Sync LED of both devices A and B or C to light up Now you will have device A join the network group BC Note Once the device is plugged into the electric socket connect it with an Ethernet cable within 60 seconds to prevent the device from Auto Power Off Application Illustration Home Office Setting Services Internet A The connected home using the BiPAC 2071 2072 Ethernet Cable Power Cable BiPAC 2071 2072 Utility Installation Procedures l Place the BiPAC 2071 BiPAC 2072 auto installation CD into your CD ROM DVD ROM drive and click on Utility for Easy Installation x BiPAC 2071 BIPAC 2072 Homeplug AV 200 Ethernet Series Utility for Easy Installation Click to establish the home networking automatically Quick Start Guide b Click to view the GG PDF User Manual b Click to read the user manual POF Browse CD Contents Click to browse CD contents Visit Billion Global Website Click to viet Bilion global website www billion com J 4 a Powering communicat
14. ific powerline network as desired To add a new device to a network l Press the Add button 2 When a Add Device to Network dialog box pops up enter the name and the password of the device to be added to the network in the blank provided then press OK Add Device to Network Device Name Mame Password PASS WORD GOES HERE The Password typically appears as a number and letter code in groups of four separated by dashes le EE Y GH26 BATE L25 4 Ibis found on the device or packaging Cancel Privacy Tab PowerPacket Utility Main Privacy Diagnostics About Use this screen to create a Private Network that provides you with extra security Private Network Mame HomePlug OR Use Default Public Network Do not share the network name with others you do not want to be part of this network After setting the name above choose how it will be applied below Place On This Network Only the device attached to this computer the Local Device Sy Leck danas ta Isolates this computer from others ef Local Device Uniy OR ALL devices whose Password has been entered They communicate together but are isolated from devices with Cet All Devices a different network name Privacy Tab is to allow user the convenience to manage the security of the private powerline network and to enable the adding of new HomePlug device to the private network All HomePlug devices are shipped using a default logic
15. ions with Security 2 If you have not installed Microsoft NET Framework 2 0 click on Install Microsoft NET Framework 2 0 to install this program first before installing BiPAC 2071 2072 Utility 3 If you have already had Microsoft NET Framework 2 0 installed please click on Install the utility for Windows 32 bit 64 bit and proceed to the section on BiPAC 2071 2072 Installation 4 If you are using Windows Vista operating system do not have to install Microsoft NET Framework 2 0 Simply click on Install the utility for Windows 32 bit 64 bit and proceed to the section on BiPAC 2071 2072 Installation x BILLION BiPAC 2071 BiPAC 2072 Homeplug AV 200 Ethernet Series Utility for Easy Installation To get started with utility please follow the steps below Step 1 Install Microsoft NET Framework 2 0 VYindowe Vista user can skip this step Step 2 Install the utility for Windows 32 bit Utility for Windowse 95M E 2000 P 32 bit vista 32 bit Step 2 Install the utility for Windows 64 bit Utility for Windows xP 64 bit Vvista 64 bit re Back to main menu www billion com Li a a Powering communications with Security Microsoft NET Framework 2 0 Installation 1 After clicking on Install Microsoft NET Framework 2 0 the Net Framework iis Microsoft NET Framework 2 0 Setup Welcome to Microsoft NET Framework 2 0 Setup This wizard will guide you throug
16. layed only after it has been created For detail information on password setup please refer to section on Password Setup Procedure Rate Mbps Display the data transmission rate of each device MAC Address Show the Remote device MAC address Quality Display the overall quality of the data transmission rate When the transmission rate 1s good the number of line appear will increase Password Setup Procedure l To assign a password to a specific device select the device and click on the Enter Password button at the bottom of the lower panel to call up the Set Device Password dialog box PE Set Device Password Device Device 4 00 11 42 33 44 65 Password The Password typically appears as a number and letter code in groups of four separated by dashes le MR OY GH26 BA1K L25 4 Ibis found on the device or packaging Cancel 2 Then type in the password in the blank provided and press OK Note The Password field accepts the Device password in any case formats with or without dashed between them 3 If the password entered is not recognized or unacceptable an error message box will pop up prompting user to change the password Invalid Entry The Device Password Entered is Invalid Wie Please check it and try again Add New HomePlug Device to a Powerline Network Additionally when there is more than one powerline network present a new HomePlug device can be added to any spec
17. led a shortcut will appear on the desktop You can start the BiPAC 2071 2072 Utility by double clicking on the shortcut or go through start All Program BiPAC 2071 2072 Utility BiPAC 2071 2072 Utility Utility amp Internet Explorer wo MSN e Outlook Express Microsoft Office Weor eg Files and Settings Tr DD Wizard Fa Remote Assistance G windows Media Player All Programs 3 Windows Messenger ah Windows Movie Maker E Windows Live fe BIPAC 2071 2072 Utility S BIPAC 207 1 2072 Utility Understanding BiPAC 2071 2072 Utility Billion BiPAC 2071 2072 Utility consists of 4 screens accessed through 4 panel tabs The 4 panels are Main Privacy Diagnostics and About located on the top left corner of the program for configuration convenience Main Tab PowerPacket Utility Main Privacy Diagnostics About Local Device s on your computer Device Type MAC Address a Powerline device 00 11 66 13F1 35 Connected on Powerline device 0 Powerline Devices detected Network Type Private Scanning Rate Mbps MAC Address BILLION Rename Enter Password Add Soan The Main Tab Screen lists all the powerline devices connected to the host computer when the utility is running The top panel shows all local HomePlug devices connected to the computer s NIC Network Interface Card Normally only on
18. mePlug device will automatically enter power saving mode which will help to reduce power consumption by at least 60 Noise Filter only available in BIPAC 2072 Allow the filtering of noise which may be generated by some electrical appliances such as vacumn cleaner and hair dryer to prevent possible interference with HomePlug AV network Hardware Overview BiPAC 2071 BiPAC 2072 1 0 DET LEB AC Outlet AC Pass thru Power LED E only available in BOW PLC LED BiPAC 2072 model Pa nan Eon baton ES un il Ii M mm Power Plug The Description of each labeled part is described in the table below AC Outlet AC Pass thru Enable the plugging in of another Ethernet device for only available in BiPAC direct power supply 2072 model The AC Pass thru allows the filtering of noise to prevent HomePlug AV Network interference Note The AC Outlet only support devices that use 6A maximum electric current 1 0 DET LED Blink when detect the presence of other HomePlug 1 0 devices that have the transmission rate of 14 or 85 Mbps Note Due to the incompatibility of HomePlug AV 200 with HomePlug 1 0 devices the presence of the HomePlug 1 0 devices within the powerline network will thus reduce the performance of your powerline network Power LED Lit when the device is power on PLC Powerline Link Act Lit when a network has been established Blink when powerline data is transmitted or received